Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Laser Spectroscopy Multi-Gas Monitor: Results of Technology Demonstration on ISS

Tunable diode laser spectroscopy (TDLS) is an up and coming trace and major gas monitoring technology with unmatched selectivity, range and stability. The technology demonstration of the 4 gas Multi-Gas Monitor (MGM), reported at the 2014 ICES conference, operated continuously on the International Space Station (ISS) for nearly a year. The MGM is designed to measure oxygen, carbon dioxide, ammonia and water vapor in ambient cabin air in a low power, relatively compact device. While on board, the MGM experienced a number of challenges, unplanned and planned, including a test of the ammonia channel using a commercial medical ammonia inhalant. Data from the unit was downlinked once per week and compared with other analytical resources on board, notably the Major Constituent Analyzer (MCA), a magnetic sector mass spectrometer. MGM spent the majority of the time installed in the Nanoracks Frame 2 payload facility in front breathing mode (sampling the ambient environment of the Japanese Experiment Module), but was also used to analyze recirculated rack air. The capability of the MGM to be operated in portable mode (via internal rechargeable lithium ion polymer batteries or by plugging into any Express Rack 28VDC connector) was a part of the usability demonstration. Results to date show unprecedented stability and accuracy of the MGM vs. the MCA for oxygen and carbon dioxide. The ammonia challenge (approx. 75 ppm) was successful as well, showing very rapid response time in both directions. Work on an expansion of capability in a next generation MGM has just begun. Combustion products and hydrazine are being added to the measurable target analytes. An 8 to 10 gas monitor (aka Gas Tricorder 1.0) is envisioned for use on ISS, Orion and Exploration missions.

Mudgett, Paul D.↗

An experimental study of ultraviolet radiation behind incident normal shock waves in CO2 at Venusian entry speeds

Radiation intensity profiles behind incident normal shock waves in pure CO2 have been measured spectroscopically in the Langley Arc-Driven Shock Tube. These profiles, which were obtained for shock velocities between 9 and 13 km/sec and ambient densities corresponding to Venus altitudes between 100 and 80 km, were measured in the vacuum ultraviolet regime. Wavelengths of 127.7, 158.0, 177.5, and 195.0 nm were monitored simultaneously using a four-channel vacuum spectrograph equipped with sodium-salicylate-coated photomultipliers, thereby including the CO(4+) band system which is the most prominent radiator. Measured nonequilibrium overshoots are modeled to provide a means of estimating the effect of nonequilibrium radiation heating to the stagnation region of proposed aero-shells for Venusian entry. These results indicate a significant increase in radiative heating due to nonequilibrium effects. The measurements are believed to represent the most accurate data available on the effect of nonequilibrium radiative heat transfer for Venus entry. This accuracy is primarily due to improved spectrographic instrumentation, which is discussed in some detail regarding its application in related studies.

Nealy, J. E.↗

The VEGA Venus balloon experiment

In June 1985, two instrumented balloons were placed in the atmosphere of Venus as part of the VEGA mission. Each balloon traveled about 30 percent of the way around the planet at a float altitude near 54 kilometers. In situ sensors measured pressure, temperature, vertical wind velocity, cloud particle backscatter, ambient light level, and frequency of lightning. A ground-based network of 20 radio antennas tracked the balloons by very long baseline interferometry (VLBI) techniques to monitor the Venus winds. The history, organization, and principal characteristics of this international balloon experiment are described.

Sagdeev, R. Z.↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Effect of storing B-staged graphite/polyimide on fabrication of structural elements

Graphite/polyimide structural elements have been successfully fabricated by forming and curing B-staged Celion 6000/PMR-15 and Celion 6000/LaRC-160 laminates in heated matched metal tooling. The B-staged laminates were subjected to storage for various periods of time up to six months at ambient shop conditions and high humidity prior to fabrication into structural elements to determine the processability of the graphite/polyimide after exposure to these conditions. Changes in processability were monitored by measuring flexure and interlaminar shear strengths, glass transition temperature, moisture content, and formability of the B-staged laminates. No significant change in the processability of either Celion 6000/PMR or Celion 6000/LaRC-160 was recorded indicating that after B-staging the graphite/polyimide laminates can be stored for extended periods of time in normal shop and high humidity environments and then be fabricated into defect-free structural elements in heated platen presses.

