At least 181 records · Page 10

Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗

Reliability study of opto-coupled semiconductor devices and Light Emitting Diodes (LED)

Opto-coupler and light emitting diode (LED) failure mechanisms and associated activation energies were determind from the results of environmental and accelerated lift tests of over 2,400 devices. The evaluation program included LED phototransistor opto-couplers from three sources, LED photoamplifier opto-couplers from a single source, and discrete infrared emitting LEDs from two sources. Environmental tests to evaluate device mechanical integrity included power cycling (10,000 cycles), temperature cycling (500 cycles) and a sequence of monitored shock, monitored vibration and constant acceleration. Multiple temperature operating life tests were conducted at ambient temperatures between 25 C and 200 C. Opto-couplers were operated in both the 'on' and 'off' states during life testing.

Maurer, R. C.↗

Global Fine Scale Changes in Ambient NO2 During COVID-19 Lockdowns

Nitrogen dioxide (NO2) is an important contributor to air pollution and can adversely affect human health(1–9) . A decrease in NO2 concentrations has been reported as a result of lockdown measures to reduce the spread of COVID-19(10–20). Questions remain, however, regarding the relationship of satellite-derived atmospheric column NO2 data with health-relevant ambient ground-level concentrations, and the representativeness of limited ground-based monitoring data for global assessment. Here we derive spatially resolved, global ground-level NO2 concentrations from NO2 column densities observed by the TROPOMI satellite instrument at sufficiently fine resolution (approximately one kilometre) to allow assessment of individual cities during COVID-19 lockdowns in 2020 compared to 2019. We apply these estimates to quantify NO2 changes in more than 200 cities, including 65 cities without available ground monitoring, largely in lower-income regions. Mean country-level population-weighted NO2 concentrations are 29% ± 3% lower in countries with strict lockdown conditions than in those without. Relative to long-term trends, NO2 decreases during COVID-19 lockdowns exceed recent Ozone Monitoring Instrument (OMI)-derived year-to-year decreases from emission controls, comparable to 15 ± 4 years of reductions globally. Our case studies indicate that the sensitivity of NO2 to lockdowns varies by country and emissions sector, demonstrating the critical need for spatially resolved observational information provided by these satellite-derived surface concentration estimates.

Ground level NO2↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Risk of decompression sickness in the presence of circulating microbubbles

In this study, we examined the association between microbubbles formed in the circulation from a free gas phase and symptoms of altitude decompression sickness (DCS). In a subgroup of 59 males of mean (S.D) age 31.2 (5.8) years who developed microbubbles during exposure to 26.59 kPa (4.3 psi) under simulated extravehicular activities (EVA), symptoms of DCS occurred in 24 (41 percent) individuals. Spencer grade 1 microbubbles occurred in 4 (7 percent), grade 2 in 9 (15 percent), grade 3 in 15 (25 percent), and grade 4 in 31 (53 percent) of subjects. Survival analysis using Cox proportional hazards regression showed that individuals with less than grade 3 CMB showed 2.46 times (95 percent confidence interval = 1.26 to 5.34) higher risk of symptoms. This information is crucial for defining the risk of DCS for inflight Doppler monitoring under space EVA. Altitude decompression sickness (DCS) occurs when there is acute reduction in ambient pressure. The symptoms of DCS are due to the formation of a free gas phase (in the form of gas microbubbles) in tissues during decompression. Musculo-skeletal pain of bends is the commonest form of DCS in altitude exposures. In the space flight environment, there is a risk of DCS when astronauts decompress from the normobaric shuttle pressure into the hypobaric space suit pressure (currently about 29.65 kPa (4.3 psi) for extra-vehicular activities (EVA). This risk is counterbalanced by a judicious combination of prior denitrogenation and staged decompression. Studies of DCS are limited by the duration of the test at reduced pressure. Since only a proportion of subjects tested develop symptoms, the information on DCS is generally incomplete or 'censored'. Many studies employ Doppler ultrasound monitoring of the precordial area for detecting circulating microbubbles (CMB). Although the association between CMB and bends pain is not causal, CMB are frequently monitored during decompression. In this paper, we examine the association between CMB and symptoms of DCS under simulated EVA profiles.

