Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Reynolds-Averaged Navier-Stokes Perspective for the High Lift Common Research Model Using the LAVA Framework

An in-depth assessment of the High Lift-Common Research Model (HL-CRM) aerodynamic performance is made using a Reynolds-Averaged Navier-Stokes (RANS) methodology. Results presented here were produced in support of the 4th AIAA High Lift Prediction Workshop(HLPW-4), with additional simulation results and analysis used to support findings from the workshop. Mesh resolution, RANS closure models, and tunnel effects were among the sources of simulation sensitivity addressed, all in the pursuit of evaluating best-practice simulation methods for complex high-lift configurations. In general, free-air simulations using RANS yield accurate predictions of integrated loads in the pre-stall regime for the HL-CRM, while strong sensitivity to simulation method is observed near CLmax. Additionally, a study assessing changes in aerodynamic performance due to flap deflection angle indicated strong sensitivity to turbulence model closure and mesh resolution, particularly at the highest deflection setting. Several available corrections for the Spalart-Allmaras (SA) turbulence model were tested and generally introduced more error relative to the experiment in comparison to the baseline SA closure model. The Standard Menter Baseline Two-Equation (k-ωBSL) turbulence model was also explored, which arguably yielded results highly consistent with experiment, but at a substantially higher computational cost. Therefore, as a compromise between computational cost and accuracy, the baseline SA closure model was selected for additional HL-CRM studies that assess alternative solution methods. These strategies include “warm start” approaches, which initialize the simulation from a previously converged solution at a nearby angle of attack, unsteady calculations, and simulations that model the experimental wind tunnel. Results from these studies would reinforce the shortcomings of RANS in predicting aircraft performance at high-lift conditions, namely at high-αand highly loaded flap conditions, while also answering questions about appropriate modeling techniques to minimize the errors associated with RANS where possible

TTT↗

Aeroelastic Stability Assessment Methodology and Application to Slat Noise Treatments on the High-Lift Common Research Model

This work supports a larger effort at NASA to reduce airframe noise and, thus, environmental noise around airports. The leading-edge slat of conventional high-lift systems is a prominent source of airframe noise, and two technologies were previously identified as promising for noise reduction without significant aerodynamic or weight penalty: the slat cove filler (SCF) and the slat gap filler (SGF). NASA fabricated a 10%-scale semispan aircraft model for wind tunnel testing based upon the High-Lift Common Research Model (CRM-HL). NASA embarked on a test campaign with the 10% CRM-HL to determine the noise reduction effectiveness and other performance metrics of 3D SCF and SGF treatments in flow conditions representative of flight. The highly flexible SCF and SGF treatments posed a risk to the model and aeroelastic instability would compromise research integrity, so aeroelastic stability assessment was required. This work briefly describes the 10% CRM-HL, design of the SCF and SGF treatments to the model, and supporting fluid structure interaction (FSI) research. Relations for static and dynamic aeroelastic similitude are then developed for convenience of reference, and simplifications are introduced of particular utility to the cases considered in this study. The similitude relations are employed to assess the stability of the treatments under wind tunnel flow conditions based upon known behaviors from the supporting research. It is shown that the treatments are safe for test under the anticipated wind tunnel flow conditions with significant margins/factors of safety. It is furthermore demonstrated that the SCF is more susceptible to aeroelastic instability than the SGF, which has implications for flight feasibility.

