Search NASASearch

SEARCH · Search NASA

Results for “Compact accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Compact Dual-Crystal Modulated Birefringence-Measurement System for Microgravity Applications

A compact modulated birefringence-measurement system has been developed for use in microgravity fluid physics applications with non-Newtonian fluids such as polymer solutions. This instrument uses a dual-crystal transverse electro-optical modulator capable of modulation frequencies in excess of 100 MHz. The two crystals are modulated 180 deg. out of phase from each other, The theoretical framework governing the development of this instrument using the Mueller-Stokes polarization matrices is discussed. Several ground-based experiments are performed to compare this system with the theoretical results. Results from this transverse electro-optical modulator-based birefringence-measurement system agree well with the theory. The instrument is also very stable and robust, making it suitable for the extreme acceleration environment to be encountered in a NASA Black Brandt sounding rocket.

Mackey, Jeffrey R.

LISA Pathfinder

USA Pathfinder is a space mission dedicated to demonstrating technology for the Laser Interferometer Space Antenna (LISA). LISA is a joint ESA/NASA mission to detect low-frequency gravitational waves on the 0.0001 to 0.1 Hz frequency band. LISA is expected to observe 100's of merging massive black hole binaries out z-15, tens of thousands of close compact binary systems in the Milky Way, merging intermediate-mass black hole binaries, tens of stellar-mass black holes falling into supermassive black holes in galactic centers, and possibly other exotic sources. Several critical LISA technologies have not been demonstrated at the requisite level of performance. In spaceflight, and some fight hardware cannot be tested in a 1-g environment. Hence, the LISA Pathfinder mission is being implemented to demonstrate these critical LISA technologies in a relevant flight environment. LISA Pathfinder mimics one arm of the LISA constellation by shrinking the 5-million-kilometer armlength down to a few tens of centimeters. The experimental concept is to measure the relative separation between two test masses nominally following their own geodesics, and thereby determine the relative residual acceleration between them near 1 mHz, about a decade above the lowest frequency required by LISA. To implement such a concept, disturbances on the test masses must be kept very small by many design features, but chiefly by "drag-free" flight. A drag-free spacecraft follows a free-falling test mass which it encloses, but has no mechanical connection to. The spacecraft senses it's orientation and separation with respect to the proof mass, and its propulsion system is commanded to keep the spacecraft centered about the test mass. Thus, the spacecraft shields the test mass from most external influences, and minimizes the effect of force gradients arising from the spacecraft, and acting on the test mass. LISA Pathfinder will compare the geodesic of one test mass against that of the other. Only a metrology system based on interferometry can achieve the displacement sensitivity. Interferometers monitor the separation of both test masses with a sensitivity comparable to that required by LISA, and using the same technologies. LISA Pathfinder is scheduled to be launched in the first half of 1020 to a Lissajous orbit around the first Sun-Earth Lagrange point, L1. In addition to a complete European technology package (the LISA Technology Package, or LTP), LISA Pathfinder will also carry thrusters and software, known as ST-7, a part of NASA's New Millennium Program.

Stebbins, Robin

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.

Stellar winds in binary X-ray systems

It is thought that accretion from a strong stellar wind by a compact object may be responsible for the X-ray emission from binary systems containing a massive early-type primary. To investigate the effect of X-ray heating and ionization on the mass transfer process in systems of this type, an idealized model is constructed for the flow of a radiation-driven wind in the presence of an X-ray source of specified luminosity, L sub x. It is noted that for low values of L sub x, X-ray photoionization gives rise to additional ions having spectral lines with wavelengths situated near the peak of the primary continuum flux distribution. As a consequence, the radiation force acting on the gas increases in relation to its value in the absence of X-rays, and the wind is accelerated to higher velocities. As L sub x is increased, the degree of ionization of the wind increases, and the magnitude of the radiation force is diminished in comparison with the case in which L sub x = 0. This reduction leads at first to a decrease in the wind velocity and ultimately (for L sub x sufficiently large) to the termination of radiatively driven mass loss.

Macgregor, K. B.

