Search NASA⌕ Search

SEARCH · Search NASA

Results for “Body Reference Frame”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

171 records · Page 10

Optimised Post-Exposure Image Sharpening Code for L3-CCD Detectors

As light from celestial bodies traverses Earth's atmosphere, the wavefronts are distorted by atmospheric turbulence, thereby lowering the angular resolution of ground-based imaging. Rapid time-series imaging enables Post-Exposure Image Sharpening (PEIS) techniques, which employ shift-and-add frame registration to remove the tip-tilt component of the wavefront error--as well as telescope wobble, thus benefiting all observations. Further resolution gains are possible by selecting only frames with the best instantaneous seeing--a technique sometimes calling 'Lucky Imaging'. We implemented these techniques in the 1990s, with the TRIFFID imaging photon-counting camera, and its associated data reduction software. The software was originally written for time-tagged photon-list data formats, recorded by detectors such as the MAMA. This paper describes our deep re-structuring of the software to handle the 2-d FITS images produced by Low Light Level CCD (L3-CCD) cameras, which have sufficient time-series resolution (>30 Hz) for PEIS. As before, our code can perform straight frame co-addition, use composite reference stars, perform PEIS under several different algorithms to determine the tip/tilt shifts, store 'quality' and shift information for each frame, perform frame selection, and generate exposure-maps for photometric correction. In addition, new code modules apply all 'static' calibrations (bias subtraction, dark subtraction and flat-fielding) to the frames immediately prior to the other algorithms. A unique feature of our PEIS/Lucky Imaging code is the use of bidirectional wiener-filtering. Coupled with the far higher sensitivity of the L3-CCD over the previous TRIFFID detectors, much fainter reference stars and much narrower time windows can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking

Purpose: The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowledge.Methods: The system utilizes an emerging marker-less and laser-based active triangulation (AT) sensor that delivers sparse but highly accurate 3D measurements in real-time. These sparse position measurements are registered with a dense reference surface extracted from planning data. Thereby a dense displacement field is recovered, which describes the spatio-temporal 4D deformation of the complete patient body surface, depending on the type and state of respiration. It yields both a reconstruction of the instantaneous patient shape and a high-dimensional respiratory surrogate for respiratory motion tracking. The method is validated on a 4D CT respiration phantom and evaluated on both real data from an AT prototype and synthetic data sampled from dense surface scans acquired with a structured-light scanner.Results: In the experiments, the authors estimated surface motion fields with the proposed algorithm on 256 datasets from 16 subjects and in different respiration states, achieving a mean surface reconstruction accuracy of ±0.23 mm with respect to ground truth data—down from a mean initial surface mismatch of 5.66 mm. The 95th percentile of the local residual mesh-to-mesh distance after registration did not exceed 1.17 mm for any subject. On average, the total runtime of our proof of concept CPU implementation is 2.3 s per frame, outperforming related work substantially.Conclusions: In external beam radiation therapy, the approach holds potential for patient monitoring during treatment using the reconstructed surface, and for motion-compensated dose delivery using the estimated 4D surface motion field in combination with external-internal correlation models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Theoretically Scaled Biomechanical Models

