Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cause and Cure - Deterioration in Accuracy of CFD Simulations With Use of High-Aspect-Ratio Triangular Tetrahedral Grids

Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD re-searchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions and also cause numerical instability. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where triangular/tetrahedral elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identities the reason behind the difficulties in use of such high-aspect ratio triangular/tetrahedral elements is presented here. As will be shown, it turns out that the degree of accuracy deterioration of gradient computation involving a triangular element is hinged on the value of its shape factor Gamma def = sq sin Alpha1 + sq sin Alpha2 + sq sin Alpha3, where Alpha1; Alpha2 and Alpha3 are the internal angles of the element. In fact, it is shown that the degree of accuracy deterioration increases monotonically as the value of Gamma decreases monotonically from its maximal value 9/4 (attained by an equilateral triangle only) to a value much less than 1 (associated with a highly obtuse triangle). By taking advantage of the fact that a high-aspect ratio triangle is not necessarily highly obtuse, and in fact it can have a shape factor whose value is close to the maximal value 9/4, a potential solution to avoid accuracy deterioration of gradient computation associated with a high-aspect ratio triangular grid is given. Also a brief discussion on the extension of the current mathematical framework to the tetrahedral-grid case along with some of the practical results of this extension is also provided. Furthermore, through the use of numerical simulations of practical viscous problems involving high-Reynolds number flows, the effectiveness of the gradient evaluation procedures within the CESE framework (that have their basis on the analysis presented here) to produce accurate and stable results on such high-aspect ratio meshes is also showcased.

CESE Method↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

Comparative Accuracies of Models for Drag Prediction During Geomagnetically Disturbed Periods: A First Principles Model Versus Empirical Models

We examine the accuracy of density prediction by the first principles model Thermosphere Ionosphere Electrodynamics General Circulation Model (TIEGCM) developed by the National Center for Atmospheric Research and compare it to the accuracy of three empirical models: Jacchia 71, the Naval Research Laboratory Mass Spectrometer Incoherent Scatter Extended 2000 (NRLMSIS), Jacchia 1971, and Jacchia-Bowman 2008. Comparisons are made for three large storms: the October 2003 storm, the March 2013 storm, and the March 2015 storm. To evaluate the accuracy of these models we use tracking data for nine space objects in low Earth orbit. Additionally, we evaluate the accuracy of the TIEGCM and NRLMSIS with data from high precision accelerometers on the Challenging Minisatellite Payload (CHAMP) and Gravity field and Circulation Explorer (GOCE) satellites. The goal is to assess the use of a first principles model as a potential tool for forecasting satellite drag during large magnetic storms. For the storms considered, we found the TIEGCM, JB2008, and NRLMSIS models to be substantially more accurate than the Jacchia 71 model. The accuracies of the TIEGCM and JB2008 models were similar, but overall, the TIEGCM was more accurate. We found smaller differences for TIEGCM versus CHAMP than for NRLMIS for the Halloween Storm, and smaller differences than results published for JB2008 and the assimilative model HASDM. The empirical models are at present more practical for operational purposes, but the TIEGCM, developed as a research model, with a greater focus on operational use offers the potential for improved utility during stressing conditions.

R. L. Walterscheid↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Accuracy, Bias, and Improvements in Mapping Crops and Cropland across the United States Using the USDA Cropland Data Layer

The U.S. Department of Agriculture’s (USDA) Cropland Data Layer (CDL) is a 30 m resolution crop-specific land cover map produced annually to assess crops and cropland area across the conterminous United States. Despite its prominent use and value for monitoring agricultural land use/land cover (LULC), there remains substantial uncertainty surrounding the CDLs’ performance, particularly in applications measuring LULC at national scales, within aggregated classes, or changes across years. To fill this gap, we used state- and land cover class-specific accuracy statistics from the USDA from 2008 to 2016 to comprehensively characterize the performance of the CDL across space and time. We estimated nationwide area-weighted accuracies for the CDL for specific crops as well as for the aggregated classes of cropland and non-cropland. We also derived and reported new metrics of superclass accuracy and within-domain error rates, which help to quantify and differentiate the efficacy of mapping aggregated land use classes (e.g., cropland) among constituent subclasses (i.e., specific crops). We show that aggregate classes embody drastically higher accuracies, such that the CDL correctly identifies cropland from the user’s perspective 97% of the time or greater for all years since nationwide coverage began in 2008. We also quantified the mapping biases of specific crops throughout time and used these data to generate independent bias-adjusted crop area estimates, which may complement other USDA survey- and census-based crop statistics. Our overall findings demonstrate that the CDLs provide highly accurate annual measures of crops and cropland areas, and when used appropriately, are an indispensable tool for monitoring changes to agricultural landscapes.

