Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Relief of Residual Stress in Streamline Tie Rods by Heat Treatment

About two-thirds of the residual stress in cold-worked SAE 1050 steel tie rods was relieved by heating 30 minutes at 600 degrees Fahrenheit. Cold-worked austenitic stainless-steel tie rods could be heated at temperatures up to 1000 degrees Fahrenheit without lowering the important physical properties. The corrosion resistance, in laboratory corrosion test, of straight 18:8 and titanium-treated 18:8 materials appeared to be impaired after heating at temperatures above 800 degrees or 900 degrees fahrenheit. Columbium-treated and molybdenum-treated 18:8 steel exhibited improved stability over a wide range of temperatures. Tie rods of either material could be heated 30 minutes with safety at any temperature up to 1000 degrees Fahrenheit. At this temperature most of the residual stress would be relieved.

Pollard, R E↗

Evaluation of inorganic zinc-rich primers using Electrochemical Impedance Spectroscopy (EIS)

This investigation explores the use of Electrochemical Impedance Spectroscopy (EIS) in combination with beach exposure as a short term method for analyzing the performance of twenty-one zinc-rich primers. The twenty-one zinc-rich primers were: Carboline CZ-11, Ameron Devoe-Marine Catha-Coat 304, Briner V-65, Ameron D-21-9, Sherwin Williams Zinc Clad II, Carboline CZ-D7, Ameron D-4, Dupont Ganicin 347WB, Porter TQ-4374H, Inorganic Coatings IC-531, Subox Galvanox IV, Southern Coatings Chemtec 600, Glidden Glidzinc 5530, Byco SP-101, Tnemec 90E-75, Devoe Catha-Coat 302H, Glidden Glidzinc 5536, Koppers 701, Ameron D-21-5, Coronado 935-152, and Subox Galvanoz V. Data were also collected on galvanized steel for comparison purposes. A library of Bode magnitude plots was generated for each coating including curves for the initial time and after each week of atmospheric exposure as Beach Corrosion Test Site near the Space Shuttle launch pad at the Kennedy Space Center for up to three weeks. An examination of the variation of the Bode magnitude plots with atmospheric exposure revealed no clearly identifiable trend at this point that could distinguish between the good and the poor coatings. The test will be continued by including EIS measurements after six months and one year of atmospheric exposure.

Calle, Luz M.↗

NASA Tech Briefs, February 2008

Topics discussed include: Optical Measurement of Mass Flow of a Two-Phase Fluid; Selectable-Tip Corrosion-Testing Electrochemical Cell; Piezoelectric Bolt Breakers and Bolt Fatigue Testers; Improved Measurement of B(sub 22) of Macromolecules in a Flow Cell; Measurements by a Vector Network Analyzer at 325 to 508 GHz; Using Light to Treat Mucositis and Help Wounds Heal; Increasing Discharge Capacities of Li-(CF)(sub n) Cells; Dot-in-Well Quantum-Dot Infrared Photodetectors; Integrated Microbatteries for Implantable Medical Devices; Oxidation Behavior of Carbon Fiber-Reinforced Composites; GIDEP Batching Tool; Generic Spacecraft Model for Real-Time Simulation; Parallel-Processing Software for Creating Mosaic Images; Software for Verifying Image-Correlation Tie Points; Flexcam Image Capture Viewing and Spot Tracking; Low-Pt-Content Anode Catalyst for Direct Methanol Fuel Cells; Graphite/Cyanate Ester Face Sheets for Adaptive Optics; Atomized BaF2-CaF7 for Better-Flowing Plasma-Spray Feedstock; Nanophase Nickel-Zirconium Alloys for Fuel Cells; Vacuum Packaging of MEMS With Multiple Internal Seal Rings; Compact Two-Dimensional Spectrometer Optics; and Fault-Tolerant Coding for State Machines.

Source record↗

Reversible Chemochromic Hydrogen Detectors

The Florida Solar Energy Center (FSEC), affiliated with the University of Central Florida, has invented a reversible pigment that changes from light beige to blue when exposed to hydrogen and back to light beige when exposed to atmospheric oxygen. In laboratory and environmental studies, the FSEC pigment in its tape form failed to change color adequately when exposed to hydrogen after one day of exposure at Kennedy Space Center's Beach Corrosion Test Facility. The reversible hydrogen-detecting tape also lost its ability to change color after being placed in an environmental chamber at 45 C for one day. The first attempts at extruding the reversible pigment into various polymers were unsuccessful because of the pigment's poor thermal stability. The goal of this project was to formulate a pigment with improved thermal and environmental stability for extrusion into a variety of appropriate polymer matrices. The formulation of the reversible hydrogen-detecting pigment was modified by removing one reagent and chemically modifying the hydrogen sensitive ingredient. This was intended to improve the hydrophobicity of the pigment and alter the thermal degradation mechanism.