Variability of compact radio sources at a wavelength of 1 millimeter

Broad-band 1 mm continuum observations of 3C 273, 3C 279, BL Lac, 3C 84, OJ 287, and 3C 345 made between 1977 March and 1981 January are reported. With the possible exception of 3C 279, all of the objects exhibited evidence for variability in the 1 mm flux density on the time scale of a few months. Flux variations at wavelengths of 1 mm and 2 cm are well correlated for the 'blazars' (BL Lac objects and optically violent variable quasars) observed; emission outbursts occur simultaneously and have similar amplitude at the two wavelengths. In contrast, an outburst in the flux from the Seyfert galaxy 3C 84 was observed at a wavelength of 1 mm in early 1980 but has not appeared at 2 cm as of 1 yr later. The observed relationship between 'blazar' emission variability at 1 mm and 2 cm is inconsistent with the canonical expanding-source model of radio variability or any of its modifications. Instead, models in which the number of synchrotron-radiating electrons is time variable (due to particle injection or acceleration behind a relativistic shock) are required.

Ennis, D. J.

A Microseismometer for Terrestrial and Extraterrestrial Applications

The scientific and technical requirements of extraterrestrial seismology place severe demands on instrumentation. Performance in terms of sensitivity, stability, and frequency band must match that of the best terrestrial instruments, at a fraction of the size, mass, and power. In addition, this performance must be realized without operator intervention in harsh temperature, shock, and radiation environments. These constraints have forced us to examine some fundamental limits of accelerometer design in order to produce a small, rugged, sensitive seismometer. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, low-power and -mass accelerometers. However, currently available sensors offer inadequate sensitivity and bandwidth. Our implementation of an advanced silicon micro machined seismometer is based on principles developed at JPL for high-sensitivity position sensor technology. The use of silicon micro machining technology with these new principles should enable the fabrication of a 10(exp -11) g sensitivity seismometer with a bandwidth of at least 0.01 to 20 Hz. The low Q properties of pure single-crystal silicon are essential in order to minimize the Brownian thermal noise limitations generally characteristic of seismometers with small proof masses. A seismometer consists of a spring-supported proof mass and a transducer for measuring its motion. For long period motion a position sensor is generally used, for which the displacement is proportional to the ground acceleration. The mechanical sensitivity can be increased either by increasing the proof mass or decreasing the spring stiffness, neither of which is desirable for planetary applications. Our approach has been to use an ultra sensitive capacitive position sensor with a sensitivity of better than 10(exp -13) m/Hz(exp 1/2). This allows the use of a stiffer suspension and a smaller proof mass. We have built several prototypes using these principles, and tests show that these devices can exhibit performance comparable to state-of-the-art instruments.

Banerdt, W.

Classification of solar flares and the relationship between the first and second phases

A large data base on solar flares obtained during the last solar maximum years makes it necessary to revise the views on the relationship between the impulsive phase and the second phase of flares. Contrary to the view most popular before the launch of the Solar Maximum Mission, it is now known that relativistic electrons and gamma-ray-producing protons and ions are accelerated during the impulsive phase. Because flares producing nuclear gamma-rays are different from ordinary flares, it is concluded that additional processes take place in gamma-ray-line flares. Recent studies have shown that flares with gradual hard X-ray time profiles not only produce nuclear gamma-rays during the impulsive phase but also develop full-fledged second-phase phenomena. It is proposed that filament eruption plays a key role in gamma-ray-line flares. When an erupting filament interacts with an overlaying flare loop, relativistic electrons and energetic protons are produced during the impulsive phase. When the erupting filament fully distends the overlying flare loop, full-fledged second-phase phenomena, such as shocks, interplanetary energetic particles, mass ejections and etc. are observed. When the overlying flare loop is compact and strong enough to suppress the activated filament, gamma-rays are emitted during the first phase but no second-phase phenomena occur.

Bai, T.

An alpha particle instrument with alpha, proton, and X-ray modes for planetary chemical analyses

The interaction of alpha particles with matter is employed in a compact instrument that could provide rather complete in-situ chemical analyses of surfaces and thin atmospheres of extraterrestrial bodies. The instrument is a miniaturized and improved version of the Surveyor lunar instrument. The backscattering of alpha particles and (alpha, p) reactions provide analytical data on the light elements (carbon-iron). An X-ray mode that detects the photons produced by the alpha sources provides sensitivity and resolution for the chemical elements heavier than about silicon. The X-rays are detected by semiconductor detectors having a resolution between 150 and 250 eV at 5.9 keV. Such an instrument can identify and determine with good accuracy 99 percent of the atoms (except hydrogen) in rocks. For many trace elements, the detecting sensitivity is a few ppm. Auxiliary sources could be used to enhance the sensitivities for elements of special interest. The instrument could probably withstand the acceleration involved in semi-hard landings.

Economou, T. E.

