Preliminary Results of an Altitude-Wind-Tunnel Investigation of a TG-100A Gas Turbine-Propeller Engine: Compressor and Turbine Performance Characteristics - 4

As part of an investigation of the performance and operational characteristics of the TG-100A gas turbine-propeller engine, conducted in the Cleveland altitude wind tunnel, the performance characteristics of the compressor and the turbine were obtained. The data presented were obtained at a compressor-inlet ram-pressure ratio of 1.00 for altitudes from 5000 to 35,000 feet, engine speeds from 8000 to 13,000 rpm, and turbine-inlet temperatures from 1400 to 2100R. The highest compressor pressure ratio was 6.15 at a corrected air flow of 23.7 pounds per second and a corrected turbine-inlet temperature of 2475R. Peak adiabatic compressor efficiencies of about 77 percent were obtained near the value of corrected air flow corresponding to a corrected engine speed of 13,000 rpm. This maximum efficiency may be somewhat low, however, because of dirt accumulations on the compressor blades. A maximum adiabatic turbine efficiency of 81.5 percent was obtained at rated engine speed for all altitudes and turbine-inlet temperatures investigated.

Wallner, Lewis E.↗

Preliminary Results of an Altitude-Wind-Tunnel Investigation of an Axial-Flow Gas Turbine-Propeller Engine: Compressor and Turbine Performance Characteristics - 4

As part of an investigation of the performance and operational characteristics of the axial-flow gas turbine-propeller engine, conducted in the Cleveland altitude wind tunnel, the performance characteristics of the compressor and the turbine were obtained. The data presented were obtained at a compressor-inlet ram-pressure ratio of 1.00 for altitudes from 5000 to 35,000 feet, engine speeds from 8000 to 13,000 rpm, and turbine-inlet temperatures from 1400 to 2100 R. The highest compressor pressure ratio obtained was 6.15 at a corrected air flow of 23.7 pounds per second and a corrected turbine-inlet temperature of 2475 R. Peak adiabatic compressor efficiencies of about 77 percent were obtained near the value of corrected air flow corresponding to a corrected engine speed of 13,000 rpm. This maximum efficiency may be somewhat low, however, because of dirt accumulations on the compressor blades. A maximum adiabatic turbine efficiency of 81.5 percent was obtained at rated engine speed for all altitudes and turbine-inlet temperatures investigated.

Wallner, Lewis E.↗

Task IV: Development of Circumferential Inlet Distortion through a Representative Eleven Stage High-speed Axial Compressor

The concepts and the procedure developed in Task I and Task III were used to determine the response of an eleven-stage high-speed compressor to an inlet distortion of 180 deg. circumferential extent for contrasting against its performance under uniform inlet flow. Using the computed results at the inlet to and outlet of the compressor, the computed total pressure ratio and efficiency for the clean condition are determined to be 14.22 and 76.9 percent respectively. As for the distorted case, these are determined to be 10.35 and 71.8 percent respectively, showing deterioration 76.9 percent vs 71.8 percent). The physical consistency of the computed flow field was assessed as a means of demonstrating the applicability and utility of the body force representation for inlet distortion computations. Specifically the computed evolution of the distorted pattern in static pressure and total pressure from compressor inlet to exit is examined. For the eleven-stage compressor examined here, the deterioration in performance has been found to be particularly severe in the last 2 stages. This suggests that the last two stages could be redesigned to alleviate the observed deterioration thus making the compressor performance insensitive to circumferential inlet distortion. This can potentially be accomplished by first determining what should the body force distribution of the last two stages should be to achieve minimal or no deterioration in performance in the last two stages. One can then in principle proceed to determine the blade design to yield such a body force distribution.

Tan, Choon-Sooi↗

Task I: A Computational Model for Short Wavelength Stall Inception and Development In Multi-Stage Compressors

A computational model is presented for simulating axial compressor stall inception and development via disturbances with length scales on the order of several (typically about three) blade pitches. The model was designed for multi-stage compressors in which stall is initiated by these short wavelength disturbances, also referred to as spikes. The inception process described is fundamentally nonlinear, in contrast to the essentially linear behavior seen in so-called modal stall inception . The model was able to capture the following experimentally observed phenomena: (1) development of rotating stall via short wavelength disturbances, (2) formation and evolution of localized short wavelength stall cells in the first stage of a mismatched compressor, (3) the switch from long to short wavelength stall inception resulting from the re-staggering of the inlet guide vane, (4) the occurrence of rotating stall inception on the negatively sloped portion of the compressor characteristic. Parametric investigations indicated that (1) short wavelength disturbances were supported by the rotor blade row, (2) the disturbance strength was attenuated within the stators, and (3) the reduction of inter-blade row gaps can suppress the growth of short wavelength disturbances. It is argued that each local component group (rotor plus neighboring stators) has its own instability point (i.e. conditions at which disturbances are sustained) for short wavelength disturbances, with the instability point for the compressor set by the most unstable component group.

