Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compliance Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Air Exchange Rate Impact on Activity Equilibrium Factors and Inhalation Fractional Equilibrium Factors for Rn, Xe, Kr, Ar, Ne, and Their Progeny in Vapor Intrusion, Risk, and Dose Models

Exposure to the radioactive noble gasses, especially radon, is of high concern and poses a significant risk to humans in an indoor air environment as the second leading cause of lung cancer in the United States. To evaluate and minimize the risks posed by these gasses, it is important to understand their radiological and physical properties. The EPA’s Radon Vapor Intrusion Screening Level (RVISL) calculator calculates indoor air RVISLs based on target working levels (WLs), target excess lifetime cancer risk (ELCR), and annual dose limits for the actinon (Rn-219), thoron (Rn-220), and radon (Rn-222) decay series. The RVISLs are based on inhalation and submersion in gas cloud exposure routes for residential and commercial settings. The RVISLs are analogous to preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs), where the isotope-specific values are in units of activity concentration (activity per unit volume). If the concentration of a parent isotope of radon or its progeny is found to exceed the RVISL, then further action to ensure cleanup of the contaminant may be necessary. In residential and commercial settings, the RVISLs will vary based on the air exchange rate present. The EPA’s Radionuclide PRG and DCC Calculators also assess the risk/dose from noble gases in the air due to household use of water like showering. In this study, a computational method in MATLAB was developed to determine the impact of the air exchange rate on the activity equilibrium factor (A eq ) and the inhalation fractional equilibrium factor (F eq ). Both factors are values that reflect the equilibrium concentrations of progeny to their parent in the air. These factors have a direct impact on the RVISL, PRG, and DCC calculations of WL, ELCR, and annual dose, respectively. This study builds on a previous report that only focused on actinon, thoron, and radon by revisiting the original A eq and F eq calculation methods, as well as including the values for the Rn-207, Rn-209, Rn-210, Rn-211, Rn-215, Rn-216, Rn-217, Rn-218, Rn-223, Ne-24, Ar-42, Ar-43, Ar-44, Kr-74, Kr-75, Kr-76, Kr-77, Kr-88, Kr-89, Xe-120, Xe-121, Xe-122, Xe-123, Xe-135m, and Xe-138 decay chains, which are not currently available in literature. The EPA’s RVISL calculator will be updated to include the new A eq and F eq values for the actinon, thoron, and radon decay chains, while the rest of the calculators will incorporate all the new A eq and F eq values as appropriate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Spatio-temporal and weather characterization of road loads of electrified heavy-duty commercial vehicles across U.S. interstate roads

Adoption of battery electric vehicles (BEV) in heavy duty (HD) commercial freight transportation is difficult due to technological and economic hurdles. Beyond safety and compliance, fleet and operational logistics necessitate both high uptime and parity with diesel system productivity/Total Cost of Ownership to support widespread deployment of electric powertrains. However, relatively high energy storage costs, along with the higher weight of BEV systems, limit the viability of HD commercial freight transport to shorter-range applications where smaller batteries will serve for mission energy requirements (single operational shift). Knowing the energy consumption and operating variations of these commercial vehicle systems is crucial for effectively sizing the energy storage systems. This paper is the first in a series of studies to understand the regional specific operating design domain variations of commercial Class 8 HD trucks and the associated impact to their energy requirements. In particular, the local weather conditions are shown to influence the total vehicle energy usage. Further, the impact of temperature, pressure, and humidity changes are shown to impact the local air density. This is needed to calculate aerodynamic drag on vehicles and has been found to play a significant role in the overall performance of a vehicle. Although the methodology of calculating air density varies only slightly throughout the literature, the application to transportation has still been limited. This study provides a means by which air density can be estimated for the contiguous U.S. using the NOAA MADIS dataset. These air density estimates were then used to determine vehicle performance in varying regions of the country to highlight the importance of consideration of weather variables when monitoring vehicle performance, but also to provide recommendations based on these locales upon fleet conversion to BEVs.