Direct evidence for chromospheric evaporation in a well-observed compact flare

Observations of the solar flare of May 7, 1980 using several Solar Maximum Mission instruments are presented as an investigation of the phenomenon of chromospheric evaporation. The total amount of plasma at temperatures greater than 2 x 10 to the 6th K were determined from the X-ray data, and the amount of plasma that was evaporated from the chromosphere was determined from the H-alpha data. The H-alpha profiles indicate that for the flare as a whole, at the time of peak soft X-ray emission measure, the number of atoms evaporated from the chromosphere was 7 x 10 to the 37th. The soft X-ray emission measure of 1 x 10 to the 49th/cu cm, coupled with the flare volume estimate of 10 to the 26th cu cm, indicates that there were 3 x 10 to the 37th electrons in the soft X-ray plasma with temperatures greater than 2 x 10 to the 6th K. These results indicate that enough material had been evaporated from the chromosphere to account for the X-ray plasma. Taken together, the H-alpha, soft X-ray, and hard X-ray images indicate that chromospheric evaporation is driven both by flare-accelerated electrons during the impulsive phase and by conduction during the thermal phase.

Canfield, R. C.

Compact Sensitive Piezoelectric Mass Balance for Measurement of Unconsolidated Materials in Space

In many in-situ instruments information about the mass of the sample could aid in the interpretation of the data and portioning instruments might require an accurate sizing of the sample mass before dispensing the sample. In addition, on potential sample return missions a method to directly assess the captured sample size would be required to determine if the sampler could return or needs to continue attempting to acquire sample. In an effort to meet these requirements piezoelectric balances were developed using flextensional actuators which are capable of monitoring the mass using two methods. A piezoelectric balance could be used to measure mass directly by monitoring the voltage developed across the piezoelectric which is linear with force, or it could be used in resonance to produce a frequency change proportional to the mass change. In this case of the latter, the piezoelectric actuator/balance would be swept in frequency through its fundamental resonance. If a mass is added to the balance the resonance frequency would shift down proportionally to the mass. By monitoring the frequency shift the mass could be determined. This design would allow for two independent measurements of the mass. In microgravity environments spacecraft thrusters could be used to provide acceleration in order to produce the required force for the first technique or to bring the mass into contact with the balance in the second approach. In addition, the measuring actuators, if driven at higher voltages, could be used to fluidize the powder to aid sample movement. In this paper, we outline some of our design considerations and present the results of a few prototype balances that we have developed.

resonance

Planck Early Results. XV. Spectral Energy Distributions and Radio Continuum Spectra of Northern Extragalactic Radio Sources

Spectral energy distributions (SEDs) and radio continuum spectra are presented for a northern sample of 104 extragalactic radio sources. based on the Planck Early Release Compact Source Catalogue (ERCSC) and simultaneous multi frequency data. The nine Planck frequencies, from 30 to 857 GHz, are complemented by a set of simultaneous observations ranging from radio to gamma-rays. This is the first extensive frequency coverage in the radio and millimetre domains for an essentially complete sample of extragalactic radio sources, and it shows how the individual shocks, each in their own phase of development, shape the radio spectra as they move in the relativistic jet. The SEDs presented in this paper were fitted with second and third degree polynomials to estimate the frequencies of the synchrotron and inverse Compton (IC) peaks, and the spectral indices of low and high frequency radio data, including the Planck ERCSC data, were calculated. SED modelling methods are discussed, with an emphasis on proper. physical modelling of the synchrotron bump using multiple components. Planck ERCSC data also suggest that the original accelerated electron energy spectrum could be much harder than commonly thought, with power-law index around 1.5 instead of the canonical 2.5. The implications of this are discussed for the acceleration mechanisms effective in blazar shock. Furthermore in many cases the Planck data indicate that gamma-ray emission must originate in the same shocks that produce the radio emission.

Aatrokoski, J.

Hypervelocity gun

A velocity amplifier system which uses both electric and chemical energy for projectile propulsion is provided in a compact hypervelocity gun suitable for laboratory use. A relatively heavy layer of a tamping material such as concrete encloses a loop of an electrically conductive material. An explosive charge at least partially surrounding the loop is adapted to collapse the loop upon detonation of the charge. A source of electricity charges the loop through two leads, and an electric switch which is activated by the charge explosive charge, disconnects the leads from the source of electricity and short circuits them. An opening in the tamping material extends to the loop and forms a barrel. The loop, necked down in the opening, forms the sabot on which the projectile is located. When the loop is electrically charged and the explosive detonated, the loop is short circuited and collapsed thus building up a magnetic field which acts as a sabot catcher. The sabot is detached from the loop and the sabot and projectile are accelerated to hypervelocity.