Baucom, R. M.↗

Concepts and Development of Bio-Inspired Distributed Embedded Wired/Wireless Sensor Array Architectures for Acoustic Wave Sensing in Integrated Aerospace Vehicles

This paper discusses the modeling of acoustic emissions in plate structures and their sensing by embedded or surface bonded piezoelectric sensor arrays. Three different modeling efforts for acoustic emission (AE) wave generation and propagation are discussed briefly along with their advantages and disadvantages. Continuous sensors placed at right angles on a plate are being discussed as a new approach to measure and locate the source of acoustic waves. Evolutionary novel signal processing algorithms and bio-inspired distributed sensor array systems are used on large structures and integrated aerospace vehicles for AE source localization and preliminary results are presented. These systems allow for a great reduction in the amount of data that needs to be processed and also reduce the chances of false alarms from ambient noises. It is envisioned that these biomimetic sensor arrays and signal processing techniques will be useful for both wireless and wired sensor arrays for real time health monitoring of large integrated aerospace vehicles and earth fixed civil structures. The sensor array architectures can also be used with other types of sensors and for other applications.

Ghoshal, Anindya↗

Combining Machine Learning and Numerical Simulation for High-Resolution PM2.5 Concentration Forecast

Forecasting ambient PM2.5 concentrations with spatiotemporal coverage is key to alerting decision-makers of pollution episodes and preventing detrimental public exposure, especially in regions with limited ground air monitoring stations. The existing methods either rely on chemical transport models (CTMs) to forecast spatial distribution of PM2.5 with nontrivial uncertainty or statistical algorithms to forecast PM2.5 concentration time-series at air monitoring locations without continuous spatial coverage. In this study, we developed a PM2.5 forecast framework by combining the robust Random Forest algorithm with a publicly accessible global CTM forecast product – NASA’s Goddard Earth Observing System “Composition Forecasting” (GEOS-CF), providing spatiotemporally continuous PM2.5 concentration forecasts for the next five days at a 1-km spatial resolution. Our forecast experiment was conducted for a region in Central China including the populous and polluted Fenwei Plain. The forecast for the next two days had overall validation R2 of 0.76 and 0.64, respectively; the R2 was around 0.5 for the following three forecast days. Spatial cross-validation showed similar validation metrics. Our forecast model, with validation normalized mean bias close to zero, substantially reduced the large biases in GEOS-CF. The proposed framework requires minimal computational resources compared to running CTMs at urban scales, enabling near-real-time PM2.5 forecast in resource-restricted environments.

PM2.5↗

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗

Flight test of takeoff performance monitoring system

The Takeoff Performance Monitoring System (TOPMS) is a computer software and hardware graphics system that visually displays current runway position, acceleration performance, engine status, and other situation advisory information to aid pilots in their decision to continue or to abort a takeoff. The system was developed at the Langley Research Center using the fixed-base Transport Systems Research Vehicle (TSRV) simulator. (The TSRV is a highly modified Boeing 737-100 research airplane.) Several versions of the TOPMS displays were evaluated on the TSRV B-737 simulator by more than 40 research, United States Air Force, airline and industry and pilots who rated the system satisfactory and recommended further development and testing. In this study, the TOPMS was flight tested on the TSRV. A total of 55 takeoff and 30 abort situations were investigated at 5 airfields. TOPMS displays were observed on the navigation display screen in the TSRV research flight deck during various nominal and off-nominal situations, including normal takeoffs; reduced-throttle takeoffs; induced-acceleration deficiencies; simulated-engine failures; and several gross-weight, runway-geometry, runway-surface, and ambient conditions. All tests were performed on dry runways. The TOPMS software executed accurately during the flight tests and the displays correctly depicted the various test conditions. Evaluation pilots found the displays easy to monitor and understand. The algorithm provides pretakeoff predictions of the nominal distances that are needed to accelerate the airplane to takeoff speed and to brake it to a stop; these predictions agreed reasonably well with corresponding values measured during several fully executed and aborted takeoffs. The TOPMS is operational and has been retained on the TSRV for general use and demonstration.

