Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Pando

SAND2025-02006O Pando is a distributed data analysis software tool. It is designed to handle large-scale graph analysis problems, often with a specific focus on blockchain/cryptocurrency data. Pando handles scalability by running on a distributed cluster of servers. Users can customize the output using the program’s plugin/extension design methodology. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Gabert, Kasimir↗

Target design optimization for an electron accelerator driven subcritical facility with circular and square beam profiles.

A subcritical facility driven by an electron accelerator is planned at the Kharkov Institute of Physics and Technology (KIPT) in Ukraine for medical isotope production, materials research, training, and education. The conceptual design of the facility is being pursued through collaborations between ANL and KIPT. As part of the design effort, the high-fidelity analyses of various target options are performed with formulations to reflect the realistic configuration and the three dimensional geometry of each design. This report summarizes the results of target design optimization studies for electron beams with two different beam profiles. The target design optimization is performed via the sequential neutronic, thermal-hydraulic, and structural analyses for a comprehensive assessment of each configuration. First, a target CAD model is developed with proper emphasis on manufacturability to provide a basis for separate but consistent models for subsequent neutronic, thermal-hydraulic, and structural analyses. The optimizations are pursued for maximizing the neutron yield, streamlining the flow field to avoid hotspots, and minimizing the thermal stresses to increase the durability. In addition to general geometric modifications, the inlet/outlet channel configurations, target plate partitioning schemes, flow manipulations and rates, electron beam diameter/width options, and cladding material choices are included in the design optimizations. The electron beam interactions with the target assembly and the neutronic response of the subcritical facility are evaluated using the MCNPX code. the results for the electron beam energy deposition, neutron generation, and utilization in the subcritical pile are then used to characterize the axisymmetric heat generation profiles in the target assembly with explicit simulations of the beam tube, the coolant, the clad, and the target materials. Both tungsten and uranium are considered as target materials. Neutron spectra from tungsten and uranium are very similar allowing the use of either material in the subcritical assembly without changing its characteristics. However, the uranium target has a higher neutron yield, which increases the neutron flux of the subcritical assembly. Based on the considered dimensions and heat generation profiles, the commercial CFD software Star-CD is used for the thermal-hydraulic analysis of each target design to satisfy a set of thermal criteria, the most limiting of which being to maintain the water temperature 50 below the boiling point. It is found that the turbulence in the inlet channels dissipates quickly in narrow gaps between the target plates and, as a result, the heat transfer is limited by the laminar flow conditions. On average, 3-D CFD analyses of target assemblies agree well with 1-D calculations using RELAP (performed by KIPT). However, the recirculation and stagnation zones predicted with the CFD models prove the importance of a 3-D analysis to avoid the resulting hotspots. The calculated temperatures are subsequently used for the structural analysis of each target configuration to satisfy the other engineering design requirements. The thermo-structural calculations are performed mostly with NASTRAN and the results occasionally compared with the results from MARC. Both, NASTRAN and MARC are commercially available structural-mechanics analysis software. Although, a significant thermal gradient forms in target elements along the beam direction, the high thermal stresses are generally observed peripherally around the edge of thin target disks/plates. Due to its high thermal conductivity, temperatures and thermal stresses in tungsten target are estimated to be significantly lower than in uranium target. The deformations of the target disks/plates are found to be insignificant, which eliminate concerns for flow blockages in narrow coolant channels. Consistent with the specifications of the KIPT accelerator to be used in this facility, the electron beam power is 100-kW with electron energy in the range of 100 to 200 MeV. As expected, the 100 MeV electrons deposit their energy faster while the 200-MeV electrons spread their energy deposition further along the beam direction. However in that electron energy range, the energy deposition profiles near the beam window require very thin target plates/disks to limit the temperatures and thermal stresses.

