Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy and stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Climate Change and Sounder Radiometric Stability

Satellite instrument radiometric stability is critical for climate studies. The Atmospheric Infrared Sounder (AIRS) radiances are of sufficient stability and accuracy to serve as a climate data record as evidenced by comparisons with the global network of buoys. In this paper we examine the sensitivity of derived geophysical products to potential instrument radiometric stability issues due to diurnal, orbital and seasonal variations. Our method is to perturb the AIRS radiances and examine the impact to retrieved parameters. Results show that instability in retrieved temperature products will be on the same order of the brightness temperature error in the radiances and follow the same time dependences. AIRS excellent stability makes it ideal for examining impacts of instabilities of future systems on geophysical parameter performance.

Sounding↗

Regularizing the linearly extrapolated BDF2 scheme for incompressible flows with time relaxation

This paper presents a highly-efficient finite element scheme for the time relaxation model (TRM). The efficiency is achieved through the second-order BDF2 time-stepping scheme with linear extrapolation (BDF2LE). The accuracy of the scheme is also greatly enhanced through the use of the divergence-free Scott-Vogeulis finite elements, and van Cittert approximate deconvolution. A complete finite element analysis is provided, which includes rigorous proofs for the stability, well-possessedness, and convergence of both velocity and pressure solutions. Furthermore, we also demonstrate that the inclusion of the linear time relaxation term preserves the long-time stability of the unregularized BDF2LE scheme. Finally, numerical experiments are presented that demonstrate the added stability and accuracy that time relaxation can provide.

97 MATHEMATICS AND COMPUTING↗

A fourth order accurate finite difference scheme for the computation of elastic waves

A finite difference for elastic waves is introduced. The model is based on the first order system of equations for the velocities and stresses. The differencing is fourth order accurate on the spatial derivatives and second order accurate in time. The model is tested on a series of examples including the Lamb problem, scattering from plane interf aces and scattering from a fluid-elastic interface. The scheme is shown to be effective for these problems. The accuracy and stability is insensitive to the Poisson ratio. For the class of problems considered here it is found that the fourth order scheme requires for two-thirds to one-half the resolution of a typical second order scheme to give comparable accuracy.

Bayliss, A.↗

Fine tuning GPS clock estimation in the MCS

With the completion of a 24 operational satellite constellation, GPS is fast approaching the critical milestone, Full Operational Capability (FOC). Although GPS is well capable of providing the timing accuracy and stability figures required by system specifications, the GPS community will continue to strive for further improvements in performance. The GPS Master Control Station (MCS) recently demonstrated that timing improvements are always composite Clock, and hence, Kalman Filter state estimation, providing a small improvement to user accuracy.

Hutsell, Steven T.↗

Assessment of Current Global and Regional Mean Sea Level Estimates Based on the TOPEX/Poseidon Jason-1 and 2 Climate Data Record

Recent developments in Precise Orbit Determinations (POD) due to in particular to revisions to the terrestrial reference frame realization and the time variable gravity (TVG) continues to provide improvements to the accuracy and stability of the PO directly affecting mean sea level (MSL) estimates. Long-term credible MSL estimates require the development and continued maintenance of a stable reference frame, along with vigilant monitoring of the performance of the independent tracking systems used to calculate the orbits for altimeter spacecrafts. The stringent MSL accuracy requirements of a few tenths of an mm/yr are particularly essential for mass budget closure analysis over the relative short time period of Jason-l &2, GRACE, and Argo coincident measurements. In an effort to adhere to cross mission consistency, we have generated a full time series of experimental orbits (GSFC stdlllO) for TOPEX/Poseidon (TP), Jason-I, and OSTM based on an improved terrestrial reference frame (TRF) realization (ITRF2008), revised static (GGM03s), and time variable gravity field (Eigen6s). In this presentation we assess the impact of the revised precision orbits on inter-mission bias estimates, and resultant global and regional MSL trends. Tide gauge verification results are shown to assess the current stability of the Jason-2 sea surface height time series that suggests a possible discontinuity initiated in early 2010. Although the Jason-2 time series is relatively short (approximately 3 years), a thorough review of the entire suite of geophysical and environmental range corrections is warranted and is underway to maintain the fidelity of the record.