Middleton, David B.↗

Effects of Increased CO2 Level on the Well-Being, Growth and Renal Function of Rats

On the Space Shuttle the mean CO2 levels have been 0.3% which is ten times normal air, while there have been extended periods with mean levels of 0.7% and peak concentrations of 2%. On the Space Station the projected mean concentration of CO2 is 0.7% and not to exceed 1.0%. To ensure that high level of CO2 does not compromise the integrity of the science on the Space Station, the effects of chronic exposure to high levels of CO2 were investigated. Following 7 days of cage adaptation animals exposed to 2% CO2 for 30 days were compared to control (ambient air) animals and the effects on the well-being, growth and renal function analyzed. Ten male rats per group were placed in individual metabolic cages which allowed monitoring of daily food and water consumption, as well as feces and urine to be collected. Cages were placed in a plexiglass chamber with internal environment controlled by a computer in conjunction with gas sensors. The elevated CO2 was held constant at 2.0 +/- 0.03% and the O2 at 20.9 +/- 0.15%. Body weight and food and water intake were measured daily for the first ten days of exposure and then every three to four days for the remaining three weeks. Urine was measured for pH, CO2 (as an indicator for bicarbonate) and ammonia (as an indicator for ammonium). During 2% CO2 exposure, animal growth, weight, food and water consumption were within normal ranges suggesting that their well-being was not affected. Urine pH decreased from 7.12 to 6.77 over the first 6 days of exposure and increased the following 24 days returning to pre-exposure levels. Urine NH4+ increased 68% the first 6 days then dropped to and remained at 29% higher than pre-exposure level. Urine bicarbonate concentration did not change the first 6 days, but significantly increased by day 30. These results of chronic exposure to 2% C02 are consistent with renal compensation for respiratory acidosis which may impact science conducted on the Space Shuttle or the Space Station if CO2 levels reach 2%.

Lang, C.↗

Design And Testing of The Floating Potential Probe For ISS

Flight 4A was an especially critical mission for the International Space Station (ISS). For the first time, the high voltage solar arrays generated significant amounts of power and long predicted environmental interactions (high negative floating potential and concomitant dielectric charging) became serious concerns. Furthermore, the same flight saw the Plasma Contacting Unit (PCU) deployed and put into operation to mitigate and control these effects. The ISS program office has recognized the critical need to verify, by direct measurement, that ISS does not charge to unacceptable levels. A Floating Potential Probe (FPP) was therefore deployed on ISS to measure ISS floating potential relative to the surrounding plasma and to measure relevant plasma parameters. The primary objective of FPP is to verify that ISS floating potential does not exceed the specified level of 40 volts with respect to the ambient. Since it is expected that in normal operations the PCU will maintain ISS within this specification, it is equivalent to say that the objective of FPP is to monitor the functionality of the PCU. In this paper, we report on the design and testing of the ISS FPP. In a separate paper, the operations and results obtained so far by the FPP will be presented.

