Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Two-screen single-shot electron spectrometer for laser wakefield accelerated electron beams

The laser wakefield acceleration electron beams can essentially deviate from the axis of the system, which distinguishes them greatly from beams of conventional accelerators. In case of energy measurements by means of a permanent-magnet electron spectrometer, the deviation angle can affect accuracy, especially for high energies. A two-screen single-shot electron spectrometer that correctly allows for variations of the angle of entry is considered. The spectrometer design enables enhancing accuracy of measuring narrow electron beams significantly as compared to a one-screen spectrometer with analogous magnetic field, size, and angular acceptance.

43 PARTICLE ACCELERATORS↗

Superconducting accelerating structures for very low velocity ion beams.

This paper presents designs for four types of very-low-velocity superconducting (SC) accelerating cavity capable of providing several MV of accelerating potential per cavity, and suitable for particle velocities in the range 0.006<v/c<0.06. Superconducting TEM-class cavities have been widely applied to cw acceleration of ion beams. SC linacs can be formed as an array of independently phased cavities, enabling a variable velocity profile to maximize the output energy for each of a number of different ion species. Several laboratories in the U.S. and Europe are planning exotic beam facilities based on SC linacs. The cavity designs presented here are intended for the front end of such linacs, particularly for the postacceleration of rare isotopes of low charge state. Several types of SC cavities have been developed recently to cover particle velocities above 0.06c. Superconducting four-gap quarter-wave resonators for velocities 0.008<{beta}=v/c<0.05 were developed about two decades ago and have been successfully operated at the ATLAS SC linac at Argonne National Laboratory. Since that time, progress in simulation tools, cavity fabrication, and processing have increased SC cavity gradients by a factor of 3-4. This paper applies these tools to optimize the design of a four-gap quarter-wave resonator for exotic beam facilities and other low-velocity applications.

43 PARTICLE ACCELERATORS↗

Longitudinal Beam-Shaping Simulation for Enhanced Transformer Ratio in Beam-Driven Accelerators

A beam-driven structure wakefield accelerator (SWFA) is currently under consideration for future multi-user Xray free-electron-laser (FEL) light sources. One of the challenges associated with SWFA is the efficient energy transfer from the drive to the main bunch that can be enhanced via a precise control over the drive-bunch current profile. This paper discusses the development and initial beam-dynamics simulation of the drivebunch longitudinal dynamics using the fast-tracking program TWICE. This code, written in PYTHON, allows for rapid prototyping of the beam shaping process while taking into account the collective effects using simplified models. This paper describes the algorithm implementation and its capabilities of including collective effects into both forward and backward tracking. Initial results of optimizing beam shape with a conventional linac to produce a drive beam with a shape optimized for SFWA are presented.

43 PARTICLE ACCELERATORS↗

High Gradient Two-Beam Electron Accelerator

A high-gradient two-beam electron accelerator structure using detuned cavities is described. A self-consistent theory based on a circuit model is presented to calculate idealized acceleration gradient, transformer ratio, and efficiency for energy transfer from the drive beam to the accelerated beam. Experimental efforts are being carried out to demonstrate this acceleration concept.

43 PARTICLE ACCELERATORS↗

High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-gradient two-beam electron accelerator

The main goal for this project was to design, build, and evaluate a detuned-cavity, collinear, two-beam accelerator structure. Testing was to be at the Yale University Beam Physics Laboratory, under terms of a sub-grant from Omega-P to Yale. Facilities available at Yale for this project include a 6-MeV S-band RF gun and associated beam line for forming and transporting a ~1 A drive beam , a 300 kV beam source for use as a test beam, and a full panoply of laboratory infrastructure and test equipment. During the first year of this project, availability and functionality of the 6-MeV drive beam and 300 kV test beam were confirmed, and the beam line was restored to a layout to be used with the two-beam accelerator project. Major efforts during the first year were also focused on computational design and simulation of the accelerator structure itself, on beam dynamics, and on beam transport. Effort during the second year was focussed on building and preparing to test the structure, including extensive cold testing. Detailed results from work under this project have been published in twelve archival journal articles, listed in Section IV of the technical report.

43 PARTICLE ACCELERATORS↗

Summary Report of Working Group 5: Electron Beam Driven Plasma Accelerators

Electron beam driven plasma accelerators have seen rapid progress over the last decade. Recent efforts have built on this success by constructing a concept for a plasma wakefield accelerator based linear collider. The needs for any future collider to deliver both energy and luminosity have substantial implications for interpreting current experiments and setting priorities for the future. This working group reviewed current experiments and ideas in the context of the demands of a future collider. The many discussions and presentations are summarized here.

43 PARTICLE ACCELERATORS↗

Physical conditions for conducting radiobiological experiments in beams of accelerated particles with high linear energy transfer

The design and construction of an accelerator to conduct radiobiological experiments is reported that uses aluminum filters to control the accelerated ion beam while preserving its stability, and a vacuum chamber to conduct the ion beam with the help of a collector through a lavsan exit port to the target. Depth distribution of the absorbed dose from a monodirectional ion beam is practically completely represented by the change in the energy spectrum of the biological object.

