Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automatic Labeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Automatically Finding Ship-Tracks to Enable Large-Scale Analysis of Aerosol-Cloud Interactions

Ship tracks appear as long winding linear features in satellite images and are produced by aerosols from ship exhausts changing low cloud properties. They are one of the best examples of aerosol‐cloud interaction experiments. However, manually finding ship tracks from satellite data on a large scale is prohibitively costly while a large number of samples are required to improve our understanding. Here we train a deep neural network to automate finding ship tracks. The neural network model generalizes well as it not only finds ship tracks labeled by human experts but also detects those that are occasionally missed by humans. It finds more ship tracks than all previous studies combined and produces a map of ship track distributions off the California coast that matches well with known shipping traffic. Our technique will enable studying aerosol effects on low clouds using ship tracks on a large scale, which will potentially narrow the uncertainty of the aerosol‐cloud interactions.

aerosol cloud interactions↗

Algorithms for Automatic Alignment of Arrays

Aggregate data objects (such as arrays) are distributed across the processor memories when compiling a data-parallel language for a distributed-memory machine. The mapping determines the amount of communication needed to bring operands of parallel operations into alignment with each other. A common approach is to break the mapping into two stages: an alignment that maps all the objects to an abstract template, followed by a distribution that maps the template to the processors. This paper describes algorithms for solving the various facets of the alignment problem: axis and stride alignment, static and mobile offset alignment, and replication labeling. We show that optimal axis and stride alignment is NP-complete for general program graphs, and give a heuristic method that can explore the space of possible solutions in a number of ways. We show that some of these strategies can give better solutions than a simple greedy approach proposed earlier. We also show how local graph contractions can reduce the size of the problem significantly without changing the best solution. This allows more complex and effective heuristics to be used. We show how to model the static offset alignment problem using linear programming, and we show that loop-dependent mobile offset alignment is sometimes necessary for optimum performance. We describe an algorithm with for determining mobile alignments for objects within do loops. We also identify situations in which replicated alignment is either required by the program itself or can be used to improve performance. We describe an algorithm based on network flow that replicates objects so as to minimize the total amount of broadcast communication in replication.

Chatterjee, Siddhartha↗

SU-F-R-25: Automatic Identification of Suspicious Recurrent/residual Disease Regions After Prostatectomy

Purpose: To automatically identify and outline suspicious regions of recurrent or residual disease in the prostate bed using Dynamic Contrast Enhanced-MRI (DCE-MRI) in patients after prostatectomy. Methods: Twenty-two patients presenting for salvage radiotherapy and with identified Gross Tumor Volume (GTV) in the prostate bed were retrospectively analyzed. The MRI data consisted of Axial T2weighted-MRI (T2w) of the pelvis: resolution 1.25×1.25×2.5 mm; Field of View (FOV): 320×320 mm; slice thickness=2.5mm; 72 slices; and Dynamic Contrast Enhanced MRI (DCE-MRI)–12 series of T1w with identical spatial resolution to T2w and at 30–34s temporal resolution. Unsupervised pattern recognition was used to decompose the 4D DCE data as the product W.H of weights W of k patterns H. A well-perfused pattern Hwp was identified and the weight map Wwp associated to Hwp was used to delineate suspicious volumes. Threshold of Wwp set at mean(Wwp)+S*std(Wwp), S=1,1.5,2 and 2.5 defined four volumes labeled as DCE1.0 to DCE2.5. These volumes were displayed on T2w and, along with GTV, were correlated with the highest pre-treatment PSA values, and with pharmacokinetic analysis constants. Results: GTV was significantly correlated with DCE2.0(ρ= 0.60, p<0.003), and DCE 2.5 (ρ=0.58, p=0.004)). Significant correlation was found between highest pre-treatment PSA and GTV(ρ=0.42, p<0.049), DCE2.0(ρ= 0.52, p<0.012), and DCE 2.5 (ρ=0.67, p<<0.01)). Kruskal-Wallis analysis showed that Ktrans median value was statistically different between non-specific prostate bed tissue NSPBT and both GTV (p<<0.001) and DCE2.5 (p<<0.001), but while median Ve was statistically different between DCE2.5 and NSPBT (p=0.002), it was not statistically different between GTV and NSPBT (p=0.054), suggesting that automatic volumes capture more accurately the area of malignancy. Conclusion: Software developed for identification and visualization of suspicions regions in DCE-MRI from post-prostatectomy patients has been validated by PSA and pharmacokinetic constants analysis showing that it generates clinically relevant volumes.

