Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCRETES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Influence of freeze-thaw cycles on capillary absorption and chloride penetration into concrete

Combined mechanical and environmental actions reduce service life of reinforced concrete structures more than each of the participating actions alone. In this contribution, the influence of freeze-thaw cycles on capillary water absorption and chloride penetration into ordinary concrete with two different water-cement ratios and air-entrained concrete was investigated. Water profiles in concrete were quantified by neutron radiography. Capillary water absorption and chloride penetration are both slowed down considerably by air entrainment. Chloride ions dissolved in water are filtered out of the penetrating salt solution and remain concentrated near the surface. Capillary water absorption and chloride penetration into ordinary concrete are accelerated considerably by frost damage. After exposure to freeze-thaw cycles a damage gradient from the surface to the center of the samples was observed. Transport mechanisms were studied in some detail and the data obtained can serve as a basis for more realistic prediction of service life of reinforced concrete structures under the influence of combined freeze-thaw cycles and chloride penetration.

36 MATERIALS SCIENCE↗

Effect of interfacial transition zone on the Young's modulus of carbon nanofiber reinforced cement concrete

Identifying the properties of the region where the cement paste meets the aggregate surface (interfacial transition zone, ITZ) is critical to understanding the strength and fracture behavior of carbon nanofiber (CNF) reinforced cement concrete. In this study, the finite element method is employed to investigate the effect of the ITZ on the Young's modulus of cement concrete made with CNF. The numerical models for cement concrete with and without CNF are constructed based on the digital image processing technique. To consider the interface effect, the concept of ''effective aggregate'' is put forward, namely, the Young's modulus and Poisson's ratio for each aggregate particle are replaced by an effective Young's modulus and effective Poisson's ratio, in which the effect of thickness and the Young's modulus of ITZ is taken into account in an averaged manner. Then, the quantitative nanomechanical mapping (based on atomic force microscopy) technique is adopted to measure the Young's modulus and thickness of ITZ with and without CNFs, which are further used as the input parameters in the numerical model. The numerical simulation results are verified by experimental testing, which indicates that the ITZ effect should be considered when implementing the numerical simulation. In addition, this analysis shows that compared with the plain cement concrete, CNFs can greatly enhance the mechanical properties of ITZ, which will in turn improve the Young's modulus of cement concrete significantly. Finally, the effect of thickness and Young's modulus of ITZ on the Young's modulus of CNF reinforced cement concrete is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Concrete material science: Past, present, and future innovations

Concrete is flying off, but it is simultaneously facing tremendous challenges in terms of environmental impact, financial needs, societal acceptance and image. Based on an historical approach of the science of concrete and reinforced concrete in particular, this paper calls for the exploration of radical changes in three key aspects of concrete use: reinforcement, binder content, and implementation methods. More precisely, it is suggested that, in parallel to the introduction of robotic fabrication methods, digital technologies may be key for the introduction several innovations like (i) rebar-free reinforcement using non-convex granular media; (ii) compression-optimized concrete structures, using topology optimization, architectural geometry, and 3D-printing or origami-patterned formworks; (iii) truly digital concrete through the coupling of massive data collection and deep learning.

36 MATERIALS SCIENCE↗

Meso-scale modelling of compressive fracture in concrete with irregularly shaped aggregates

This paper presents a meso-scale modelling framework to investigate the fracture process in concrete subjected to uniaxial and biaxial compression accounting for its mesostructural characteristics. 3D mesostructure of concrete consisting of coarse aggregates, mortar and interfacial transition zone between them was developed using an in-house code based on the Voronoi tessellation and splining method, which enables to generate the realistic-look aggregates with controllable structural features such as content, location, size and shape. Based on the generated 3D mesostructure, the concrete damage plasticity approach was employed to simulate the compressive fracture behaviour of concrete in terms of crack morphology and stress-strain response against the shape parameters of aggregate. Results indicate that the shape of aggregate has a negligible effect on compressive strength of concrete, which is highly associated with the random location and size distribution of aggregate. The aggregate irregularity has a significant influence on crack initiation and growth of concrete.

36 MATERIALS SCIENCE↗

Modelling the development of capillary pressure in freshly 3D-printed concrete elements

3D concrete printing is a promising technology recently developed to automate construction. Since no formwork is used in this technology to support and protect fresh concrete, there are two aspects which considerably accelerate the development of capillary pressure in 3D-printed concrete in comparison to conventionally placed concrete: i) high stiffness of 3D-printed needed to provide sufficient buildability, and ii) very early and fast evaporation of pore water. Accelerated development of capillary pressure may lead to severe plastic shrinkage cracking in 3D-printed elements and, hence, need to be mitigated. This investigation aims at providing a poromechanical model for capillary pressure development in 3D-printed elements. To simulate the development of capillary pressure and plastic shrinkage, environmental factors, material properties, and element geometry need to be considered as a whole. The model inputs – coefficient of permeability, static bulk modulus, air entry pressure and chemical shrinkage rate – were determined experimentally. The model was validated for two fine-grained concretes. Both 3D-printed materials yielded faster capillary pressure increase in comparison to cast concrete, while partial substitution of cement with silica fume further accelerated the capillary pressure development. Furthermore, due to the lower permeability of the mixture containing silica fume, the gradient of capillary pressure between 3D-printed layers increased, as did the gradient of plastic shrinkage.