Kumar, K. Vasantha↗

Fast-current-heating devices to study in situ phase formation in metallic glasses by using high-energy synchrotron radiation

Details of fast-resistive-heating setups, controlled heating ranging from ~10 1 K s –1 to ~10 3 K s –1 , to study in situ phase transformations (on heating and on cooling) in metallic glasses by high-energy synchrotron x-ray diffraction are discussed here. Both setups were designed and custom built at the Leibniz Institute for Solid State and Materials Research Dresden (IFW Dresden) and have been implemented at the P02.1 Powder Diffraction and Total Scattering Beamline and the P21.1 Swedish Materials Science Beamline at PETRA III storage ring, DESY, Hamburg. The devices are interchangeable at both beamlines. Joule heating is triggered automatically and is timed with the incident beam and detector. The crystallization process can be controlled via a feedback circuit by monitoring the change in the time-dependent resistivity and temperature of glasses. Different ambient atmospheres, such as vacuum and inert gases (He and Ar), can be used to control oxidation and cooling. The main focus of these devices is on understanding the crystallization mechanism and kinetics in metallic glasses, which are brittle and for which fast heating gives defined glass–crystal composites with enhanced plasticity. As an example, phase-transformation sequence(s) in a prototyped Cu–Zr-based metallic glass is described on heating, and a crystalline phase beneficial to the plasticity is identified.

47 OTHER INSTRUMENTATION↗

Carbon dioxide/dewpoint monitor

The portable Carbon Dioxide/Dewpoint Monitor was designed to permit measurements of carbon dioxide partial pressure and dewpoint and ambient gas temperature at any place within the Saturn Workshop. It required no vehicle interface other than storage. All components necessary for operation, including battery power source, were incorporated in the instrument.

Luczkowski, S.↗

Oxidant and precursor trends in the metropolitan Los Angeles region

This paper describes recent historical trends in oxidant and precursors in the Los Angeles region. Control strategies and basinwide emission trends for nitrogen oxides and reactive hydrocarbons are documented year by year from 1965 to 1974. Trends in the geographic distribution of emissions are illustrated by computing net percentage emission changes over the decade for individual counties. The changes in emissions are compared with changes in ambient precursor concentrations and oxidant concentrations. We find that many of the changes in monitored air quality can be explained by trends in both total emissions and the spatial distribution of emissions.

Trijonis, J.↗

Cosmic ray power spectral variations. 3: Solar rotation periodicities

Earlier studies of the periodic changes in cosmic ray intensity by power spectral analysis provided some understanding of the daily variation in terms of ambient power. The solar rotation periodicities are investigated, using daily means of calgary neutron monitor data during 1965 to 1976. Significant peaks with periods of 27 and 13.5 days with varying magnitudes are observed.

Agrawal, S. P.↗

Two Air Quality Regimes in Total Column NO2 over the Gulf of Mexico in May 2019: Shipboard and Satellite Views

The Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf of Mexico was conducted in May 2019 by NASA and the Bureau of Ocean Energy Management to determine the feasibility of using satellite data to measure air quality in a region of concentrated oil and natural gas (ONG) operations. SCOAPE addressed both technological and scientific issues related to measuring NO2 columns over the Outer Continental Shelf. Featured were nitrogen dioxide (NO 2 ) instruments (Pandora, Teledyne API analyzer) at Cocodrie, LA (29.26°, -90.66°), and on the Research Vessel Point Sur operating off the Louisiana coast with measurements of ozone, carbon monoxide and volatile organic compounds (VOC). The findings: (1) All NO 2 observations revealed two atmospheric regimes over the Gulf, the first influenced by tropical air in 10-14 May, the second influenced by flow from urban areas on 15-17 May; (2) Comparisons of OMI v4 and TROPOMI v1.3 TC (total column) NO 2 data with shipboard Pandora NO 2 column observations averaged 13% agreement with the largest difference during 15-17 May (~20%). At Cocodrie, the satellite-Pandora agreement was ~5%. (3) Three new-model Pandora instruments displayed a TC NO 2 precision of 0.01 Dobson Units (~5%); (4) Regions of smaller, older natural gas operations showed high methane readings from leakage; elevated VOC were also detected. Neither satellite nor spectrometer captured the magnitude of ambient NO 2 variability near ONG platforms. Given an absence of regular air quality monitoring over the Gulf of Mexico, SCOAPE data constitute a baseline against which future observations can be compared.