54 ENVIRONMENTAL SCIENCES↗

Nuclear Data Target Accuracies for Generation-IV Systems Based on the use of New Covariance Data

A target accuracy assessment using new available covariance data, the AFCI 1.2 covariance data, has been carried out. At the same time, the more theoretical issue of taking into account correlation terms in target accuracy assessment studies has been deeply investigated. The impact of correlation terms is very significant in target accuracy assessment evaluation and can produce very stringent requirements on nuclear data. For this type of study a broader energy group structure should be used, in order to smooth out requirements and provide better feedback information to evaluators and cross section measurement experts. The main difference in results between using BOLNA or AFCI 1.2 covariance data are related to minor actinides, minor Pu isotopes, structural materials (in particular Fe56), and coolant isotopes (Na23) accuracy requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluate the impact of sensor accuracy on model performance in data-driven building fault detection and diagnostics using Monte Carlo simulation

The performance of data-driven fault detection and diagnostics (FDD) is heavily dependent on sensors. However, sensor inaccuracy and sensor faults are pervasive in building operation: inaccurate and missing sensor readings deteriorate FDD performance; sensor inaccuracy will also affect the selection of sensor for data-driven FDD in the model training process, which is another key factor of data-driven FDD performance. Sensor accuracy and sensor selection individually are well-studied research topics in this field, but the impact of sensor accuracy on sensor selection and its further impact on FDD performance has not been evaluated and quantified. In this paper, we developed a novel analysis methodology that comprehensively evaluates sensor fault on sensor selection and FDD accuracy. Monte Carlo simulation is applied to deal with multiple stochastic sensor inaccuracy and provide probabilistic analysis results of the impact of sensor inaccuracy on sensor selection and FDD accuracy. This methodology focuses on the net impact of fault states across a full sensor set. The developed methodology can be used for the early-stage sensor design and operation-stage sensor maintenance. Furthermore, a case study is conducted to demonstrate the analysis methodology using a commercial building model crated to Flexible Research Platform located at Oak Ridge National Laboratory, USA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-order numerical algorithm for DNS of low-Mach-number reactive flows with detailed chemistry and quasi-spectral accuracy

A novel and efficient algorithm is presented in this paper to deal with DNS of turbulent reacting flows under the low-Mach-number assumption, with detailed chemistry and a quasi-spectral accuracy. The temporal integration of the equations relies on an operating-split strategy, where chemical reactions are solved implicitly with a stiff solver and the convection-diffusion operators are solved with a Runge-Kutta-Chebyshev method. The spatial discretisation is performed with high-order compact schemes, and a FFT based constant-coefficient spectral solver is employed to solve a variable-coefficient Poisson equation. The numerical implementation takes advantage of the 2DECOMP&FFT libraries developed by, which are based on a pencil decomposition method of the domain and are proven to be computationally very efficient. An enhanced pressure-correction method is proposed to speed up the achievement of machine precision accuracy. It is demonstrated that a second-order accuracy is reached in time, while the spatial accuracy ranges from fourth-order to sixth-order depending on the set of imposed boundary conditions. In conclusion, the software developed to implement the present algorithm is called HOLOMAC, and its numerical efficiency opens the way to deal with DNS of reacting flows to understand complex turbulent and chemical phenomena in flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy and Precision of an IGRT Solution

Image-guided radiotherapy (IGRT) can potentially improve the accuracy of delivery of radiotherapy treatments by providing high-quality images of patient anatomy in the treatment position that can be incorporated into the treatment setup. The achievable accuracy and precision of delivery of highly complex head-and-neck intensity modulated radiotherapy (IMRT) plans with an IGRT technique using an Elekta Synergy linear accelerator and the Pinnacle Treatment Planning System (TPS) was investigated. Four head-and-neck IMRT plans were delivered to a semi-anthropomorphic head-and-neck phantom and the dose distribution was measured simultaneously by up to 20 microMOSFET (metal oxide semiconductor field-effect transmitter) detectors. A volumetric kilovoltage (kV) x-ray image was then acquired in the treatment position, fused with the phantom scan within the TPS using Syntegra software, and used to recalculate the dose with the precise delivery isocenter at the actual position of each detector within the phantom. Three repeat measurements were made over a period of 2 months to reduce the effect of random errors in measurement or delivery. To ensure that the noise remained below 1.5% (1 SD), minimum doses of 85 cGy were delivered to each detector. The average measured dose was systematically 1.4% lower than predicted and was consistent between repeats. Over the 4 delivered plans, 10/76 measurements showed a systematic error > 3% (3/76 > 5%), for which several potential sources of error were investigated. The error was ultimately attributable to measurements made in beam penumbrae, where submillimeter positional errors result in large discrepancies in dose. The implementation of an image-guided technique improves the accuracy of dose verification, particularly within high-dose gradients. The achievable accuracy of complex IMRT dose delivery incorporating image-guidance is within {+-} 3% in dose over the range of sample points. For some points in high-dose gradients, submillimeter errors in position can lead to errors > 3%. The precision of the delivery system was demonstrated to be within the experimental noise of the detector system of 1.5% (1 SD)