Moore, Amy↗

Radiation Shielding Analysis of Linac Extension Area in APS Using FLUKA and PHITS Monte Carlo Radiation Transport Codes

The Linac extension area tunnel can accept 300- to 500-MeV electrons for experiments. Radiations from various normal and accident beam loss scenarios were analyzed with the FLUKA and PHITS Monte Carlo radiation transport codes. In normal beam loss scenarios, the beam was dumped on the horizontal and vertical beam dumps, while the accident scenarios were horizontal and vertical mis-steered beams that can occur due to incorrect beam energy and magnet settings. The extent of beam deviation, which was established using particle tracking studies, was used to define the beam directions in the Monte Carlo transport calculations. Further, a mis-steered condition, where the beam was not intercepted by the dumps, was also analyzed. For the horizontal dump, the PHITS results above the berm were higher for neutrons and somewhat lower for photons, compared to the FLUKA results. Comparison of the secondary particle yields from FLUKA and PHITS from an Al block with dimensions comparable to what was used in the beam dumps showed a 40% higher neutron yield and a 10% lower photon yield. Finally, to ensure compliance with Argonne National Laboratory's shielding policy, the design of the horizontal beam dump was modified, and additional shielding was recommended.

FLUKA↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of Inverter-Dependent Transmission Systems (PROTECT-IT)

This presentation highlights the overall objectives of the SETO funded protection project. The main technical approaches are also highlighted. This high impact project produces multiple innovative outcomes, including comprehensive impact study of how IBR affects protection elements, simplified low-order IBR model for protection engineers, enhanced and data-driven protection design, co-design concept for coordination protection and IBRs.

14 SOLAR ENERGY↗

Five Year Comparison of Mixing Height Determinations at the Savannah River Site

Air quality dispersion modeling is performed for the Savannah River Site (SRS) to demonstrate compliance with applicable regulations. The AMS/EPA Regulatory Model (AERMOD) modeling system is an EPA recommended model for air quality applications with a data preprocessor (AERMET) to incorporate meteorological data collected on site. AERMET parameterizes or calculates meteorological variables that are not directly measured onsite. One of the parameters estimated by AERMET is the atmospheric mixing height. While the mixing height is not currently a measurement input into AERMET, SRS has the capability to measure the local mixing height. The Savannah River National Laboratory (SRNL) operates a Vaisala CL31 Lidar Ceilometer which estimates mixing height from aerosol backscatter. This study compares the parameterized mixing height from AERMET to the ceilometer estimated mixing height for the current regulatory period at SRS incorporating data from 2015-2019. Results from this study showed the average daily minimum values (morning) from AERMET were an order of magnitude lower than the commonly used Holzworth (1972) method and the ceilometer estimated mixing heights. Additionally, on average, the ceilometer exhibited a daily maximum mixing height value that occurred 1-3 hours later than the AERMET estimated maximum. This difference is likely due to the nighttime atmospheric mixing height assumptions and calculations used by AERMET. The AERMET algorithm cuts off mixing height growth at sunset while the ceilometer data show ongoing evening convection typical of the southeastern United States. These results suggest that the AERMET parametrization scheme assumptions may not be representative of a forested landscape and evening convection which could account for more mixing overnight. The results obtained in this study are significant for air dispersion modeling applications for regulatory purposes and worker safety. Mixing height can impact model estimated pollutant concentrations. A greater mixing height will provide more volume for pollutant dispersion. This report documents efforts to quantify the dependence of mixing height inputs toward a conservative estimated pollutant concentration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Messaging for Impact: Behavioral Science-Based Communication Strategies to Advance Energy Efficiency

Currently, five legal authorities require U.S. federal agencies to purchase energy-efficient products. However, compliance with these requirements has consistently been low (~55%). Recent surveys indicate that energy efficiency requirements are not communicated properly within federal agencies and energy-efficiency is not a top priority. In the constantly evolving energy industry, with many solutions for a clean energy future, effective communication methods are vital for widespread adoption of energy efficiency. We have been conducting experiments within the U.S. federal sector that test the effectiveness of messaging strategies developed by using behavioral science principles like loss aversion, framing, and herd behavior. This will identify effective communications methods that encourage energy efficiency adoption. In this study, we measure the effectiveness of different communication strategies by monitoring the web traffic of hyperlinks placed within our digital communications and outreach materials. To determine effective strategies that influence federal buyer behavior, the web traffic from subjects that received the behavioral science-based messaging (treatment group) is compared to that from subjects that received regular messaging (control group) for each of the strategies. This paper provides an overview of the behavioral science principles that we applied, data collection methods, and results of our analysis. Since the lack of effective communication of energy-efficiency policies is also a common problem in the private sector, the messaging strategies developed in this study can be applicable to other large private sector institutions

