Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Mass flow rate effect on a rotating detonation combustor with an axial air injection

Changing the flow rate of reactants being injected into a rotating detonation combustor (RDC) results in interesting behavior of the system. Prior studies have found that an increase in mass flow rate gradually increases the detonation wave speed before splitting the wave into multiple fronts. Here, the focus of this study is in understanding the physics of such behavior through a combination of experiments and numerical simulations. For this purpose, the axial air inlet-based RDC geometry is used. In the experiments, the wave velocity increased similar to prior studies. Corresponding full-scale simulations show that increase in mass flow rate by increasing pressure of the feed plenums shortens the recovery time of the injectors. This causes a more uniform fuel–air mixture to form prior to the arrival of the detonation wave. As a result, a more ideal detonation is observed, which leads to an increased wave velocity. Details of the detonation structure and variation with mass flow rate are analyzed. The presence and variation of the different deflagration zones in such non-premixed RDCs are also discussed.

42 ENGINEERING↗

Strong adsorption of guanidinium cations to the air–water interface

Combining Deep-UV second harmonic generation spectroscopy with molecular simulations, we confirm and quantify the specific adsorption of guanidinium cations to the air–water interface. Using a Langmuir analysis of measurements at multiple concentrations, we extract the Gibbs free energy of adsorption, finding it larger than typical thermal energies. Molecular simulations clarify the role of polarizability in tuning the thermodynamics of adsorption, and establish the preferential parallel alignment of guanidinium at the air–water interface. As a polyatomic cation, guanidinium represents one of the few examples of a positively charged species to exhibit a propensity for the air-water interface. As such, these results expand on the growing body of work on specific ion adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reorganization of Water at Aqueous Aluminum Chloride (AlCl 3 ) Interfaces: Vibrational Sum Frequency Generation and Molecular Dynamics Simulations

AlCl 3 hydration states and complexation are not well understood both in solutions and at the air–aqueous interface despite their potential significance in natural waters and their industrial and energy-related applications. Here, we investigated Al 3+ and Cl – ion behaviors in an AlCl 3 aqueous bulk solution and at the air–aqueous interface using interface-selective vibrational sum frequency generation (SFG), Raman and infrared spectroscopies, molecular dynamics (MD) simulation, as well as molecular-informed reduced modeling. Our reduced modeling reveals relatively long-range effects for Al 3+ as compared to monovalent ions such as Na + indicating that the interfacial depth of trivalent ions can be significantly larger than that of monovalent ions at the air–water interface. MD simulations reveal interfacial stratification and multiple layering of the ions. Compression of the Al 3+ and Cl – distributions with increasing concentrations from 0.5 to 2.5 m is also observed in the subsurface regions. Significant SSP- and PPP-polarized SFG OH spectral intensity increases are observed from 0.5 to 1.5 m and 0.5 to 2.5 m, respectively, indicative of interfacial depth increases and a change in average orientation above 1.5 m. Extensive evaluation of SFG spectra, Fresnel-corrected using several approaches, shows the same trends. The nonmonotonic trend points to a changing structure in surface and subsurface water orientation and hydrogen bonding environment generally consistent with the MD simulation of stratification and water orientation changes. Furthermore, solvent-shared ion pairing is implicated with MD simulation radial distribution analysis and consistent with infrared spectral identification of the hexaaqua aluminum ion in the solution phase. Spectral evidence of a strong Al 3+ hydration shell and the acidic behavior of the Al 3+ ions is obvious in the Raman and infrared spectra of the bulk solution. In conclusion, we show that the MD dipole potential is directly related to the MD second-order susceptibility of the interface, χ SFG–MD (2) , both of which correlate up to ∼35 Å with the spectral observations of increasing and then saturating intensities, suggesting that both ion stratification and interfacial depth determine the water orientations at an air–water interface of 1-3 electrolyte solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micromovements and discomfort associated with flight mission with helmet operation tasks with different levels of cognitive workload