BACKGROUND An investigation into incorporating space suit aspects required a 50th-percentile male model which was not part of the existing dataset of models. Previously, theoretical models for 5th-percentile female and 95th-percentile male were created utilizing a scaled test subject as close as possible to the target height and weight. Scaling factors were created by taking the height ratio and applying it uniformly to the model body segments, then fine tuning to ensure the theoretical model’s height is as expected. This study was initiated to examine the existing method of isometrically scaling in OpenSim [1,2] and to create alternative methods which do not rely on an existing subject being close in height and weight to the theoretical model of interest. Generating a theoretical biomechanical model provides additional abilities without the reliance on available OpenSim models or real subjects. Gained abilities include creating different percentile models and attaining representative anthropometry for any target height/weight, such as targeting specific crew populations or gaps within the current dataset. METHODS AND RESULTS This study includes 3 methods for generating the theoretical model; utilizing the modified unscaled OpenSim Full Body Rajagopal Model (FBRM) [3,4], a dataset of scaled OpenSim models, and existing scaling factors from Dumas et al. [5]. All methods use the Anthropometric Survey of US Army Personnel (ANSUR II) [6] as an input of necessary anthropometric measurements. The following measurements are retrieved from the ANSUR II collection: mass, stature, cervicale height, acromial height, axilla height, waist height, trochanterion height, lateral femoral epicondyle height, lateral malleolus height, acromion-radiale length, radiale-stylion length, palm length, ball of foot length, bicristal breadth, bimalleolar breadth. Some of the measurements are direct segment lengths and others are utilized to derive segment lengths. Height, weight, and age ranges are the required inputs to parse the collection for a mean value of the measurements. A simple iterative process may be necessary for the output of mean mass and stature consistent with the theoretical model of interest. In some cases, one may specify exact values instead of a range but that is dependent upon whether those exact values pertain to a single subject from the ANSUR II collection. Equations from Dumas et al. were used to calculate scaling factors for the two methods that utilize OpenSim scaled and unscaled models. In the third method, Dumas’ scaling factors were used directly instead of generating our own. After scaling factors are achieved, they are applied along with the mass and segment lengths retrieved from ANSUR II in order to calculate the segment mass, Center of Mass (CoM), mass Moment of Inertia (MoI), and the joint location in the parent frame. The theoretical models from the different methods were compared to the previous existing method of isometrically scaling in OpenSim, as well as the standards found in NASA STD-3000 [7] and the NASA Human Integration Design Handbook [8]. The whole-body center of mass is the main comparison performed between the models and the standards. The body segment mass properties were also compared when possible. In some cases, the standards do not provide complete data, or the center of mass location is not provided with respect to the appropriate joint coordinate system. For a 50th-percentile male subject, results from isometric scaling in OpenSim and the method utilizing the unscaled FBRM were compared to the standards in NASA STD-3000. According to the standard, the whole-body vertical CoM location was taken from the head vertex to the CoM. The standards provide 80.2 cm for the CoM vertical component whereas isometric scaling in OpenSim and utilizing the unscaled FBRM provide 82.2 and 82.3 cm, respectively. Through definition, the whole-body CoM in the medial/lateral direction agreed across the models. Investigation is on-going to clearly identify the reference point pertaining to dorsal/ventral whole-body CoM position in standards and relate that to the theoretical models. REFERENCES [1] Delp, S.L., et al., “OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement”, IEEE Transactions on Biomedical Engineering, (2007). [2] Seth, A., Hicks J.L., Uchida, T.K., Habib, A., Dembia, C.L., Dunne, J.J., Ong, C.F., DeMers, M.S., Rajagopal, A., Millard, M., Hamner, S.R., Arnold, E.M., Yong, J.R., Lakshmikanth, S.K., Sherman,n M.A., Delp, S.L. OpenSim: Simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement. Plos Computational Biology, 14(7). (2018) [3] R. K. Huffman, W. K. Thompson, C. A. Gallo, L. J. Quiocho, “Improvement of Scaling and Inverse Kinematic Results with Additional Upper Body Joints Added to Opensim Rajagopal Model”, NASA Human Research Program Investigator’s Workshop, (2019). [4] Huffman R.K., Thompson W., Gallo C., “Modified OpenSim Rajagopal Full Body Model”, New Technology Report, MSC-26872-1. (August 2020). [5] Dumas R., Cheze L. and Verriest J., 2007. “Adjustments to McConville et al. and Young et al. body segment inertial parameters”. Journal of Biomechanics 40, pp. 543-553 [6] Gordon C.C., 2012 “Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics”, US Army Natick Soldier RD&E Center. [7] NASA STD-3000/REV-B, 1995. “The Man-System Integration Standards” [8] NASA/SP-2010-3407/REV-1, 2014. “The Human Integration Design Handbook (HIDH)”

F N Matari↗

Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic measurements during hardware motion and contact. While performing dynamic testing of an active docking system, researchers found that the data from the motion platform, test hardware and two external measurement systems exhibited frame offsets and rotational errors. While the errors were relatively small when considering the motion scale overall, they substantially exceeded the individual accuracies for each component. After evaluating both the static and dynamic measurements, researchers found that the static measurements introduced significantly more error into the system than the dynamic measurements even though, in theory, the static measurement errors should be smaller than the dynamic. In several cases, the magnitude of the errors varied widely for the static measurements. Upon further investigation, researchers found the larger errors to be a consequence of hardware alignment issues, frame location and measurement technique whereas the smaller errors were dependent on the number of measurement points. This paper details and quantifies the individual and cumulative errors of the docking system and describes methods for reducing the overall measurement error. The overall quality of the dynamic docking tests for flight hardware verification was improved by implementing these error reductions.