43 PARTICLE ACCELERATORS↗

n-dimensional Statistical Inverse Graphical Hydraulic Test Simulator

nSIGHTS (n-dimensional Statistical Inverse Graphical Hydraulic Test Simulator) is a comprehensive well test analysis software package. It provides a user-interface, a well test analysis model and many tools to analyze both field and simulated data. The well test analysis model simulates a single-phase, one-dimensional, radial/non-radial flow regime, with a borehole at the center of the modeled flow system. nSIGHTS solves the radially symmetric n-dimensional forward flow problem using a solver based on a graph-theoretic approach. The results of the forward simulation are pressure, and flow rate, given all the input parameters. The parameter estimation portion of nSIGHTS uses a perturbation-based approach to interpret the best-fit well and reservoir parameters, given an observed dataset of pressure and flow rate.

Source record↗

What's New in GSAS-II

The General Structure and Analysis Software II (GSAS-II) package is an all-new crystallographic analysis package written to replace and extend the capabilities of the universal and widely used GSAS and EXPGUI packages. GSAS-II was described in a 2013 article, but considerable work has been completed since then. This paper describes the advances, which include: rigid body fitting and structure solution modules; improved treatment for parametric refinements and equation of state fitting; and small-angle scattering data reduction and analysis. GSAS-II offers versatile and extensible modules for import and export of data and results. Capabilities are provided for users to select any version of the code. Code documentation has reached 150 pages and 17 web-tutorials are offered. © 2014 International Centre for Diffraction Data.

Toby, Brian H.↗

NECP-Cypress: Development and Benchmarking of a 3D PWR Core-Analysis Code

As one of the key components of nuclear reactor design and safety analysis software for Pressurized Water Reactor (PWR), the advance of the core-analysis code indicates the nuclear power development of the corresponding country. Hence, Nuclear Engineering Computational Physics Lab. (NECP) developed a PWR core-analysis code NECP-Cypress. Currently, it contains several modules including a generalized cross section module, a diffusion module using the Variational Nodal Method (VNM), a depletion-calculation using the traditional macroscopic module, a thermal-hydraulics module solving the single channel heat transfer equation and 1D heat conduction equation. With the VNM employed, NECP-Cypress can eliminate the control rod cusping effect and provide a better pin power reconstruction. In this paper, we firstly introduce the modules of the code NECP-Cypress. Secondly, two large-scale PWR core benchmarks were employed to demonstrate the ability of the code by comparing with SIMULATE-3, including the BEAVRS problem and a pseudo CAP1400 reactor core problem. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation

Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX) is severely limited by the scarcity of X-ray free-electron laser (XFEL) sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX). As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS), are reported. Microcrystals (5–20 µm) of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A 2A adenosine receptor (A 2A AR), the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP) or a high-molecular-weight poly(ethylene oxide) (PEO; molecular weight 8 000 000) were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding) software developed at APS as well as the SFX data-reduction and analysis software suites Cheetah and CrystFEL enabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A 2A AR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A 2A AR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5–20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the planned APS-U upgrade will increase the intensity by two orders of magnitude. Furthermore, these developments will enable structure determination from smaller and/or weakly diffracting microcrystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Python Instrument Control and Data Acquisition Suite for Reproducible Research

Tools that standardize and automate experimental data collection are needed for greater confidence in research results. The National Synchrotron Light Source-II (NSLS-II) has generated an open-source Python data acquisition, management, and analysis software suite that automates X-ray experiments and collects an experimental record that facilitates complete reproducibility. Here, we show that the NSLS-II tools are not only useful for X-ray science at large-scale facilities by presenting an add-on package that adapts these tools for use in a small laboratory with common physics and electrical engineering instruments. The composite software suite eases and automates the execution of experiments, records extensive metadata, stores data in portable containers, and speeds up the analysis through tools for comprehensive searches. In total, this software suite increases the reproducibility of laboratory experiments. We demonstrate the software via the evaluation of two lock-in amplifiers-the miniature ADA2200 and the ubiquitous Stanford Research Systems (SRS) SR810. The frequency resolution, signal-to-noise ratio, and dynamic reserve of the lock-in amplifiers are measured and presented. The usage of the software suite is described throughout these measurements so that the reader can implement the tools in their lab.