When performing stationary tasks under elevated cognitive workload, individuals must perform continual muscle contractions to maintain stability of the body, resulting in fatigue of the postural muscles. When the muscles perform these contractions in a prolonged manner, the body potentially responds through small changes in body movements—micromovements that may lead to discomfort. The study purpose was to evaluate impact of cognitive load on micromovements. The micromovements were measured during three different cognitive workloads; low, medium, and high. The NASA-TLX score was used to evaluate the perceived mental workload and discomfort was assessed by visual analog scale. In total, 60 subjects (30 males and 30 females) were recruited and performed cognitive tasks that simulated flight operations such as changing the radio frequency based on air traffic control messages, balancing the fuel levels in simulated fuel tanks, and aiming a reticle in a designated moving target using the cyclic control. Cognitive load was defined by the frequency of events. Micromovements were defined by changes in the center of pressure (COP) of the seat pan and COP standard deviation. It was found that the high cognitive workloads had the highest NASA-TLX scores including mental demands, temporal demands, and effort. The neck area had the highest overall levels of discomfort followed by upper back. The highest standard deviation for COP shift and number of micromovements occurred for medium cognitive workloads. In conclusion, while there were some interesting trends, few trends reached a statistical significance due to high variability among subjects for the outcome variables.

60 APPLIED LIFE SCIENCES↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Effects of molar expansion ratio of fuels on engine efficiency

Fuel properties have a strong impact on the efficiency of internal combustion engines. Contrary to other physical and thermochemical fuel properties, the molar expansion ratio is normally ignored. Molar expansion ratio is the ratio of number of moles of the products to the reactants. In this work, the impact of the fuel’s molar expansion ratio on engine efficiency is investigated. Findings are based on simulations of a spark ignition engine using different fuels (standard fuels and user-defined fuels) and different dilution ratios. Simulations without heat transfer and friction were performed first. The combustion then takes place at top dead center with a very short combustion duration to approach the ideal Otto cycle. The heat transfer and friction were then added step by step. From this analysis, it could be concluded that the heat loss and friction work decrease as molar expansion ratio increases. The gross indicated and brake thermal efficiencies thus increase. User-defined fuels with different molar expansion ratio, but the same physical and thermochemical properties were then employed. The simulated results showed that the brake thermal efficiency increases by around 1.15% with an increase in molar expansion ratio of 0.02 compared to a fuel with a molar expansion ratio of unity. Lastly, the simulation was also done with air and exhaust gas recirculation dilution.

42 ENGINEERING↗

Air oxidation of yttrium hydride as a high temperature moderator for thermal neutron spectrum fission reactors

Yttrium hydride (YH x ) is an attractive moderator material for thermal neutron spectrum fission reactors requiring a small reactor core volume and has been selected as the neutron moderator for the Transformational Challenge Reactor (TCR), an advanced gas-cooled microreactor. Before YH x can be used in this application, it is important to understand the material response to off-normal conditions. In the present study, 550–650 °C isothermal dry air oxidation was performed to simulate a depressurized loss of force circulation (DLOFC) event. The oxidation was performed using thermogravimetric analysis (TGA) on bulk crack-free YHx coupons. Oxidation studies were also performed on Y coupons to elucidate the impact of H on oxidation. Both the chemistry and distribution of processing impurities were found to strongly affect oxidization behavior on a batch-to-batch basis. Regardless of batch, YHx oxidized at a significantly lower rate than Y at all temperatures, and the lower rate was directly correlated with increased hydride content. Metallic Y exhibited complex exponential kinetics, whereas YH x also exhibited complex kinetics but gained considerably less mass. According to literature reports on protonic and native-ion conductivities of Y 2 O 3 and mass spectrometry analysis of gaseous reaction products formed during the oxidation of YH x , a mechanism for the reduced oxidation rate of yttrium hydride is suggested.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Solid Particle Reactors for Nonoxidative Dehydrogenation of Ethane: Toward Solar Thermal Ethylene Production

Concentrating solar power plants can generate renewable heat at temperatures well above those of most industrial processes. Ceramic particles irradiated with concentrated sunlight can store high-quality sensible heat and transfer this to power generation systems. These concepts and materials hold great potential to also enable thermal processes in the chemical industry, but effective strategies for transferring heat from thermal energy storage media into chemical reactors are still under development. This present work evaluated the thermal and chemical compatibility of various solid particle media (including quartz, bauxite, and alumina particles) integrated directly into tube reactors and the subsequent effects on reactor performance for the nonoxidative dehydrogenation of ethane reaction. Empty tube reactors without loaded particles (representing conventional ethane cracking coils) showed significant heat transfer limitations as the tube diameter was scaled. The incorporation of media into the reactor significantly aided heat transfer to the gaseous ethane reactant and increased its conversion by as much as 10% at similar space velocities. Despite direct contact with hydrocarbon gases, alumina and quartz media showed negligible coke formation. Even during reaction in 100% ethane feed gas at 825 °C, the average selectivity of the coke product was only 0.57% when using the quartz media. These materials further demonstrated excellent thermal stability during subsequent reoxidation in air at 800 °C, which simulated the reheating of particles in a circulating particle solar receiver. Conversely, high rates of coke formation, with a product selectivity of 27.5%, were observed on sintered bauxite particles during the reaction, likely promoted by transition metal constituents. These particles fractured upon reoxidation due to exotherms generated from coke combustion. In conclusion, while the use of cofed steam could mitigate attrition of redox-active particles, the ability of inert metal oxide particles to efficiently transfer heat to concentrated ethane reactant gas while suppressing side reactions or degradation suggests that these media could effectively couple solar thermal plants to reactors for next-generation production of ethylene and other critical chemicals.

