SEARCH · Search NASA
Results for “Axions”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Opening up a Window on the Postinflationary QCD Axion
Explore the source record for details and available documents.
No Evidence for Axions from Chandra Observation of the Magnetic White Dwarf RE J0317-853
Explore the source record for details and available documents.
Axion Dark Matter EXperiment 2A Cavity Characterization
We cooled the ADMX 2A cavities down to 5K and found the Q-factors for various tunings, which were about a factor of five larger than the Q-factors from the previous cooldown. We also found that the tuning mechanism with the piezo motor and gearbox is not currently equipped to handle cryogenic temperatures. We created an experimental warm bead pull setup using piezo motors, an alumina bead, a pulley system, and a distance calibrating script. We found that the bead pull method can successfully show us the reflection-induced electric field mode structure. This technique allowed us to differentiate between different TE and TM modes near mode crossings. However, some bead pull sweeps produced noisy or asymmetrical results, possibly due to asymmetries in the tuning rod orientation or antenna. Future iterations of the bead pull method can help us estimate the cavity form factor and maximize our scan range near mode crossings.
Electromagnetic modeling and science reach of DMRadio-m 3
DMRadio-m 3 is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. DMRadio-m 3 is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz (41 neV/𝑐 2 –0.83 μeV/𝑐 2 ) range, and to axions with 𝑔 𝑎𝛾𝛾 =𝑔 𝑎𝛾𝛾,DFSZ (30 MHz) =1.87 ×10 −17 GeV −1 over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m 3 , which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3𝜎 live scan time of 2.9 years.
Ultralight dark matter detection with levitated ferromagnets
Levitated ferromagnets act as ultraprecise magnetometers, which can exhibit high quality factors due to their excellent isolation from the environment. These instruments can be utilized in searches for ultralight dark matter candidates, such as axionlike dark matter or dark-photon dark matter. In addition to being sensitive to an axion-photon coupling or kinetic mixing, which produce physical magnetic fields, ferromagnets are also sensitive to the effective magnetic field (or “axion wind”) produced by an axion-electron coupling. While the dynamics of a levitated ferromagnet in response to a dc magnetic field have been well studied, all of these couplings would produce ac fields. In this work, we study the response of a ferromagnet to an applied ac magnetic field and use these results to project their sensitivity to axion and dark-photon dark matter. We pay special attention to the direction of motion induced by an applied ac field, in particular, whether it precesses around the applied field (similar to an electron spin) or librates in the plane of the field (similar to a compass needle). We show that existing levitated ferromagnet setups can already have comparable sensitivity to an axion-electron coupling as comagnetometer or torsion balance experiments. In addition, future setups can become sensitive probes of axion-electron coupling, dark-photon kinetic mixing, and axion-photon coupling, for ultralight dark matter masses m DM ≲ feV . Published by the American Physical Society 2024
Search for ultralight dark matter in the SuperMAG high-fidelity dataset
Ultralight dark matter, such as kinetically mixed dark-photon dark matter (DPDM) or axion-like-particle dark matter (axion DM), can source an oscillating magnetic-field signal at Earth’s surface. Previous work searched for this signal in a publicly available dataset of global magnetometer measurements maintained by the SuperMAG collaboration. This “low-fidelity” dataset reported measurements with a 1-min time resolution, allowing the search to set leading direct constraints on DPDM and axion DM with Compton frequencies f DM ≤ 1 / ( 1 min ) (corresponding to masses m DM ≤ 7 × 10 − 17 eV ). More recently, a dedicated experiment undertaken by the SNIPE Hunt collaboration has also searched for this same signal at higher frequencies f DM ≥ 0.5 Hz (or m DM ≥ 2 × 10 − 15 eV ). In this work, we search for this signal of ultralight DM in the SuperMAG “high-fidelity” dataset, which features a 1-sec time resolution, allowing us