Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles

Tri-structural isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using x-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the x-ray beam by the uranium core, leading to severe photon starvation in a substantial fraction of the measurements. Furthermore, the overall acquisition time for a high-resolution CT scan can be very long when using conventional laboratory-based x-ray systems and reconstruction algorithms. Specifically, when analytic methods such as the Feldkamp–Davis–Kress (FDK) algorithm are used for reconstruction, it results in severe streak artifacts and noise in the corresponding 3D volume, which makes subsequent analysis of the particles challenging. In this paper, we develop and apply model-based image reconstruction (MBIR) algorithms to improve the quality of CT reconstructions for TRISO particles to facilitate better characterization. We demonstrate that the proposed MBIR algorithms can significantly suppress artifacts with minimal pre-processing compared to conventional approaches. We also demonstrate that the proposed MBIR approach can obtain high-quality reconstruction compared to the FDK approach even when using a fraction of the typically acquired measurements, thereby enabling dramatically faster measurement times for TRISO particles.

Venkatakrishnan, Singanallur↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

In-situ imaging of flexure-induced fracture in tape-laminate composites using high-resolution X-ray computed tomography

Here, this study presents development of an in-situ flexure test for imaging progressive inter- and intralaminar fracture in tape-laminate composites using X-ray computed tomography (CT). The intent of this test is to provide detailed experimental observations of ply-level damage that can be used to validate existing, and develop new, progressive damage analysis (PDA) tools. The test consists of a vertically mounted specimen which is flexed using two eccentric compressive loads using an in-situ uniaxial load stage. The flexure specimen contains a starter notch mid-span which promotes initiation of composite failure within the X-ray field of view. Specimens with two different laminate stacking sequences were tested, imaged, analyzed. For a quasi-isotropic laminate with large angle changes between adjacent plies, there was near simultaneous growth of transverse cracks and delaminations below the midplane of the laminate. For a laminate with small angles between adjacent plies, there was extensive formation of transverse crack networks which penetrated the laminate thickness without delamination growth. In addition to imaging fracture, the X-ray CT data from both specimen types were used to quantify the variability in thickness and analyze the local orientation of individual plies. Overall, the proposed test and the image-data analysis methodology provided an important insight into the fracture processes in tape laminates and highlights the inherent ply-level geometrical variabilities that should be accounted for in PDA simulations.

42 ENGINEERING↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts A preliminary examination

What? Performed X-ray CT (XCT) on irradiated AGR-3/4 compacts Apparatus design Imaging results Preliminary analysis Extruded kernels DTF Identification Areas of interest for further exploration Why? Can provide non-destructive 3D perspective to enhance/compliment current PIE Potentially better quantitative measurements of certain features Better means of understanding any spatial distribution(s)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron tomography of porous aluminum electrodes used in electrocoagulation of groundwater

In this work, neutron computed tomography (CT) is employed to investigate the dissolution of porous aluminum electrodes during electrocoagulation (EC). Porous electrodes were chosen in efforts to reduce electric power requirements by using larger surface-area electrodes, having both inner and outer surface, for the EC process. Neutron CT allowed 3D reconstruction of the porous electrodes, and image analysis provided the volume of each electrode vs. thickness, which can indicate whether the inner surface is effectively involved in EC reactions. For the anode, the volume decreased uniformly throughout the thickness of the electrode, indicating that both the outer and inner surface participated in electrochemical dissolution, while the volume of the cathode increased uniformly vs. thickness, indicating deposition of material on both the outer and inner surface. The attenuation coefficient vs. thickness, increased for both anode and cathode, indicating surface chemistry changes. For the anode, the attenuation coefficient increased slightly but uniformly, probably due to aluminum oxide formation on the surface of the anode. For the cathode, the attenuation coefficient increased more than for the anode and nonuniformly. The higher increase in the attenuation coefficient for the cathode is due to precipitation of aluminum hydroxide on the electrode surface, which added hydrogen. Image analysis also showed that, although the attenuation coefficient increased throughout the thickness of the electrode, most of the hydroxide deposition occurred on the outer surface. Energy analysis showed that porous electrodes can be used to reduce process energy requirements by as much as 4 times compared to solid electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CT Scans of Cores Metadata, Utqiagvik (Barrow), Alaska, 2015

Individual ice cores were collected from Barrow Environmental Observatory in Barrow, Alaska, throughout 2013 and 2014. Cores were drilled along different transects to sample polygonal features (i.e. the trough, center and rim of high, transitional and low center polygons). Most cores were drilled around 1 meter in depth and a few deep cores were drilled around 3 meters in depth. Three-dimensional images of the frozen cores were constructed using a medical X-ray computed tomography (CT) scanner. TIFF files can be uploaded to ImageJ (an open-source imaging software) to examine soil structure and soil densities within each core.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Mid-infrared photodetection with 2D metal halide perovskites at ambient temperature