Winnitoy, Susan↗

Measuring Shock Stage of ltokawa Regolith Grains by Electron Back-Scattered Diffraction and Synchrotron X-Ray Diffraction

We have been analyzing Itokawa samples in order to definitively establish the degree of shock experienced by the regolith of asteroid Itokawa, and to devise a bridge between shock determinations by standard light optical petrography, crystal structures as determined by electron and X-ray diffraction techniques. We are making measurements of olivine crystal structures and using these to elucidate critical regolith impact processes. We use electron back-scattered diffraction (EBSD) and synchrotron X-ray diffraction (SXRD). We are comparing the Itokawa samples to L and LL chondrite meteorites chosen to span the shock scale experienced by Itokawa, specifically Chainpur (LL3.4, Shock Stage 1), Semarkona (LL3.00, S2), Kilabo (LL6, S3), NWA100 (L6, S4) and Chelyabinsk (LL5, S4). In SXRD we measure the line broadening of olivine reflections as a measure of shock stage. In this presentation we concentrate on the EBSD work. We employed JSC's Supra 55 variable pressure FEG-SEM and Bruker EBSD system. We are not seeking actual strain values, but rather indirect strain-related measurements such as extent of intra-grain lattice rotation, and determining whether shock state "standards" (meteorite samples of accepted shock state, and appropriate small grain size) show strain measurements that may be statistically differentiated, using a sampling of particles (number and size range) typical of asteroid regoliths. Using our system we determined that a column pressure of 9 Pa and no C-coating on the sample was optimal. We varied camera exposure time and gain to optimize mapping performance, concluding that 320x240 pattern pixilation, frame averaging of 3, 15 kV, and low extractor voltage yielded an acceptable balance of hit rate (>90%), speed (11 fps) and map quality using an exposure time of 30 ms (gain 650). We found that there was no strong effect of step size on Grain Orientation Spread (GOS) and Grain Reference Orientation Deviation angle (GROD-a) distribution; there was some effect on grain average Kernel Average Misorientation (KAM) (reduced with smaller step size for the same grain), as expected. We monitored GOS, Maximum Orientation Spread (MOS) and GROD-a differences between whole olivine grains and sub-sampled areas, and found that there were significant differences between the whole grain dataset and subsets, as well as between subsets, likely due to sampling-related "noise". Also, in general (and logically) whole grains exhibit greater degrees of cumulative lattice rotation. Sampling size affects the apparent strain character of the grain, at least as measured by GOS, MOS and GROD-a. There were differences in the distribution frequencies of GOS and MOS between shock stages, and in plots of MOS and GOS vs. grain diameter. These results are generally consistent with those reported this year. However, it is unknown whether the differences between samples of different shock states exceeds the clustering of these values to the extent that shock stage determinations can still be made with confidence. We are investigating this by examination of meteorites with higher shock stage 4 to 5. Our research will improve our understanding of how small, primitive solar system bodies formed and evolved, and improve understanding of the processes that determine the history and future of habitability of environments on other solar system bodies. The results will directly enrich the ongoing asteroid and comet exploration missions by NASA and JAXA, and broaden our understanding of the origin and evolution of small bodies in the early solar system, and elucidate the nature of asteroid and comet regolith.

