Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Reaction losses of charged particles in CsI(Tl) crystals

To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei within the detector and for the scattering of incident particles out of the detector, without depositing their full energy in the active material. In this paper, we develop a method for measuring such corrections and determine the reaction and out-scattering losses for data measured with the silicon-CsI(Tl) telescopes of the newly developed HiRA10 array. Here, the extracted efficiencies are in good agreement with model predictions using the GEANT4 reaction loss algorithm for Z = 1 and Z = 2 isotopes. After correcting for the HiRA10 geometry, we obtain a general function that describes the loss of efficiency due to reaction losses in CsI(Tl) crystals as a function of range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-BRC-06: OpenCL-Based Cross-Platform Monte Carlo Simulation Package for Carbon Ion Therapy

Purpose: Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and fundamental physical quantities related to biological effects in carbon ion therapy. Its long computation time impedes clinical and research applications. We have developed an MC package, goCMC, on parallel processing platforms, aiming at achieving accurate and efficient simulations for carbon therapy. Methods: goCMC was developed under OpenCL framework. It supported transport simulation in voxelized geometry with kinetic energy up to 450 MeV/u. Class II condensed history algorithm was employed for charged particle transport with stopping power computed via Bethe-Bloch equation. Secondary electrons were not transported with their energy locally deposited. Energy straggling and multiple scattering were modeled. Production of secondary charged particles from nuclear interactions was implemented based on cross section and yield data from Geant4. They were transported via the condensed history scheme. goCMC supported scoring various quantities of interest e.g. physical dose, particle fluence, spectrum, linear energy transfer, and positron emitting nuclei. Results: goCMC has been benchmarked against Geant4 with different phantoms and beam energies. For 100 MeV/u, 250 MeV/u and 400 MeV/u beams impinging to a water phantom, range difference was 0.03 mm, 0.20 mm and 0.53 mm, and mean dose difference was 0.47%, 0.72% and 0.79%, respectively. goCMC can run on various computing devices. Depending on the beam energy and voxel size, it took 20∼100 seconds to simulate 10{sup 7} carbons on an AMD Radeon GPU card. The corresponding CPU time for Geant4 with the same setup was 60∼100 hours. Conclusion: We have developed an OpenCL-based cross-platform carbon MC simulation package, goCMC. Its accuracy, efficiency and portability make goCMC attractive for research and clinical applications in carbon therapy.

60 APPLIED LIFE SCIENCES↗

Evaluation & Development of Algorithms & Techniques for Streaming Detector Readout

The advancement in microelectronics capabilities, computing, and data science in the last decade has been remarkable. With the start of the 12 GeV Science Program at Jefferson Lab (JLab) and the conceptual detector design for the upcoming Ion Collider (EIC) in mind, we have evaluated and developed the possibility of evolving and improving the existing nuclear science research workflow based on these advances. Specifically, we have prototyped components of streaming readout.

43 PARTICLE ACCELERATORS↗

Attenuation correction in emission tomography using the emission data—A review

The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy deficiencies of purely MRI-based AC approaches in PET/MRI and improve standalone PET imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Machine-Learning Enabled Evaluation of Probability of Piping Degradation In Secondary Systems of Nuclear Power Plants

The transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, technologies used to perform online monitoring of piping and other secondary system structural components in commercial nuclear power plants (NPPs) are under evaluation. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval thus reducing the maintenance cost. This paper describes distributed high-temperature stable fiber sensors fabricated in optical fibers through a roll-to-roll laser direct writing process using femtosecond lasers. Using phase-sensitive optical time domain reflectometry, distributed acoustic and vibration sensors can be developed and deployed to critical components and systems in NPPs to perform active measurements with spatial resolution down to 0.5-meter throughout the piping systems. Complex acoustic and vibration signatures harnessed by distributed sensors are registered and analyzed by artificial intelligence algorithms for degradation detection and flaw identification. Piping elbows with machined-in flaws were instrumented with fiber sensors. High-spatial-resolution data were used to develop and validate machine learning algorithms, including both linear and nonlinear regression, and classification. Additionally, classification and sensor analysis were also performed for data analysis. The paper concludes with recommendations and future work on applications of machine learning enabled high-resolution fiber sensors for piping degradation monitoring in current or future NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix phased array (MPA) imaging technology for resistance spot welds