60 APPLIED LIFE SCIENCES↗

Automated bone segmentation from dental CBCT images using patch-based sparse representation and convex optimization

Purpose: Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the poor image quality, including very low signal-to-noise ratio and the widespread image artifacts such as noise, beam hardening, and inhomogeneity, it is challenging to segment the CBCT images. In this paper, the authors present a new automatic segmentation method to address these problems. Methods: To segment CBCT images, the authors propose a new method for fully automated CBCT segmentation by using patch-based sparse representation to (1) segment bony structures from the soft tissues and (2) further separate the mandible from the maxilla. Specifically, a region-specific registration strategy is first proposed to warp all the atlases to the current testing subject and then a sparse-based label propagation strategy is employed to estimate a patient-specific atlas from all aligned atlases. Finally, the patient-specific atlas is integrated into amaximum a posteriori probability-based convex segmentation framework for accurate segmentation. Results: The proposed method has been evaluated on a dataset with 15 CBCT images. The effectiveness of the proposed region-specific registration strategy and patient-specific atlas has been validated by comparing with the traditional registration strategy and population-based atlas. The experimental results show that the proposed method achieves the best segmentation accuracy by comparison with other state-of-the-art segmentation methods. Conclusions: The authors have proposed a new CBCT segmentation method by using patch-based sparse representation and convex optimization, which can achieve considerably accurate segmentation results in CBCT segmentation based on 15 patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect detection in atomic-resolution images via unsupervised learning with translational invariance

Abstract Crystallographic defects can now be routinely imaged at atomic resolution with aberration-corrected scanning transmission electron microscopy (STEM) at high speed, with the potential for vast volumes of data to be acquired in relatively short times or through autonomous experiments that can continue over very long periods. Automatic detection and classification of defects in the STEM images are needed in order to handle the data in an efficient way. However, like many other tasks related to object detection and identification in artificial intelligence, it is challenging to detect and identify defects from STEM images. Furthermore, it is difficult to deal with crystal structures that have many atoms and low symmetries. Previous methods used for defect detection and classification were based on supervised learning, which requires human-labeled data. In this work, we develop an approach for defect detection with unsupervised machine learning based on a one-class support vector machine (OCSVM). We introduce two schemes of image segmentation and data preprocessing, both of which involve taking the Patterson function of each segment as inputs. We demonstrate that this method can be applied to various defects, such as point and line defects in 2D materials and twin boundaries in 3D nanocrystals.

36 MATERIALS SCIENCE↗

Automated extraction of knowledge for model-based diagnostics

The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.

Gonzalez, Avelino J.↗

Telemetry-Enhancing Scripts

Scripts Providing a Cool Kit of Telemetry Enhancing Tools (SPACKLE) is a set of software tools that fill gaps in capabilities of other software used in processing downlinked data in the Mars Exploration Rovers (MER) flight and test-bed operations. SPACKLE tools have helped to accelerate the automatic processing and interpretation of MER mission data, enabling non-experts to understand and/or use MER query and data product command simulation software tools more effectively. SPACKLE has greatly accelerated some operations and provides new capabilities. The tools of SPACKLE are written, variously, in Perl or the C or C++ language. They perform a variety of search and shortcut functions that include the following: Generating text-only, Event Report-annotated, and Web-enhanced views of command sequences; Labeling integer enumerations with their symbolic meanings in text messages and engineering channels; Systematic detecting of corruption within data products; Generating text-only displays of data-product catalogs including downlink status; Validating and labeling of commands related to data products; Performing of convenient searches of detailed engineering data spanning multiple Martian solar days; Generating tables of initial conditions pertaining to engineering, health, and accountability data; Simplified construction and simulation of command sequences; and Fast time format conversions and sorting.