Nitrogen dioxide↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Operations of the ATS-6 ion engine and plasma bridge neutralizer at geosynchronous altitude

The ion engine on ATS-6 has been operated in daylight and eclipse. The effect on particle fluxes to the spacecraft was monitored. This data provides information on the potential of the spacecraft with respect to the ambient plasma and the local electric fields caused by the charge distribution on the spacecraft. Operation of the ion engine and/or the neutralizer clamps the spacecraft within a few volts of the ambient plasma potential. Operation of only the neutralizer tends to reduce the differential charge on the satellite, whereas operation of the ion engine reduces it below the sensitivity limit of the detectors.

Olsen, R. C.↗

Absorption technique for OH measurements and calibration

An absorption technique is described which utilizes a stabilized frequency-doubled tunable dye laser and a long-path White cell with high mirror reflectivities both in the red and UV. In laboratory conditions it has been possible to routinely obtain a detection sensitivity of 3 parts in 1,000,000 over absorption paths less than 1 m in length and a detection sensitivity of approximately 6 parts in 100,000 over an absorption path of the order of 1 km. The latter number corresponds to 3,000,000 OH molecules/cu cm, and therefore the technique should be particularly useful for calibration the fluorescence instrument for OH measurements. However, the presence of atmospheric fluctuations coupled with intensity variation accompanying frequency scanning appears to degrade the detection sensitivity in outdoor ambient conditions, thus making it unlikely that this technique can be employed for direct OH monitoring.

Bakalyar, D. M.↗

Linking Asthma Exacerbation and Air Pollution Data: A Step Toward Public Health and Environmental Data Integration

Studies have shown that reducing exposure to triggers such as air pollutants can reduce symptoms and the need for medication in asthma patients. However, systems that track asthma are generally not integrated with those that track environmental hazards related to asthma. Tlvs lack of integration hinders public health awareness and responsiveness to these environmental triggers. The current study is a collaboration between health and environmental professionals to utilize NASA-derived environmental data to develop a decision support system (DSS) for asthma prediction, surveillance, and intervention. The investigators link asthma morbidity data from the University of Mississippi Medical Center (UMMC) and Mississippi Department of Health (MDH) with air quality data from the Mississippi Department of Environmental Quality (MDEQ) and remote sensing data from NASA. Daily ambient environmental hazard data for PM2.5 and ozone are obtained from the MDEQ air quality monitoring locations and are combined with remotely sensed data from NASA to develop a state-wide spatial and time series profile of environmental air quality. These data are then used to study the correlation of these measures of air quality variation with the asthma exacerbation incidence throughout the state over time. The goal is to utilize these readily available measures to allow real-time risk assessment for asthma exacerbations. GeoMedStat, a DSS previously developed for biosurveillance, will integrate these measures to monitor, analyze and report the real-time risk assessment for asthma exacerbation throughout the state.

Faruque, Fazlay↗

Surface Ozone in the Colorado Northern Front Range and the Influence of Oil and Gas Development During FRAPPE/DISCOVER-AQ in Summer 2014

High mixing ratios of ozone (O3) in the northern Front Range (NFR) of Colorado are not limited to the urban Denver area but were also observed in rural areas where oil and gas activity is the primary source of O3 precursors. On individual days, oil and gas O3 precursors can contribute in excess of 30 ppb to O3 growth and can lead to exceedances of the EPA O3 National Ambient Air Quality Standard. Data used in this study were gathered from continuous surface O3 monitors for June-August 2013-2015 as well as additional flask measurements and mobile laboratories that were part of the FRAPPE/DISCOVER-AQ field campaign of July-August 2014. Overall observed O3 levels during the summer of 2014 were lower than in 2013, likely due to cooler and damper weather than an average summer. This study determined the median hourly surface O3 mixing ratio in the NFR on summer days with limited photochemical production to be approximately 45-55 ppb. Mobile laboratory and flask data collected on three days provide representative case studies of different O3 formation environments in and around Greeley, Colorado. Observations of several gases (including methane, ethane, CO, nitrous oxide) along with O3 are used to identify sources of O3 precursor emissions. A July 23 survey demonstrated low O3 (45-60 ppb) while August 3 and August 13 surveys recorded O3 levels of 75-80 ppb or more. August 3 exemplifies influence of moderate urban and high oil and gas O3 precursor emissions. August 13 demonstrates high oil and gas emissions, low agricultural emissions, and CO measurements that were well correlated with ethane from oil and gas, suggesting an oil and gas related activity as a NOx and O3 precursor source. Low isoprene levels indicated that they were not a significant contributor to O3 precursors measured during the case studies.

Pollution↗