Source record↗

Less-Toxic Coatings for Inhibiting Corrosion of Aluminum

Two recently invented families of conversion- coating processes have been found to be effective in reducing or preventing corrosion of aluminum alloys. These processes offer less-toxic alternatives to prior conversion-coating processes that are highly effective but have fallen out of favor because they generate chromate wastes, which are toxic and carcinogenic. Specimens subjected to these processes were found to perform well in standard salt-fog corrosion tests.

Minevski, Zoran↗

Corrosion Atmospheric Exposure Facility PRL #239 SWMU Assessment Report/Confirmation Sampling Work Plan

The National Aeronautics and Space Administration (NASA) Resource Conservation and Recovery Act (RCRA) permit requires identification and evaluation of known Solid Waste Management Units (SWMU) located at the Kennedy Space Center (KSC). The Corrosion Atmospheric Exposure Facility (CAEF), also known as facility number K8-0600, and the Corrosion Test Area (CTA); also known as facility number K8-0237, herein referred to as the site, is designated Potential Release Location (PRL) 239 under the NASA RCRA permit. A SWMU Assessment (SA) was conducted between November 2019 and February 2020 to identify potential environmental impacts related to current and historic operations being conducted at the site. The SA included a site reconnaissance visit in February 2020, interviews with various personnel possessing knowledge of past work practices and operations at the site, and review of available historical documentation, engineering drawings, and facility inspection reports. Current site conditions were documented in photographs. Soil types and wildlife habitat were also evaluated. The objective of the assessment was to identify potential locations of concern (LOC) at the site and to determine whether further evaluation is required.

Kimberly Clower↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

burner rig↗

Evaluation of candidate alloys for the construction of metal flex hoses in the STS launch environment

Various vacuum jacketed cryogenic supply lines at the Shuttle launch site use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the flex hoses, which were made out of 304L stainless steel. A search was done to find a more corrosion resistant replacement material. Nineteen metal alloys were tested. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, long term exposure at the beach corrosion testing site, and pitting corrosion tests in ferric chloride solution. Based on the results, the most corrosion resistant alloys were found to be, in order, Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, and Inco Alloy G-3. Of these top five alloys, the Hastelloy C-22 stands out as being the best of the alloys tested.

Macdowell, Louis G., III↗

Evaluation of candidate alloys for the construction of metal flex hoses in the STS launch environment

Various vacuum jacketed cryogenic supply lines at the Shuttle launch site use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch, fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the flex hoses, which were made of 304L stainless steel. A search was done to find a more corrosion resistant replacement material. This study focused on 19 metal alloys. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, long term exposure at the beach corrosion testing site, and pitting corrosion tests in ferric chloride solution. Based on the results of these tests, the most corrosion resistant alloys were found to be (in order) Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, and Inco Alloy G-3. Of these top five alloys, the Hastelloy C-22 stands out as being the best of those tested for this application.

Ontiveros, Cordelia↗

Localized corrosion of high performance metal alloys in an acid/salt environment

Various vacuum jacketed cryogenic supply lines at the Space Shuttle launch site at Kennedy Space Center use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch, fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the thin walled 304L stainless steel flex hoses. A search was done to find a more corrosion resistant replacement material. The study focussed on 19 metal alloys. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, and long term exposure at a beach corrosion testing site. Based on the results of these tests, several nickel based alloys were found to have very high resistance to this corrosive environment. Also, there was excellent agreement between the electrochemical tests and the actual beach exposure tests. This suggests that electrochemical testing may be useful for narrowing the field of potential candidate alloys before subjecting samples to long term beach exposure.

Macdowell, L. G.↗

The effect of heat treatment and test parameters on the aqueous stress corrosion cracking of D6AC steel

The crack growth behavior of D6AC steel as a function of stress intensity, stress and corrosion history and test technique, under sustained load in natural seawater, 3.3 percent NaCl solution, distilled water, and high humidity air was investigated. Reported investigations of D6AC were considered with emphasis on thermal treatment, specimen configuration, fracture toughness, crack-growth rates, initiation period, threshold, and the extension of corrosion fatigue data to sustained load conditions. Stress history effects were found to be most important in that they controlled incubation period, initial crack growth rates, and apparent threshold.

Gilbreath, W. P.↗

The stress corrosion resistance and the cryogenic temperature mechanical properties of annealed Nitronic 60 bar material

Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments

Montano, J. W. L.↗