Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANNUAL MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Photovoltaic (PV) Module Technologies: 2020 Benchmark Costs and Technology Evolution Framework Results

This report benchmarks 2020 PV module minimum sustainable price (MSP) via bottom-up manufacturing cost analysis, for established PV technologies in mass production, including crystalline silicon, cadmium telluride (CdTe), and copper indium gallium (di)selenide. We provide technology roadmaps to additional MSP reductions for these PV technologies. Separately, we consider III-V and perovskite PV technologies which are currently in small-scale or pilot production. Finally, this report uses a technology evolution framework (TEF) to analyze drivers of levelized cost of energy reductions, including installed system cost - which is heavily influenced by module price - as well as service life and annual energy yield.

14 SOLAR ENERGY↗

Long-Term Degradation of Passivated Emitter and Rear Contact Silicon Solar Cell under Light and Heat

Advanced designs enable high-efficiency solar cells; however, more complex structures create new long-term stability concerns. Herein, the long-term degradation processes affecting advanced silicon solar cells using laboratory-based illumination and heating over hundreds of hours are investigated. The activation energy for the degradation of voltage is estimated and the degradation rates to normal solar cell operating temperature ranges are extrapolated. The cell degradation observed at high temperatures in the lab is kinetically similar to the process affecting field-deployed modules contributing to 0.37% year-1 of annualized degradation. Electroluminescence and photoluminescence mapping show that the degradation is dominated by minority carrier lifetime reduction. Suns-open-circuit voltage and light beam-induced current results indicate that the degradation could result from passivation degradation at the surface or defect formation in the near-subsurface region, leading to increased minority carrier recombination. This work highlights a long-term degradation process under elevated temperature and illumination that may continue to affect cells in an irreversible manner that is separate from recoverable light-induced degradation and light- and elevated temperature-induced degradation.

14 SOLAR ENERGY↗

Heterogeneity in Permeability and Particulate Organic Carbon Content Controls the Redox Condition of Riverbed Sediments at Different Timescales

Abstract The hydrological and biogeochemical properties of the hyporheic zone in stream and riverine ecosystems have been extensively studied over the past two decades. Although it is widely acknowledged that sediment heterogeneity can influence biogeochemical reactions, little effort has been made to understand the role of heterogeneity on the spatiotemporal variability of riverbed redox conditions under changing flow dynamics at different timescales. Here we integrate a mechanistic model and field data to demonstrate that heterogeneity in permeability plays a vital role in modulating sediment redox conditions at both seasonal (annual) and event (daily‐to‐weekly) timescales, whereas heterogeneity in particulate organic carbon (POC) content only has a comparable influence on redox conditions at the seasonal timescale. These findings underscore the importance of accurately characterizing sediment heterogeneity, in terms of permeability and POC content, in quantifying biogeochemical dynamics in the riverbed and hyporheic zones of riverine ecosystems.

Geology↗

Photovoltaic Shading Testbed for Module-Level Power Electronics: 2016 Performance Data Update

The 2012 NREL report 'Photovoltaic Shading Testbed for Module-Level Power Electronics' provides a standard methodology for estimating the performance benefit of distributed power electronics under partial shading conditions. Since the release of the report, experiments have been conducted for a number of products and for different system configurations. Drawing from these experiences, updates to the test and analysis methods are recommended. Proposed changes in data processing have the benefit of reducing the sensitivity to measurement errors and weather variability, as well as bringing the updated performance score in line with measured and simulated values of the shade recovery benefit of distributed PV power electronics. Also, due to the emergence of new technologies including sub-module embedded power electronics, the shading method has been extended to include power electronics that operate at a finer granularity than the module level. An update to the method is proposed to account for these emerging technologies that respond to shading differently than module-level devices. The partial shading test remains a repeatable test procedure that attempts to simulate shading situations as would be experienced by typical residential or commercial rooftop photovoltaic (PV) systems. Performance data for multiple products tested using this method are discussed, based on equipment from Enphase, Solar Edge, Maxim Integrated and SMA. In general, the annual recovery of shading losses from the module-level electronics evaluated is 25-35%, with the major difference between different trials being related to the number of parallel strings in the test installation rather than differences between the equipment tested. Appendix D data has been added in this update.

