Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be attributed to the smaller air gap between the probe and the 2-in access tube. The best-fit model relating volumetric water content to count ratio (CR) is of the form e^A x CR^B with A=0.3596 ± 0.0216 and B=0.4629 ± 0.0629 and r^2= 0.9998. It is recommended that the calibration function based on the count ratio, rather than raw counts, be used to avoid the effects of electronic noise in the probe that may arise due to the conditions at the time of measurement. These results suggest that the MCNP code can be used to extend calibrations for the neutron probe to different conditions including access tube size as well as composition without the need to construct additional physical models.

36 MATERIALS SCIENCE↗

Radiochromic film calibration for low-energy seed brachytherapy dose measurement

Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. Conclusions: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-221: Advantages of a New Surface Imaging Calibration Method for SRS Treatments

Purpose: The present calibration method used for the AlignRT surface imaging system relies on the placement of a calibration plate at the linac isocenter using isocenter surrogates (crosshairs, room lasers, etc.). This work investigated the potential advantages of a new calibration method that shifts the AlignRT isocenter to be coincident with the linac MV beam isocenter. Methods: To quantify the potential uncertainties associated with the present calibration method for SRS treatments, the calibration plate was intentionally shifted away from isocenter +/−3mm in the longitudinal and lateral directions and +/−1mm in the longitudinal, lateral, and vertical directions. A head phantom was placed in a mock SRS treatment position and monitored with the AlignRT system. The AlignRT-indicated offsets were recorded at 270, 315, 0, 45, and 90° couch angles for each intentional calibration misalignment. The new isocenter calibration was applied after each misalignment, and the measurements were repeated and compared to the previous results. Results: With intentional longitudinal and lateral shifts of +/−3mm and +/−1mm in the calibration plate, the average indicated offsets at couch rotations of +/−90° were 4.3mm and 1.6mm, respectively. This was in agreement with the theoretical offset of sqrt(2)*(intentional shift of the calibration plate). Since vertical shifts were along the rotation axis of the couch, these shifts had little effect on the offsets with changing couch angle. When the new calibration was applied, the indicated offsets were all within 0.5mm for all couch angles. These offsets were in agreement with the known magnitude of couch walkout. Conclusion: The potential pitfalls of the present calibration method have been established, and the advantages of the new calibration method have been demonstrated. This new calibration method effectively removes the potential miscalibration artifacts of the present calibration method, giving the AlignRT user more confidence in the system's indicated shifts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as a detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

On the Accuracy of the ALMA Flux Calibration in the Time Domain and across Spectral Windows

A diverse array of science goals requires accurate flux calibration of observations with the Atacama Large Millimeter/submillimeter array (ALMA); however, this goal remains challenging due to the stochastic time-variability of the “grid” quasars ALMA uses for calibration. In this work, we use 343.5 GHz (Band 7) ALMA Atacama Compact Array observations of four bright and stable young stellar objects over seven epochs to independently assess the accuracy of the ALMA flux calibration and to refine the relative calibration across epochs. The use of these four extra calibrators allows us to achieve an unprecedented relative ALMA calibration accuracy of ~3%. On the other hand, when the observatory calibrator catalog is not up to date, the Band 7 data calibrated by the ALMA pipeline may have a flux calibration poorer than the nominal 10%, which can be exacerbated by weather-related phase decorrelation when self-calibration of the science target is either not possible or not attempted. We also uncover a relative flux calibration uncertainty between spectral windows of 0.8%, implying that measuring spectral indices within a single ALMA band is likely highly uncertain. We thus recommend various methods for science goals requiring high flux accuracy and robust calibration, in particular, the observation of additional calibrators combined with a relative calibration strategy, and observation of solar system objects for high absolute accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Wide field array calibration dependence on the stability of measured dose distributions

Purpose: The aim of this work was to simulate the effect of dose distribution changes on detector array calibrations and to explore compensatory methods that are used during calibration measurements. Methods: The array calibration technique that was investigated is known as wide field (WF) calibration. Using this method, a linear array [y-axis (65 detectors) of the IC PROFILER (Sun Nuclear Corporation, Melbourne, FL)] is calibrated with three measurements ({alpha}, {theta}, and {lambda}); each measurement uses the same radiation field, which is larger than the array. For measurement configuration {theta}, the array is rotated by 180 deg. from its position in {alpha}; for {lambda}, the array is shifted by one detector from its position in {theta}. The relative detector sensitivities are then determined through ratios of detector readings at the same field locations (using {theta} and {lambda}). This method results in error propagation that is proportional to the number of detectors in the array. During the procedure, the calibration protocol operates under three postulates, which state that (a) the beam shape does not change between measurements; (b) the relative sensitivities of the detectors do not change; and (c) the scatter to the array does not change as the array is moved. The WF calibration's sensitivity to a postulate (a) violation was quantified by applying a sine shaped perturbation (of up to 0.1%) to {alpha}, {theta}, or {lambda}, and then determining the change relative to a baseline calibration. Postulate (a) violations were minimized by using a continuous beam and mechanized array movement during {theta} and {lambda}. A continuously on beam demonstrated more stable beam symmetry as compared to cycling the beam on and off between measurements. Additional side-scatter was also used to satisfy postulate (c). Results: Simulated symmetry perturbations of 0.1% to {theta} or {lambda} resulted in calibration errors of up to 2%; {alpha} was relatively immune to perturbation (<0.1% error). Wide field calibration error on a linear accelerator with similar symmetry variations was {+-}1.6%. Using a continuous beam during {theta} and {lambda} with additional side-scatter reduced the calibration error from {+-}1.6% to {+-}0.48%. Conclusions: This work increased the reproducibility of WF calibrations by limiting the effect of measurement perturbations primarily due to linear accelerator symmetry variations. The same technique would work for any array using WF calibration.