Zolensky, Michael↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Flight Mechanics Modeling and Simulation of the Earth Entry System

Introduction: The Mars Sample Return (MSR) Campaign being planned by NASA and ESA has the ambitious goal to return Mars samples back to Earth. This international collaboration had developed a concept of operations that included a ESA-designed Earth Return Orbiter (ERO) and NASA-designed Capture, Containment, and Return System (CCRS). The Earth Entry System (EES), consisting of a protective aeroshell that houses the samples as well as sample containment vessels, would conduct entry, descent, and landing (EDL) on a direct Earth trajectory. The EES would enter on a spin-stabilized ballistic trajectory with the goal to passively achieve aerodynamic stability throughout all regions of flight. The EDL sequence would end with the EES impacting the soft playa soil of the Utah Test and Training Range (UTTR). As of the submission of this abstract, the MSR campaign is undergoing a re-architecture leading to a pause in EES development. However, the novel approaches developed in flight mechanics modeling and simulation can significantly benefit the greater IPPW community in the development of Earth return vehicles. This paper will present the latest state of EES flight mechanics modeling and simulation. The paper will highlight the simulation architecture developed and key lessons learned from understanding of EDL trajectory sensitivities. Modeling and Simulation: Figure 1 provides a high-level concept of operations for the approach, entry, descent, and landing (AEDL) phase of the CCRS-portion of MSR. The objective of EES flight mechanics is to model and simulate the EES trajectory from ERO separation to ground impact at UTTR. A variety of flight mechanics simulation models were utilized to model both exo-atmopsheric and atmospheric portions of flight. 42, a 6-DOF simulation developed at Goddard Space Flight Center, is utilized for propagating the attitude of EES during exo-atmospheric flight. 42 allows for a variety of spin eject mechanism scenarios to be simulated for analysis. 10 minutes prior to entry, the 42 states are handed off to the EDL sims. The prime EDL sim utilized by EES is the Program to Optimize Simulated Trajectories II (POST2), a 6-DOF sim developed at Langley Research Center, and the independent verification and validation EDL sim utilized is DSENDS, a 6-DOF sim developed at Jet Propulsion Laboratory. Figure 2 provides a visualization of the flight mechanics simulation model flow through various points in the AEDL phase. Due to the existence of a variety of sim models, the EES flight mechanics team developed processes for data hand-off. These processes included the development of a centralized coordinate frame document, utilization of a single, centralized simulation input document for all sims to reference, and hand-off files containing both the technical data to be ingested by other flight mechanics sims as well as annotations of modeling assumptions utilized to generate the data. Figure~\ref{fig:post2simarchitecture} provides an overview of the POST2 sim architecture wherein POST2 ingests numerous subsystem models and input files. The dispersed state file generated by MONTE provides the position/velocity state of the trajectory while the 42 Handoff file provides the attitude. The aerodynamics database, delivered by the EES aeroscience team, is utilized to simulate the aerodynamic forces and moments experienced during EDL. A custom atmosphere model, developed by EES atmosphere team, is utilized to simulate the anticipated atmosphere environment around the region of Earth through which the EES trajectory flys. These inputs and subsystem models can be varied depending on the AEDL flight mechanics scenario being simulated. Monte Carlo simulations are utilized to generate statistical AEDL performance metrics in the form of scorecards and violin plots. Furthermore, outputs from the POST2 simulation are utilized for follow-on analyses including aerothermal and landing performance. \section{Flight Mechanics Lessons Learned} Though the EES flight mechanics team uncovered a variety of lessons learned through the analysis conducted to support CCRS through preliminary design review, this paper will highlight the most important lessons. A key AEDL performance goal is to ensure the landing footprint of EES remains on the UTTR south range. A common modeling strategy used in EDL analysis is One-Variable-At-a-Time (OVAT). OVAT analysis provides insight into the key drivers that affect AEDL performance metrics. Figure 3 shows the landing ellipses for single dispersion sources as compared to the baseline aggregate of all dispersions. The figure shows that atmosphere winds alone dominate the size of the footprint ellipse (note: EES does not use a parachute unlike previous Earth-return missions and is in wind-driven free fall for ~5min). The significance of the wind led the EES flight mechanics team to pursue the development of a Custom Atmosphere Model [4], in lieu of EarthGRAM [1], built on actual radiosonde wind measurements around the UTTR-region. This decision was driven by the realism in the generated footprint ellipses and lessons-learned from Stardust [5]. These findings will be invaluable for future Earth-return missions in providing an early understanding of the key drivers affecting footprint size and modeling considerations for which to account. Another lesson learned is tied to the AEDL performance goal of achieving passive stability throughout all regions of flight. It is well understood that blunt-body aeroshells are less stable as they transition from supersonic to subsonic. Eliminating a backshell does help improvestability; however, other phenomena such as roll-induced instability during terminal descent can still arise. The EES flight mechanics team developed stability metrics as tools to better understand the causes of and better predict the onset of dynamic instability. These tools were built upon analytical models developed by Jaffe [3] and Murphy [2]. The tools were shown to both be very accurate in correlation with actual unstable cases and useful in developing stability margin policies based on the vehicle design and simulation considerations (e.g. sphere-cone angle change, mass change, wind turbulence). These tools allowed for the current EES design to demonstrate the ability to achieve passive stability and can be an invaluable tool for consideration in the design of parachute-less Earth-return vehicles.

