Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Energy Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Powering Up Secure and Reliable Operations at the Port of Honolulu's Kapalama Container Terminal

The National Laboratory of the Rockies (NLR) is providing resilience planning support to the Pasha Group, the operator of Kapalama Container Terminal (KCT) at the Port of Honolulu, by exploring how distributed clean energy resources could help the terminal sustain a 36-hour outage and continue emergency operations. The Department of Energy's Energy Transitions Initiative (ETI) aims to advance self-reliant island and remote communities by promoting resilient, affordable, and sustainable clean energy resources.

25 ENERGY STORAGE↗

Laboratory evaluation of a pilot cell battery protection system for photovoltaic applications

An energy storage method for the 3.5 kW battery power system was investigated. The Pilot Cell Battery Protection System was tested for use in photovoltaic power systems and results show that this is a viable method of storage battery control. The method of limiting battery depth of discharge has the following advantages: (1) temperature sensitivity; (2) rate sensitivity; and (3) state of charge indication. The pilot cell concept is of interest in remote stand alone photovoltaic power systems. The battery can be protected from damaging overdischarge by using the proper ratio of pilot cell capacities to main battery capacity.

Cataldo, R. L.↗

White Paper on Case Study of Safe Installation of Second-Life Energy Storage System

This technical report provides for a case study for the safe installation of a second-life, or repurposed, battery, that has been reconfigured for use as a stationary energy storage systems (ESS). Driven by legislative requirements such as California Senate Bill 615 and projections that retired EV batteries could meet a substantial portion of U.S. grid ESS needs beginning in 2035, the repurposing of EV batteries is anticipated to grow significantly. However, safety concerns arise from the effects of aging, unknown prior usage history, and changes in thermal runaway behavior, which may increase failure risks compared to new batteries. NFPA 855, the predominant U.S. standard for ESS installation, mandates that second-life batteries meet all requirements for new batteries, with repurposers complying with UL 1974 in addition to obtaining UL 9540 and UL 1973 listings. These are certifications that few repurposers have achieved and represent a regulatory barrier to entry for the market as a whole.

47 OTHER INSTRUMENTATION↗

Ferromagnetic Atomic d ‐ p Orbital Hybridization for Promoting Al‐S Batteries

Rechargeable aluminum‐sulfur batteries (Al‐S) are emerging as a promising alternative energy storage system beyond lithium‐ion batteries due to their high energy density, abundant material resources, and economic efficiency. However, their practical application remains challenged by sluggish conversion kinetics, polysulfide shuttling, and low sulfur cathode utilization. While extensive studies have focused on enhancing polysulfide adsorption through catalytic strategies, the roles of electronic structure in dictating catalytic performance remain underexplored. Here, this work unveils the critical effect of unpaired electronic structure on the catalytic performance of single atom ferromagnetic transition metals through a systematic evaluation of three typical atomically dispersed ferromagnetic single atoms—Fe, Co, and Ni—supported on porous carbon (denoted as PC‐SAFAs). Comprehensive characterizations and density functional theory (DFT) calculations reveal that the PC‐SAFe catalysts, exhibiting the highest spin polarization arising from unpaired electrons, demonstrate the strongest interactions with polysulfide, thereby facilitating rapid and reversible polysulfide conversion reactions. Consequently, Al‐S batteries incorporating the optimized PC‐SAFe cathode achieve an impressive specific capacity of 508.8 mAh g −1 at 1.0 A g −1 after 500 cycles, along with much improved rate capability. In conclusion, this work provides a deeper understanding of the role of electronic structure in catalytic chemistry, and offers new insights for developing high‐performance Al‐S batteries.

36 MATERIALS SCIENCE↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Mechanistic insights into CO 2 capture and electrochemical conversion in nonaqueous Na–CO 2 batteries

Developing efficient energy storage systems that capture and convert CO 2 is critical for mitigating carbon emissions. Here, we report a Na–CO 2 battery with ruthenium dioxide (RuO 2 ) cathode catalysts and propane-1,3-diamine (PDA) as an electrolyte additive to enhance CO 2 capture and conversion efficiency. The integration of CO 2 adsorption and electrochemical reduction facilitates activation of the inert CO 2 molecule and circumvents gas–solid–liquid ternary-phase reactions at the interface. We employed density functional theory (DFT) calculations to systematically unravel the reaction mechanisms and energetics governing CO 2 reduction, both with and without PDA. Our results reveal an energetically favorable pathway toward the formation of Na 2 CO 3 and C as final discharge products, rather than sodium oxalate (Na 2 C 2 O 4 ). The CO 2 –amine adduct facilitates charge transfer from PDA to CO 2 , which results in activation of CO 2 . The kinetics of CO 2 conversion and regeneration of PDA were found to be significantly enhanced on the RuO 2 surface compared to the bulk electrolyte. More importantly, pre-activation of CO 2 via the amine–CO 2 adduct lowers the total overpotential to 2.44 V, compared to 3.13 V without PDA. This study provides fundamental insights into CO 2 electroreduction in Na–CO 2 batteries and underscores the promise of electrolyte engineering for sustainable CO 2 utilization and high-performance energy storage.