60 APPLIED LIFE SCIENCES↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.

Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when the balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.

47 OTHER INSTRUMENTATION↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercury Continuous Emmission Monitor Calibration

Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry (ID/ICP/MS) performed by NIST in Gaithersburg, MD. The outputs of mercury calibrators are compared to one another using a nesting procedure which allows direct comparison of one calibrator with another at specific concentrations and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define calibrator performance as affected by variables such as pressure, temperature, line voltage, and shipping. In 2007 WRI developed and conducted a series of simplified qualification experiments to determine actual calibrator performance related to the variables defined in the qualification portion of the interim protocol.

01 COAL, LIGNITE, AND PEAT↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of measurement conditions.

99 GENERAL AND MISCELLANEOUS↗

Bayesian optimal experimental design for constitutive model calibration

Computational simulation is increasingly relied upon for high/consequence engineering decisions, which necessitates a high confidence in the calibration of and predictions from complex material models. However, the calibration and validation of material models is often a discrete, multi-stage process that is decoupled from material characterization activities, which means the data collected does not always align with the data that is needed. To address this issue, an integrated workflow for delivering an enhanced characterization and calibration procedure—Interlaced Characterization and Calibration (ICC)—is introduced and demonstrated. Further, this framework leverages Bayesian optimal experimental design (BOED), which creates a line of communication between model calibration needs and data collection capabilities in order to optimize the information content gathered from the experiments for model calibration. Eventually, the ICC framework will be used in quasi real-time to actively control experiments of complex specimens for the calibration of a high-fidelity material model. This work presents the critical first piece of algorithm development and a demonstration in determining the optimal load path of a cruciform specimen with simulated data. Calibration results, obtained via Bayesian inference, from the integrated ICC approach are compared to calibrations performed by choosing the load path a priori based on human intuition, as is traditionally done. The calibration results are communicated through parameter uncertainties which are propagated to the model output space (i.e. stress–strain). In these exemplar problems, data generated within the ICC framework resulted in calibrated model parameters with reduced measures of uncertainty compared to the traditional approaches.

42 ENGINEERING↗

Providing radiometric traceability for the calibration home base of DLR by PTB

A dedicated calibration technique was applied for the calibration of the spectral radiance transfer standard (RASTA) of the German Aerospace Center (DLR) at the Physikalisch-Technische Bundesanstalt (PTB), consisting of two independent but complementing calibration procedures to provide redundancy and smallest possible calibration uncertainties. Procedure I included two calibration steps: In a first step the optical radiation source of RASTA, an FEL lamp, was calibrated in terms of its spectral irradiance E{sub {lambda}}({lambda}) in the wavelength range from 350 nm to 2400 nm using the PTB Spectral Irradiance Calibration Equipment (SPICE), while in a second step the spectral radiance factor {beta}{sub 0 Degree-Sign :45 Degree-Sign }({lambda}) of the RASTA reflection standard was calibrated in a 0 Degree-Sign :45 Degree-Sign -viewing geometry in the wavelength range from 350 nm to 1700 nm at the robot-based gonioreflectometer facility of PTB. The achieved relative standard uncertainties (k= 1) range from 0.6 % to 3.2 % and 0.1 % to 0.6 % respectively. Procedure II was completely independent from procedure I and allowed to cover the entire spectral range of RASTA from 350 nm to 2500 nm. In the second procedure, the 0 Degree-Sign :45 Degree-Sign -viewing geometry spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign }({lambda}) of RASTA was directly calibrated at the Spectral Radiance Comparator Facility (SRCF) of PTB. The relative uncertainties for this calibration procedure range from 0.8 % in the visible up to 7.5 % at 2500 nm (k= 1). In the overlapping spectral range of both calibration procedures the calculated spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign ,calc}({lambda}) from procedure I is in good agreement with the direct measurement of procedure II, i.e. well within the combined expanded uncertainties (k= 2) of both procedures.

43 PARTICLE ACCELERATORS↗