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2020. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2020 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

Resource Conservation and Recovery Act↗

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory ↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2021

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2021. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2021 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of Gamma-irradiated Calcium Silicate Hydrates. Part II: Mechanical Properties

Mechanical properties of calcium silicate hydrates (C-S-H) with C/S ratios of 0.75, 1, and 1.33 were examined with nanoindentation after gamma-adsorbed doses of 0.145, 0.280, 0.500, and 0.784 MGy, and were compared with control samples. Young' s modulus and stress relaxation tests showed no apparent trend with irradiation dose. Qualitatively, most of the irradiated samples were found to relax more than their respective controls, but not always in a statistically significant manner. Most of the Young' s modulus irradiated–control pairs showed marginally higher stiffness in the irradiated samples, but overall trends with irradiation dose were not obvious. Creep compliance was obtained for the samples irradiated at the highest dose and their respective controls. Two of the three irradiated samples exhibited less creep than their respective controls, but only one of which was statistically significant. The lack of clear changes in mechanical properties for these samples correlates with separate chemical analyses that showed no loss of interlayer water by exposure to irradiation or changes in the mean silicate chain length. Further research evaluating higher doses (25 and 200 MGy) representative of those received by concrete structures in nuclear power plants at prolonged operation is being carried out to complement the present study.

36 MATERIALS SCIENCE↗

Impact of Selected High-Performance Fuel Blends on Three-Way Catalyst Light Off under Synthetic Spark-Ignition Engine-Exhaust Conditions

The U.S. Department of Energy funded Co-Optimization of Fuels and Engines initiative aims to simultaneously develop advanced engines along with high-performance fuels to reduce petroleum consumption. The engine exhaust of spark-ignited light-duty vehicles contains pollutants such as nitrogen oxides, carbon monoxide (CO), and non-methane organic gases. When operated above their “light-off” temperature, three-way catalysts (TWCs) efficiently control the emissions of these pollutants from the vehicle exhaust. However, below the catalyst light-off temperature, during cold start, the TWCs are not effective. Thus, the stringent environmental regulations necessitate cold-start compliance of advanced engines operating on novel fuels for commercialization. Exhaust composition strongly impacts the effectiveness of TWCs. Hence, ensuring that the high-performance fuels under consideration do not have detrimental effects on current emissions control technology is necessary. To mitigate cold-start emissions, a low light-off temperature of the fuel on the TWC is desirable. As real-world fuels are multicomponent blends, we conducted investigations into the light-off behavior of representative fuel mixtures on a three-mode redox-aged commercial TWC under synthetic engine-exhaust conditions. The high-performance fuels in this study included 10–30% volumetric levels of ethanol, isobutanol, diisobutylene, and an aromatic mixture. Each of these high-performance fuel components was mixed into a gasoline surrogate blendstock for oxygenate blending (BOB). Our results showed that aromatics and alkenes in the surrogate BOB inhibit low-temperature reactivity of alkanes, alcohols, and CO on the TWC and dominate the blend light-off behavior. All the high-performance fuel blends had a very similar light-off behavior to the surrogate gasoline BOB, indicating that blending up to 30% (by vol.) of high-performance blendstocks in a gasoline base fuel can potentially reduce greenhouse gas emissions through improved engine efficiency and petroleum displacement without jeopardizing the ability to meet emissions regulations. While some high-performance blendstocks demonstrated lower light-off temperatures than a surrogate gasoline blend, taking advantage of the higher catalytic reactivity of these blendstocks to reduce cold-start emissions would require reducing the aromatic content in petroleum-based market fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Battery Energy Storage System (BESS) End-of-Performance and Decommissioning Considerations [Slides]