Maimone, Mark W.↗

Multi-Mission Terrain Classifier for Safe Rover Navigation and Automated Science

We previously presented Soil Property and Object Classification (SPOC), a machine learning-based terrain classifier for Mars rovers, for automatically segmenting rover images by its surface type such as sand and bedrock. This paper presents a number of practical improvements to pave the way for potential future onboard deployment. First, we achieved 97.0% overall pixel accuracy, evaluated against the classification generated by human experts on images from Mars Science Laboratory (MSL) missions. The substantial increase in accuracy was primarily enabled by the sheer volume of data used for training; we created a new large-scale dataset of Martian terrain labels, namely AI4Mars, which contains more than 400k labels contributed by citizen scientists for 50k images taken by the Mars Exploration Rovers (MER) and Mars Science Laboratory (MSL) rover. Second, we demonstrated that SPOC can quickly adapt to a new mission landed on a previously unseen site. Specifically, we pretrained a model with MER and MSL data from the AI4Mars dataset and then adapted to the Mars 2020 Rover (M2020) by feeding a small volume of data between Sol 0 and 157; the adapted model was tested on Sol 200-203 and resulted in 84.2% overall pixel accuracy and 93.4% reliability (recall) for detecting sand, the most concerning class for rover’s traversability. Third, we found that pretraining can substantially mitigate the decline of accuracy over time. We showed that the performance of a SPOC model pretrained with the ImageNet dataset and then trained by MSL images only up to Sol 390 remains comparable to a model trained by images up to Sol 1689 on the test data after Sol 1689. Fourth, we reimplemented SPOC with a light-weight convolutional neural network (CNN), MobileNetV2, which typically runs within tens of milliseconds (ms) on mobile processors such as Qualcomm’s Snapdragon. Finally, we released the AI4Mars dataset to the public to encourage open innovation.

Ono, Masahiro↗

Characterizing the DNA damage response by cell tracking algorithms and cell features classification using high-content time-lapse analysis

Traditionally, the kinetics of DNA repair have been estimated using immunocytochemistry by labeling proteins involved in the DNA damage response (DDR) with fluorescent markers in a fixed cell assay. However, detailed knowledge of DDR dynamics across multiple cell generations cannot be obtained using a limited number of fixed cell time-points. Here we report on the dynamics of 53BP1 radiation induced foci (RIF) across multiple cell generations using live cell imaging of non-malignant human mammary epithelial cells (MCF10A) expressing histone H2B-GFP and the DNA repair protein 53BP1-mCherry. Using automatic extraction of RIF imaging features and linear programming techniques, we were able to characterize detailed RIF kinetics for 24 hours before and 24 hours after exposure to low and high doses of ionizing radiation. High-content-analysis at the single cell level over hundreds of cells allows us to quantify precisely the dose dependence of 53BP1 protein production, RIF nuclear localization and RIF movement after exposure to X-ray. Using elastic registration techniques based on the nuclear pattern of individual cells, we could describe the motion of individual RIF precisely within the nucleus. We show that DNA repair occurs in a limited number of large domains, within which multiple small RIFs form, merge and/or resolve with random motion following normal diffusion law. Large foci formation is shown to be mainly happening through the merging of smaller RIF rather than through growth of an individual focus. We estimate repair domain sizes of 7.5 to 11 µm 2 with a maximum number of ~15 domains per MCF10A cell. This work also highlights DDR which are specific to doses larger than 1 Gy such as rapid 53BP1 protein increase in the nucleus and foci diffusion rates that are significantly faster than for spontaneous foci movement. We hypothesize that RIF merging reflects a "stressed" DNA repair process that has been taken outside physiological conditions when too many DSB occur at once. High doses of ionizing radiation lead to RIF merging into repair domains which in turn increases DSB proximity and misrepair. Furthermore, such finding may therefore be critical to explain the supralinear dose dependence for chromosomal rearrangement and cell death measured after exposure to ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Aftershock Identification Using a Paired Neural Network Applied to Constructed Data

This report is intended to detail the findings of our investigation of the applicability of machine learning to the task of aftershock identification. The ability to automatically identify nuisance aftershock events to reduce analyst workload when searching for events of interest is an important step in improving nuclear monitoring capabilities and while waveform cross - correlation methods have proven successful, they have limitations (e.g., difficulties with spike artifacts, multiple aftershocks in the same window) that machine learning may be able to overcome. Here we apply a Paired Neural Network (PNN) to a dataset consisting of real, high quality signals added to real seismic noises in order to work with controlled, labeled data and establish a baseline of the PNN's capability to identify aftershocks. We compare to waveform cross - correlation and find that the PNN performs well, outperforming waveform cross - correlation when classifying similar waveform pairs, i.e., aftershocks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using active learning to improve quasar identification for the DESI spectra processing pipeline