A three-dimensional MPA probe has been incorporated with a high speed phased array electronic board to visualize nugget images of resistance spot welds. The primary application area of this battery operated portable MPA ultrasonic imaging system is in the automotive industry which a conventional destructive testing process is commonly adopted to check the quality of resistance spot welds in auto bodies. Considering an average of five-thousand spot welds in a medium size passenger vehicle, the amount of time and effort given to popping the welds and measuring nugget size are immeasurable in addition to the millions of dollars' worth of scrap metals recycled per plant per year. This wasteful labor intensive destructive testing process has become less reliable as auto body sheet metal has transitioned from thick and heavy mild steels to thin and light high strength steels. Consequently, the necessity of developing a non-destructive inspection methodology has become inevitable. In this paper, the fundamental aspects of the current 3-D probe design, data acquisition algorithms, and weld nugget imaging process are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements to Rad/Nuke Search Algorithms, RSLA-004-17, Year 1 of 1

This presentation describes investigation into new ways to improve the radiological/nuclear detection performance (gamma ray and neutron) in deployed emergency response equipment and to develop a more efficient and effective use of advanced algorithms, including spectral anomaly detection schemes that are designed to exploit modern-day enhancements to sensors, data quality, and computing resources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing standard performance testing procedures for material control and accounting components at a site

The condition of a nuclear material control and accountability system (MC&A) and its individual components, as with any system combining technical elements and documentation, may be characterized through an aggregate of values for the various parameters that determine the system's ability to perform. The MC&A system's status may be functioning effectively, marginally or not functioning based on a summary of the values of the individual parameters. This work included a review of the following subsystems, MC&A and Detecting Material Losses, and their respective elements for the material control and accountability system: (a) Elements of the MC&A Subsystem - Information subsystem (Accountancy/Inventory), Measurement subsystem, Nuclear Material Access subsystem, including tamper-indicating device (TID) program, and Automated Information-gathering subsystem; (b) Elements for Detecting Nuclear Material Loses Subsystem - Inventory Differences, Shipper/receiver Differences, Confirmatory Measurements and differences with accounting data, and TID or Seal Violations. In order to detect the absence or loss of nuclear material there must be appropriate interactions among the elements and their respective subsystems from the list above. Additionally this work includes a review of regulatory requirements for the MC&A system component characteristics and criteria that support the evaluation of the performance of the listed components. The listed components had performance testing algorithms and procedures developed that took into consideration the regulatory criteria. The developed MC&A performance-testing procedures were the basis for a Guide for MC&A Performance Testing at the material balance areas (MBAs) of State Scientific Center of the Russian Federation - Institute for Physics and Power Engineering (SSC RF-IPPE).

78↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Acoustic Model-Based Iterative Reconstruction Technique for Thick-Concrete Imaging

Ultrasound signals have been used extensively for non-destructive evaluation (NDE). However, typical reconstruction techniques, such as the synthetic aperture focusing technique (SAFT), are limited to quasi-homogenous thin media. New ultrasonic systems and reconstruction algorithms are in need for one-sided NDE of non-homogenous thick objects. An application example space is imaging of reinforced concrete structures for commercial nuclear power plants (NPPs). These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Another example is geothermal and oil/gas production wells. These multi-layered structures are composed of steel, cement, and several types of soil and rocks. Ultrasound systems with greater penetration range and image quality will allow for better monitoring of the well's health and prediction of high-pressure hydraulic fracturing of the rock. These application challenges need to be addressed with an integrated imaging approach, where the application, hardware, and reconstruction software are highly integrated and optimized. Therefore, we are developing an ultrasonic system with Model-Based Iterative Reconstruction (MBIR) as the image reconstruction backbone. As the first implementation of MBIR for ultrasonic signals, this paper document the first implementation of the algorithm and show reconstruction results for synthetically generated data.

concrete NDE↗

Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry

The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al{sub 2}O{sub 3}:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties, instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of coincidence-based PSD on LiF/ZnS Detectors for Multiplicity Counting

