Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy and control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energy in Modular (EMOD) Buildings Method: A Guide to Energy-Efficient Design for Industrialized Construction of Modular Buildings

Industrialized construction has immense potential to address the growing need globally to build and upgrade the building stock to be affordable, energy-efficient, and resilient. It can also help achieve the United States' goal of a 50% reduction in U.S. greenhouse gas (GHG) emissions by 2030. Despite this potential, and the ever-increasing push for electrification and decarbonization of households in the United States, industrialized construction has not yet been leveraged specifically to help address these challenges and accelerate the pathway to meet these goals. The National Renewable Energy Laboratory (NREL) aims to claim this missed opportunity by focusing on delivering affordable, grid-efficient net-zero energy (NZE) modular buildings for underserved communities to ensure an equitable transition to the future of clean energy, accelerate decarbonization of the built environment, and support the development of a high-productivity construction and energy efficiency workforce. The Energy in Modular (EMOD) method is our approach to designing, producing, and delivering affordable, net-zero energy, low-carbon, and healthier buildings at scale. The following energy efficiency strategies are part of the scope of this guide: envelope thermal control, envelope infiltration control, mechanical, electrical, and plumbing systems, smart controls, and solar plus storage. We draw synergies between design for manufacturing and assembly, process optimization, retrofit technologies, and digitization. Our goal is to influence the improvement and production of buildings to increase performance, enhance energy efficiency, and reduce GHG emissions. This guide documents the research and development efforts initiated by a set of design objectives to "modularize" a set of energy efficiency and low-carbon strategies into a housing unit while preserving and enhancing energy efficiency benefits and decarbonization pathways. This guide is intended to serve as a framework for housing developers, housing agencies, architects, energy experts, and process engineers or factory operator personnel who are critical to today's modular builder teams. This guide focuses on specific energy efficiency strategies, decarbonization pathways, and associated processes as part of NREL's research efforts. Stakeholders may substitute other means, methods, and technologies for the ones evaluated in this study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model predictive control for active insulation in building envelopes

Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings - Part 1

We are pleased to present starting with this volume of ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC), a series of peer-reviewed papers related to some of ongoing research projects and applications of Grid-interactive Efficient Buildings (GEBs). As part of a new program initiated by the Building Technology Office (BTO) with the US Department of Energy (DOE), GEBs are characterized as highly energy-efficient buildings that are equipped with smart technologies and distributed energy resources that can be dynamically controlled to meet grid needs and minimize electricity system costs, while meeting occupants’ comfort and productivity requirements. In simple terms,DOE defines GEBs as efficient, connected, smart, and flexible buildings. The GEB technologies touch on the main topical areas of JESBC aimed at fostering sustainable buildings and cities by providing results of evaluation studies and demonstration projects. Indeed, one of the main goals for JESBC is to disseminate solutions to enhance the built environment energy efficiencies, low carbon services, inter-connectivity services, resilient multi-services, and healthy and comfortable living spaces.

buildings↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Efficient and assured reinforcement learning-based building HVAC control with heterogeneous expert-guided training

Abstract Building heating, ventilation, and air conditioning (HVAC) systems account for nearly half of building energy consumption and $$20\%$$ of total energy consumption in the US. Their operation is also crucial for ensuring the physical and mental health of building occupants. Compared with traditional model-based HVAC control methods, the recent model-free deep reinforcement learning (DRL) based methods have shown good performance while do not require the development of detailed and costly physical models. However, these model-free DRL approaches often suffer from long training time to reach a good performance, which is a major obstacle for their practical deployment. In this work, we present a systematic approach to accelerate online reinforcement learning for HVAC control by taking full advantage of the knowledge from domain experts in various forms . Specifically, the algorithm stages include learning expert functions from existing abstract physical models and from historical data via offline reinforcement learning, integrating the expert functions with rule-based guidelines, conducting training guided by the integrated expert function and performing policy initialization from distilled expert function. Moreover, to ensure that the learned DRL-based HVAC controller can effectively keep room temperature within the comfortable range for occupants, we design a runtime shielding framework to reduce the temperature violation rate and incorporate the learned controller into it. Experimental results demonstrate up to 8.8 X speedup in DRL training from our approach over previous methods, with low temperature violation rate.