Rohan Deshmukh↗

Diffusion in Melts and Magmas

Diffusion results from random motion of particles and entities. Diffusion in melts and magmas is due to thermally excited random motion of atoms, ions, and clusters, and plays a critical role in magmatic and volcanic processes. In melts and magmas, diffusion is one of the two mechanisms of mass transfer; the other being bulk flow (referred to as convection or advection). When both are present, diffusion refers to the dispersive motion relative to the mean bulk flow in a given reference frame (Richter et al. 1998). Diffusion plays critical roles in controlling magma mixing (Watson 1982; Koyaguchi 1985, 1989; Lesher 1994; Huber et al. 2009; Guo and Zhang 2020), mineral growth and dissolution rates in magmas (e.g., Watson 1982; Harrison and Watson 1983; Zhang et al. 1989; Newcombe et al. 2014; Macris et al. 2018), bubble growth and dissolution rate in magmas (Sparks 1978; Proussevitch and Sahagian 1998; Liu and Zhang 2000; Zhang 2013), and elemental and isotope fractionation during mineral 2 growth and dissolution (Jambon 1980; Richter et al. 1999, 2003; Watson and Muller 2009; Chopra et al. 2012; Watkins et al. 2014, 2017; Holycross et al. 2016, 2018). As a result, diffusion also plays an essential role in explosive volcanic eruptions and magma crystallization. Furthermore, diffusion has important applications in geospeedometry (Lasaga 1983, 1998; Zhang 1994, 2008; Trail et al. 2016; Zhang and Xu 2016). Experimental investigation of diffusion in geologically relevant silicate melts began to flourish in the 1970’s when micro-analytical measurements of diffusion profiles became available. In addition to the vast number of papers published since then, numerous books and reviews are available for diffusion in silicate melts. Hofmann et al. (1974) edited a book titled “Geochemical Transport and Kinetics” published by Carnegie Institution of Washington. This was the first landmark book summarizing the field. Lasaga and Kirkpatrick (1981) edited a book “Kinetics of Geochemical Processes” as volume 8 of the Reviews in Mineralogy (later becoming Reviews in Mineralogy and Geochemistry) series. Zhang and Cherniak (2010) edited “Diffusion in Minerals and Melts” as volume 72 of Reviews of Mineralogy and Geochemistry series, in which one chapter focused on diffusion theory, five chapters on diffusion in silicate melts (Behrens 2010; Lesher 2010; Liang 2010; Zhang and Ni 2010; Zhang et al. 2010), and other chapters were on experimental, analytical, and computational methods, and diffusion in minerals. Several textbooks covered the principles and applications of diffusion theories (Kirkaldy and Young 1987; Shewmon 1989; Cussler 1997; Lasaga 1998; Zhang 2008; Vrentas and Vrentas 2016), and two classic books covered the mathematics of diffusion (Carslaw and Jaeger 1959; Crank 1975). In preparing for this review chapter, we thought carefully about what to cover for this vast field, and decided to briefly go through the fundamentals of diffusion (more complete review can be found in Chakraborty 1995; Zhang 2008, 2010) and solutions to often-encountered 3 diffusion problems, and then focus on post-2010 diffusion studies on silicate melts and magmas. Here, melts refer to (mostly natural) silicate liquid, and magmas refer to crystal-bearing and/or bubble-bearing melts in which the continuous phase is the melt. There is a large body of work on diffusion in glasses, especially in the materials science literature, which is not covered in this review.

Youxue Zhang↗