Kudryashov, Y. I.↗

Long-range persistence of femtosecond modulations on laser-plasma-accelerated electron beams

Laser plasma accelerators have produced femtosecond electron bunches with a relative energy spread ranging from 100% to a few percent. Simulations indicate that the measured energy spread can be dominated by a correlated spread, with the slice spread significantly lower. Measurements of coherent optical transition radiation are presented for broad-energy-spread beams with laser-induced density and momentum modulations. The long-range (meter-scale) observation of coherent optical transition radiation indicates that the slice energy spread is below the percent level to preserve the modulations.

43 PARTICLE ACCELERATORS↗

Application of International Linear Collider superconducting cavities for acceleration of protons.

Beam acceleration in the International Linear Collider (ILC) will be provided by 9-cell 1300 MHz superconducting (SC) cavities. The cavities are designed for effective acceleration of charged particles moving with the speed of light and are operated on p-mode to provide a maximum accelerating gradient. A significant research and development effort has been devoted to develop ILC SC technology and its rf system which resulted in excellent performance of ILC cavities. Therefore, the proposed 8-GeV proton driver in Fermilab is based on ILC cavities above {approx}1.2 GeV. The efficiency of proton beam acceleration by ILC cavities drops fast for lower velocities and it was proposed to develop squeezed ILC-type (S-ILC) cavities operating at 1300 MHz and designed for {beta}G=0.81, geometrical beta, to accelerate protons or H{sup -} from {approx}420MeV to 1.2 GeV. This paper discusses the possibility of avoiding the development of new {beta}G=0.81 cavities by operating ILC cavities on 8 / 9{pi}-mode of standing wave oscillations.

43 PARTICLE ACCELERATORS↗

Effects of the laser pulse irradiation point on a double layer target on the accelerated ion beam parameters

In proton acceleration by a laser pulse obliquely incident on a double layer target, it is shown by PIC simulations that the energy spread of the generated protons can be reduced by irradiating the laser pulse on to the off-center position of the target. This provides a way to control the proton energy spectrum. High energy protons are found to come from an area shifted from the initial target center towards the propagation direction of the laser pulse. We show that high energy protons with much smaller energy spread can be obtained by appropriately adjusting the size and position of the second proton layer.

43 PARTICLE ACCELERATORS↗

Accelerator and Beam Physics: Grand Challenges and Research Opportunities

Accelerator and beam physics (ABP) is the science of the motion, generation, acceleration, manipulation, prediction, observation and use of charged particle beams. It focuses on fundamental long-term accelerator and beam physics research and development. Accelerator and beam physics research has resulted in important advances in accelerator science, yet support for this research is declining. NSF has terminated its program in accelerator Science and funding by DOE through GARD and Accelerator Stewardship has been steady or declining. The declining support for accelerator research will slow advances and threaten student training and work-force development in accelerator science. We propose a robust and scientifically challenging program in accelerator and beam physics, which will position the field of US High Energy Physics to be productive and competitive for decades to come.

43 PARTICLE ACCELERATORS↗

Long pulse acceleration of MeV class high power density negative H{sup −} ion beam for ITER

R and D of high power density negative ion beam acceleration has been carried out at MeV test facility in JAEA to realize ITER neutral beam accelerator. The main target is H{sup −} ion beam acceleration up to 1 MeV with 200 A/m{sup 2} for 60 s whose pulse length is the present facility limit. For long pulse acceleration at high power density, new extraction grid (EXG) has been developed with high cooling capability, which electron suppression magnet is placed under cooling channel similar to ITER. In addition, aperture size of electron suppression grid (ESG) is enlarged from 14 mm to 16 mm to reduce direct interception on the ESG and emission of secondary electron which leads to high heat load on the upstream acceleration grid. By enlarging ESG aperture, beam current increased 10 % at high current beam and total acceleration grid heat load reduced from 13 % to 10 % of input power at long pulse beam. In addition, heat load by back stream positive ion into the EXG is measured for the first time and is estimated as 0.3 % of beam power, while heat load by back stream ion into the source chamber is estimated as 3.5 ~ 4.0 % of beam power. Beam acceleration up to 60 s which is the facility limit, has achieved at 683 keV, 100 A/m{sup 2} of negative ion beam, whose energy density increases two orders of magnitude since 2011.

43 PARTICLE ACCELERATORS↗

New Method for the Generation of Secondary Particle Beams at Accelerators

The generation of beams of secondary particles (π and K mesons) at proton accelerators is a difficult scientific and engineering problem. To obtain narrow directional particle beams for experiments, intense extracted proton beams are used, secondary particles (π and K mesons) are generated at an external target, and they are focused and transferred through long magneto-optical channels. In this work, a surprisingly simple method based on a crystal focusing device has been proposed to obtain secondary beams. An experiment on the production of a secondary beam using a crystal has been performed at the U-70 accelerator. Schemes for the formation of beams with energies E ~ 1 TeV have been proposed for large colliders such as the Large Hadron Collider.