The Dark Energy Spectroscopic Instrument (DESI) survey uses an automatic spectral classification pipeline to classify spectra. QuasarNET is a convolutional neural network used as part of this pipeline originally trained using data from the Baryon Oscillation Spectroscopic Survey (BOSS). In this paper we implement an active learning algorithm to optimally select spectra to use for training a new version of the QuasarNET weights file using only DESI data, with the goal of improving classification accuracy. This active learning algorithm includes a novel outlier rejection step using a Self-Organizing Map to ensure we label spectra representative of the larger quasar sample observed in DESI. We perform two iterations of the active learning pipeline, assembling a final dataset of 5600 labeled spectra, a small subset of the approximately 1.3 million quasar targets in DESI's Data Release 1. When splitting the spectra into training and validation subsets we achieve similar performance to the previously trained weights file in completeness and purity calculated on the validation dataset but do so with less than one tenth of the amount of training data. The new weights also more consistently classify objects in the same way when used on unlabeled data compared to the old weights file. In the process of improving QuasarNET's classification accuracy we discovered a systemic error in QuasarNET's redshift estimation and used our findings to improve our understanding of QuasarNET's redshifts.

Machine learning↗

Advanced Signal Processing Methods Applied to Digital Mammography

The work reported here is on the extension of the earlier proposal of the same title, August 1994-June 1996. The report for that work is also being submitted. The work reported there forms the foundation for this work from January 1997 to September 1997. After the earlier work was completed there were a few items that needed to be completed prior to submission of a new and more comprehensive proposal for further research. Those tasks have been completed and two new proposals have been submitted, one to NASA, and one to Health & Human Services WS). The main purpose of this extension was to refine some of the techniques that lead to automatic large scale evaluation of full mammograms. Progress on each of the proposed tasks follows. Task 1: A multiresolution segmentation of background from breast has been developed and tested. The method is based on the different noise characteristics of the two different fields. The breast field has more power in the lower octaves and the off-breast field behaves similar to a wideband process, where more power is in the high frequency octaves. After the two fields are separated by lowpass filtering, a region labeling routine is used to find the largest contiguous region, the breast. Task 2: A wavelet expansion that can decompose the image without zero padding has been developed. The method preserves all properties of the power-of-two wavelet transform and does not add appreciably to computation time or storage. This work is essential for analysis of the full mammogram, as opposed to selecting sections from the full mammogram. Task 3: A clustering method has been developed based on a simple counting mechanism. No ROC analysis has been performed (and was not proposed), so we cannot finally evaluate this work without further support. Task 4: Further testing of the filter reveals that different wavelet bases do yield slightly different qualitative results. We cannot provide quantitative conclusions about this for all possible bases without further support. Task 5: Better modeling does indeed make an improvement in the detection output. After the proposal ended, we came up with some new theoretical explanations that helps in understanding when the D4 filter should be better. This work is currently in the review process. Task 6: N/A. This no longer applies in view of Tasks 4-5. Task 7: Comprehensive plans for further work have been completed. These plans are the subject of two proposals, one to NASA and one to HHS. These proposals represent plans for a complete evaluation of the methods for identifying normal mammograms, augmented with significant further theoretical work.

Stauduhar, Richard P.↗

CLUSTERING-BASED FEATURE LEARNING ON VARIABLE STARS

The success of automatic classification of variable stars depends strongly on the lightcurve representation. Usually, lightcurves are represented as a vector of many descriptors designed by astronomers called features. These descriptors are expensive in terms of computing, require substantial research effort to develop, and do not guarantee a good classification. Today, lightcurve representation is not entirely automatic; algorithms must be designed and manually tuned up for every survey. The amounts of data that will be generated in the future mean astronomers must develop scalable and automated analysis pipelines. In this work we present a feature learning algorithm designed for variable objects. Our method works by extracting a large number of lightcurve subsequences from a given set, which are then clustered to find common local patterns in the time series. Representatives of these common patterns are then used to transform lightcurves of a labeled set into a new representation that can be used to train a classifier. The proposed algorithm learns the features from both labeled and unlabeled lightcurves, overcoming the bias using only labeled data. We test our method on data sets from the Massive Compact Halo Object survey and the Optical Gravitational Lensing Experiment; the results show that our classification performance is as good as and in some cases better than the performance achieved using traditional statistical features, while the computational cost is significantly lower. With these promising results, we believe that our method constitutes a significant step toward the automation of the lightcurve classification pipeline.

