Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMSOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Numerical and Analytical Modeling of the Effect of Cracks on the Self-Inductance of a COTS YJ-41003-TC Toroid

COTS inductors and transformers often contain partial cracks whose effect on inductance, a key performance parameter, have not been carefully studied. In this report, the effects of both partial and complete cracks on the self-inductance of a 100 turn square cross section COTS YJ-41003-TC toroid comprised of J Material was comprehensively investigated using both analytically derived closed form expressions and 3D computational techniques employing commercial codes. Both partial (half-penny) and complete (air gap) cracks of 10 and 25 μm were investigated. The crack is defined as the physical distance between two faces of the toroid's magnetic core, such that the surface normal of either face is along the Φ-direction, in alignment with the B-field. For the purposes of validation, two different approaches were incorporated for both the analytical and numerical models. The two analytical methods are comprised of a first principles approach based on the physics of electromagnetics, as well as linear circuit theory. The former directly utilizes the integral form of Maxwell's equations while the latter exploits the interchangeable relationship between electric and magnetic circuits. Validation within the computational scheme is realized through a code-to-code comparison between commercial solvers, COMSOL Multiphysics and CST, with the former employing the Finite Element Method (FEM) and the latter the Finite Difference Time Domain (FDTD) technique. Sound agreement between all four methods (ie., two analytical and two numerical) is observed, with results indicating that only a perturbation in self-inductance occurs for the half-penny cracks, while a substantial reduction takes place for the case of complete cracks. It is important to note that even though a static μ r is applied, representing the linear region of the BH curve (based on manufacturer specifications), the complete crack results still place a lower conservative bound on the inductance. This follows from the fact that even in the case of a half-penny crack, if the magnetic core portion of the crack approaches saturation, the crack begins to behave like an air gap, or complete crack. When an air gap is introduced into a magnetic core, a substantial reduction in inductance can occur due to the significant difference in permeabilities between the two mediums (ie., μ core >> μ air ). The once intact bulk magnetic core of the toroid essentially begins to behave like an air core.

36 MATERIALS SCIENCE↗

Fiber optic system for direct detection of CO 2 leakage in carbon storage wells (Abbreviated Final Report)

The feasibility study focused on the development of new fiber for distributed chemical sensing that will allow direct detection of CO2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), which can provide early warning for an incoming well failure and potential CO2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously. The methodology would overcome current roadblocks to using fiber optics for CO2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure. We were able to assess commercially available IR/Raman hollow core fiber and demonstrated detection of CO2 through them in our controlled environment setups at various pressure conditions. We have also established the ability of drilling precisely with fs-lases side holes to enable penetration of CO2 into the hollow core fiber and reduce diffusion rates. Open joint collars were also explored with double functionality: to obtain splice to solid core fiber critical for field deployment and create gas ingress locations. Both diffusion-only and pressurized fiber system have been constructed following COMSOL based semi-hybrid optical /fluidodynamics models. FBGs have been identified and procured and characterized. Along the work we leveraged internal modeling/design, photonics/laser characterization, optical fiber fabrication, and AM lab capabilities to design, develop and test in-house components or assemblies. Our results indicate the potential of HoF for CO2 downhole direct detection.

25 ENERGY STORAGE↗

Computational Fluid Dynamics Modeling to Simulate a Combined Reforming Process for Syngas and Hydrogen Production

An Oxygen Transport Membrane (OTM) combined reforming technology for producing syngas and hydrogen integrates the advantages of multiple processes—steam methane reforming (SMR), autothermal reforming (ATR), an air separation unit (ASU)—into a single integrated technology. The OTM consists of a primary reforming tube, in which desulfurized natural gas is partially reformed by steam at high pressure in the presence of a metal catalyst. This process is followed in series by a ceramic OTM with a secondary reformer, in which residual methane reforms and O 2 - ions react with a portion of the CO and H 2 fuel to provide the heat to support both primary and secondary reforming. Although the OTM combined reformer technology for syngas and H 2 production has been substantially developed in the last decade, several challenges that affect the overall production efficiency and reliability are yet to be fully understood, addressed, and resolved. Therefore, developing Computational Fluid Dynamics (CFD) models that incorporate fluid dynamics, mass transport, kinetics, heat transport, and structural mechanics is critical to understanding and minimizing the probability of tube failures during the startup and operation. In this report, an exhaustive literature review was performed to survey the current state of technology for producing syngas and H 2 using either conventional or renewable energy sources. The feedstocks reviewed include natural gas and coal for the conventional technologies, whereas biomass, solar, wind, and nuclear energy for the renewable technologies. The existing industry-grade COMSOL multiphysics models of OTM were upgraded for the latest software release. In addition, they were improved to help achieve grid and solver independence and were successfully ported on the ORNL high-performance computing clusters to speed up their run times. A 42% reduction in the simulation run time was achieved. A new higher-fidelity CFD model of an OTM tube was developed in the StarCCM+ simulation platform. This new model was designed to simulate various physics using first principles, e.g., turbulent flow, heat transfer, and chemical reactions while avoiding unnecessary simplifications. The resulting predictions were qualitatively assessed and provided useful insights into the multiphysics complexity of an OTM tube.