Suder, Kenneth↗

Temperature Swing Adsorption Compressor Development

Closing the oxygen loop in an air revitalization system based on four-bed molecular sieve and Sabatier reactor technology requires a vacuum pump-compressor that can take the low-pressure CO, from the 4BMS and compress and store for use by a Sabatier reactor. NASA Ames Research Center proposed a solid-state temperature-swing adsorption (TSA) compressor that appears to meet performance requirements, be quiet and reliable, and consume less power than a comparable mechanical compressor/accumulator combination. Under this task, TSA compressor technology is being advanced through development of a complete prototype system. A liquid-cooled TSA compressor has been partially tested, and the rest of the system is being fabricated. An air-cooled TSA compressor is also being designed.

Finn, John E.↗

Performance of the 19XB 10-Stage Axial-Flow Compressor

The 19xB compressor, which replaces the 19B coaapreseor and has the same length and diameter 88 the 19B compressor, was designed with 10 stages to deliver 30 pounds of air per second for a pressure ratio of 4.17 at an equivalent speed of 17,000 rpm; the 19B was designed with six stages for a pressure ratio of 2.7 at the same weight flow and speed as the 19XB compressor. The performance characteristics of the new compressor were determined at the NACA Cleveland laboratory at the request of the Bureau of Aeronautics, Navy Department. Results are presented of the investigation made to evaluate the over-all performance of the compressor, the effects of possible leakage past the rotor rear air seal, the effects of inserting instruments in each row of stator blades and in the first row of outlet guide vanes, and the effects of changing the temperature and the pressure of the inlet air. The results of the interstage surveys are also presented.

Downing, Richard M.↗

Experimental Investigation of Centrifugal Compressor Stabilization Techniques

Results from a series of experiments to investigate techniques for extending the stable flow range of a centrifugal compressor are reported. The research was conducted in a high-speed centrifugal compressor at the NASA Glenn Research Center. The stabilizing effect of steadily flowing air-streams injected into the vaneless region of a vane-island diffuser through the shroud surface is described. Parametric variations of injection angle, injection flow rate, number of injectors, injector spacing, and injection versus bleed were investigated for a range of impeller speeds and tip clearances. Both the compressor discharge and an external source were used for the injection air supply. The stabilizing effect of flow obstructions created by tubes that were inserted into the diffuser vaneless space through the shroud was also investigated. Tube immersion into the vaneless space was varied in the flow obstruction experiments. Results from testing done at impeller design speed and tip clearance are presented. Surge margin improved by 1.7 points using injection air that was supplied from within the compressor. Externally supplied injection air was used to return the compressor to stable operation after being throttled into surge. The tubes, which were capped to prevent mass flux, provided 9.3 points of additional surge margin over the baseline surge margin of 11.7 points.

Skoch, Gary J.↗

Performance of J-33-A-21 and J-33-A-23 Compressors with and without Water Injection

In an investigation of the J-33-A-21 and the J-33-A-23 compressors with and without water injection, it was discovered that the compressors reacted differently to water injection although they were physically similar. An analysis of the effect of water injection on compressor performance and the consequent effect on matching of the compressor and turbine components in the turbojet engine was made. The analysis of component matching is based on a turbine flow function defined as the product of the equivalent weight flow and the reciprocal of the compressor pressure ratio.

Beede, William L.↗

Unsteady Velocity Measurements in the NASA Research Low Speed Axial Compressor: Smooth Wall Configuration

The report is a collection of experimental unsteady data acquired in the first stage of the NASA Low Speed Axial Compressor in configuration with smooth (solid) wall treatment over the first rotor. The aim of the report is to present a reliable experimental data base that can be used for analysis of the compressor flow behavior, and hopefully help with further improvements of compressor CFD codes. All data analysis is strictly restricted to verification of reliability of the experimental data reported. The report is divided into six main sections. First two sections cover the low speed axial compressor, the basic instrumentation, and the in-house developed methodology of unsteady velocity measurements using a thermo-anemometric split-fiber probe. The next two sections contain experimental data presented as averaged radial distributions for three compressor operation conditions, including the distribution of the total temperature rise over the first rotor, and ensemble averages of unsteady flow data based on a rotor blade passage period. Ensemble averages based on the rotor revolution period, and spectral analysis of unsteady flow parameters are presented in the last two sections. The report is completed with two appendices where performance and dynamic response of thermo-anemometric probes is discussed.