Beckley, B. D.↗

Global collocation methods for approximation and the solution of partial differential equations

Polynomial interpolation methods are applied both to the approximation of functions and to the numerical solutions of hyperbolic and elliptic partial differential equations. The derivative matrix for a general sequence of the collocation points is constructed. The approximate derivative is then found by a matrix times vector multiply. The effects of several factors on the performance of these methods including the effect of different collocation points are then explored. The resolution of the schemes for both smooth functions and functions with steep gradients or discontinuities in some derivative are also studied. The accuracy when the gradients occur both near the center of the region and in the vicinity of the boundary is investigated. The importance of the aliasing limit on the resolution of the approximation is investigated in detail. Also examined is the effect of boundary treatment on the stability and accuracy of the scheme.

Solomonoff, A.↗

The Effect of Companions on the SIM Reference Frame

The Space Interferometry Mission (SIM) is a 10-m Michelson space-based optical interferometer designed for precision astrometry (4 microarcseconds, 3 microarcseconds/year) with better accuracy than before over a narrow field of view. One of the primary objectives of the SIM instrument is to determine accurately the directions to a grid of stars, together with their proper motions and parallax, improving a priori knowledge by nearly three orders of magnitude over Hipparcos and one order of magnitude over FAME's planned accuracy (Johnston, 2000). The instrument does not measure directly the angular separation between stars, but rather it measures the projection of each star's direction vector onto the interferometer baseline vector by measuring the pathlength delay of starlight as it passes through the two arms of the interferometer. The accuracy and stability of SIM's celestial reference frame is subject to degradation over the 5-year mission from the reflex motion induced by massive companions of the objects used to construct the celestial reference frame. The authors present the results of simulations that show the sensitivity of reference frame accuracy to companions as a function of mass and period. They assume that pre-launch ground surveys will eliminate all objects with RMS radial velocity greater than 10 m/s. They further assume that the standard astrometric parameters of position, parallax, and proper motion plus acceleration terms in right ascension and declination will be allowed to absorb reflex motion.

ASTROMETRY↗

Skin Sea‐Surface Temperature from VIIRS on Suomi‐NPP—NASA Continuity Retrievals

Retrievals of skin Sea‐Surface Temperature (SSTskin) from the measurements of the Visible Infrared Imaging Radiometer Suite on the Suomi‐National Polar‐orbiting Partnership satellite are presented and discussed. The algorithms used to derive the SSTskin from the radiometric measurements are given in detail. A number of approaches to assess the accuracy and stability of the Visible Infrared Imaging Radiometer Suite (VIIRS) SSTskin retrievals are reported, and factors including latitude and season, and physical processes in the atmosphere and at the surface are discussed. We conclude that the Suomi National Polar‐orbiting Partnership (S‐NPP) VIIRS is capable of matching and improving upon the accuracies of SSTskin from the MODISs on Terra and Aqua, and that the VIIRS SSTskin fields have the potential to contribute to the extension of the satellitederived Climate Data Records of SST into the future.

sea‐surface temperature↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

An Examination of the Recent Stability of Ozonesonde Global Network Data

The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post-2013 TCO “dropoff” of ~3-4% that was reported previously at select stations (Stauffer et al., 2020). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.

Ryan M. Stauffer↗

A microprocessor-controlled CCD star tracker

The STELLAR (Star Tracker for Economical Long Life Attitude Reference) utilizes an image sensing Charge-Coupled Device (CCD) operating under microprocessor control. This approach results in a new type of high-accuracy star tracker which can be adapted to a wide variety of different space flight applications through software changes only. The STELLAR determines two-axis star positions by computing the element and the interelement interpolated centroid positions of the star images. As many as 10 stars may be tracked simultaneously, providing significantly increased stability and accuracy. A detailed description of the STELLAR is presented along with measurements of system performance obtained from an operating breadboard model.