to probe the gap in parameter space between the low-fidelity dataset and the SNIPE Hunt experiment. The high-fidelity dataset exhibits lower geomagnetic noise than the low-fidelity dataset and features more data than the SNIPE Hunt experiment, making it a powerful probe of ultralight DM. Our search finds no robust DPDM or axion DM candidates. We set constraints on DPDM and axion DM parameter space for 10 − 3 Hz ≤ f DM ≤ 0.98 Hz (or 4 × 10 − 18 eV ≤ m DM ≤ 4 × 10 − 15 eV ). Our results are the leading direct constraints on both DPDM and axion DM in this mass range, and our DPDM constraint surpasses the leading astrophysical constraint in a narrow range around m A ′ ≈ 2 × 10 − 15 eV . Published by the American Physical Society 2024
High-Frequency Gravitational Wave Search with ABRACADABRA-10 cm
ABRACADABRA-10 cm has had great success as a pathfinder lumped-element axion dark matter experiment, setting limits on axion dark matter at the GUT scale. Now, using the interaction of gravitational waves with electrodynamics and a change in readout strategy, we use the ABRA-10 cm detector for the first search for high-frequency gravitational waves using a modified axion detector. Potential sources at these high frequencies (10 kHz to 5 MHz) include merging primordial black hole binaries or superradiance, among other beyond the standard model phenomena. This paper presents the design, results, and challenges from the ABRA-10 cm high-frequency gravitational wave search, showing it is possible to simultaneously look for axions and high-frequency gravitational waves with both searches matching theoretical expectations for sensitivity. Additionally, we conducted the first time series transient search with data from an axion experiment, achieving sensitivity to $10^{-4}$ in strain. Scaled directly to the next generation axion experiment, DMRadio-GUT, this sensitivity would imply a reach to 0.01 $M_{\odot}$ primordial black hole mergers at distances around 3 pc, with prospects to go significantly further with modifications to the readout.
Predicting the dark matter-baryon abundance ratio
We discuss relaxation solutions to the dark matter-baryon coincidence problem in the context of QCD axion dark matter. In relaxation solutions, a moduli dynamically adjusts the mass of dark matter and baryons until their energy densities are 𝒪(1) the same. Because the QCD axion is heavily connected to QCD, scanning the QCD axion mass inherently also scans the proton mass. In the context of relaxation solutions, this implies that the ratio of dark matter to baryon abundances (Ω DM /Ω B ) is a ratio of beta functions showing that these models can only accommodate discrete values of ΩDM/ΩB thereby “predicting” the ratio of the dark matter to baryon abundances. The original composite axion model has only a single integer degree of freedom 𝑁, the size of the gauge group, and we show that when 𝑁 =8 the observed value of Ω DM /Ω B =5.36 is reproduced to within its percent level error bars. Novel tests of this model include more precise measurements of Ω DM /Ω B , a better lattice determination of the dependence of the proton mass on the high energy QCD gauge coupling, as well as more traditional tests such as fifth force experiments.
NuSTAR Bounds on Radiatively Decaying Particles from M82
Axions and other putative feebly interacting particles with a mass of tens to several hundreds of keVs can be produced in stellar cores with a Lorentz boost factor E a / m a ≲ 10 . Thus, starburst galaxies such as M82 are efficient factories of slow axions. Their decay a → γ γ would produce a large flux of x-ray photons, peaking around 100 keV and spread around the Galaxy by an angle that can be relatively large. We use observations of the Nuclear Spectroscopic Telescope Array mission to show that the absence of these features can constrain 30–500 keV axion masses into uncharted regions for axion-photon coupling of g a γ ∼ 10 − 10 – 10 − 12 GeV − 1 . Our argument can be applied to other heavy feebly interacting particles and astrophysical sources that are hot enough to produce them, yet cold enough to avoid large boost factors which slow down the decay. Published by the American Physical Society 2025
Quantum sensing for fundamental physics efforts at SQMS
One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.
What can solve the strong CP problem?