Similitude↗

WMLES for the Fifth High-Lift PredictionWorkshop Cases Using FUN3D

This paper presents solution assessments and grid convergence studies for the test cases outlined in the Fifth High-Lift Prediction Workshop (HLPW-5), focusing on the high-lift Common Research Models (CRM-HL). The study utilizes a wall-modeled large-eddy simulation (WMLES) methodology developed in the unstructured-grid, node-centered flow solver FUN3D. The second-order accurate simulations conducted in this study utilize a finite-volume spatial discretization and an implicit temporal scheme. Large-scale turbulent features are resolved away from the wall, with small-scale effects captured by the Vreman subgrid-scale model. An equilibrium wall function uses the first grid point off the wall serving as the critical interface between the wall model and the large-eddy simulation region, thus requiring careful placement in grid design. WMLES solutions are assessed for HLPW-5 cases, including a clean wing-body configuration and geometry-buildup configurations corresponding to the 5.1\% ONERA CRM-HL model. Grid-convergence studies are systematically conducted using uniformly refined grids. Moreover, simulation results and grid sensitivity are presented for the NASA 5.2\% CRM-HL configuration at both moderate and flight-scale Reynolds numbers. Overall, WMLES results are satisfactory and agree well with available experimental data, especially on sufficiently fine grids.

high-lift aerodynamics↗

Update on the High Precision Titration Method for Uranium Assay Supported by NBL Program Office

The NBL Program Office (NBL PO) has coordinated with Oak Ridge National Laboratory (ORNL) to implement the High Precision Titration (HPT) method for uranium assay measurements. The measurement method has been successfully developed and qualified, therefore ORNL has progressed to performing analyzes critical to the mission of the NBL PO. The HPT method is vital to producing the next generation of certified reference materials for uranium assay and isotopic abundance. The work described here focused on establishing traceability of the method to the NIST SRM 136 potassium dichromate series, and focused on investigating small differences between SRM 136e and 136f. The NBL PO evaluated the history of all of its primary uranium reference materials, including CRM 112A natural uranium metal, and worked with NIST in investigating the small differences in the dichromate SRM’s. ORNL performed comparative experiments on SRM 136e and 136f using CRM 112A. The results of the experiment will be presented here, along with NBL PO’s plans to re-evaluate the CRM 112A certified uncertainty to comply with JCGM 100, “Guide to the expression of uncertainty in measurement.”

Rogers, Kayron↗

Semispan Test Results of an Active Flow Control Enabled High-Lift Common Research Model in Landing Configuration

A 10%-scale semispan, Active Flow Control (AFC) enabled, simplified high-lift version of the Common Research Model (CRM-SHL-AFC) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. The main objective of the test was to develop an AFC system that can provide the necessary lift recovery on a simple-hinged flap high-lift system while minimizing its pneumatic power requirement. Three new types of AFC approaches were examined: Double-Row Sweeping Jets (DRSWJ), Alternating Pulsed Jets (APJ), and High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used an upstream row of sweeping jets combined with a downstream row of steady jets to overcome strong adverse pressure gradients. The test was conducted mostly at a freestream Mach number of 0.20. For exploration purposes, a limited number of runs were made at lower Mach numbers or using vortex generators (VGs). Minimal sensitivity to Mach number or VGs, for the cases evaluated, were observed. The AFC-induced lift coefficient increment was maintained over the AFC-off case for most flow-control cases examined. The CRM-SHL-AFC configuration equipped with HELP actuation was the only actuator configuration able to match or exceed the targeted lift performance of a reference conventional high-lift configuration. The presented aerodynamic data include lift, drag, and pitching moment coefficients as a function of angle of attack, with and without the Transonic Wall Interference Correction System (TWICS) method applied. Lift increments as a function of AFC pneumatic power usage (i.e., nozzle pressure ratio, mass flow, momentum coefficient, and power coefficient) are also presented at a lower angle of attack (α = 8.9°) and at maximum lift (α= 17.1°). At the two angles of attack, the surface pressure distributions and autospectral densities from the unsteady pressure transducers for the AFC-off case and the best HELP actuation case are compared.

high-lift↗

On the Dependence of Simulated Convection on Domain Size in CRMs

Abstract We present a heuristic model to explain the suppression of deep convection in convection‐resolving models (CRMs) with a small number of grid columns, such as those used in super‐parameterized or multi‐scale modeling framework (MMF) general circulation models (GCM) of the atmosphere. Domains with few grid columns require greater instability to sustain convection because they force a large convective fraction, driving strong compensating subsidence warming. Updraft dilution, which is stronger for reduced horizontal grid spacing, enhances this effect. Thus, suppression of deep convection in CRMs with few grid columns can be reduced by increasing grid spacing. Radiative‐convective equilibrium simulations using standalone CRM simulations with the System for Atmospheric Modeling (SAM) and using GCM‐coupled CRM simulations with the Energy Exascale Earth System Model (E3SM)‐MMF confirm the heuristic model results.