Ford, F. C.

On the Anticorrelation Between High Accretion Luminosity and Radio Jet Ejection in Gro J1655-40 and Other Objects

A model is described in which radio jet formation in accreting objects is suppressed by processes which occur when the accretion rate approaches the Eddington limit. This was motivated by GRO J1655-40 and other objects which show an anticorrelation between high luminosity and the onset of a radio jet. The jet production mechanism employed is the Blandford-Payne MHD acceleration process, seeded by an e'e- pair wind. Observations indicate that all key ingredients of this mechanism are, or should be, present in these sources. Observed jet velocities and total powers are consistent with theoretical and numerical predictions of this model. The primary jet suppression mechanism proposed is the Papaloizou-Pringle compressible shear instability, which should disrupt the jet-producing region of the disk when the accretion rate approaches about one-third Eddington. The turn-on of the jet in GRO J 1 655 - 40 is consistent with this estimate. When super-Eddington, the disk should also drive an optically thick, subrelativistic wind, which may be a secondary jet suppression mechanism. The possible presence of such a wind is seen in the early spectral evolution of GRO J1655-40 and in the broad absorption lines of certain quasi-stellar objects (QSOs). Important tests of the model would be independent measurements of the compact object masses in these sources, a comparison of normal and broad absorption line (BAL) QSO X-ray spectra to see if the latter objects are significantly cooler, and a low-frequency search around BAL QSOs to see if at least some have fossil radio sources.

Meier, D.

High Velocity Linear Induction Launcher with Exit-Edge Compensation for Testing of Aerospace Components

Advances in ultra high speed linear induction electromagnetic launchers over the past decade have focused on magnetic compensation of the exit and entry-edge transient flux wave to produce efficient and compact linear electric machinery. The paper discusses two approaches to edge compensation in long-stator induction catapults with typical end speeds of 150 to 1,500 m/s. In classical linear induction machines, the exit-edge effect is manifest as two auxiliary traveling waves that produce a magnetic drag on the projectile and a loss of magnetic flux over the main surface of the machine. In the new design for the Stator Compensated Induction Machine (SCIM) high velocity launcher, the exit-edge effect is nulled by a dual wavelength machine or alternately the airgap flux is peaked at a location prior to the exit edge. A four (4) stage LIM catapult is presently being constructed for 180 m/s end speed operation using double-sided longitudinal flux machines. Advanced exit and entry edge compensation is being used to maximize system efficiency, and minimize stray heating of the reaction armature. Each stage will output approximately 60 kN of force and produce over 500 G s of acceleration on the armature. The advantage of this design is there is no ablation to the projectile and no sliding contacts, allowing repeated firing of the launcher without maintenance of any sort. The paper shows results of a parametric study for 500 m/s and 1,500 m/s linear induction launchers incorporating two of the latest compensation techniques for an air-core stator primary and an iron-core primary winding. Typical thrust densities for these machines are in the range of 150 kN/sq.m. to 225 kN/sq.m. and these compete favorably with permanent magnet linear synchronous machines. The operational advantages of the high speed SCIM launcher are shown by eliminating the need for pole-angle position sensors as would be required by synchronous systems. The stator power factor is also improved.

Kuznetsov, Stephen

Induction Heating Model of Cermet Fuel Element Environmental Test (CFEET)

Deep space missions with large payloads require high specific impulse and relatively high thrust to achieve mission goals in reasonable time frames. Nuclear Thermal Rockets (NTR) are capable of producing a high specific impulse by employing heat produced by a fission reactor to heat and therefore accelerate hydrogen through a rocket nozzle providing thrust. Fuel element temperatures are very high (up to 3000 K) and hydrogen is highly reactive with most materials at high temperatures. Data covering the effects of high‐temperature hydrogen exposure on fuel elements are limited. The primary concern is the mechanical failure of fuel elements due to large thermal gradients; therefore, high‐melting‐point ceramics‐metallic matrix composites (cermets) are one of the fuels under consideration as part of the Nuclear Cryogenic Propulsion Stage (NCPS) Advance Exploration System (AES) technology project at the Marshall Space Flight Center. The purpose of testing and analytical modeling is to determine their ability to survive and maintain thermal performance in a prototypical NTR reactor environment of exposure to hydrogen at very high temperatures and obtain data to assess the properties of the non‐nuclear support materials. The fission process and the resulting heating performance are well known and do not require that active fissile material to be integrated in this testing. A small‐scale test bed; Compact Fuel Element Environmental Tester (CFEET), designed to heat fuel element samples via induction heating and expose samples to hydrogen is being developed at MSFC to assist in optimal material and manufacturing process selection without utilizing fissile material. This paper details the analytical approach to help design and optimize the test bed using COMSOL Multiphysics for predicting thermal gradients induced by electromagnetic heating (Induction heating) and Thermal Desktop for radiation calculations.