36 MATERIALS SCIENCE↗

Recycling of PET bottles as fine aggregate in concrete

An attempt to substitute in concrete the 5% by weight of fine aggregate (natural sand) with an equal weight of PET aggregates manufactured from the waste un-washed PET bottles (WPET), is presented. The WPET particles possessed a granulometry similar to that of the substituted sand. Specimens with different cement content and water/cement ratio were manufactured. Rheological characterization on fresh concrete and mechanical tests at the ages of 28 and 365 days were performed on the WPET/concretes as well as on reference concretes containing only natural fine aggregate in order to investigate the influence of the substitution of WPET to the fine aggregate in concrete. It was found that the WPET concretes display similar workability characteristics, compressive strength and splitting tensile strength slightly lower that the reference concrete and a moderately higher ductility.

54 ENVIRONMENTAL SCIENCES↗

Effect of Interlayer Time-Lapse and Workability Retention on Printed Concrete Performance

The rapid advancement of additive manufacturing technologies for concrete construction requires further understanding of material performance and its relationship with print parameters such as interlayer time-lapse and workability retention during the print. Here this study addresses the effects of the time delay between consecutive extruded layers on the mechanical performance of printed concrete using a mix designed by Quikrete. A series of specimens were prepared with printing delays of 10, 15, 30, and 60 min. This work correlates the change in fracture properties, mechanical performance, and workability retention with the interlayer time-lapse between two consecutive concrete layers. Interlayer time-lapse is defined as the time difference in printing of two consequent layers of concrete. It affects individual properties differently based on the loading direction and test types, but it is consistent in terms of interlayer performance. The understanding of the effect of interlayer time-lapse on the fracture properties between two consecutive printed layers fills the knowledge gaps in printed concrete research. Therefore, this study can help researchers perform required optimization and safely estimate the performance of printed concrete.

3D printing↗

Preliminary study of neutron absorption by concrete with boron carbide addition

Concrete has become a conventional material in construction of nuclear reactor due to its properties like safety and low cost. Boron carbide was added as additives in the concrete construction as it has a good neutron absorption property. The sample preparation for concrete was produced with different weight percent of boron carbide powder content. The neutron absorption rate of these samples was determined by using a fast neutron source of Americium-241/Be (Am-Be 241) and detection with a portable backscattering neutron detector. Concrete with 20 wt % of boron carbide shows the lowest count of neutron transmitted and this indicates the most neutrons have been absorbed by the concrete. Higher boron carbide content may affect the concrete strength and other properties.

07 ISOTOPE AND RADIATION SOURCES↗

Nondestructive Damage Detection of Concrete With Alkali-Silica Reactions Using Coda Wave and Anomaly Detection

An anomaly detection model for early damage detection for concrete structures undergoing alkali-silica reaction (ASR) is presented. It is difficult to detect ASR initiation and early damage without a reference expansion measurement. Coda waves, or the multiply scattered portion of ultrasonic waves, have been found to be indicative of small changes in complex material such as concrete. The relationship between concrete damage and relative velocity change and decorrelation of coda waves has been studied, but a generalized model which detects when damage occurs in a concrete structure is still lacking. The presented method uses features extracted from coda waves to detect early damage in concrete structures. The model uses unsupervised learning and only requires data from undamaged structures for training. During the training process, the reconstruction error of the training data is minimized. When the data collected from damaged concrete structures is used as an input of the model, it returns high reconstruction errors that indicate the occurrence of damage in the structures. The performance of the model is validated using experimental studies and has been shown to generalize across two different ASR specimens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation of rates of tritium migration through porous concrete