97 MATHEMATICS AND COMPUTING↗

Memorandum of Understanding for the 2010 Meson Test Beam Program T-995: Muon Detector / Tail Catcher R&D

This is a memorandum of understanding between the Fermi National Accelerator Laboratory and experimenters from Fermilab, Indiana University, Northern Illinois University, University of Notre Dame, Wayne State University, INFN (Trieste / Udine, Roma I, Padova, Ferrara) who have committed to participate in beam tests to be carried out during the 2010 MTBF pro gram. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties. However, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate amendments to this memorandum which will reflect such required adjustments. The test objectives are to continue the development of extruded scintillator-based muon counters begun in T-956 with emphasis on the use of Si Pixelated Photon Detectors (PPDs). The R&D program outlined here continues the T-956 studies using particle beams to test long strip counters, up to 6m, and new prototype TB4 electronics developed at Fermilab which the experimenters expect will lead to the assembly of future large-scale integrated systems that may be the subject for a future proposal. For the purpose of this work, T-995 will require limited space and resources which may be compatible with other users' equipment in the testing area. The T-995 experimenters may not always require control of the beam. The T-995 experimenters will use some of the same apparatus that is to be used by the experimenters who will study total absorption dual readout calorimetry at MTest (experiment T-1004). The T-995 and T-I004 experimenters both use newly designed Fermilab electronics to digitize the shape of the PPD pulse corresponding to the scintillator output. Both projects will share most of the data acquisition software and typically they will share the same beam instrumentation (beam defining counters and coincidence circuits). Both sets of experimenters will share some of the same counting house logic and analysis software for on-line data analysis. Some of the T-995 and T-I004 manpower available to the two projects will work on both projects although many of the studies will not run concurrently.

43 PARTICLE ACCELERATORS↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Virtual tool mark generation for efficient striation analysis in forensic science

In 2009, a National Academy of Sciences report called for investigation into the scienti c basis behind tool mark comparisons (National Academy of Sciences, 2009). Answering this call, Chumbley et al. (2010) attempted to prove or disprove the hypothesis that tool marks are unique to a single tool. They developed a statistical algorithm that could, in most cases, discern matching and non-matching tool marks made at di erent angles by sequentially numbered screwdriver tips. Moreover, in the cases where the algorithm misinterpreted a pair of marks, an experienced forensics examiner could discern the correct outcome. While this research served to con rm the basic assumptions behind tool mark analysis, it also suggested that statistical analysis software could help to reduce the examiner's workload. This led to a new tool mark analysis approach, introduced in this thesis, that relies on 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. These scans are carefully cleaned to remove noise from the data acquisition process and assigned a coordinate system that mathematically de nes angles and twists in a natural way. The marking process is then simulated by using a 3D graphics software package to impart rotations to the tip and take the projection of the tip's geometry in the direction of tool travel. The edge of this projection, retrieved from the 3D graphics software, becomes a virtual tool mark. Using this method, virtual marks are made at increments of 5 and compared to a scan of the evidence mark. The previously developed statistical package from Chumbley et al. (2010) performs the comparison, comparing the similarity of the geometry of both marks to the similarity that would occur due to random chance. The resulting statistical measure of the likelihood of the match informs the examiner of the angle of the best matching virtual mark, allowing the examiner to focus his/her mark analysis on a smaller range of angles. Preliminary results are quite promising. In a study with both sides of 6 screwdriver tips and 34 corresponding marks, the method distinguished known matches from known non-matches with zero false positive matches and only two matches mistaken for non-matches. For matches, it could predict the correct marking angle within 5-10 . Moreover, on a standard desktop computer, the virtual marking software is capable of cleaning 3D tip and plate scans in minutes and producing a virtual mark and comparing it to a real mark in seconds. These results support several of the professional conclusions of the tool mark analysis com- munity, including the idea that marks produced by the same tool only match if they are made at similar angles. The method also displays the potential to automate part of the comparison process, freeing the examiner to focus on other tasks, which is important in busy, backlogged crime labs. Finally, the method o ers the unique chance to directly link an evidence mark to the tool that produced it while reducing potential damage to the evidence.