08 HYDROGEN↗

University of Missouri Research Reactor (MURR) Design Demonstration Element End Fitting Structural Rigidity Analysis

The primary objective of this work is to assess the extent to which the stiffness (measured by means of maximum displacement) of the end fittings in the DDE contributes to the stiffness of the entire element, and how it compares to the equivalent stiffness of the end fittings in the LEU element. Structural analysis of both the LEU element and the DDE were performed using COMSOL 5.3a finite element software. Supporting combs are used on the leading and trailing edges of fuel plates for both the LEU element and the DDE. Therefore, simulations with and without combs are performed as two bounding boundary conditions on the leading edge of the fuel plates. Three types of loads are analyzed in this work: the hydraulic load due to the channel flow disparity-induced pressure differential, the thermal load due to the thermal expansion of the fuel plates, and a point load equal in magnitude to the LEU element’s weight.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Vapor Transport Deposition of Metal-halide Perovskite Thin Films for Photovoltaic and Optoelectronic Devices

Over the past decade, metal halide perovskites (MHPs) have emerged as a promising materials platform for high-efficiency solar cells and low-cost optoelectronics. However, there are challenges that frustrate the large-scale manufacturing of MHP devices, including difficulty in controlling film composition, interface formation and their device instability under ambient conditions. Vapor processing offers an attractive path to manufacturability, while also opening the door to new opportunities in device design that could favorably impact ultrahigh efficiency tandem solar cells or overall stability. Emphasis here is on the use of an alternate processing methodology, vapor transport deposition (VTD), to deposit the MHP layer. In experimental work, we found that our deposition system had significant run-to-run variations in film thickness and composition. To understand and resolve these issues, we use COMSOL Multiphysics software to model the precursor deposition rate numerically, trying to guide the broad range of parameters in the system. The result can be matched with experimental data and provides insight into system hydrodynamics and molar transport effects. Finally, we show that chamber pressure is a key factor to scale up the VTD technique.

Hsu, Wan-Ju↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Size and Density Measurement

This project has developed a miniature gravity settling classifier (flow cell) and flow system that separates slurry particles by settling rate into six different Cuts. The settling rates for particles in each Cut were determined from COMSOL computational fluid dynamics (CFD) modeling of the flow in the flow cell together with particle tracking for particles of differing settling rates. For particles collected in each Cut, the particle concentration and size distribution were measured. The effective particle densities from each Cut are calculated from their respective CFD modeled settling rates using a relationship between the unhindered settling rate, particle size distribution (PSD), and effective density. The particle size and density distribution (PSDD) of the slurry sample is then calculated by combining the size and density distributions determined for the particles collected in each of the settling rate Cuts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning Classification of Molten Salt Heat Exchanger Channel Plugging using Synthetic Data

This report addresses the requirements of Milestone M3.4 AI capability to identify and predict maintenance events. Development of digital twins (DT) for molten salt reactor (MSR) components is crucial for reducing operating and maintenance costs (O&M) and ensuring commercial viability of these reactors. Our focus is on development of DT for MSR primary system heat exchanger (HX), a critical component, the fault in which can reduce operating efficiency and force reactor shutdown. We are investigating the feasibility of a conceptual DT of HX consisting of internal distributed temperature sensing with fiber optics and machine learning (ML) algorithms to detect and localize faults. To determine the optimal approach to detection and localization of channel plugging, we benchmark seven different ML models: Logistic Regression, K-Nearest Neighbors (KNN), Gaussian Naïve Bayes, Support Vector Machines (SVM), Decision Tree Classifier, Random Forest Tree Classifier, and Feed-Forward Neural Network. ML algorithms are benchmarked using synthetic HX plugging data generated with computational fluid dynamics COMSOL software, with added brown noise to represent experimental noise. We show that the best performance is obtained with the Decision Tree classifier.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Tritium Retention in LiAlO2 Pellets via Engineered Glazes: Tritium Science Project

This project investigated the impact of adding a thin (10 – 50 µm) layer of amorphous glaze to the surface of a TPBAR pellet on its retention of helium, hydrogen (as a surrogate for tritium), and water (as a surrogate for tritiated water). The hypothesis was that the glaze would significantly reduce permeation of hydrogen species with a lesser impact on hindering helium permeation. A non-crystallizing soda-lime-silicate glass, known as SCN-1, was selected for this proof-of-concept study. It was found that continuous glaze layers of the desired thickness could be applied to the pellets with two or more dip coats, depending on the targeted thickness. At 330°C, the glaze was found to have a permeability that was lower than that of the pellet by a factor of ~10 6 , implying that a thin 10 – 50 µm layer can significantly increase pellet retention of hydrogen. Meanwhile, the permeation rate of helium through the glaze was found to be ~20 times higher than that of hydrogen or water. An unanticipated outcome of the study was that unglazed pellets were measured to have hydrogen diffusivities that are a factor of ~105 greater than the diffusivity value used in the TPBAR COMSOL model to achieve observed tritium retention rates. When the higher measured diffusivity was substituted into the model and the model was run with all tritium species in the pellet in the form of T 2 O at a partial pressure of 20 Pa in equilibrium with LiOT, the resulting retention was 50% after 500 days.