Salomon, P. M.↗

Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology

This work focused on developing, fabricating, and fully calibrating a flowangle probe for aeronautics research by utilizing the latest microelectromechanical systems (MEMS), leadless silicon on insulator (SOI) sensor technology. While the concept of angle probes is not new, traditional devices had been relatively large due to fabrication constraints; often too large to resolve flow structures necessary for modern aeropropulsion measurements such as inlet flow distortions and vortices, secondary flows, etc. Mea surements of this kind demanded a new approach to probe design to achieve sizes on the order of 0.1 in. (.3 mm) diameter or smaller, and capable of meeting demanding requirements for accuracy and ruggedness. This approach invoked the use of stateof- the-art processing techniques to install SOI sensor chips directly onto the probe body, thus eliminating redundancy in sensor packaging and probe installation that have historically forced larger probe size. This also facilitated a better thermal match between the chip and its mount, improving stability and accuracy. Further, the leadless sensor technology with which the SOI sensing element is fabricated allows direct mounting and electrical interconnecting of the sensor to the probe body. This leadless technology allowed a rugged wire-out approach that is performed at the sensor length scale, thus achieving substantial sensor size reductions. The technology is inherently capable of high-frequency and high-accuracy performance in high temperatures and harsh environments.

Ned, Alex↗

Uses of the ICRF and implications for future VLBI

Since its inception on 1 Jan 1998, the fundamental ICRF has been set by the VLBI positions of 212 "defining" extragalactic radio sources. In all there are approx.3000 sources with usefully accurate (< few mas) positions consistent with the ICRF. The uses of the ICRF include fundamental astrometry, monitoring of Earth orientation, and spacecraft navigation. For fundamental astrometry, stability and accuracy are most important, and realizations at different frequencies must be in proper registration. However, there is no preferred frequency, and the GAIA mission has the potential for an optical ICRF with 500,000 objects at the 50 microarcsec level some time after the planned 2011 launch. The radio ICRF should be properly prepared for a transition to assure long term stability and consistency. Earth orientation monitoring requires objects attached to the solid Earth, and VLBI will continue to be the fundamental technique. For this purpose it is essential that the new VLBI stations contemplated in the VLBI20l0 report be capable of observing a sufficiently large and well-distributed set of stable sources, and identifying these sources is an on-going effort. Spacecraft navigation by differential VLBI is planned using the Ka-band telemetry signal, and work has begun towards an ICRF realization suitable for this purpose. The balancing of different needs related to the VLBI ICRF will be discussed.

Ma, Chopo↗

Microwave tunable laser source: A stable, precision tunable heterodyne local oscillator

The development and capabilities of a tunable laser source utilizing a wideband electro-optic modulator and a CO2 laser are described. The precision tunability and high stability of the device are demonstrated with examples of laboratory spectroscopy. Heterodyne measurements are also presented to demonstrate the performance of the laser source as a heterodyne local oscillator. With the use of five CO2 isotope lasers and the 8 to 18 GHz sideband offset tunability of the modulator, calculations indicate that 50 percent spectral coverage in the 9 to 12 micron region is achievable. The wavelength accuracy and stability of this laser source is limited by the CO2 laser and is more than adequate for the measurement of narrow Doppler-broadened line profiles. The room-temperature operating capability and the programmability of the microwave tunable laser source are attractive features for its in-the-field implementation. Although heterodyne measurements indicated some S/N degradation when using the device as a local oscillator, there does not appear to be any fundamental limitation to the heterodyne efficiency of this laser source. Through the use of a lower noise-figure traveling wave tube amplifier and optical matching of the output beam with the photomixer, a substantial increase in the heterodyne S/N is expected.

Sachse, G. W.↗

Accurate in vivo tumor detection using plasmonic-enhanced shifted-excitation Raman difference spectroscopy (SERDS)

For the majority of cancer patients, surgery is the primary method of treatment. In these cases, accurately removing the entire tumor without harming surrounding tissue is critical; however, due to the lack of intraoperative imaging techniques, surgeons rely on visual and physical inspection to identify tumors. Surface-enhanced Raman scattering (SERS) is emerging as a non-invasive optical alternative for intraoperative tumor identification, with high accuracy and stability. However, Raman detection requires dark rooms to work, which is not consistent with surgical settings. Methods: Herein, we used SERS nanoprobes combined with shifted-excitation Raman difference spectroscopy (SERDS) detection, to accurately detect tumors in xenograft murine model. Results: We demonstrate for the first time the use of SERDS for in vivo tumor detection in a murine model under ambient light conditions. We compare traditional Raman detection with SERDS, showing that our method can improve sensitivity and accuracy for this task. Conclusion: Our results show that this method can be used to improve the accuracy and robustness of in vivo Raman/SERS biomedical application, aiding the process of clinical translation of these technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Explicit Discontinuous Galerkin Methods for Conservation Laws