14 SOLAR ENERGY↗

Albedo Data for Bifacial PV Systems

At the September 2018 Bifacial PV Workshop in Lakewood, CO, a better understanding of albedo values and characteristics was identified as a key need by both the PV and financial communities to better estimate performance and to reduce risk of bifacial PV systems. To meet this need, the U.S. Department of Energy (DOE) has initiated work with the National Renewable Energy Laboratory (NREL) to provide the following: A multi-year database of measured and quality assessed albedo values with temporal resolution of one hour or less for numerous locations and types of ground surfaces. Site metadata for each location (Pictures, instruments and calibration history, soil and vegetation types, etc.) Site albedo statistics for each location (diurnal profiles, monthly and annual means, interannual variability) Analysis of the spectral mismatch for bifacial PV modules of the ground-reflected radiation for anticipated deployment surfaces (using both measured and modeled spectral albedo data). Comparisons of the measured albedos with available satellite-derived MODIS albedo products to validate the MODIS albedo products for estimating bifacial PV system performance.

14 SOLAR ENERGY↗

Validating Irradiance Models for High-Latitude Vertical Bifacial Photovoltaic Systems

Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.

bifacial↗

FY 2019 DuraMAT Annual Report

This report summarizes the progress and successes of the Durable Module Materials Consortium in FY 2019.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Spatially varying seasonal modulation to tidal stream energy potential due to mixed tidal regimes in the Aleutian Islands, AK

We provide an assessment of the tidal stream energy resource of the Aleutian Islands, Alaska via a validated barotropic tidal numerical model of the region. Eight island passes are identified as energy “hotspots”. The annual mean kinetic energy fluxes, KEF , calculated at each pass vary from 1000 to 11,000 MW, while the annual available energy, AAE , varies from 5 to 42 MWh m −2 . Notable seasonal modulation to monthly power density averages and ranges are noted at some passes and not others. Seasonal adjustment is linked to the semi-annual solar declination cycle which enhances (dampens) diurnal (D 1 ) tidal amplitudes in summer/winter (spring/fall) as well as the time-varying phase lag between D 1 and semidiurnal (D 2 ) fortnightly tidal cycles. Annual variability in monthly mean power density scales with the tidal current form factor, F u , with the largest seasonal change occurring for F u > 1 (D 1 dominated tide). The spread in power density over a month is on average smaller for passes with mixed tides (F u = 1 ) than those with D 1 or D 2 dominance, as changes to fortnightly phase lag become influential to net power density ranges when tides are mixed. This study outlines overlooked, but relevant, long-term modulation to tidal streams in regions with mixed tides.

16 TIDAL AND WAVE POWER↗

SFRC Measurement Control Summary - FY23 Q3/Q4

Measurements with the Spent Fuel Rod Counter (SFRC) to be performed bi annually include 3 He detector efficiency checks (in both modules) and ion chamber channel tests with a pocket pulser. These measurements will all be performed at TA-35, building 27 where the SFRC is stored. Refer to LA-UR-22-31737 and LA-CP-22-20079 SFRC measurement control documents for a description of additional tests. Note that during this measurement period, counts could not be confirmed for the Si detectors, as an analog pulse to TTL box necessary for the DAQs to communicate with the detectors was still under construction. For this reason, typical measurements at the Calibrated Dose Facility were not performed for the second half of FY23. When these components are finished by the NEN electrical shop, the Si detectors will be implemented into these measurement control checks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stochastic PV performance/reliability model : preview of alpha version.

Problem Statement: (1) Uncertainties in PV system performance and reliability impact business decisions - Project cost and financing estimates, Pricing service contracts and guarantees, Developing deployment and O&M strategies; (2) Understanding and reducing these uncertainties will help make the PV industry more competitive (3) Performance has typically been estimated without much attention to reliability of components; and (4) Tools are needed to assess all inputs to the value proposition (e.g., LCOE, cash flow, reputation, etc.). Goals and objectives are: (1) Develop a stochastic simulation model (in GoldSim) that can represent PV system performance as a function of system design, weather, reliability, and O&M policies; (2) Evaluate performance for an example system to quantify sources of uncertainty and identify dominant parameters via a sensitivity study; and (3) Example System - 1 inverter, 225 kW DC Array latitude tilt (90 strings of 12 modules {l_brace}1080 modules{r_brace}), Weather from Tucumcari, NM (TMY2 with annual uncertainty).

14 SOLAR ENERGY↗

Cosmesis and Breast-Related Quality of Life Outcomes After Intraoperative Radiation Therapy for Early Breast Cancer: A Substudy of the TARGIT-A Trial