Hillard, G. Barry↗

SO2 over Central China: Measurements, Numerical Simulations and the Tropospheric Sulfur Budget

SO2 in central China was measured in situ from an aircraft and remotely using the Ozone Monitoring Instrument (OMI) from the Aura satellite; results were used to develop a numerical tool for evaluating the tropospheric sulfur budget - sources, sinks, transformation and transport. In April 2008, measured ambient SO2 concentrations decreased from approx.7 ppbv near the surface to approx. 1 ppbv at 1800 m altitude (an effective scale height of approx.800 m), but distinct SO2 plumes were observed between 1800 and 4500 m, the aircraft's ceiling. These free tropospheric plumes play a major role in the export of SO2 and in the accuracy of OMI retrievals. The mean SO2 column contents from aircraft measurements (0.73 DU, Dobson Units) and operational OMI SO2 products (0.63+/-0.26 DU) were close. The OMI retrievals were well correlated with in situ measurements (r = 0.84), but showed low bias (slope = 0.54). A new OMI retrieval algorithm was tested and showed improved agreement and bias (r = 0.87, slope = 0.86). The Community Multiscale Air Quality (CMAQ) model was used to simulate sulfur chemistry, exhibiting reasonable agreement (r = 0.62, slope = 1.33) with in situ SO2 columns. The mean CMAQ SO2 loading over central and eastern China was 54 kT, approx.30% more than the estimate from OMI SO2 products, 42 kT. These numerical simulations, constrained by observations, indicate that ",50% (35 to 61 %) of the anthropogenic sulfur emissions were transported downwind, and the overall lifetime of tropospheric SO2 was 38+/-7 h.

He, Hao↗

Sensor-Only System Identification for Structural Health Monitoring of Advanced Aircraft

Environmental conditions, cyclic loading, and aging contribute to structural wear and degradation, and thus potentially catastrophic events. The challenge of health monitoring technology is to determine incipient changes accurately and efficiently. This project addresses this challenge by developing health monitoring techniques that depend only on sensor measurements. Since actively controlled excitation is not needed, sensor-to-sensor identification (S2SID) provides an in-flight diagnostic tool that exploits ambient excitation to provide advance warning of significant changes. S2SID can subsequently be followed up by ground testing to localize and quantify structural changes. The conceptual foundation of S2SID is the notion of a pseudo-transfer function, where one sensor is viewed as the pseudo-input and another is viewed as the pseudo-output, is approach is less restrictive than transmissibility identification and operational modal analysis since no assumption is made about the locations of the sensors relative to the excitation.

Kukreja, Sunil L.↗

Report of the Ad Hoc Committee on the assessment of models of a wake shield environment around various spacecraft, Universities Space Research Association

Models depicting the ambient atmosphere which can overtake the spacecraft vacuum shield are presented. The subject areas discussed are: possible changing effects on the wake shield environment; possible utilization of the induced environmental contamination monitor; present state of the knowledge of the parameters used to describe the intermolecular collisions; the possibility of using simple models to describe the wake shield environment; possible errors associated with using kinetic theory to calculate that part of the atmosphere overtaking the shield; and a general assessment of the Monte Carlo techniques used to calculate the shield environment.

Wu, S. T.↗

In situ magnetic field observations of the AMPTE artificial comet

Magnetometers aboard the IRM and UKS spacecraft monitored the magnetic field during the AMPTE artificial comet experiment of Dec. 27, 1984. Rapid photoionization of the released barium vapor resulted in the formation of a magnetic cavity, shielded from the ambient magnetic field.The presence of this highly conductive obstacle caused draping and compression of the solar wind magnetic field.

Luehr, H.↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Endogenous thermoregulatory rhythms of squirrel monkeys in thermoneutrality and cold

Whole body heat production (HP) and heat loss (HL) were examined to determine if the free-running circadian rhythm in body temperature (Tb) results from coordinated changes in HP and HL rhythms in thermoneutrality (27 degrees C) as well as mild cold (17 degrees C). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of Tb and activity. Feeding was also measured. Rhythms of HP, HL, and conductance were tightly coupled with the circadian Tb rhythm at both ambient temperatures (TA). At 17 degrees C, increased HP compensated for higher HL at all phases of the Tb rhythm, resulting in only minor changes to Tb. Parallel compensatory changes of HP and HL were seen at all rhythm phases at both TA. Similar time courses of Tb, HP, and HL in their respective rhythms and the relative stability of Tb during both active and rest periods suggest action of the circadian timing system on Tb set point.

NASA Discipline Regulatory Physiology↗