The two explicit DG methods in this study are based on a ‘predictor-corrector’ formulation, the first introduced by Lörcher, Gassner, and Munz (2007, 2008) called space–time expansion discontinuous Galerkin or STE-DG scheme, and the second, introduced independently by the author (Huynh 2006, 2013) called the upwind moment scheme. The predictor step of the two methods is essentially identical using a Cauchy-Kovalevsky (CK) procedure, which involves no interaction of the data among neighboring cells. The corrector step also shares the same space-time integration formulation and is where interaction of the data among neighboring cells takes place; the difference, however, is in how the resulting space-time volume integral is estimated. As a consequence of the different estimates, for the case of advection in one spatial dimension (1D), the moment scheme has a CFL (Courant-Friedrichs-Lewy) condition of 1 for all p and is accurate to order 2p+1, i.e., it possesses the super accuracy property, whereas the STE-DG method has a more restrictive CFL condition and is accurate to the expected order of p+1. For 1D advection, compared with the CFL conditions of 1/(2p+1) of standard RK-DG (Runge-Kutta) scheme where space and time discretization are of the same order, the moment scheme allows a significantly larger time step size. It also turns out that the scheme yields a result identical to Van Leer’s scheme III (1977), which amounts to shifting the data a distance of advection corresponding to the time step and projecting the result onto the space of polynomial solutions. Contrary to Van Leer’s approach, however, the space-time ‘predictor-corrector’ formulation facilitates extensions to the case of systems of equations. Concerning 2D extensions, in the case of advection, when the flow is along the diagonal direction, the CFL conditions for the moment schemes become restrictive as will be shown by Fourier (Von Neumann) stability and accuracy analyses. Since the moment scheme employs the right Radau points as collocation points in time, the method is closely related to the implicit Radau IIA scheme, which is stable for any time step size. The role of Radau IIA in relieving stability restriction for these explicit DG schemes remains to be explored

Discontinuous Galerkin↗

A Reconstruction Approach to High-Order Schemes Including Discontinuous Galerkin for Diffusion

We introduce a new approach to high-order accuracy for the numerical solution of diffusion problems by solving the equations in differential form using a reconstruction technique. The approach has the advantages of simplicity and economy. It results in several new high-order methods including a simplified version of discontinuous Galerkin (DG). It also leads to new definitions of common value and common gradient quantities at each interface shared by the two adjacent cells. In addition, the new approach clarifies the relations among the various choices of new and existing common quantities. Fourier stability and accuracy analyses are carried out for the resulting schemes. Extensions to the case of quadrilateral meshes are obtained via tensor products. For the two-point boundary value problem (steady state), it is shown that these schemes, which include most popular DG methods, yield exact common interface quantities as well as exact cell average solutions for nearly all cases.

Huynh, H. T.↗

Developing reliable machine learning interatomic potential for Fe–Cr–Ni austenitic alloys

Gaining atomistic understanding of mechanical behavior of heat-resistant structural materials such as Fe–Cr–Ni-based alloys requires an approach with an accuracy close to density functional theory (DFT) that considers the intrinsic properties of the bulk lattice and important defects such as stacking faults, grain boundaries, and surfaces. This work aims to develop reliable machine learning interatomic potential (MLIAP) at cross-scale for Fe–Cr–Ni ternary alloys with a focus on the face-centered-cubic (fcc) solid solution structure. Leveraging the advantages of moment tensor potentials, which typically necessitate a relatively small training dataset and enable rapid calculations using the large-scale atomic/molecular massively parallel simulator package, we ensure the stability and accuracy of the trained potentials. Important defects such as stacking faults, grain boundaries, and surfaces for wide-range compositions are investigated. Structural, thermal, elastic, and defect properties are determined from molecular dynamics simulations comprising several thousand atoms, generated via canonical Monte Carlo simulations guided by the trained potential. The trained potential allows efficient atomic simulations of structural, thermal, and mechanical properties of fcc Fe–Cr–Ni solid solution alloys as a function of composition and temperature. Therefore, the MLIAP approach represents a major advancement from DFT calculations that are limited to small simulation sizes and traditional molecular dynamics simulations using relatively low accuracy potentials. Furthermore, this work outlines a practical foundation for further investigating the structural evolution and mechanical behavior of austenitic stainless steel and nickel-based alloys in a wide array of applications in extreme environments.

Crystal structure↗