In a nuclear facility when tritium leaks from a glovebox to room accidentally, an atmosphere detritiation system (ADS) starts operating, and HTO released is recovered by ADS. ADS starts when tritium activity in air becomes higher than its controlled level. Before ADS operates, the laboratory walls are the final enclosure facing tritium and are usually made of porous concrete coated with a hydrophobic paint. In the present study, previous data on the diffusivity and adsorption coefficient of concrete and paints are reviewed. Tritium penetrates and migrates into concrete by following 3 ways. First, gaseous HT or T{sub 2} easily penetrates into porous concrete. Its diffusivity is almost equal to that of H{sub 2}. When a gaseous molecule diffuses through pores with a smaller diameter than a mean free path, its migration rate is described by the Knudsen diffusion formula. The second mechanism is H{sub 2}O vapor diffusion in pores. Concrete holds a lot of structural water. Therefore, H{sub 2}O or HTO vapor can diffuse inside concrete pores along with adsorption-desorption and isotopic exchange with structural water, which is the third mechanism. Literature shows that the diffusivity of HTO through the epoxy-resin paint is determined as D(HTO)=1.0*10{sup -16} m{sup 2}/s. We have used this data to set a model and we have applied it to estimate residual tritium in laboratory walls. We have considered 2 accidental cases and a normal case: first, ADS starts operating 1 hour after 100 Ci HTO is released in the room, secondly, ADS starts 24 hours after 100 Ci HTO release and thirdly, when the walls are exposed to HTO for 10 years of normal operation. It appears that the immediate start up of ADS is indispensable for safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Nuclear Containment Vessel Modeling for Multi-Hazard Probabilistic Risk Assessment under Seismic Hazards and Concrete Degradation

The current practice for natural phenomena hazards (NPH) risk assessment of nuclear facilities is to compute the risk for each hazard independently and then compound the total risk as a combination of single hazard risks. This state of practice does not consider correlations between hazards and the cascading impacts to structures, systems, and components (SSCs), and could thus underestimate the NPH risk or overestimate the nuclear facility safety. Events such as the Fukushima Daiichi accident have highlighted the importance of multi-hazard risk considerations to nuclear power plants (NPPs) that quantify the cascading damage effects to SSCs in the risk models. Moreover, the current fleet of NPPs in the United States is aging; these NPPs are now expected to operate well beyond their initially planned design life. Aging-related deterioration can potentially decrease the capacity of critical structures such as containment vessels to withstand NPH. Such aging considerations may not be adequately accounted for by the current NPH risk assessment guidelines. This paper presents a preliminary modeling and simulation of a representative reinforced concrete containment vessel subjected to seismic mainshock and aftershock considering concrete degradation due to alkali silica reaction. The broader aim is to develop multi-hazard time-dependent fragility functions that could be subsequently used in the probabilistic risk assessment (PRA) model. The multi-hazard component comes into play due to the consideration of damage to the containment vessel under seismic loads and concrete degradation. Consideration of concrete degradation also brings into play the time-dependent nature of the containment vessel response. The response of the containment vessel under varying degrees of concrete degradation to seismic loads is investigated. The results presented are simulated using the Multi-hazard Analysis for STOchastic time-DOmaiN phenomena (MASTODON) software for seismic analysis and the Blackbear software for concrete degradation and damage modeling. Both software are open source and developed within the Multiphysics Object-Oriented Simulation Environment (MOOSE).

42 ENGINEERING↗

OECD MCCI project long-term 2-D molten core concrete interaction test design report, Rev. 0. September 30, 2002.

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following two technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of the first program objective, the Small-Scale Water Ingression and Crust Strength (SSWICS) test series has been initiated to provide fundamental information on the ability of water to ingress into cracks and fissures that form in the debris during quench, thereby augmenting the otherwise conduction-limited heat transfer process. A test plan for Melt Eruption Separate Effects Tests (MESET) has also been developed to provide information on the extent of crust growth and melt eruptions as a function of gas sparging rate under well-controlled experiment conditions. In terms of the second program objective, the project Management Board (MB) has approved startup activities required to carry out experiments to address remaining uncertainties related to long-term two-dimensional molten core-concrete interaction. In particular, for both wet and dry cavity conditions, there is uncertainty insofar as evaluating the lateral vs. axial power split during a core-concrete interaction due to a lack of experiment data. As a result, there are differences in the 2-D cavity erosion predicted by codes such as MELCOR, WECHSL, and COSACO. The first step towards generating this data is to produce a test plan for review by the Project Review Group (PRG). The purpose of this document is to provide this plan.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Concrete Waste Form Properties on Radionuclide Migration

Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation) the mechanism of contaminant release, the significance of contaminant release pathways, how waste form performance is affected by the full range of environmental conditions within the disposal facility, the process of waste form aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility, the effect of waste form aging on chemical, physical, and radiological properties and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the waste forms come in contact with groundwater. Numerous sets of tests were initiated in fiscal years (FY) 2006-2009 to evaluate (1) diffusion of iodine (I) and technetium (Tc) from concrete into uncontaminated soil after 1 and 2 years, (2) I and rhenium (Re) diffusion from contaminated soil into fractured concrete, (3) I and Re (set 1) and Tc (set 2) diffusion from fractured concrete into uncontaminated soil, (4) evaluate the moisture distribution profile within the sediment half-cell, (5) the reactivity and speciation of uranium (VI) (U(VI)) compounds in concrete porewaters, (6) the rate of dissolution of concrete monoliths, and (7) the diffusion of simulated tank waste into concrete.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transport through cracked concrete: literature review