Xu, Shichao↗

Designing reinforcement learning algorithms for building HVAC control: From experimental observation to simulation comparisons

Advanced supervisory-level control with reinforcement learning (RL) is regarded as a promising solution for HVAC systems to minimize energy consumption while maintaining thermal comfort and indoor air quality. However, most RL applications were conducted in the simulation environment rather than real-world HVAC systems. This paper developed a value-based RL controller termed Deep Q-Network (DQN) for a typical central HVAC system and evaluated its performance in a building test facility. By comparing DQN with a rule-based controller, the study not only demonstrated the cases where DQN could properly maintain indoor comfort but also discussed possible reasons why DQN failed in some other situations. Recognizing the limitations of value-based RL algorithms from the experimental tests, a simulation study was conducted to compare DQN with an alternative RL approach, an actor–critic algorithm termed Deep Deterministic Policy Gradient (DDPG). In scenarios with a relatively large action space, DDPG outperformed DQN by requiring fewer computational resources and achieving better thermal comfort, lower energy consumption, and more stable control actions. The findings suggest that the ability of DDPG to handle continuous control variables more effectively allows for faster convergence in training and more precise control in practice, which enhances the overall efficiency and reliability of the HVAC system.

Guo, Fangzhou↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A General Purpose Real-Time Optimization Strategy Applied to Minimizing Simultaneous Heating and Cooling in Buildings

Supervisory control strategies in heating, ventilating, and air-conditioning (HVAC) systems hold the potential for significant energy savings but they are difficult to set up and often depend on unreliable sensor measurements. In this paper, we propose a sensor-free approach to minimizing the energy penalties due to simultaneous heating and cooling in variable-air-volume (VAV) systems with reheat. A general-purpose real-time optimizer is described that is easy to set-up and integrate with existing control logic. A cost function is derived that quantifies the simultaneous heating and cooling penalty that does not require any sensor measurements. The optimizer then minimizes this cost function by automatically adjusting the supply temperature setpoint in the air-handling unit. The paper describes the approach and shows results from application from field trials on a 27-zone building.

Salsbury, Timothy↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Lighting Technology Energy Solutions (LiTES) (Final Technical Report)

The Lighting Technologies Energy Solutions (LiTES) Program Final Technical Report is a collaborative effort between NextEnergy, Consumers Energy, DTE Energy (DTE) and the Detroit Joint Apprentice Training Center (DJATC) to evaluate customer and contractor experiences deploying advanced/networked lighting controls systems (ALC/NLC). The LiTES Program, funded by the US Department of Energy (DOE), sought to reduce energy use in small and medium commercial buildings (SMCB) by accelerating the adoption of ALC/NLC through contractor training and technology deployment. Leveraging recommendations already outlined by the Design Lights Consortium Commercial Advanced Lighting Controls (DLC CALC) project, NextEnergy led an effort to train contractors, evaluate the experience of ALC/NLC demonstration projects, identify opportunities to reduce market barriers, and accelerate the increased adoption of ALC/NLC technologies within SMCB. The LiTES Program defined SMCB as commercial buildings under 100,000 square feet. The LiTES Program efforts also included evaluating current ALC/NLC utility incentives, piloting ALC/NLC incentives specific to SMCB, and identifying opportunities to better align utility incentives with current ALC/NLC technology to support accelerating the adoption of ALC/NLC in SMCB. This report shares the survey results and M&V data findings, including energy savings, market barriers, experience of installations, impact of incentives/financing programs and provides recommendations for the increased deployment of ALC/NLC systems in small and medium commercial buildings. Utility survey results, incentive alternatives and recommendations, including a cost benefit analysis outlining energy and economic impacts of the provided ALC/NLC incentives on SMCB projects are also provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