42 ENGINEERING↗

Multimodal X-ray nano-spectromicroscopy analysis of chemically heterogeneous systems

Abstract Understanding the nanoscale chemical speciation of heterogeneous systems in their native environment is critical for several disciplines such as life and environmental sciences, biogeochemistry, and materials science. Synchrotron-based X-ray spectromicroscopy tools are widely used to understand the chemistry and morphology of complex material systems owing to their high penetration depth and sensitivity. The multidimensional (4D+) structure of spectromicroscopy data poses visualization and data-reduction challenges. This paper reports the strategies for the visualization and analysis of spectromicroscopy data. We created a new graphical user interface and data analysis platform named XMIDAS (X-ray multimodal image data analysis software) to visualize spectromicroscopy data from both image and spectrum representations. The interactive data analysis toolkit combined conventional analysis methods with well-established machine learning classification algorithms (e.g. nonnegative matrix factorization) for data reduction. The data visualization and analysis methodologies were then defined and optimized using a model particle aggregate with known chemical composition. Nanoprobe-based X-ray fluorescence (nano-XRF) and X-ray absorption near edge structure (nano-XANES) spectromicroscopy techniques were used to probe elemental and chemical state information of the aggregate sample. We illustrated the complete chemical speciation methodology of the model particle by using XMIDAS. Next, we demonstrated the application of this approach in detecting and characterizing nanoparticles associated with alveolar macrophages. Our multimodal approach combining nano-XRF, nano-XANES, and differential phase-contrast imaging efficiently visualizes the chemistry of localized nanostructure with the morphology. We believe that the optimized data-reduction strategies and tool development will facilitate the analysis of complex biological and environmental samples using X-ray spectromicroscopy techniques.

36 MATERIALS SCIENCE↗

Scoreboard

Emerging HPC machines have given rise to enhanced compute power that far outstrips the machine's ability to save large scale results for post-processing. To combat this, in situ data analysis techniques are slowly being adopted. With in situ data management favoring workflows composed of multiple simulations and analyses connected in transit on heterogeneous machines, scientists and engineers need a tool that enables them to create data extracts, visualizations, and interactively monitor and steer their simulations. Scoreboard Phase II is a next generation analysis software that supports composite in transit workflows on heterogeneous architectures and restores interactivity to in situ data analysis through simulation monitoring and computational steering. Scoreboard provides a simulation dashboard with graphs of metrics over time, controls for setting custom simulation steering parameters, controls for managing the set of data extracts being produced in the simulation, as well as the ability to explore data extracts, all from a web browser. Realizing the vision outlined in this project required research into making a system that integrates end to end from simulations all the way to the user. In situ tools generally suffer from complexity and excessive software dependencies. Scoreboard, by contrast, is easy to build and integrate into simulation codes and it provides first class FORTRAN support. The Scoreboard library is capable of in situ and in transit data analysis that can produce data extracts commonly needed for Computational Fluid Dynamics (CFD) analysis. Simulations can transparently stage data in transit to a Scoreboard Endpoint program, which can accept their data and produce the requested data extracts. This lets simulations return to their work while the Endpoint works on the analysis. Efficiently staging the data at scale was a topic of this research. Scoreboard provides the means to let the user manage data extracts and monitor/steer many simulations from a web browser. This area of the research focused on discovery of in transit network components to expose and control their steering parameters within an interactive browser-based user interface that includes: system topology, gathered metrics, notifications, dynamically-generated steering controls, and exploration of visualization data products.

Whitlock, BradJoseph [Intelligent Light] (00000001↗

Visual analysis of code security

To help increase the confidence that software is secure, researchers and vendors have developed different kinds of automated software security analysis tools. These tools analyze software for weaknesses and vulnerabilities, but the individual tools catch different vulnerabilities and produce voluminous data with many false positives. This paper describes a system that brings together the results of disparate software analysis tools into a visual environment to support the triage and exploration of code vulnerabilities. Our system allows software developers to explore vulnerability results to uncover hidden trends, triage the most important code weaknesses, and show who is responsible for introducing software vulnerabilities. By correlating and normalizing multiple software analysis tools' data, the overall vulnerability detection coverage of software is increased. A visual overview and powerful interaction allows the user to focus attention on the most pressing vulnerabilities within huge volumes of data, and streamlines the secure software development workflow through integration with development tools.