79 ASTRONOMY AND ASTROPHYSICS↗

Anatomy of the Vestibulo-automatic Outflow to the Gut

Motion sickness can be induced by vestibular effects on the sympathetic portion of the autonomic nervous system. However, the pathways linking the vestibular and autonomic pathways are unknown. As a first step in this analysis, the locations of preganglionic sympathetic neurons (PSN) and dorsal root afferent ganglionic neurons (DRG) which supply sympathetic innervation to major portions of the gastrointestinal tract in rabbits were identified. The objective of a second series of experiments is to determine which of the brainstem nuclei project to the autonomic regions of the spinal cord that control gastrointestinal motility. To achieve this goal, a trans-synaptic retrograde tracer (3H-tetanus toxoid) is applied to the greater splanchnic nerve. This method allows the labeling of neurons within the brainstem that project only to the preganglionic synpathetic neurons. One structure that has been strongly implicated in mediating vestibulo-autonomic control is the cerebellum (i.e., nodulus and uvula). The outflow of these lobules to the autonomic regions of the brainstem is mediated by the fastigial nucleus. To determine the precise projections of the fastigial nucleus to the brainstem nuclei involved in emesis, anterograde tracer (3H-leucine) was injected into the fastigial nucleus in a third series of experiments.

Torigoe, Y.↗

Single-cell correlations of mRNA and protein content in a human monocytic cell line after LPS stimulation

The heterogeneity of mRNA and protein expression at the single-cell level can reveal fundamental information about cellular response to external stimuli, including the sensitivity, timing, and regulatory interactions of genes. Here we describe a fully automated system to digitally count the intron, mRNA, and protein content of up to five genes of interest simultaneously in single-cells. Full system automation of 3D microscope scans and custom image analysis routines allows hundreds of individual cells to be automatically segmented and the mRNA-protein content to be digitally counted. Single-molecule intron and mRNA content is measured by single-molecule fluorescence in-situ hybridization (smFISH), while protein content is quantified though the use of antibody probes. To mimic immune response to bacterial infection, human monocytic leukemia cells (THP-1) were stimulated with lipopolysaccharide (LPS), and the expression of two inflammatory genes, IL1β (interleukin 1β) and TNF-α (tumor necrosis factor α), were simultaneously quantified by monitoring the intron, mRNA, and protein levels over time. The simultaneous labeling of cellular content allowed for a series of correlations at the single-cell level to be explored, both in the progressive maturation of a single gene (intron-mRNA-protein) and comparative analysis between the two immune response genes. In the absence of LPS stimulation, mRNA expression of IL1β and TNF-α were uncorrelated. Following LPS stimulation, mRNA expression of the two genes became more correlated, consistent with a model in which IL1β and TNF-α upregulation occurs in parallel through independent mechanistic pathways. This smFISH methodology can be applied to different complex biological systems to provide valuable insight into highly dynamic gene mechanisms that determine cell plasticity and heterogeneity of cellular response.

59 BASIC BIOLOGICAL SCIENCES↗

PDF Entity Annotation Tool (PEAT)

While different text mining approaches – including the use of Artificial Intelligence (AI) and other machine based methods - continue to expand at a rapid pace, the tools used by researchers to create the labeled datasets required for training, modeling, and evaluation remain rudimentary. Labeled datasets contain the target attributes the machine is going to learn; for example, training an algorithm to delineate between images of a car or truck would generally require a set of images with a quantitative description of the underlying features of each vehicle type. Development of labeled textual data that can be used to build natural language machine learning models for scientific literature is not currently integrated into existing manual workflows used by domain experts. Published literature is rich with important information, such as different types of embedded text, plots, and tables that can all be used as inputs to train ML/natural language processing (NLP) models, when extracted and prepared in machine readable formats. Currently, both normalized data extraction of use to domain experts and extraction to support development of ML/NLP models are labor intensive and cumbersome manual processes. Automatic extraction of data and information from formats such as PDFs that are optimized for layout and human readability, not machine readability. The PDF (Portable Document Format) Entity Annotation Tool (PEAT) was developed with the goal of allowing users to annotate publications within their current print format, while also allowing those annotations to be captured in a machine-readable format. One of the main issues with traditional annotation tools is that they require transforming the PDF into plain text to facilitate the annotation process. While doing so lessens the technical challenges of annotating data, the user loses all structure and provenance that was inherent in the underlying PDF. Also, textual data extraction from PDFs can be an error prone process. Challenges include identifying sequential blocks of text and a multitude of document formats (multiple columns, font encodings, etc.). As a result of these challenges, using existing tools for development of NLP/ML models directly from PDFs is difficult because the generated outputs are not interoperable. We created a system that allows annotations to be completed on the original PDF document structure, with no plain text extraction. The result is an application that allows for easier and more accurate annotations. In addition, by including a feature that grants the user the ability to easily create a schema, we have developed a system that can be used to annotate text for different domain-centric schemas of relevance to subject matter experts. Different knowledge domains require distinct schemas and annotation tags to support machine learning.