This presentation provides a comprehensive overview of end-of-performance and decommissioning considerations for large-scale Battery Energy Storage Systems (BESS). It outlines expected system lifespans, midterm assessment needs, and pathways for extending operational life through augmentation or repowering. The presentation details regulatory requirements that govern decommissioning plans, cost estimates, financial assurance mechanisms, and performance obligations across multiple jurisdictions. It further examines end-of-life equipment management, including recycling, waste handling, transportation, and environmental compliance. Designed to support Malawi's electricity-sector institutions, the presentation highlights how planning for decommissioning and environmental stewardship can be integrated early in project development to ensure safe, financially accountable, and environmentally responsible BESS system retirement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon Capture and Storage for Small-to-Medium Biorefineries: Promising Carbon Removal Solution with Economic Challenges

Carbon capture and storage (CCS) integrated with biomass-based fuel production can provide cost-effective biomass carbon removal and storage (BiCRS) and produce high-value bioproducts, such as sustainable aviation fuels. To accelerate BiCRS deployment, it is crucial to quantify the costs of CCS integration, particularly for small- and medium-scale biorefineries that are representative of early-stage deployment. Existing studies tend to focus on plant sizes that are orders-of-magnitude larger than early-stage installations, possibly underestimating CCS costs for small-to-medium biorefineries. We show that the capture, transport, and storage costs to maximize CO 2 removal from a 526 dry tonne per day (tpd) biomass gasification plant (largest existing size) could be 13–47% higher than costs for a typical modeled plant size (2000 dry tpd). The higher cost estimates are driven by less favorable economies of scale and realistic assumptions about the availability of affordable CO 2 transport infrastructure with both drivers broadly applicable to other BiCRS technologies. Compliance and voluntary carbon markets could incentivize biorefinery CCS, but both carry a high degree of uncertainty. In conclusion, these findings highlight that sufficient and reliable financial mechanisms would be essential to unlocking the full CO 2 removal potential of biorefineries and facilitating BiCRS scale-up.

Biological transport↗

Integrating the Safety Evaluation for a Molten Salt Reactor Operation and Fuel Cycle Facility Application

Molten salt reactor (MSR) sites may include additional elements of the nuclear fuel cycle beyond those of the existing fleet. In the existing fleet, the individual elements of the fuel cycle typically have been located on different sites and licensed separately. Providing robust separation between hazards remains a useful safety practice for MSRs. Although the different elements of the fuel cycle at a nuclear site that includes MSRs may transfer material between processes more frequently than prior practices, providing adequate separation between distinct facilities avoids the potential for adverse interactions. Additionally, some elements of the MSR fuel cycle, such as fuel salt preparation or waste stabilization, may be more efficient to share among multiple nearby reactors, and nuclear sites that include MSRs may also include other reactor classes. Hence, discrete MSR fuel cycle facilities located at a common site could be physically separated with robust barriers—albeit potentially connected by piping—and licensed individually. This report describes the hazards of individual elements of representative MSR fuel cycle facilities, including their relationship to overall site level hazards. The report maps the regulatory compliance aspects of the individual MSR fuel cycle elements (e.g., fuel salt preparation, reactor, waste stabilization) to existing and developing regulations, as well as describes current and developing site-level regulations from an MSR perspective.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved Modeling of Waste Isolation Pilot Plant Disposal Room Porosity

Disposal rooms at the Waste Isolation Pilot Plant (WIPP) contain waste and gas, and their porosity evolves over time. This report presents several improvements to the disposal room porosity model and presents new porosity predictions for use in future WIPP Performance Assessment activities. The improvements pertain to three sub-models: the geomechanical model, the waste compaction model, and the gas pressurization model. The impacts of each major improvement were quantified and the new porosity predictions were shown to be both mesh and domain size converged. Also, sensitivity studies on the disposal room horizon, clay seam friction coefficients, and homogenized waste representation were performed to support assumptions in the disposal room porosity model. To compare the legacy and new porosity predictions, the simulation results were plotted as a response surface, where gas pressure and time are inputs and porosity is the output. The new porosity response surface is insensitive to pressures beneath lithostatic pressure and highly sensitive to pressures above lithostatic pressure. The legacy porosity response surface, on the other hand, has moderate porosity gradients over all pressures. The new porosity response surface has a stronger scientific foundation than the legacy surface and may now be used for Compliance Decision Analyses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