99 GENERAL AND MISCELLANEOUS↗

Monte Carlo Simulation Tool Installation and Operation Guide

This document provides information on software and procedures for Monte Carlo simulations based on the Geant4 toolkit, the ROOT data analysis software and the CRY cosmic ray library. These tools have been chosen for its application to shield design and activation studies as part of the simulation task for the Majorana Collaboration. This document includes instructions for installation, operation and modification of the simulation code in a high cyber-security computing environment, such as the Pacific Northwest National Laboratory network. It is intended as a living document, and will be periodically updated. It is a starting point for information collection by an experimenter, and is not the definitive source. Users should consult with one of the authors for guidance on how to find the most current information for their needs.

CRY↗

IBIXFIT: A Tool For The Analysis Of Microcalorimeter PIXE Spectra

PIXE analysis software has been for long mainly tuned to the needs of Si(Li) detector based spectra analysis and quantification methods based on K{sub {alpha}} or L{sub {alpha}} X-ray lines. Still, recent evidences related to the study of relative line intensities and new developments in detection equipment, namely the emergence of commercial microcalorimeter based X-ray detectors, have brought up the possibility that in the near future PIXE will become more than just major lines quantification. A main issue that became evident as a consequence of this was the need to be able to fit PIXE spectra without prior knowledge of relative line intensities. Considering new developments it may be necessary to generalize PIXE to a wider notion of ion beam induced X-ray (IBIX) emission, to include the quantification of processes such as Radiative Auger Emission. In order to answer to this need, the IBIXFIT code was created based much on the Bayesian Inference and Simulated Annealing routines implemented in the Datafurnace code [1]. In this presentation, the IBIXFIT is used to fit a microcalorimeter spectrum of a Ba{sub x}Sr{sub (1-x)}TiO{sub 3} thin film sample and the specific possibility of selecting between fixed and free line ratios combined with other specificities of the IBIXFIT algorithm are shown to be essential to overcome the problems faced.

74 ATOMIC AND MOLECULAR PHYSICS↗

Combining Genome-Scale Experimental and Computational Methods To Identify Essential Genes in Rhodobacter sphaeroides

Knowledge about the role of genes under a particular growth condition is required for a holistic understanding of a bacterial cell and has implications for health, agriculture, and biotechnology. We developed the Tn-seq analysis software (TSAS) package to provide a flexible and statistically rigorous workflow for the high-throughput analysis of insertion mutant libraries, advanced the knowledge of gene essentiality in R. sphaeroides , and illustrated how Tn-seq data can be used to more accurately identify genes that play important roles in metabolism and other processes that are essential for cellular survival.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis Description Languages for the LHC

An analysis description language is a domain specific language capable of describing the contents of an LHC analysis in a standard and unambiguous way, independent of any computing framework. It is designed for use by anyone with an interest in, and knowledge of, LHC physics, i.e., experimentalists, phenomenologists and other enthusiasts. Adopting analysis description languages would bring numerous benefits for the LHC experimental and phenomenological communities ranging from analysis preservation beyond the lifetimes of experiments or analysis software to facilitating the abstraction, design, visualization, validation, combination, reproduction, interpretation and overall communication of the analysis contents. Here, we introduce the analysis description language concept and summarize the current efforts ongoing to develop such languages and tools to use them in LHC analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New surface characterization tools for alumina based refractory material exposed to cavitation - Image analysis and pattern recognition approach

Highlights: • Surface degradation was monitored via mass loss measurement. • Observation of surface damage destruction was done using image analysis. • Shape parameters of surface defects change during cavitation. • Shape parameters changes are correlated to mass loss measurements. - Abstract: The aim of this study was to examine the influence of cavitation erosion on the morphology of defects formed on the surfaces of alumina-based materials. The alumina-based samples were exposed to cavitation erosion for 42 min. The damages that occurred were monitored at predefined time intervals by measuring the mass loss and observing the sample surfaces. Digital images of surfaces were processed using an image analysis software package to define morphological characteristics of the damages occurred. The calculated morphological parameters were subjected to analysis by pattern recognition techniques to correlate the appearance of particular morphological characteristics with the behavior of the material during cavitation erosion. The newly established method in describing cavitation erosion which uses pattern recognition approach for treatments of morphological parameters calculated for damages by image analysis tools gave the results efficient for material characterization as the traditional one.

36 MATERIALS SCIENCE↗