Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clean”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Clean room technology in surgery suites

The principles of clean room technology and the criteria for their application to surgery are discussed. The basic types of surgical clean rooms are presented along with their advantages and disadvantages. Topics discussed include: microbiology of surgery suites; principles of laminar airflow systems, and their use in surgery; and asepsis and the operating room.

Source record↗

Evaluation of plasma cleaning and electron spectroscopy for reduction of organic contamination

The use of Auger spectroscopy to evaluate the effectiveness of plasma cleaning procedures in decontaminating Viking spacecraft is examined. Also investigated was the use of Auger spectroscopy to monitor organic contamination. Results show plasma cleaning can be used effectively to remove organic films and that Auger spectroscopy can be used to monitor organic contamination.

Source record↗

Adhesion of metals to a clean iron surface studied with LEED and Auger emission spectroscopy.

Discussion of the results of adhesion experiments conducted with various metals contacting a clean iron surface. The metals included gold, silver, nickel, platinum, lead, tantalum, aluminum, and cobalt. Some of the metals were examined with oxygen present on their surface as well as in the clean state. The results indicate that, with the various metals contacting iron, the cohesively weaker will adhere and transfer to the cohesively stronger. The chemical activity of the metal also influenced the adhesive forces measured. With oxygen present on the metal surface, the adhesive forces measured could be correlated with the binding energy of the metal to oxygen.

Buckley, D. H.↗

ASRDI Oxygen Technology Survey. Volume 2: Cleaning Requirements, Procedures, and Verification Techniques

The oxygen system cleaning specifications drawn from 23 industrial and government sources are presented along with cleaning processes employed for meeting these specifications, and recommended postcleaning inspection procedures for establishing the cleanliness achieved. Areas of agreement and difference in the specifications, procedures, and inspection are examined. Also, the lack of clarity or specificity will be discussed. This absence of clarity represents potential safety hazards due to misinterpretation. It can result in exorbitant expenditures of time and money in satisfying unnecessary requirements.

Bankaitis, H.↗

Electrical contacts to ion cleaned n-type gallium arsenide.

The electrical current through silver contacts evaporated onto n-type gallium arsenide is reported as a function of surface treatment. Contacts to untreated gallium arsenide exhibit the expected high resistance. Surface cleaning by argon ion bombardment reduces the resistance by three orders of magnitude. The electrical resistance beyond 850 eV increases rapidly with ion bombardment energy. The resistance minimum at 850 eV is explained semiquantitatively in terms of a balance between cleaning and surface damage.

Walker, G. H.↗

Blade row dynamic digital compressor program. Volume 1: J85 clean inlet flow and parallel compressor models

The results are presented of a one-dimensional dynamic digital blade row compressor model study of a J85-13 engine operating with uniform and with circumferentially distorted inlet flow. Details of the geometry and the derived blade row characteristics used to simulate the clean inlet performance are given. A stability criterion based upon the self developing unsteady internal flows near surge provided an accurate determination of the clean inlet surge line. The basic model was modified to include an arbitrary extent multi-sector parallel compressor configuration for investigating 180 deg 1/rev total pressure, total temperature, and combined total pressure and total temperature distortions. The combined distortions included opposed, coincident, and 90 deg overlapped patterns. The predicted losses in surge pressure ratio matched the measured data trends at all speeds and gave accurate predictions at high corrected speeds where the slope of the speed lines approached the vertical.

Tesch, W. A.↗

Exoelectron emission from a clean, annealed magnesium single crystal during oxygen adsorption

Exoelectron emission has been observed from a clean, annealed Mg (0001) surface during oxygen and chlorine adsorption at pressures of 0.000065 N/sq m and lower. The studies were performed in an ultrahigh vacuum system. The crystals were cleaned by argon-ion bombardment and annealed at 300 C. Auger electron spectroscopy was used to verify surface cleanliness, and low-energy electron diffraction was used to verify that the surface was annealed. The emission was found to be dependent on oxygen arrival rate. Two peaks were observed in the electron emission with exposure. Evidence is presented that the formation of the second peak corresponds to oxidation of the Mg surface. The results verify that electron emission occurs from a strain-free surface simply upon adsorption of oxygen. A qualitative explanation for the mechanisms of emission in terms of chemical effects is presented.