Concrete containment structures and cement-based fills and waste forms are used at the Savannah River Site to enhance the performance of shallow land disposal systems designed for containment of low-level radioactive waste. Understanding and measuring transport through cracked concrete is important for describing the initial condition of radioactive waste containment structures at the Savannah River Site (SRS) and for predicting performance of these structures over time. This report transmits the results of a literature review on transport through cracked concrete which was performed by Professor Jason Weiss, Purdue University per SRR0000678 (RFP-RQ00001029-WY). This review complements the NRC-sponsored literature review and assessment of factors relevant to performance of grouted systems for radioactive waste disposal. This review was performed by The Center for Nuclear Waste Regulatory Analyses, San Antonio, TX, and The University of Aberdeen, Aberdeen Scotland and was focused on tank closure. The objective of the literature review on transport through cracked concrete was to identify information in the open literature which can be applied to SRS transport models for cementitious containment structures, fills, and waste forms. In addition, the literature review was intended to: (1) Provide a framework for describing and classifying cracks in containment structures and cementitious materials used in radioactive waste disposal, (2) Document the state of knowledge and research related to transport through cracks in concrete for various exposure conditions, (3) Provide information or methodology for answering several specific questions related to cracking and transport in concrete, and (4) Provide information that can be used to design experiments on transport through cracked samples and actual structures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Conceptual Design of a Thick Concrete Nondestructive Evaluation Specimen

Many important safety structures in a nuclear power plant (NPP) are constructed using concrete. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of NPPs beyond 60 years. In order to evaluate the current status of NPP structures, concrete inspection techniques must be developed and tested. Since in-service containment structures do not allow for destructive measures necessary to validate the accuracy of these inspection techniques, comparative testing of the various nondestructive evaluation (NDE) concrete measurement techniques will require concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. This report examines the need and availability of large concrete specimens to allow comparative testing of various NDE techniques, and the structural characteristics necessary for the specimens to serve as relevant representations of actual concrete structures in commercial NPPs.

concrete NDE↗

Online Monitoring of Concrete Structures in Nuclear Power Plants: Interim Report

The existing fleet of nuclear power plants in the United States have initial operating licenses of 40 years, and many of these plants have applied for and received license extensions. As plant structures, systems, and components age, their useful life—considering both structural integrity and performance—is reduced as a result of deterioration of the materials. Assessment and management of aging concrete structures in nuclear plants require a more systematic approach than simple reliance on existing code-based design margins of safety. Structural health monitoring is required to produce actionable information regarding structural integrity that supports operational and maintenance decisions. The online monitoring of concrete structures project conducted under the Advanced Instrumentation, Information, and Control Technologies Pathway of the Light Water Reactor Sustainability program at Idaho National Laboratory is seeking to develop and demonstrate capabilities for concrete structures health monitoring. Through this research project, several national laboratories and Vanderbilt University propose to develop a framework of research activities for the health monitoring of nuclear power plant concrete structures that includes the integration of four elements—damage modeling, monitoring, data analytics, and uncertainty quantification. This report briefly discusses activities in this project during October-December, 2014. The most significant activity during this period was the organizing of a two-day workshop on research needs in online monitoring of concrete structures, hosted by Vanderbilt University in November 2014. Thirty invitees from academia, industry and government participated in the workshop. The presentations and discussions at the workshop surveyed current activities related to concrete structures deterioration modeling and monitoring, and identified the challenges, knowledge gaps, and opportunities for advancing the state of the art; these discussions are summarized in this report

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that show much better agreement with the measured values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Concrete Structural Health Monitoring in Nuclear Power Plants

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed in order to understand the current condition of a structure based on heterogeneous measurements and then produce high confidence actionable information regarding structural integrity; this information can then be used to support operational and maintenance decisions. The paper describes a framework of research activities for the health monitoring of nuclear power plant concrete structures. The proposed framework consists of four elements: health monitoring, data analytics, uncertainty quantification, and prognosis. The goal of this framework is to enable plant operators to make risk-informed decisions on structural integrity, remaining useful life, and performance of concrete structures across the nuclear fleet. Among several concrete degradations, the research focuses on the degradation caused by the Alkali-Silica Reaction (ASR). ASR is a chemical reaction that in presence of sufficient moisture forms a gel that increases in volume and exerts an expansive pressure inside the material causing micro- to macro-cracks. The paper also presents development of controlled concrete samples with reactive aggregates to cause ASR degradation and application of different non-destructive evaluation techniques to detect the damage caused by ASR. Initial results are presented in the paper along with potential path forward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