Hydrocarbons↗

Modelling Airborne Transmission and Ventilation Impacts of a COVID-19 Outbreak in a Restaurant in Guangzhou, China

Computational fluid dynamics (CFD) modelling was performed to simulate spatial and temporal airborne pathogen concentrations during an observed COVID-19 outbreak in a restaurant in Guangzhou, China. The reported seating configuration, overlap durations, room ventilation, layout, and dimensions were modelled in the CFD simulations to determine relative exposures and probabilities of infection. Results showed that the trends in the simulated probabilities of infection were consistent with the observed rates of infection at each of the tables surrounding the index patient. Alternative configurations that investigated different boundary conditions and ventilation conditions were also simulated. Increasing the fresh-air percentage to 10%, 50%, and 100% of the supply air reduced the accumulated pathogen mass in the room by an average of ~30%, ~70%, and ~80%, respectively, over 73 min. Overall, the probability of infection was reduced by ~10%, 40%, and 50%, respectively.

60 APPLIED LIFE SCIENCES↗

Multicarrier Spread Spectrum Communications With Noncontiguous Subcarrier Bands for HF Skywave Links

Existing high-frequency (HF) radio platforms offer robust performance against the volatile HF propagation channel. However, the growing traffic across the band contests the reliability of these systems. While techniques to mitigate the effects of narrowband interference have been thoroughly explored, they are insufficient against wideband interference or when the transmission band is occupied by numerous scattered users. To improve reliability in these congested channel conditions, we propose a filter-bank based multicarrier spread-spectrum waveform with noncontiguous subcarrier bands. Using noncontiguous subcarrier bands enables the system to at once leverage the robustness of a wideband system while retaining the frequency agility of a narrowband system. In this study, we modify a filter-bank transmitter structure to accommodate noncontiguous subcarrier bands and consider several immediate impacts of this change, such as elevated peak-to-average-power ratios (PAPRs). A receiver architecture to process the noncontiguous spread-spectrum signal is also introduced, along with details regarding wideband channel estimation. Finally, we develop efficient transmitter and receiver structures to support practical system implementations. We conclude by comparing the performance of contiguous and noncontiguous systems through both simulation and over-the-air testing. The results show that the noncontiguous system remains robust in typical HF channels while significantly outperforming the contiguous system in congested spectral conditions.

(PAPR↗

MIXv2: a long-term mosaic emission inventory for Asia (2010–2017)

The MIXv2 Asian emission inventory is developed under the framework of the Model Inter-Comparison Study for Asia (MICS-Asia) Phase IV and produced from a mosaic of up-to-date regional emission inventories. We estimated the emissions for anthropogenic and biomass burning sources covering 23 countries and regions in East, Southeast and South Asia and aggregated emissions to a uniform spatial and temporal resolution for seven sectors: power, industry, residential, transportation, agriculture, open biomass burning and shipping. Compared to MIXv1, we extended the dataset to 2010–2017, included emissions of open biomass burning and shipping, and provided model-ready emissions of SAPRC99, SAPRC07, and CB05. A series of unit-based point source information was incorporated covering power plants in China and India. A consistent speciation framework for non-methane volatile organic compounds (NMVOCs) was applied to develop emissions by three chemical mechanisms. The total Asian emissions for anthropogenic/open biomass sectors in 2017 are estimated as follows: 41.6/1.1 Tg NO x , 33.2/0.1 Tg SO 2 , 258.2/20.6 Tg CO, 61.8/8.2 Tg NMVOC, 28.3/0.3 Tg NH 3 , 24.0/2.6 Tg PM 10 , 16.7/2.0 Tg PM 2.5 , 2.7/0.1 Tg BC (black carbon), 5.3/0.9 Tg OC (organic carbon), and 18.0/0.4 Pg CO 2 . The contributions of India and Southeast Asia were emerging in Asia during 2010–2017, especially for SO 2 , NH 3 and particulate matter. Gridded emissions at a spatial resolution of 0.1° with monthly variations are now publicly available. This updated long-term emission mosaic inventory is ready to facilitate air quality and climate model simulations, as well as policymaking and associated analyses.