Ferrante, J.↗

Space-age vacuum cleaning

Varied concepts for brushes and air handling remove dirt more effectively. Vacuum-cleaning techniques may be used in combination. Many of these concepts, while not appropriate for household cleaning, may find use in industry, research, and medicine.

Schneider, H. W.↗

Fibre evaluation for spacecraft cleaning

The employment of vacuum brushes utilizing sable tail hair for the physical removal of particulates from spacecraft surfaces has become problematical in connection with a lack of compatibility of the bristle with sterilization and biological decontamination procedures required for spacecraft cleaning. An investigation was, therefore, conducted to find a suitable fiber which can replace sable bristle. Felor fiber was found to have the best properties for use in a motorized cleaning brush.

Jensen, W. M.↗

Biological sampling and cleaning device

Flowing-liquid cleaner may be used to gently dislodge and remove 98 percent of biological particulates from surfaces. Cleaner may retain up to 90 percent of removed particulates for later analysis. If retention is not required, unit may be adapted to clean only. Cleaner is applicable wherever very clean surface is desired.

Scheider, H. W.↗

Ion-beam cleaning for cold welds

1000 eV beam bombarding metal surfaces to be joined removes oxides and contaminants at rate of several atomic layers per second for current density of 1 mA/squ. cm. Clean surfaces can then be joined by squeezing them together. With ion-beam cleaning, mating force for strong bond is low enough to cause only 1% deformation. Conventional cold-welding requires about 70% deformation for bonding. Technique was tested successfully on aluminum to aluminum welds, copper to copper, copper to aluminum, copper to nickel, and silver to iron. Base metals failed before welds in tear test.

Slater, B. L.↗

Brushless Cleaning of Solar Panels and Windows

Machine proposed for cleaning solar panels and reflectors uses multiple vortexes of air, solvent, and water to remove dust and dirt. Uses no brushes that might abrade solar surfaces and thereby reduce efficiency. Machine can be readily automated and can be used on curved surfaces such as aparbolic reflectors as well as on flat ones. Cleaning fluids are recycled, so that large quantities of water and solvent are not needed.

Schneider, H. W.↗

Self-Cleaning Tubular-Membrane Module

Tubular membranes made self-cleaning with aid of flow reversing valve. Sponge balls scrub membrane surfaces as they travel inside membrane tubes. A four-way flow-reversal valve automatically reverses flow in tubes at preset intervals so sponge balls reciprocate along tubes. Baskets at ends of tubes prevent sponges from escaping. Automatic cleaning feature added to existing membrane processing equipment with minimal modifications.

Sarbolouki, M. N.↗

Cleaning of Liquid N2O4

Technique useful in reducing clogging of fluid lines. Metal nitrate impurities precipitated from N2O4 by cooling N2O4 in heat exchanger and passing through hydraulic pump. Precipitate removed by fine membrane filter. Technique developed for cleaning of liquid N2O4 adaptable to cleaning of variety of industrial fluids, including fuels.

Pfeifer, G. R.↗

Collection and analysis of NASA clean room air samples

The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

Sheldon, L. S.↗

Relationship between peroxyacetyl nitrate and nitrogen oxides in the clean troposphere

The first study is presented in which the mixing ratios of peroxyactyl nitrate (PAN) and nitrogen oxides, as well as those of peroxypropionyl nitrate and O3 and relevant meteorological parameters, were measured concurrently at a location that receives clean, continental air. The results show that, in clean conditions, nitrogen oxides present in the form of PAN can be as much or more abundant than the inorganic form. In addition, PAN can be an important source of peroxyacetyl radicals which may be important to oxidation processes in the gas as well as liquid phases.

Singh, H. B.↗