Large area focusing collector for the observation of cosmic X rays.

A large area focusing X-ray collector constructed for a sounding rocket is described. The instrument consists of nested reflecting plates that are curved slightly in one dimension to form a set of parabolas with a common focus. An array of plates such as the one in the sounding rocket focuses a parallel beam of X-rays to a line. The reflecting surfaces are commercial float glass with an evaporated metallic coating such as gold or nickel. With a gold coating, the effective area of the rocket collector is about 250 sq cm for 0.3 keV X rays and about 150 sq cm at 1.2 keV. Its angular resolution is a few arc minutes and field of view is about plus or minus .75 deg (full width at half maximum). The collector performed successfully during a sounding rocket flight.

Gorenstein, P.↗

Solar collector performance evaluated outdoors at NASA-Lewis Research Center

The study of solar reflector performance reported is related to a project in which solar collectors are to be provided for the solar heating and cooling system of an office building at NASA's Langley Research Center. The solar collector makes use of a liquid consisting of 50% ethylene glycol and 50% water. A conventional air-liquid heat exchanger is employed. Collector performance and solar insolation data are recorded along with air temperature, wind speed and direction, and relative humidity.

Vernon, R. W.↗

Faceted solar energy collectors

Two concepts enhance efficiency and flexibility of solar collectors: faceting collector surface and adding coloring agent to working fluid. Collector can be placed on existing structures and oriented to take advantage of position of sun. By adding coloring agent to working fluid, total absorbance can be increased and altered if required.

Segna, D. R.↗

Tower-supported solar-energy collector

Multiple-collector tower system supports three receiver/concentrators that absorb solar energy reflected from surrounding field of heliostats. System overcomes disadvantages of tower-supported collectors. Booms can be lowered during heavy winds to protect arms and collectors.

Selcuk, M. K.↗

Experimental evaluation of a stationary spherical reflector tracking absorber solar energy collector

This article presents experimental data for the thermal performance of a stationary, spherical-reflector, tracking-absorber solar energy collector (SRTA). The principle of operation and details of thermal performance of such an SRTA have previously been described. These experimental results were compared with the predictions of a thermal analysis previously published. Experimental results were compared with the prediction of Kreider's computer model. Within the range of the temperature of the experiments, the predicted performance of the unit agreed well with experimental data collected under clear sky conditions. In addition, the extrapolation of the efficiency to higher temperature is shown so that the potential of an SRTA solar collector as a means of providing high temperature steam to operate an electric power facility or for process heat can be evaluated. As a result of the tests conducted by NASA, and an economic analysis not yet publicly available, it appears that the SRTA solar collector concept will be economically viable in competition with any other existing solar system in providing electrical energy.

Steward, W. G.↗

Fixed flat plate collector with a reversible vee-trough concentrator

An asymmetrical-reversible vee-trough concentrator for use both with nonevacuated and evacuated receivers is proposed in order to improve the performance of a fixed flat plate collector. The device is capable of maintaining a year-round concentration factor of about 2 while eliminating the complications of the tilt adjustments of the collector box assembly. Efficiency improvements and cost reductions for temperatures of about 100 and 200 C are offered for the nonvacuum and vacuum tube versions, respectively. A major advantage of the vee-trough is the enhancement of the incident flux, thus extending the collection period. The vacuum collector is suitable for supplying heat to solar Rankine systems, while the nonvacuum version can be used for air conditioning purposes via an absorption air conditioner.

Selcuk, M. K.↗

MSFC hot air collectors. Phase 1: Test report

A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

Losey, R.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor thermal performance evaluation of the SEPCO air collector

The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.

Source record↗

Indoor test for thermal performance evaluation on the Sunworks (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Indoor test for thermal performance evaluation on life sciences engineering (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a life sciences double-glazed air solar collector under simulated conditions is discussed. These tests were made using the Marshall Space Flight Center's solar simulator. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Performance of a thermionic converter module utilizing emitter and collector heat pipes

A thermionic converter module simulating a configuration for an out-of-core thermionic nuclear reactor was designed, fabricated, and tested. The module consists of three cylindrical thermionic converters. The tungsten emitter of the converter is heated by a tungsten, lithium heat pipe. The emitter heat pipes are immersed in a furnace, insulated by MULTI-FOIL thermal insulation, and heated by tungsten radiation filaments. The performance of each thermionic converter was characterized before assembly into the module. Dynamic voltage, current curves were taken using a 60 Hz sweep and computerized data acquisition over a range of emitter, collector, and cesium-reservoir temperatures. An output power of 215 W was observed at an emitter temperature of 1750 K and a collector temperature of 855 K for a two diode module. With a three diode module, an output power of 270 W was observed at an average emitter temperature of 1800 K and a Collector temperature of 875 K.

Kroeger, E. W.↗

Design and installation package for the Sunmat Flat Plate solar collector

The information used in evaluating the design of a liquid flat plate solar collector is reported. Included in this package are subsystem performance specification, installation, operation and maintenance manuals, collector sizing guides, and detailed drawings of the single-glazed collector.

Source record↗

Development of flat-plate solar collectors for the heating and cooling of buildings: Executive summary

An efficient, low cost, flat-plate solar collector was developed. Computer aided mathematical models of the heat process in the collector were used in defining absorber panel configuration; determining insulation thickness; and in selecting the number, spacing, and material of the covers. Prototypes were built and performance tested. Data from simulated operation of the collector are compared with predicted loads from a number of locations to determine the degree of solar utilization.

Source record↗