54 ENVIRONMENTAL SCIENCES↗

Polyamine phosphorus dendrimer materials for carbon dioxide capture

The present disclosure provides novel solid sorbents synthesized by the reaction of polyamines with polyaldehyde phosphorous dendrimer (P-dendrimer) compounds. The sorbents are highly stable and exhibit rapid reaction kinetics with carbon dioxide, making the sorbents applicable for carbon capture, and can be easily regenerated for further use. The material is stable to aqueous and organic media, as well as strong acid and bases. The sorbent maintains full capacity over extended use. The material can be used for CO2 capture from pure CO2 streams, mixed gas streams, simulated flue gas, and ambient air. Additionally, the material can be adhered to surfaces for reversible CO2 capture applications outside of bulk particle-based processes.

Thompson, III, Samuel John↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process-based and observation-constrained SOA simulations in China: the role of semivolatile and intermediate-volatility organic compounds and OH levels

Organic aerosol (OA) is a major component of tropospheric submicron aerosol that contributes to air pollution and causes adverse effects on human health. Chemical transport models have difficulties in reproducing the variability in OA concentrations in polluted areas, hindering understanding of the OA budget and sources. Herein, we apply both process-based and observation-constrained schemes to simulate OA in GEOS-Chem. Comprehensive data sets of surface OA, OA components, secondary organic aerosol (SOA) precursors, and oxidants were used for model–observation comparisons. The base models generally underestimate the SOA concentrations in China. In the revised schemes, updates were made on the emissions, volatility distributions, and SOA yields of semivolatile and intermediate-volatility organic compounds (SVOCs and IVOCs) and additional nitrous acid sources. With all the model improvements, both the process-based and observation-constrained SOA schemes can reproduce the observed mass concentrations of SOA and show spatial and seasonal consistency with each other. Our best model simulations suggest that anthropogenic SVOCs and IVOCs are the dominant source of SOA, with a contribution of over 50% in most of China, which should be considered for pollution mitigation in the future. The residential sector may be the predominant source of SVOCs and IVOCs in winter, despite large uncertainty remaining in the emissions of IVOCs from the residential sector in northern China. The industry sector is also an important source of IVOCs, especially in summer. More SVOC and IVOC measurements are needed to constrain their emissions. Besides, the results highlight the sensitivity of SOA to hydroxyl radical (OH) levels in winter in polluted environments. The addition of nitrous acid sources can lead to over 30% greater SOA mass concentrations in winter in northern China. It is important to have good OH simulations in air quality models.

54 ENVIRONMENTAL SCIENCES↗

NUMERICAL INVESTIGATION OF AIR DEHUMIDIFICATION THROUGH WATER DROPLETS DIELECTROPHORESIS

This paper numerically investigated the dehumidification of moist airflow in a converging rectangular duct with electrically enhanced condensation. The aim was to develop a condensation model that predicted water vapor condensation by employing the dielectrophoresis principle. The charged droplets were injected into the computational domain to produce a gradient electric field. The dielectrophoretic interaction between the droplets and vapor molecules of the humid air resulted in local water vapor condensation at the vapor and liquid droplet interface. This phenomenon is described in detail in this paper. A hybrid Eulerian-Lagrangian solver SprayFoam was developed based on OpenFOAM® to simulate condensation in two-phase gas-liquid mixtures. The following developments were made based on the standard compressible multiphase flow solver SprayFoam in OpenFOAM®: (1) Eulerian solver for gas phase (2) multi-component species transport, and (3) Lagrangian solver for gas-droplet two-phase flows and sub-models for liquid droplets. The newly developed numerical model was experimentally validated with data from a series of tests conducted in the authors' laboratory. The results showed that the simulations followed the same trends as the data, and the model predicted the condensation due to the electro-spray injection process in the air stream. The injected water droplets, which are electrically charged to their Rayleigh limits, increased in size while wiping out the humidity from the air. The simulations indicated that the dehumidification was about 1% for 0.5 cubic feet per minute airflow rate. Scaling up to larger flows is a future follow-up work.

Yel Mahi, *Maliha↗