The detection of mid-infrared (MIR) light is technologically important for applications such as night vision, imaging, sensing, and thermal metrology. Traditional MIR photodetectors either require cryogenic cooling or have sophisticated device structures involving complex nanofabrication. Here, we conceive spectrally tunable MIR detection by using two-dimensional metal halide perovskites (2D-MHPs) as the critical building block. Leveraging the ultralow cross-plane thermal conductivity and strong temperature-dependent excitonic resonances of 2D-MHPs, we demonstrate ambient-temperature, all-optical detection of MIR light with sensitivity down to 1 nanowatt per square micrometer, using plastic substrates. Through the adoption of membrane-based structures and a photonic enhancement strategy unique to our all-optical detection modality, we further improved the sensitivity to sub–10 picowatt-per-square-micrometer levels. The detection covers the mid-wave infrared regime from 2 to 4.5 micrometers and extends to the long-wave infrared wavelength at 10.6 micrometers, with wavelength-independent sensitivity response. Our work opens a pathway to alternative types of solution-processable, long-wavelength thermal detectors for molecular sensing, environmental monitoring, and thermal imaging.

Li, Yanyan [Yale University, New Haven, CT (United↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow Quantification Through Potential CO2 Storage Formations

Multiscale Analyses with CT Scanning<p>How NETL Research and Innovation Center Core Flow and imaging lab is assisting CarbonSAFE and FECM-funded field efforts to meet FECM's Carbon Management goals is described in this presentation.</p>

Crandall, Dustin↗

Non-destructive evaluation and machine learning methods for inspection of spent nuclear fuel canisters: A state-of-the-art review

Nuclear energy is among the cleanest and most efficient energy sources currently available. The operation of nuclear power plants (NPPs) produces large amounts of high-level radioactive waste known as spent nuclear fuel (SNF). Currently, large amounts of SNF is stored in dry cask storage systems (DCSSs) for extended interim storage until a permanent disposal solution becomes available. During the extended interim storage, the DCSS, particularly the SNF canisters, may degrade and abnormal conditions may occur. Therefore, non-destructive evaluation (NDE) and machine learning (ML) approaches are necessary for inspection of SNF canisters. This paper presents a state-of-the-art review of literature by summarizing recent progress made on the applications of NDE and ML for inspection of SNF canisters. Sixteen NDE methods are examined and compared: visual inspection, ultrasonic guided waves (UGWs), laser-based approaches, acoustic emission (AE), eddy current testing (ECT), non-invasive acoustic sensing, dynamic modal testing, cosmic ray muons tomography, neutron imaging, gamma rays detection, fiber optical sensors, through-wall communications, X-ray computed tomography (CT), vibrothermography, monoenergetic photon sources, and surface acoustic wave (SAW) sensors. The technology readiness level (TRL) for each method is assessed and compared. Recent publications on ML-enhanced visual inspection, AE, non-invasive acoustic sensing, dynamic modal testing, and neutron imaging for SNF canisters are summarized and future research needs are identified. In conclusion, this review article provides a convenient reference on the state-of-the-art applications of NDE and ML methods for inspection of SNF canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualizing energy transfer between redox-active colloids

Redox-active colloids (RACs) represent a novel class of energy carriers that exchange electrical energy upon contact. Understanding contact-mediated electron transfer dynamics in RACs offers insights into physical contact events in colloidal suspensions and enables quantification of electrical energy transport in nonconjugated polymers. Redox-based electron transport was directly observed in monolayers of micron-sized RACs containing ethyl-viologen side groups via fluorescence microscopy through an unexpected nonlinear electrofluorochromism that is quantitatively coupled to the redox state of the colloid. Via imaging studies, using this electrofluorochromism, the apparent charge transfer diffusion coefficient D CT of the RAC was easily determined. The visualization of energy transport within suspensions of redox-active colloids was also demonstrated. Our work elucidates fundamental mechanisms of energy transport in colloidal systems, informs the development of next-generation redox flow batteries, and may inspire new designs of smart active soft matter including conductive polymers for applications ranging from electrochemical sensors and organic electronics to colloidal robotics.

Qu, Alan Subing [Univ. of Illinois at Urbana-Champ↗

A Computed Tomography Automation Architecture Developed from a Comprehensive Literature Review

This paper presents a literature review on techniques related to the computed tomography procedure that incorporate automation elements in their research investigations or industrial applications. Computed tomography (CT) is a non-destructive testing (NDT) technique in that the imaging and inspection are performed without damaging the sample, allowing for additional or repeated analysis if necessary. The reviewed literature is organized based on the steps associated with a general NDT task in order to define an end-to-end computed tomography automation architecture. The process steps include activities prior to image collection, during the scan, and after the data are collected. It further reviews efforts related to repeating this process based on a previous scan result. By analyzing the multiple existing but disparate efforts found in the literature, we present a framework for fully automating NDT procedures and discuss the remaining technical gaps in the developed framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