36 MATERIALS SCIENCE↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Design, Modeling, and Testing of a Novel Inductor for Electric Vehicles: Iron Nitride Soft Magnetic Composites

New technology for electric vehicles (EVs) must meet the requirements of higher energy usage, lower costs, and more sustainable source materials. One promising material for EV power system components is iron nitride (IN) soft magnetic composites (SMCs) because of their competitive magnetic properties and high abundance of the source materials. As part of an ongoing program at Sandia National Laboratories, this project focused on using computer modeling to optimize the prototyping process for an iron nitride SMC toroidal inductor to reach a target inductance of 600 μH. Four inductors with different combinations of wiring (26 AWG and 20 AWG) and vol% loading of iron nitride (65 vol% and 50 vol%) were fabricated at Cal Poly and characterized using an LCR meter. These inductors were also modeled using COMSOL Multiphysics™ with the Magnetic Fields module. The inductance data from the experiment and the model show that the 65 vol% IN prototypes and models agree with about 8% difference, while the 50 vol% IN samples show about a 9% difference between the prototype and the model. These results suggest that the model can predict inductance with both accuracy and precision with low confidence for the given sample size of four. An additional parameter of AC resistance is studied but the AC resistance results from the inductors and from the model generally do not agree closely, suggesting that the current model used in the project does not fully capture the mechanisms behind AC resistance of the inductor. With the focus of the project on inductance, the percent difference results of less than 9% across the four inductors that were tested increases confidence in the model’s predictive capabilities for inductance only. Using the inductance results from both the model and experiment, the final suggested inductor design is a 65 vol% core with 150 windings of 20 AWG wire that is 8 cm across and 1.5 cm tall to reach the inductance goal of 600 μH based on analysis using the optimized COMSOLTM model.

33 ADVANCED PROPULSION SYSTEMS↗

Low Temperature CO2 Capture from an NGCC Flue Gas Using a Magnetically Stabilized, Inductively Heated Fluidized Bed Reactor

The lab sorbent testing finalized the sorbent composition and operating conditions for the integrated unit. The bench unit design included COMSOL simulation to finalize the coil design and select initial operating conditions of the power supply system. Fluidized bed testing with the induction heating verified that a heating efficiency of up to 90% can be achieved. The integrated bench unit operations provided valuable data confirming the feasibility of using induction heating for the desorption of CO2. Major challenge observed was the limited working capacity of the sorbent, requiring additional development in future projects. In addition, a large-scale reactor demonstration is required to mitigate the risk of uniform temperature distribution and heating efficiency over a large cross-sectional area when using induction heating.

Tong, Andrew↗

Evaluating large scale aqueous organic redox flow battery performance with a hybrid numerical and machine learning framework

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low-capacity degradation in 10 cm$^2$ cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier to commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm$^2$ DHP-based AORFB by combining a physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. Such combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reduction of Methane Leaks through Corrosion Mitigation Pre-treatments for Pipelines with Field Applied Coatings

Corrosion of buried, coated steel pipelines transporting natural gas is a significant source of methane emissions, from pipeline venting required for maintenance and repairs and from pipeline leaks and incidents. Corrosion of steel under field applied coatings is an important safety concern for the pipeline industry. This project investigates the application of a field applied alloy over girth welds to mitigate external corrosion of buried coated steel pipelines. Various metallic coating options were considered, which were required to meet several criteria: (1) it must resist corrosion under open-circuit or mild cathodic protection conditions, (2) it must protect the substrate steel, and (3) it must not negatively affect the adhesion of the field coating. Finite element models and lab testing were performed of alloy coating compositions to identify promising alloy types underneath disbonded coatings. Polarization curves of coating alloys were generated to provide the boundary conditions for the COMSOL model to compute potential and current distributions around coated areas. Sacrificial and corrosion-resistant metal alloy coatings were evaluated and optimized using corrosion modeling and laboratory electrochemical testing, where aluminum alloy 5356 (5% Mg) and steel alloy B9 (9% Cr) were selected. Corrosion test coupons were designed and fabricated using thermal spray aluminum 5356 and welded B9 steel overlays on API 5L grade X42 line pipe steel. The corrosion test coupons, with simulated pipe coating damage, were tested in a laboratory soil box and a field pipeline site in Texas for 3-months. Corrosion test coupons were then tested for 6-months at field pipeline sites in Texas and Tennessee to quantify corrosion rates and performance of the aluminum and steel alloys under polyethylene tape and 2-part epoxy coatings, various coating holidays, and with and without cathodic protection.

03 NATURAL GAS↗