CRM↗

Testing of High-Lift Common Research Model at Takeoff Configurations

The 10% scale High-Lift Common Research Model (CRM-HL) was tested in the NASA Langley 14- by 22-Foot Subsonic Tunnel (14x22) in support of the NASA Advanced Air Transport Technology (AATT) Project. The main objective of the wind tunnel test was to improve the aerodynamic performance of a representative aircraft model during takeoff operations using localized active flow control (AFC). This approach involves the application of AFC concepts locally to a relatively small region; therefore, it has the potential to cause minimal architectural change to current aircraft configurations. In addition, the power requirements of localized AFC could be supplied with onboard air resources. Recent exploratory studies identified the aileron as a target area for improving lift-to-drag ratio using localized AFC concepts. The idea is to deflect the ailerons beyond their nominal deflection angles and use AFC to reduce flow separation that occurs at larger aileron deflections. Several AFC concepts with different configurations were evaluated with the goal of achieving high-lift performance improvement. The assessment of AFC configurations is reported in a companion paper. The focus of the current paper is to report the data relevant to the CRM-HL takeoff configurations and establish a reference case for localized AFC application. Three takeoff configurations —reference, nominal, and high-lift improved—are documented. These takeoff configurations are obtained by varying aileron deflection. Wind tunnel measurements including surface static pressures and force and moment data are presented. In addition, surface tuft flow visualization, mainly on the aileron, is provided to understand the flow characteristics developed over the aileron during takeoff.

Lift-to-Drag↗

NASA 5.2%-Scale Semispan High Lift Common Research Model Wind Tunnel Test at the 14- by 22-Foot Subsonic Tunnel

A wind tunnel test of the NASA 5.2%-scale Semispan High Lift Common Research Model (CRM-HL) was conducted at the 14- by 22-Foot Subsonic Tunnel (14x22) in the fall of 2022. The main purpose of the test was a model checkout before shipping it overseas. The model was shipped to Germany in the spring of 2023, and the team wanted to be sure that instrumentation in the model was working, all of the model parts fit together well, and model changes could be done smoothly, as designed while installed in a wind tunnel. Force and moment and pressure data were collected during the test, and while these data were a secondary objective, they can be used for for tunnel-to-tunnel verification of the model, and for database supplementation for the NASA CRM-HL ecosystem. The test was run from August 15, 2022 through September 8, 2022. Eight configurations were tested at Mach 0.2 and 0.26, over an alpha range from -4deg to +24deg. All of the configurations that were tested accomplished testing of all model parts. This test campaign was a unique opportunity to test a complicated model design in a wind tunnel that is less expensive to test in and has easier model access than the tunnel that it was designed to run in. The test was invaluable in providing lessons learned about building up and running the model, and the model was returned to the model manufacturer from December 2022 to February 2023 for updates to make model changes easier, to make design fixes on the model, and to do clean up work on the model.