Abstract: Mass accountancy measurement is a nuclear nonproliferation application which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. With a well-designed and efficient detector system, several relevant parameters of the material can be verified simultaneously. 6LiF/ZnS scintillating sheets may be used for this purpose due to a combination of high efficiency and short die-away times in systems designed with this material, but involve choices of detector geometry and exact material composition (e.g., the addition of Ni-quenching in the material) that must be optimized for the application. Multiplicity counting for verification of declared nuclear fuel mass involves neutron detection in conditions where several neutrons arrive in a short time window, with confounding gamma rays. This paper considers coincidence-based Pulse-Shape Discrimination (PSD) techniques developed to work under conditions of high pileup, and the performance of these algorithms with different detection materials. Simulated and real data from modern LiF/ZnS scintillator systems are evaluated with these techniques and the relationship between the performance under pileup and material characteristics (e.g., neutron peak width and total light collection efficiency) are determined, to allow for an optimal choice of detector and material.

Robinson, Sean M.↗

Development of a Neutron List Mode Collar (LMCL) and a List Mode Response Matrix Analysis Concept

This report was prepared for the Safeguards Program of the US Department of Energy’s (DOE’s) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The report presents the development of the neutron nondestructive assay system, the List Mode Collar (LMCL) for the project OR16-List Mode for Collar-PD1La “List Mode Response Matrix for Advanced Correlated Neutron Analysis for Nuclear Safeguards.” The new list mode electronics developed under this project, and a spatial analysis concept called the List Mode Response Matrix are also described in this report. Analysis algorithms based on classification methods are published in a separate report. This research addresses the need to expand the capabilities of current nondestructive assay systems used for nuclear safeguards applications and considers the sustainability of safeguards technologies by the development of a “retrofit” concept using electronics based on modern standards. Furthermore, employing list mode data acquisition enabled the development of a spatial analysis concept and empirical measurement of a spatial response not previously used for safeguards neutron counting applications or measured in a traditional neutron collar detector and, therefore, provides new capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing standard performance testing procedures for MC&A components at a site

The condition of a nuclear material control and accountability system (MC&A) and its individual components, as with any system combining technical elements, documentation and the human factor, may be characterized through an aggregate of values for the various parameters that determine the system's ability to perform. The MC&A system's status may be functioning effectively, marginally or not functioning based on a summary of the values of the individual parameters. This work included a review of the following elements and subsystems or components for a material control and accountability system: (1) MC&A Elements: Information subsystem, Measurement subsystem, NM access subsystem, including a tamper-indicating device (TID) program, and Automated information-gathering subsystem; and (2) Detecting NM Loses Elements: Inventory differences, Shipper/receiver differences, Confirmatory measurements and differences with accounting data, and TID or seal violations. In order to detect the absence or loss of nuclear material there must be appropriate interactions among the elements and their respective subsystems (from the list above). Additionally this work includes a review of the status of regulatory requirements for the MC&A system components and potential criteria that support the evaluation of the performance of the listed components. The listed components had performance testing algorithms and procedures developed that took into consideration the regulatory criteria. The developed MC&A performance-testing procedures were the basis for a pilot Guide for MC&A Performance Testing at the MBAs of SSC RF IPPE.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Signal Decomposition for Intrusion Detection in Reliability Assessment in Cyber Resilience (Summary Report)

The complexity of assuring cyber resilience for physical process interactions in connected systems such as energy grids increases dramatically as the coupling between processes becomes more direct and responsive. An example of this growing complexity is provided by Integrated Energy Systems (IES), in which various processes such as nuclear heat generation and commodity production are being directly coupled for increased responsiveness to highly variable signals such as market pricing or electricity demand. As such, the potential attack surface of the coupled processes is larger than the two processes independently. Securing these complex systems requires two-fold monitoring: cybersecure monitoring for potential malicious incursion, and physics monitoring for system tampering. Physics monitoring includes analyzing the behavior of the signals within the system for anomalous behavior. This analysis has been shown to be insufficient if approached by only data-driven machine learning and artificial intelligence (MLAI) techniques or only low-level model comparison. Previous efforts at Purdue University suggested combining high-fidelity models with MLAI algorithms as a basis for a software tool for detecting anomalies in physical processes. This work built on that suggestion, developing an advanced library for signal decomposition and analysis using both MLAI and high-fidelity physics algorithms for greatly improved anomaly detection, especially false data injection. This software can be used as part of a secure imbedded intelligence (SEI) system designed under Consequence-driven Cyber-informed Engineering (CCE) for complex coupled systems. This library established a foundation for online and posteriori analysis of digital signals for the purpose of detecting potential malicious tampering in digital signals representing physical processes. Demonstrations carried out throughout the development highlight the effective use of characterization algorithms to detect signal perturbations, particularly triangle attack-style perturbations, in three wide-ranging applications: seismic monitoring, nuclear thermal hydraulics system simulation, and custom manufacturing.