Three possible strategies have been advocated to solve the strong CP problem. The first is the axion, a dynamical mechanism that relaxes any initial value of the CP violating angle $\overline{θ}$ to zero. The second is the imposition of new symmetries that are believed to set $\overline{θ}$ to zero in the UV. The third is the acceptance of the fine tuning of parameters. We argue that the latter two solutions do not solve the strong CP problem. The θ term of QCD is not a parameter — it does not exist in the Hamiltonian. Rather, it is a property of the quantum state that our universe finds itself in, arising from the fact that there are CP violating states of a CP preserving Hamiltonian. It is not eliminated by imposing parity as a symmetry since the underlying theory is already parity symmetric and that does not preclude the existence of CP violating states. Moreover, since the value of θ realized in our universe is a consequence of measurement, it is inherently random and cannot be fine tuned by choice of parameters. Rather any fine tuning would require a tuning between parameters in the theory and the random outcome of measurement. Our results considerably strengthen the case for the existence of the axion and axion dark matter. The confusion around θ arises from the fact that unlike classical mechanics, the Hamiltonian and Lagrangian are not equivalent in quantum mechanics. The Hamiltonian defines the differential time evolution, whereas the Lagrangian is a solution to this evolution. Consequently, initial conditions could in principle appear in the Lagrangian but not in the Hamiltonian. This results in aspects of the initial condition such as θ misleadingly appearing in the Lagrangian as parameters. We comment on the similarity between the θ vacua and the violations of the constraint equations of classical gauge theories in quantum mechanics.
Cosmology of dark energy radiation
In this work, we quantify the cosmological signatures of dark energy radiation—a novel description of dark energy, which proposes that the dynamical component of dark energy is comprised of a thermal bath of relativistic particles sourced by thermal friction from a slowly rolling scalar field. For a minimal model with particle production emerging from first principles, we find that the abundance of radiation sourced by dark energy can be as large as Ω DER = 0.03, exceeding the bounds on relic dark radiation by three orders of magnitude. Although the background and perturbative evolution of dark energy radiation are distinct from Quintessence, we find that current and near-future cosmic microwave background and supernova data will not distinguish these models of dark energy. We also find that our constraints on all models are dominated by their impact on the expansion rate of the Universe. Considering extensions that allow the dark radiation to populate neutrinos, axions, and dark photons, we evaluate the direct detection prospects of a thermal background comprised of these candidates consistent with cosmological constraints on dark energy radiation. Our study indicates that a resolution of ~6 meV is required to achieve sensitivity to relativistic neutrinos compatible with dark energy radiation in a neutrino capture experiment on tritium. We also find that dark matter axion experiments lack sensitivity to a relativistic thermal axion background, even if enhanced by dark energy radiation, and dedicated search strategies are required to probe new parameter space. We derive constraints arising from a dark photon background from oscillations into visible photons, and find that viable parameter space can be explored with the late dark energy radiation experiment.
Hunting Dark Matter Lines in the Infrared Background with the James Webb Space Telescope
Dark matter particles with a mass around 1 eV can decay into near-infrared photons. Utilising available public blank sky observations from the NIRSpec IFU on the James Webb Space Telescope (JWST), we search for a narrow emission line due to decaying dark matter and derive leading constraints in the mass range 0.8-3 eV on the decay rate to photons, and more specifcally, on the axion-photon coupling for the case of axion-like particles. We exclude τ < 3.5 x 10 26 s at m DM ≃ 0.8 eV and, in the case of axions, g aγγ > 1.3 x 10 -11 GeV -1 for m a ≃ 2.2 eV. Our results do not rely on dedicated observations, rather we use blank sky observations intended for sky subtraction, and thus our reach may be automatically strengthened as JWST continues to observe.
Review of Particle Physics
The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised.
Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector
The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing experiment searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a sub-experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of all converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within 50 $\mu$m in three dimensions.
Constraints on dark matter from intergalactic radiation
Several of the dark matter candidates that have been proposed are believed to be unstable to decay, which would contribute photons to the radiation field between galaxies. The main candidates of this type are light neutrinos and axions, primordial mini-black holes, and a nonzero 'vacuum' energy. All of these can be constrained in nature by observational data on the extragalactic background light and the microwave background radiation. Black holes and the vacuum can be ruled out as significant contributors to the 'missing mass'. Light axions are also unlikely candidates; however, those with extremely small rest energies (the so-called 'invisible' axions) remain feasible. Light neutrinos, like those proposed by Sciama, are marginally viable. In general, we believe that the intergalactic radiation field is an important way of constraining all types of dark matter.
Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector
The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, an experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the $z$ dimension.