25 ENERGY STORAGE↗

Nickel-Hydrogen Battery Cell Life Test Program Update for the International Space Station

NASA and Boeing North America are responsible for constructing the electrical power system for the International Space Station (ISS), which circles the Earth every 90 minutes in a low Earth orbit (LEO). For approximately 55 minutes of this orbit, the ISS is in sunlight, and for the remaining 35 minutes, the ISS is in the Earth s shadow (eclipse). The electrical power system must not only provide power during the sunlight portion by means of the solar arrays, but also store energy for use during the eclipse. Nickel-hydrogen (Ni/H2) battery cells were selected as the energy storage systems for ISS. Each battery Orbital Replacement Unit (ORU) comprises 38 individual series-connected Ni/H2 battery cells, and there are 48 battery ORU s on the ISS. On the basis of a limited Ni/H2 LEO data base on life and performance characteristics, the NASA Glenn Research Center at Lewis Field commenced testing through two test programs: one in-house and one at the Naval Surface Warfare Center in Crane, Indiana.

Miller, Thomas B.↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

Regenerative Fuel Cell Systems for Lunar Surface Applications

A discrete Regenerative Fuel Cell (RFC), comprised of a Proton Exchange Membrane (PEM) Fuel Cell (FC) system integrated with a PEM Electrolyzer (EZ) system, can provide energy conversion and storage options for applications where batteries are not practical. This includes missions on the lunar surface where long charge and discharge periods result in extremely high battery system mass for sufficient energy storage. While both PEM FC and PEM EZ are mature terrestrial technologies, there is still a lot of development needed for aerospace applications. Integrating the PEM FC and PEM EZ systems together requires the integration of multiple thermal, fluid, and electrical subsystems, increasing the complexity of the overall RFC system. Additionally, Balance of Plant (BoP) components and subsystems play a crucial role in the effective performance to maximize the RFC round trip efficiency. This presentation will give a high-level overview of RFCs, select BoP components including a catalytic recombiner and gas drying equipment, and the current testing that is being done on the RFC project at NASA GRC.

Jessica Cashman↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Analysis of Water Surplus at the Lunar Outpost

This paper evaluates the benefits to the lunar architecture and outpost of having a surplus of water, or a surplus of energy in the form of hydrogen and oxygen, as it has been predicted by Constellation Program's Lunar Surface System analyses. Assumptions and a scenario are presented leading to the water surplus and the revolutionary surface element options for improving the lunar exploration architecture and mission objectives. For example, some of the elements that can benefit from a water surplus are: the power system energy storage can minimize the use of battery systems by replacing batteries with higher energy density fuel cell systems; battery packs on logistics pallets can also be minimized; mobility asset power system mass can be reduced enabling more consumables and extended roving duration and distance; small robotic vehicles (hoppers) can be used to increase the science exploration range by sending round-trip robotic missions to anywhere on the Moon using in-situ produced propellants.

Santiago-Maldonado, Edgardo↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying [Pacific Northwest National Laborato↗

Advanced subsystems development

The concept design for a small (less than 10 MWe) solar thermal electric generating plant was completed using projected 1985 technology. The systems requirements were defined and specified. The components, including an engineering prototype for one 15 kWe module of the generating plant, were conceptually designed. Significant features of the small solar thermal power plant were identified as the following: (1) 15 kWe Stirling-cycle engine/alternator with constant power output; (2) 10 meter point-focusing paraboloidal concentrator with cantilevered cellular glass reflecting panels; (3) primary heat pipe with 800 C output solar cavity receiver; (4) secondary heat pipe with molten salt thermal energy storage unit; (5) electric energy transport system; and (6) advanced battery energy storage capability.

Livingston, F. R.↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

Performance and economic risk evaluation of dispersed solar thermal power systems by Monte Carlo simulation

A preliminary comparative evaluation of dispersed solar thermal power plants utilizing advanced technologies available in 1985-2000 time frame is under way at JPL. The solar power plants of 50 KWe to 10 MWe size are equipped with two axis tracking parabolic dish concentrator systems operating at temperatures in excess of 1000 F. The energy conversion schemes under consideration include advanced steam, open and closed cycle gas turbines, stirling, and combined cycle. The energy storage systems include advanced batteries, liquid metal, and chemical. This paper outlines a simple methodology for a probabilistic assessment of such systems. Sources of uncertainty in the development of advanced systems are identified, and a computer Monte Carlo simulation is exercised to permit an analysis of the tradeoffs of the risk of failure versus the potential for large gains. Frequency distribution of energy cost for several alternatives are presented.

Manvi, R.↗

Development and Testing of an Ultracapacitor Based Uninterruptible Power Supply (UPS) System

The NASA Glenn Research Center (GRC) initiated the development and testing of an ultracapacitor based uninterruptible power supply (UPS) system as a means to provide backup power for the many critical NASA applications. A UPS system typically utilizes batteries for energy storage. The battery is the most vulnerable part of the UPS system, requiring regular maintenance and replacement. Battery performance is also extremely temperature dependent. Ultracapacitors are ideal for UPS systems where long life, maintenance free operation, and excellent low temperature performance is essential. State of the art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance, and to provide voltage balancing. Ultracapacitors can be charged extremely rapidly and supply high current, which are essential characteristics for an effective UPS system. Charging ultracapacitors is significantly less complex than charging batteries since there is no chemical reaction occurring while charging ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in a UPS system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