97 MATHEMATICS AND COMPUTING↗

Analysis techniques for blob properties from gas puff imaging data

Filamentary structures, also known as blobs, are a prominent feature of turbulence and transport at the edge of magnetically confined plasmas. They cause cross-field particle and energy transport and are, therefore, of interest in tokamak physics and, more generally, nuclear fusion research. Several experimental techniques have been developed to study their properties. Among these, measurements are routinely performed with stationary probes, passive imaging, and, in more recent years, Gas Puff Imaging (GPI). In this work, we present different analysis techniques developed and used on 2D data from the suite of GPI diagnostics in the Tokamak à Configuration Variable, featuring different temporal and spatial resolutions. Although specifically developed to be used on GPI data, these techniques can be employed to analyze 2D turbulence data presenting intermittent, coherent structures. We focus on size, velocity, and appearance frequency evaluation with, among other methods, conditional averaging sampling, individual structure tracking, and a recently developed machine learning algorithm. We describe in detail the implementation of these techniques, compare them against each other, and comment on the scenarios to which these techniques are best applied and on the requirements that the data must fulfill in order to yield meaningful results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing a data-driven method to constrain the antiproton background in the Mu2e experiment

The Mu2e experiment will search for CLFV neutrinoless coherent muon to electron conversion in the field of an Al nucleus. The expected signal is a 104.97 MeV/c monochromatic $e^-$ (CE). CE-like $e^-$’s could also come from $\bar{p}$’s annihilating in the Stopping Target (ST). The background induced by $\bar{p}$’s is expected to be low but has a large systematic uncertainty. It cannot be suppressed by the time window cut used to reduce the prompt background. However, $p\bar{p}$ annihilation in the ST is the only source of events in the Mu2e detector with multiple tracks coming from the ST, simultaneous in time, each with a momentum in the signal window region. We exploited this unique feature and developed algorithms to identify and reconstruct multi-track events. This paper discusses the status and prospects of this data-driven method to constrain the $\bar{p}$ background at Mu2e.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Process Load Cell Information for IAEA Safeguards at Enrichment Plants

Uranium enrichment service providers are expanding existing enrichment plants and constructing new facilities to meet demands resulting from the shutdown of gaseous diffusion plants, the completion of the U.S.-Russia highly enriched uranium downblending program, and the projected global renaissance in nuclear power. The International Atomic Energy Agency (IAEA) conducts verification inspections at safeguarded facilities to provide assurance that signatory States comply with their treaty obligations to use nuclear materials only for peaceful purposes. Continuous, unattended monitoring of load cells in UF{sub 6} feed/withdrawal stations can provide safeguards-relevant process information to make existing safeguards approaches more efficient and effective and enable novel safeguards concepts such as information-driven inspections. The IAEA has indicated that process load cell monitoring will play a central role in future safeguards approaches for large-scale gas centrifuge enrichment plants. This presentation will discuss previous work and future plans related to continuous load cell monitoring, including: (1) algorithms for automated analysis of load cell data, including filtering methods to determine significant weights and eliminate irrelevant impulses; (2) development of metrics for declaration verification and off-normal operation detection ('cylinder counting,' near-real-time mass balancing, F/P/T ratios, etc.); (3) requirements to specify what potentially sensitive data is safeguards relevant, at what point the IAEA gains on-site custody of the data, and what portion of that data can be transmitted off-site; (4) authentication, secure on-site storage, and secure transmission of load cell data; (5) data processing and remote monitoring schemes to control access to sensitive and proprietary information; (6) integration of process load cell data in a layered safeguards approach with cross-check verification; (7) process mock-ups constructed to provide simulated load cell data; (8) hardware and software implementation for process load cell data collection; (9) costs associated with unattended monitoring of load cells (for both operator and inspector) weighed against the potential benefits of having access to such data; (10) results from field tests of load cell data collection systems in operating facilities; and (11) use of unattended load cell data to increase efficiency of on-site inspection schedules and activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