TDRSS Battery Life Cycle Tests Interim Report
The design features of the tracking and data relay satellite system battery are described. Some of the life cycle tests performed on the battery are reported.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The design features of the tracking and data relay satellite system battery are described. Some of the life cycle tests performed on the battery are reported.
Life cycle testing on a battery is reported. The cells were built in 1975, put into battery in 1976, and flown in 1977 in low Earth orbit.
Empirical formula represents performance of electrical storage batteries. Formula covers many battery types and includes numerous coefficients adjusted to fit peculiarities of each type. Battery and load parameters taken into account include power density in battery, discharge time, and electrolyte temperature. Applications include electric-vehicle "fuel" gages and powerline load leveling.
A “battery passport” is a digital record that provides comprehensive information about an individual battery across its life cycle. This concept has been introduced by Battery Regulation (EU) 2023/1542 [1], which applies to batteries for electric vehicles (EVs), industrial batteries with a capacities greater than 2 kWh, and batteries for light means of transport (LMT) greater than 2kWh sold in the European Union (EU) market – impacting manufacturers and exporters across multiple jurisdictions globally. Among its reporting mandates, a key feature of battery passports is the requirement for a carbon footprint (CF) calculation methodology supported by enhanced data granularity to enable traceable and verifiable CF results. While no other jurisdictions have yet adopted formal battery passport requirements like the EU’s, some are developing CF calculation methods to comply with the EU Battery Regulation or are creating CF-related regulations that could evolve in a similar direction, reflecting the growing importance of battery CF guidelines for manufacturers seeking to remain competitive in global markets.
Membrane and absorber screening tests for alkaline battery separators
The setup and testing of battery systems are described. Basic control mode, basic block diagrams and circuitry are given.
This presentation reviews the history of the Earth Radiation Budget Satellite (ERBS) and the problems which were experienced with the batteries. After two cells shorted on the first Battery, the decision was made to take battery 1 of line in late 1992. This left the second battery supporting all loads. The second battery began to experience problems in 1998 into 1999. The decision was made to bring the first battery on line and take the second battery off line. The steps to switching the batteries are reviewed, and the results are discussed.
Explore the source record for details and available documents.
Features of the first operational nickel hydrogen battery are described as well as experiences encountered during its testing and installation. Battery performance since launching of the NTS-2 satellite is discussed.
The battery was a three ampere hour nickel cadmium prismatic cell. The battery consists of 20 cells connected in series and there were two batteries per spacecraft. The battery operations (voltage and temperature) that the spacecraft sees during a normal operational day are discussed.
Previous reports have shown how a battery model was developed using porous electrode theory. Since then the model has been upgraded and expanded. These upgrades include oxygen reation and positive electrode intercalation and proton diffusion. The effects of additional details of the solid state physics of the nickel electrode will be reported here.
Ethylene/methyl acrylate copolymer synthesis for silver-zinc battery separators
Nonmagnetic hermetically sealed battery case made of epoxy resin and woven glass tape for use with electrochemical cells in spacecraft
Power is essential for crewed and uncrewed spaceflight operations. Spacecraft batteries are designed and tested to be safe under extreme environmental conditions.
Molten salt battery has been developed with theoretical energy density of 5.2 j/kg (650 W-h/lb). Battery, which operates at 150 C, can be used in primary mode or as rechargeable battery. Battery has aluminum anode and chlorine cathode. Electrolyte is mixture of AlCl3, NaCl, and some alkali metal halide such as KCl.
Simulator verifies proper operation of a battery cell voltage-monitoring device. It also contains variable ac voltage to ascertain that a battery scanner will perform its function at all possible ac voltages.
Method of constructing nickel cadmium batteries prevents excessive gas buildup and allows hermetic sealing of battery for increased service life and reduced maintenance cost.
Rechargeable high energy density battery based on aluminum and chlorine carbon electrodes and molten aluminum chloride-alkali chloride eutectic as electrolyte