61 RADIATION PROTECTION AND DOSIMETRY↗

The Accuracy of Inhomogeneity Corrections in Intensity Modulated Radiation Therapy Planning in Philips Pinnacle System

The degree of accuracy of inhomogeneity corrections in a treatment planning system is dependent on the algorithm used by the system. The choice of field size, however, could have an effect on the calculation accuracy as well. There have been several evaluation studies on the accuracy of inhomogeneity corrections used by different algorithms. Most of these studies, however, focus on evaluating the dose in phantom using simplified geometry and open/static fields. This work focuses on evaluating the degree of dose accuracy in calculations involving intensity-modulated radiation therapy (IMRT) fields incident on a phantom containing both lung- and bone-equivalent heterogeneities using 6 and 10 MV beams. IMRT treatment plans were generated using the Philips Pinnacle treatment planning system and delivered to a phantom containing 55 thermoluminescent dosimeter (TLD) locations within the lung and bone and near the lung and bone interfaces with solid water. The TLD readings were compared with the dose predicted by the planning system. We find satisfactory agreement between planned and delivered doses, with an overall absolute average difference between measurement and calculation of 1.2% for the 6 MV and 3.1% for the 10 MV beam with larger variations observed near the interfaces and in areas of high-dose gradient. The results presented here demonstrate that the convolution algorithm used in the Pinnacle treatment planning system produces accurate results in IMRT plans calculated and delivered to inhomogeneous media, even in regions that potentially lack electronic equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy in contouring of small and low contrast lesions: Comparison between diagnostic quality computed tomography scanner and computed tomography simulation scanner-A phantom study

To evaluate the accuracy in detection of small and low-contrast regions using a high-definition diagnostic computed tomography (CT) scanner compared with a radiotherapy CT simulation scanner. A custom-made phantom with cylindrical holes of diameters ranging from 2-9 mm was filled with 9 different concentrations of contrast solution. The phantom was scanned using a 16-slice multidetector CT simulation scanner (LightSpeed RT16, General Electric Healthcare, Milwaukee, WI) and a 64-slice high-definition diagnostic CT scanner (Discovery CT750 HD, General Electric Healthcare). The low-contrast regions of interest (ROIs) were delineated automatically upon their full width at half maximum of the CT number profile in Hounsfield units on a treatment planning workstation. Two conformal indexes, CI{sub in}, and CI{sub out}, were calculated to represent the percentage errors of underestimation and overestimation in the automated contours compared with their actual sizes. Summarizing the conformal indexes of different sizes and contrast concentration, the means of CI{sub in} and CI{sub out} for the CT simulation scanner were 33.7% and 60.9%, respectively, and 10.5% and 41.5% were found for the diagnostic CT scanner. The mean differences between the 2 scanners' CI{sub in} and CI{sub out} were shown to be significant with p < 0.001. A descending trend of the index values was observed as the ROI size increases for both scanners, which indicates an improved accuracy when the ROI size increases, whereas no observable trend was found in the contouring accuracy with respect to the contrast levels in this study. Images acquired by the diagnostic CT scanner allow higher accuracy on size estimation compared with the CT simulation scanner in this study. We recommend using a diagnostic CT scanner to scan patients with small lesions (<1 cm in diameter) for radiotherapy treatment planning, especially for those pending for stereotactic radiosurgery in which accurate delineation of small-sized, low-contrast regions is important for dose calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration method to characterize the accuracy of phase-shifting point diffraction interferometer

Characterization of measurement accuracy of the phase-shifting point diffraction interferometer (PS/PDI) is usually performed by two-pinhole null test. In this procedure, the geometrical coma and detector tilt astigmatism systematic errors are almost one or two magnitude higher than the desired accuracy of PS/PDI. These errors must be accurately removed from the null test result to achieve high accuracy. Published calibration methods, which can remove the geometrical coma error successfully, have some limitations in calibrating the astigmatism error. In this paper, we propose a method to simultaneously calibrate the geometrical coma and detector tilt astigmatism errors in PS/PDI null test. Based on the measurement results obtained from two pinhole pairs in orthogonal directions, the method utilizes the orthogonal and rotational symmetry properties of Zernike polynomials over unit circle to calculate the systematic errors introduced in null test of PS/PDI. The experiment using PS/PDI operated at visible light is performed to verify the method. The results show that the method is effective in isolating the systematic errors of PS/PDI and the measurement accuracy of the calibrated PS/PDI is 0.0088{lambda} rms ({lambda}= 632.8 nm).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray streak camera cathode development and timing accuracy of the 4{omega} ultraviolet fiducial system at the National Ignition Facility

The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a {+-}2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4{omega} (263 nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, titanium, gold, and silver photocathode materials have been tested. Aluminum showed the highest relative quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data were analyzed to determine the centroiding statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of {+-}1.6 ps and {+-}0.7 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