CRM-HL↗

Active Flow Control Enhanced Aileron of the High-Lift Common Research Model at Takeoff Condition

An experimental investigation was conducted in the NASA Langley 14- by 22-Foot Subsonic Tunnel on the NASA 10% scale High-Lift Common Research Model (CRM-HL) to improve the high-lift aerodynamic performance of the takeoff configuration. Active flow control (AFC) was applied at the aileron hinge line to control flow separation at high aileron deflection angles ( δ a ) to increase lift-to-drag ratio (R/J). Improvements in low speed R/J can increase vehicle payload and/or range resulting in a more efficient vehicle. Aileron deflection angles of 0°, 7.5°, 16°, and 25° were investigated. Flow control was applied to the two largest aileron deflections, which are considered the high-lift (HL) improved takeoff configurations. A companion paper will discuss baseline flow characteristics of the CRM-HL at the three takeoff conditions: reference, nominal, and HL-improved. In this paper, we focus on the aerodynamic improvement obtained when AFC was applied to δ a = 16° relative to the nominal configuration, δ a = 7.5°. Multiple flow control parameters, including actuator type, spacing, and intensity, were investigated to evaluate the efficiency of the actuation system. The different AFC configurations tested were assessed with tuft visualization, steady surface pressure data, and force and moment data. The results indicated that all actuation types and spacings examined led to an increase in lift across the range of angles of attack investigated. Flow separation was mitigated with the injection of momentum at the aileron hinge line. The configurations with the smallest spacing produced the highest improvement in L/D . Steady jet actuation showed higher efficiency but similar aerodynamic performance when compared to the sweeping jet actuators. This work was performed in support of the NASA Advanced Air Transport Technology (AATT) Project.

High-Lift Common Research Model↗

NASA 5.2%-Scale Semispan High Lift Common Research Model Wind Tunnel Test at the 14- by 22-Foot Subsonic Tunnel

A wind tunnel test of the NASA 5.2%-scale Semispan High Lift Common Research Model (CRM-HL) was conducted at the 14- by 22-Foot Subsonic Tunnel (14x22) in the fall of 2022. The main purpose of the test was a model checkout before shipping it overseas. The model was shipped to Germany in the spring of 2023, and the team wanted to be sure that instrumentation in the model was working, all of the model parts fit together well, and model changes could be done smoothly, as designed while installed in a wind tunnel. Force and moment and pressure data were collected during the test, and while these data were a secondary objective, they can be used for for tunnel-to-tunnel verification of the model, and for database supplementation for the NASA CRM-HL ecosystem. The test was run from August 15, 2022 through September 8, 2022. Eight configurations were tested at Mach 0.2 and 0.26, over an alpha range from -4deg to +24deg. All of the configurations that were tested accomplished testing of all model parts. This test campaign was a unique opportunity to test a complicated model design in a wind tunnel that is less expensive to test in and has easier model access than the tunnel that it was designed to run in. The test was invaluable in providing lessons learned about building up and running the model, and the model was returned to the model manufacturer from December 2022 to February 2023 for updates to make model changes easier, to make design fixes on the model, and to do clean up work on the model.

Semispan↗

Testing of High-Lift Common Research Model at Takeoff Configurations

The 10% scale High-Lift Common Research Model (CRM-HL) was tested in the NASA Langley 14- by 22-Foot Subsonic Tunnel (14x22) in support of the NASA Advanced Air Transport Technology (AATT) Project. The main objective of the wind tunnel test was to improve the aerodynamic performance of a representative aircraft model during takeoff operations using localized active flow control (AFC). This approach involves the application of AFC concepts locally to a relatively small region; therefore, it has the potential to cause minimal architectural change to current aircraft configurations. In addition, the power requirements of localized AFC could be supplied with onboard air resources. Recent exploratory studies identified the aileron as a target area for improving lift-to-drag ratio using localized AFC concepts. The idea is to deflect the ailerons beyond their nominal deflection angles and use AFC to reduce flow separation that occurs at larger aileron deflections. Several AFC concepts with different configurations were evaluated with the goal of achieving high-lift performance improvement. The assessment of AFC configurations is reported in a companion paper. The focus of the current paper is to report the data relevant to the CRM-HL takeoff configurations and establish a reference case for localized AFC application. Three takeoff configurations —reference, nominal, and high-lift improved—are documented. These takeoff configurations are obtained by varying aileron deflection. Wind tunnel measurements including surface static pressures and force and moment data are presented. In addition, surface tuft flow visualization, mainly on the aileron, is provided to understand the flow characteristics developed over the aileron during takeoff.