Gomez, C. F.

Induction Heating Model of Cermet Fuel Element Environmental Test (CFEET)

Deep space missions with large payloads require high specific impulse and relatively high thrust to achieve mission goals in reasonable time frames. Nuclear Thermal Rockets (NTR) are capable of producing a high specific impulse by employing heat produced by a fission reactor to heat and therefore accelerate hydrogen through a rocket nozzle providing thrust. Fuel element temperatures are very high (up to 3000 K) and hydrogen is highly reactive with most materials at high temperatures. Data covering the effects of high‐temperature hydrogen exposure on fuel elements are limited. The primary concern is the mechanical failure of fuel elements due to large thermal gradients; therefore, high‐melting‐point ceramics‐metallic matrix composites (cermets) are one of the fuels under consideration as part of the Nuclear Cryogenic Propulsion Stage (NCPS) Advance Exploration System (AES) technology project at the Marshall Space Flight Center. The purpose of testing and analytical modeling is to determine their ability to survive and maintain thermal performance in a prototypical NTR reactor environment of exposure to hydrogen at very high temperatures and obtain data to assess the properties of the non‐nuclear support materials. The fission process and the resulting heating performance are well known and do not require that active fissile material to be integrated in this testing. A small‐scale test bed; Compact Fuel Element Environmental Tester (CFEET), designed to heat fuel element samples via induction heating and expose samples to hydrogen is being developed at MSFC to assist in optimal material and manufacturing process selection without utilizing fissile material. This paper details the analytical approach to help design and optimize the test bed using COMSOL Multiphysics for predicting thermal gradients induced by electromagnetic heating (Induction heating) and Thermal Desktop for radiation calculations.

Gomez, Carlos F.

Recurrent 3he-Rich Solar Energetic Particle Injections Observed By Solar Orbiter at ∼0.5 Au

We report Solar Orbiter observations of six recurrent solar energetic particle injections in 2022 March 3−6 at ∼0.5 au. All but one were associated with jets emanating from a plage near a large sunspot in active region 12 957. We saw large jets in injections with high 3He and Fe enrichments and minor jets in injections with no or lower enrichments. Furthermore, the event with the highest enrichment showed a more compact configuration of the underlying photospheric magnetic field. The higher fluences as well as harder spectra were seen in the event with a simultaneous jet and wider eruption. However, in this case, the energy buildup time in the source might be required to produce such spectra. Extreme-ultraviolet images from Solar Orbiter revealed a number of intersecting loops at the base of jets not seen from 1 au that might be a precondition for the recurrent events.

Sun: particle emission

The effects of radiation drag on radial, relativistic hydromagnetic winds

The effects of drag on an idealized relativistic MHD wind of radial geometry are studied. The astrophysical motivation is to understand the effects of radiation drag on the dynamics of a jet or wind passing through the intense radiation field of an accreting compact object. From a critical point analysis, it is found that a slow magnetosonic point can appear in a dragged flow even in the absence of gravitational force, as a result of a balance between the drag force and the combination of thermal pressure and centrifugal forces. As in the undragged case, the Alfven point does not impose any constraints on the flow. Although it is formally possible for a dragged flow to possess more than one fast magnetosonic point, it is shown that this is unlikely in practice. In the limit of a 'cold', centrifugally driven flow, it is shown that the fast magnetosonic point moves to infinite radius, just as in the drag-free case. For a given mass flux, the total energy output carried to infinity, and the final partition between the kinetic energy and the Poynting flux, are the same for the dragged and the drag-free flows. The main effects of radiation drag are to increase the amount of energy and angular momentum extracted from the source and to redistribute the regions where acceleration occurs in the flow. This is accomplished through the storage and release of magnetic energy, as a result of additional winding and compression of the field caused by the action of the drag. For a relativistic wind, the dissipated energy can exceed the final kinetic energy of the flow and may be comparable to the total flow energy (which is dominated by Poynting flux). The energy lost to radiation drag will appear as a Doppler-boosted beam of scattered radiation, which could dominate the background radiation if the flow is well-collimated.

Li, Zhi-Yun