Purpose: To report the first comprehensive investigation of patient-reported cosmesis and breast-related quality of life (QOL) outcomes comparing patients randomized to risk-adapted single-dose intraoperative radiation therapy (TARGIT-IORT) versus external beam radiation therapy (EBRT) on the TARGIT-A trial. Methods and Materials: Longitudinal cosmesis and QOL data were collected from a subset of TARGIT-A participants who received TARGIT-IORT as a separate procedure (postpathology). Patients completed a cosmetic assessment before radiation therapy and annually thereafter for at least 5 years. Patients also completed the combined European Organization for Research and Treatment of Cancer (EORTC) core questionnaire and Breast-Specific Module in addition to the Body Image after Breast Cancer Questionnaire at baseline and annually thereafter. The combined EORTC questionnaires were also collected 3, 6, and 9 months after wide local excision. Results: An Excellent–Good cosmetic result was scored more often than a Fair–Poor result for both treatment groups across all time points. The TARGIT-IORT patients reported better breast-related QOL than EBRT patients. Statistically and clinically significant differences were seen at month 6 and year 1, with EBRT patients having moderately worse breast symptoms (a statistically significant difference of more than 10 in a 100-point scale) than TARGIT-IORT patients at these time points. Conclusion: Patients treated with TARGIT-IORT on the TARGIT-A trial have similar self-reported cosmetic outcome but better breast-related QOL outcomes than patients treated with EBRT. This important evidence can facilitate the treatment decision-making process for patients who have early breast cancer suitable for breast-conserving surgery and inform their clinicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Power Electronics and Electric Motors Annual Report -- 2013

This report describes the research into advanced liquid cooling, integrated power module cooling, high temperature air cooled power electronics, two-phase cooling for power electronics, and electric motor thermal management by NREL's Power Electronics group in FY13.

30 DIRECT ENERGY CONVERSION↗

The joint influence of albedo and insulation on roof performance: An observational study

We focus on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. This analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10 °C and 45 °C during summer months compared to black membranes that ranged between 10 °C and 80 °C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. Furthermore, this has important implications for determining the peak heating and cooling times.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revisiting ENSO/Indian Ocean Dipole phase relationships

Here in this paper we show that the characteristics of the Indian Ocean Dipole (IOD), such as its power spectrum and phase relationship with the El Niño–Southern Oscillation (ENSO), can be succinctly explained by ENSO combination mode (C-mode) wind and heat flux forcing together with a seasonal modulation of the air/sea coupled Indian Ocean (IO) Bjerknes feedback. This model explains the observed high-frequency near-annual IOD variability in terms of deterministic ENSO/annual cycle interactions. ENSO-independent IOD events can be understood as a seasonally modulated ocean response to white noise atmospheric forcing. Under this new physical null hypothesis framework, IOD predictability is determined by both ENSO predictability and the ENSO signal-to-noise ratio. We further emphasize that lead/lag correlations between different climate variables are easily misinterpreted when not accounting properly for the seasonal modulation of the underlying climate phenomena.

54 ENVIRONMENTAL SCIENCES↗

Reducing Operating Temperature in Photovoltaic Modules

Reducing the operating temperature of photovoltaic modules increases their efficiency and lifetime. This can be achieved by reducing the production of waste heat or by improving the rejection of waste heat. We tested, using a combination of simulation and experiment, several thermal modifications in each category. To predict operating temperature and energy yield changes in response to changes to the module, we implemented a physics-based transient simulation framework based almost entirely on measured properties. The most effective thermal modifications reduced the production of waste heat by reflecting unusable light from the cell or the module. Consistent with previous results and verified in this work through year-long simulations, the ideal reflector resulted in an annual irradiance-weighted temperature reduction of 3.8 K for crystalline silicon (c-Si). Our results illustrate that more realistic reflector concepts must balance detrimental optical effects with the intended thermal effects to realize the optimal energy production advantage. Methods improving thermal conductivity or back-side emissivity showed only modest improvements of less than 1 K. We also studied a GaAs module, which uses high-efficiency and high-subbandgap reflectivity to operate at an annual irradiance-weighted temperature 12 K cooler than that of a c-Si module under the same conditions.

14 SOLAR ENERGY↗

FY2018 PV Lifetime Annual Report (Final Project Report)

Started in 2016, the PV Lifetime Project is measuring PV module and system degradation profiles over time with the aim of distinguishing different module types and technology. Outdoor energy monitoring in different climates is supplemented with regular testing under repeatable test conditions indoors. The focus is on the PV module, as well as other hardware components (junction boxes, bypass diodes, and module-level electronics) attached to it. Hardware is installed at Sandia National Laboratories in New Mexico, at the National Renewable Energy Laboratory in Colorado, and at the University of Central Florida. The systems are continuously monitored for DC current and voltage, as well as periodic I-V curves at the string level. In the future, once degradation trends have been identified with more certainty, results will be made available to the public online. This data is expected to enable an increase in the accuracy and precision of degradation profiles used in yield assessments that support investments made in new PV plants. Current practice is to assume that degradation is constant over the life of the system. Forthcoming results in the next few years will help to determine whether this assumption is still appropriate.

14 SOLAR ENERGY↗