Wind tunnel test↗

Active Flow Control Enhanced Aileron of the High-Lift Common Research Model at Takeoff Condition

An experimental investigation was conducted in the NASA Langley 14- by 22-Foot Subsonic Tunnel on the NASA 10% scale High-Lift Common Research Model (CRM-HL) to improve the high-lift aerodynamic performance of the takeoff configuration. Active flow control (AFC) was applied at the aileron hinge line to control flow separation at high aileron deflection angles to increase lift-to-drag ratio (L/D). Improvements in low speed L/D can increase vehicle payload and/or range resulting in a more efficient vehicle. Aileron deflection angles of 0°, 7.5°, 16°, and 25° were investigated. Flow control was applied to the two largest aileron deflections, which are considered the high-lift (HL) improved takeoff configurations. A companion paper will discuss baseline flow characteristics of the CRM-HL at the three takeoff conditions: reference, nominal, and HL-improved. In this paper, we focus on the aerodynamic improvement obtained when AFC was applied to an aileron deflected at 16° relative to the nominal configuration of 7.5° deflection. Multiple flow control parameters, including actuator type, spacing, and intensity, were investigated to evaluate the efficiency of the actuation system. The different AFC configurations tested were assessed with tuft visualization, steady surface pressure data, and force and moment data. The results indicated that all actuation types and spacings examined led to an increase in lift across the range of angles of attack investigated. Flow separation was mitigated with the injection of momentum at the aileron hinge line. The configurations with the smallest spacing produced the highest improvement in L/D. Steady jet actuation showed higher efficiency but similar aerodynamic performance when compared to the sweeping jet actuators. This work was performed in support of the NASA Advanced Air Transport Technology (AATT) Project.

CRM-HL↗

International cooperation in age-dating uranium standards for nuclear forensics using the 231 Pa/ 235 U radiochronometer

During 2017–2018 Los Alamos National Laboratory, Lawrence Livermore National Laboratory and the China Institute of Atomic Energy collaborated in an interlaboratory 231 Pa/ 235 U radiochronometry exercise. The laboratories used different analytical methods to obtain a consensus model purification date for CRM U010 of December 28, 1958 ± 198 days and for CRM U850 of May 20, 1958 ± 363 days. These results agree with previously reported model dates using the 230 Th/ 234 U radiochronometer as well as the production histories of these materials. The concordance of interlaboratory data here confirms the ability of laboratories to make reproducible radiochronometry measurements using distinct analytical approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Load‐Balancing Intense Physics Calculations to Embed Regionalized High‐Resolution Cloud Resolving Models in the E3SM and CESM Climate Models

Abstract We design a new strategy to load‐balance high‐intensity sub‐grid atmospheric physics calculations restricted to a small fraction of a global climate simulation's domain. We show why the current parallel load balancing infrastructure of Community Earth System Model (CESM) and Energy Exascale Earth Model (E3SM) cannot efficiently handle this scenario at large core counts. As an example, we study an unusual configuration of the E3SM Multiscale Modeling Framework (MMF) that embeds a binary mixture of two separate cloud‐resolving model grid structures that is attractive for low cloud feedback studies. Less than a third of the planet uses high‐resolution (MMF‐HR; sub‐km horizontal grid spacing) relative to standard low‐resolution (MMF‐LR) cloud superparameterization elsewhere. To enable MMF runs with Multi‐Domain cloud resolving models (CRMs), our load balancing theory predicts the most efficient computational scale as a function of the high‐intensity work's relative overhead and its fractional coverage. The scheme successfully maximizes model throughput and minimizes model cost relative to precursor infrastructure, effectively by devoting the vast majority of the processor pool to operate on the few high‐intensity (and rate‐limiting) high‐resolution (HR) grid columns. Two examples prove the concept, showing that minor artifacts can be introduced near the HR/low‐resolution CRM grid transition boundary on idealized aquaplanets, but are minimal in operationally relevant real‐geography settings. As intended, within the high (low) resolution area, our Multi‐Domain CRM simulations exhibit cloud fraction and shortwave reflection convergent to standard baseline tests that use globally homogenous MMF‐LR and MMF‐HR. We suggest this approach can open up a range of creative multi‐resolution climate experiments without requiring unduly large allocations of computational resources.

