Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Energy Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Regenerative Fuel Cell Systems for Lunar Surface Applications

A discrete Regenerative Fuel Cell (RFC), comprised of a Proton Exchange Membrane (PEM) Fuel Cell (FC) system integrated with a PEM Electrolyzer (EZ) system, can provide energy conversion and storage options for applications where batteries are not practical. This includes missions on the lunar surface where long charge and discharge periods result in extremely high battery system mass for sufficient energy storage. While both PEM FC and PEM EZ are mature terrestrial technologies, there is still a lot of development needed for aerospace applications. Integrating the PEM FC and PEM EZ systems together requires the integration of multiple thermal, fluid, and electrical subsystems, increasing the complexity of the overall RFC system. Additionally, Balance of Plant (BoP) components and subsystems play a crucial role in the effective performance to maximize the RFC round trip efficiency. This presentation will give a high-level overview of RFCs, select BoP components including a catalytic recombiner and gas drying equipment, and the current testing that is being done on the RFC project at NASA GRC.

Jessica Cashman↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Analysis of Water Surplus at the Lunar Outpost

This paper evaluates the benefits to the lunar architecture and outpost of having a surplus of water, or a surplus of energy in the form of hydrogen and oxygen, as it has been predicted by Constellation Program's Lunar Surface System analyses. Assumptions and a scenario are presented leading to the water surplus and the revolutionary surface element options for improving the lunar exploration architecture and mission objectives. For example, some of the elements that can benefit from a water surplus are: the power system energy storage can minimize the use of battery systems by replacing batteries with higher energy density fuel cell systems; battery packs on logistics pallets can also be minimized; mobility asset power system mass can be reduced enabling more consumables and extended roving duration and distance; small robotic vehicles (hoppers) can be used to increase the science exploration range by sending round-trip robotic missions to anywhere on the Moon using in-situ produced propellants.

Santiago-Maldonado, Edgardo↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying [Pacific Northwest National Laborato↗

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems↗

Advanced subsystems development

The concept design for a small (less than 10 MWe) solar thermal electric generating plant was completed using projected 1985 technology. The systems requirements were defined and specified. The components, including an engineering prototype for one 15 kWe module of the generating plant, were conceptually designed. Significant features of the small solar thermal power plant were identified as the following: (1) 15 kWe Stirling-cycle engine/alternator with constant power output; (2) 10 meter point-focusing paraboloidal concentrator with cantilevered cellular glass reflecting panels; (3) primary heat pipe with 800 C output solar cavity receiver; (4) secondary heat pipe with molten salt thermal energy storage unit; (5) electric energy transport system; and (6) advanced battery energy storage capability.

Livingston, F. R.↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

Performance and economic risk evaluation of dispersed solar thermal power systems by Monte Carlo simulation

A preliminary comparative evaluation of dispersed solar thermal power plants utilizing advanced technologies available in 1985-2000 time frame is under way at JPL. The solar power plants of 50 KWe to 10 MWe size are equipped with two axis tracking parabolic dish concentrator systems operating at temperatures in excess of 1000 F. The energy conversion schemes under consideration include advanced steam, open and closed cycle gas turbines, stirling, and combined cycle. The energy storage systems include advanced batteries, liquid metal, and chemical. This paper outlines a simple methodology for a probabilistic assessment of such systems. Sources of uncertainty in the development of advanced systems are identified, and a computer Monte Carlo simulation is exercised to permit an analysis of the tradeoffs of the risk of failure versus the potential for large gains. Frequency distribution of energy cost for several alternatives are presented.

Manvi, R.↗

Development and Testing of an Ultracapacitor Based Uninterruptible Power Supply (UPS) System

The NASA Glenn Research Center (GRC) initiated the development and testing of an ultracapacitor based uninterruptible power supply (UPS) system as a means to provide backup power for the many critical NASA applications. A UPS system typically utilizes batteries for energy storage. The battery is the most vulnerable part of the UPS system, requiring regular maintenance and replacement. Battery performance is also extremely temperature dependent. Ultracapacitors are ideal for UPS systems where long life, maintenance free operation, and excellent low temperature performance is essential. State of the art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance, and to provide voltage balancing. Ultracapacitors can be charged extremely rapidly and supply high current, which are essential characteristics for an effective UPS system. Charging ultracapacitors is significantly less complex than charging batteries since there is no chemical reaction occurring while charging ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in a UPS system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗

Interactive multiscale modeling to bridge atomic properties and electrochemical performance in Li-CO 2 battery design

Li-CO 2 batteries are promising energy storage systems due to their high theoretical energy density and CO 2 fixation capability, relying on reversible Li 2 CO 3 /C formation during discharge/charge cycles. Here, we present a multiscale modeling framework integrating Density Functional Theory (DFT), Ab-Initio Molecular Dynamics (AIMD), classical Molecular Dynamics (MD), and Finite Element Analysis (FEA) to investigate atomic and cell-level properties. The considered Li-CO 2 battery consists of a lithium metal anode, an ionic liquid electrolyte, and a carbon cloth cathode with Sb 0.67 Bi 1.33 Te 3 catalyst. DFT and AIMD determined the electrical conductivities of Sb 0.67 Bi 1.33 Te 3 and Li 2 CO 3 using the Kubo–Greenwood formalism and studied the CO 2 reduction mechanism on the cathode catalyst. MD simulations calculated the CO 2 diffusion coefficient, Li + transference number, ionic conductivity, and Li + solvation structure. The FEA model, parameterized with atomistic simulation data, reproduced the available experimental voltage–capacity profile at 1 mA/cm 2 and revealed spatio-temporal variations in Li 2 CO 3 /C deposition, porosity, and CO 2 concentration dependence on discharge rates in the cathode. Accordingly, Li 2 CO 3 can form large and thin film deposits, leading to dispersed and local porosity changes at 0.1 mA/cm 2 and 1 mA/cm 2 , respectively. The capacity decreases exponentially from 81,570 mAh/g at 0.1 mA/cm 2 to 6200 mAh/g at 1 mA/cm 2 , due to pore clogging from excessive discharge product deposition that limits CO 2 transport to the cathode interior. Therefore, the performance of Li-CO 2 batteries can be improved by enhancing CO 2 transport, regulating Li 2 CO 3 deposition, and optimizing cathode architecture.

Battery performance↗

Anion sublattice design enables superionic conductivity in crystalline oxyhalides

Solid-state batteries are attractive energy storage systems as a result of their inherent safety, but their development hinges on advanced solid-state electrolytes (SSEs). Most SSEs remain largely confined to single-anion systems (e.g., sulfides, oxides, halides, and polymers). Through mixed-anion design strategy, we develop crystalline Li 3 Ta 3 O 4 Cl 10 (LTOC) and its derivatives with excellent ionic conductivities (up to 13.7 millisiemens per centimeter at 25°C) and electrochemical stability. The LTOC structure features mixed-anion spiral chains, consisting of corner-shared oxygen and terminal chlorine atoms, which induces continuous “tetrahedron-tetrahedron” Li-ion migration pathways with low energy barriers. Additionally, LTOC demonstrates holistic cathode compatibility, enabling solid-state batteries operation at 4.9 volts versus Li/Li + and low temperature, down to −50°C. In conclusion, these findings describe a promising class of superionic conductors for high-performance solid-state batteries.

Zhao, Feipeng [Western University, London, ON (Can↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Multifaceted effects of ring fusion on the stability of charged dialkoxyarene redoxmers

Due to their almost unlimited scalability, redox flow batteries can make versatile and affordable energy storage systems. Redox active materials (redoxmers) in these batteries largely define their electrochemical performance, including the life span of the battery that depends on the stability of charged redoxmers. Here, in this study, we examine the effects of expanding the pi-system in the arene rings on the chemical stability of dialkoxyarene redoxmers that are used to store positive charge in RFBs. When 1,4-dimethoxybenzene is pi-extended to 1,4 dimethoxynaphthalene, a lower redox potential, improved kinetic stability, and longer cycling life are observed. However, when an additional ring is fused to make 9,10-dimethoxyanthracene, the radical cation undergoes rapid O -dealkylation possibly due to increased steric strain that drives methoxy out of the arene plane thus breaking the pi-conjugation with O 2p orbitals. On the other hand, the planar structure of 1,4-dimethoxynaphthalene may facilitate second -order reactions of radical cations leading to their neutralization in the bulk. Our study suggests that extending the pi-system changes reactivity in multiple (sometimes, opposite) ways, so lowering the oxidation potential through pi-conjugation to improve redoxmer stability should be pursued with caution.

25 ENERGY STORAGE↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