97 MATHEMATICS AND COMPUTING↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

AGR 5/6/7 Data Qualification Report for ATR Cycles 162B through 168A

This report provides the qualification status of experimental data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation. AGR-5/6/7 was conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tri-structural isotropic (TRISO) low-enriched fuel for use in high temperature gas-cooled reactors. The objectives of the AGR-5/6/7 experiments are to: (i) irradiate reference-design fuel particles to support fuel qualification, (ii) establish operating margins for the fuel beyond normal operating conditions, and (iii) provide irradiated-fuel performance data and irradiated-fuel samples for post-irradiation examination (PIE) and safety testing. The test train contains five separate capsules that were independently controlled and monitored. Each capsule contains multiple 12.51-mm-long compacts filled with low enriched uranium carbide/oxide (UCO) TRISO fuel particles. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) is to verify successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions in support of plant design and licensing. AGR 5/6/7 will also provide irradiated-fuel performance data on fission-gas release from failed particles during irradiation. The AGR-5/6/7 capsules were irradiated in the ATR northeast flux trap location. The experiment began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of 360.9 effective full power days. The AGR 5/6/7 experiment was able to remain in the reactor core during all three Powered Axial Locator Mechanism (PALM) cycles (163A, 165A, and 167A) without overheating its fuel compacts. This report includes irradiation monitoring data from nine ATR Cycles: 162B, 163A, 164A, 164B, 165A, 166A, 166B, 167A, and 168A, as stored in the Nuclear Data Management and Analysis System (NDMAS). During irradiation, data records consisted of instantaneous measurements recorded every minute and provided by text files automatically every 2 hours. The AGR 5/6/7 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates [capsule inlet, outlet, and downstream at detector], pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates and release to birth rate ratios [R/Bs]) for each of the five capsules. A total of 94,989,908 TC temperature and sweep gas data records were received and processed by NDMAS for AGR 5/6/7 irradiation. Of these records, 41,593,387 (or 43.7% of the total) met data collection and accuracy requirements and are labeled as Qualified. A total of 57,746,693 TC temperature readings were captured from 54 installed TCs. Among them, 10,034,676 TC temperature records (only 17.4%) were Qualified and 47,701,371 TC temperatures (or 82.6%) are Failed due to 48 TC failures (63.5%) and due to missing values (19.1%). To assess performance of the operational TCs, analysis of daily correlations between TCs found no evidence of virtual junction failure for any TCs. Analyses on control charts of TC temperature differences revealed trending in TC readings for TC2, 4, 5, and 13 in Capsule 3, but there is no conclusive indication of TC drift failure that caused those trends. Therefore, TC control charts are not used to disqualify TC data, but only for users’ consideration. For sweep gas flow rates, a total of 31,519,747 gas flow records (84.4%) are Qualified for use for AGR-5/6/7 experiment; 5,723,468 gas flow records (15.4%) are Failed due mostly to missing values; and 74,641 high sweep gas flow rates (0.2 %) are Trend. A large number of Failed missing TC temperature and gas flow values were caused by an error in the data output script that outputted a ‘NULL’ value when values were unchanged. This problem was fixed during the outage of Cycle 166B, which led to a substantially decreased number of missing values during the last three cycles. Nonetheless, a large amount of non-missing data remained because of the high data acquisition frequency (1-minute) and still provided sufficient data to effectively monitor the experiment as designed. For FPMS data, NDMAS received and processed fission product release and R/B data for nine ATR cycles, when ATR core reached full power during AGR 5/6/7 irradiation. These data consist of 110,388 release rate records and 110,388 R/B records for the twelve radionuclides (Kr 85m, Kr 87, Kr 88, Kr 89, Kr 90, Xe 131m, Xe 133, Xe 135, Xe 135m, Xe 137, Xe 138, and Xe 139) for each of the five capsules. Equivalent numbers of uncertainty records associated the release rates and R/B values were provided. To date, qualification status of the FPMS data stored in the NDMAS dat

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