54 ENVIRONMENTAL SCIENCES↗

Stable Machine‐Learning Parameterization of Subgrid Processes in a Comprehensive Atmospheric Model Learned From Embedded Convection‐Permitting Simulations

Modern climate projections often suffer from inadequate spatial and temporal resolution due to computational limitations, resulting in inaccurate representations of sub-grid processes. A promising technique to address this is the multiscale modeling framework (MMF), which embeds a kilometer-resolution cloud-resolving model (CRM) within each atmospheric column of a host climate model to replace traditional convection and cloud parameterizations. Machine learning offers a unique opportunity to make MMF more accessible by emulating the embedded CRM and reducing its substantial computational cost. Although many studies have demonstrated proof-of-concept success of achieving stable hybrid simulations, it remains a challenge to achieve near operational-level success with real geography and comprehensive variable emulation that includes, for example, explicit cloud condensate coupling. In this study, we present a stable hybrid model capable of integrating for at least 5 years with near operational-level complexity, including coarse-grid geography, seasonality, explicit cloud condensate and wind predictions, and land coupling. Our model demonstrates skillful online performance, achieving a 5-year zonal mean tropospheric temperature bias within 2 K, water vapor bias within 1 g/kg, and a precipitation root mean square error of 0.96 mm/day. Key factors contributing to our online performance include an expressive U-Net architecture and physical thermodynamic constraints for microphysics. With microphysical constraints mitigating unrealistic cloud formation, our work is the first to demonstrate realistic multi-year cloud condensate climatology under the MMF framework. Despite these advances, online diagnostics reveal persistent biases in certain regions, highlighting the need for innovative strategies to further optimize online performance.

Hu, Zeyuan [NVIDIA Corporation, Santa Clara, CA (U↗

Momentum informed muon scattering tomography for monitoring spent nuclear fuels in dry storage cask

Development of an effective monitoring method for spent nuclear fuel (SNF) in a dry storage cask (DSC) is important to meet the increasing demand for dry storage investigations. The DSC investigation should provide information about the quantity of stored SNF, and quality assurance of materials should be possible without opening the cask. However, traditional nondestructive examination (NDE) methods such as x-rays are difficult to deploy for DSC investigation because a typical DSC is intentionally designed to shield against radiation. To address this challenge, cosmic ray muons (CRMs) are used as an alternative NDE radiation probe because they can easily penetrate an entire DSC system; however, a wide application of muons is often hindered due to the naturally low CRM flux (~10 4 muons/m 2 /min). This paper introduces a newly proposed imaging algorithm, momentum-informed muon scattering tomography (MMST) , and presents how a limitation of the current muon scattering tomography technique has been addressed by measuring muon momentum. To demonstrate its functionality, a commercial DSC with 24 pressurized light water reactor fuel assemblies (FAs) and the MMST system were designed in GEANT4. Three noticeable improvements were observed for MMST system as a DSC investigation tool: (1) a signal stabilization, (2) an enhanced capability to differentiate various materials, and (3) statistically increased precision to identify and locate missing FAs. The results show that MMST improves the investigation accuracy from 79 to 98% when one FA is missing and 51% to 88% when one-half FA is missing. The advancement of the NDE technique using CRM for DSC verification is expected to resolve long-standing problems in increasing demand for DSC inspections and nuclear security.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