Lepicovsky, Jan↗

Performance of J-33-A-21 Turbojet-Engine Compressor I - Over-All Performance Characteristics at Equivalent Impeller Speeds from 6000 to 13,400 RPM

The NACA is investigating a series of J-33 turbojet-engine compressors to determine the over-all and component performances and to improve theories of flow through large centrifugal compressors, The production model J-33-A-21 was operated over a range of inlet temperatures from 80 to -40 F and inlet pressures from 14 to 5 inches mercury absolute for equivalent impeller speeds from 6000 to 13,400 rpm. At the equivalent design speed of 11,500 rpm, the compressor had a peak pressure ratio of 3.98 at an equivalent weight flow of 73.4 pounds per second and an adiabatic temperature-rise , efficiency of 0.701. When the compressor speed was reduced from the design speed to 6000 rpm, the adiabatic temperature-rise efficiency increased to 0.747. At the maximum equivalent speed investigated (13,400 rpm), a peak pressure ratio of 5.09 was obtained at an adiabatic temperature-rise efficiency of 0.617 and an equivalent weight flow of 66.O pounds per second. An increase in inlet pressure from 5.5 to 14 inches mercury absolute, with a consequent increase in Reynolds number index, improved the pressure ratio but had no apparent effect on the ratio of temperature rise through the compressor to inlet temperature. The variation of the peak adiabatic temperature-rise efficiency with inlet pressure is in the direction that would be expected from a Reynolds number effect. Decrease in the inlet temperature from 80 to -40 F, with a consequent increase in Reynolds number index, resulted in scatter of the pressure-ratio data and increased values of temperature ratio. The variation of the adiabatic temperature-rise efficiency with inlet temperature is probably the result of heat-transfer effects and scatter in the pressure ratio.

Beede, William L.↗

Effect of Various Blade Modifications on Performance of a 16-Stage Axial-Flow Compressor. II - Effect on Over-All Performance Characteristics of Increasing Twelfth through Fifteenth Stage Stator-Blade Angles 3 deg

The stator-blade angles in the twelfth through fifteenth stages of a 16-stage axial-flow compressor were increased 3O. The over-all performance of this modified compressor is compared to the performance of the compressor with original blade angles. The matching characteristics of the modified compressor and a two-stage turbine were obtained and compared to those of the compressor with original blade angles and the same turbine.

Hatch, James E.↗

Performance of the 19XB 10-Stage Axial-Flow Compressor with Altered Blade Angles

Previous performance data of the 19XB axial-flow compressor indicated that the outlet guide vanes and possibly the inlet guide vanes were stalling. Calculations were made to determine if these adverse conditions could be eliminated and if the manufacturer's design specifications could be more nearly approached by altering the blade angles of the first few compression stages as well as the outlet guide vanes. With the blade angles altered, experimental data were taken at compressor speeds of 8500 to 17,000 rpm with inlet-air conditions of 7.4 inches of mercury absolute and 59 0 F. The temperature-rise efficiency increased with speed from 0.70 at 8500 rpm to 0.74 at 13,600 rpm and dropped gradually to 0.70 at 17,000 rpm. At the design speed of 17,000 rpm, the pressure ratio at the peak efficiency point was 3.63. The maximum pressure ratio at design speed was 4.15 at an equivalent weight flow of 29.8 pounds per second. The altered compressor operated very .near the design specifications of pressure ratio and equivalent weight flow. At the high speeds, the peak adiabatic temperature-rise efficiency was increased 0.02 to 0,06 by altering the blade angles. The peak pressure ratio was increased 0.29 at design speed (17,000 rpm) and 0.05 and 0.13 at 11,900 and 13,600 rpm, respectively. The equivalent weight flow through the altered compressor was reduced 2 pounds per second at 15,300 and 17,000 rpm, as was expected from the design calculations. As extreme caution was taken not to surge the compressor violently, the point of minimum air flow may not have been reached in the present investigation and in a previous investigation. A true comparison of the pressure ratios obtained at the high speeds therefore cannot be made.

Downing, Richard M.↗

Investigation of Unsteady Flow Behavior in Transonic Compressor Rotors with LES and PIV Measurements

In the present study, unsteady flow behavior in a modern transonic axial compressor rotor is studied in detail with large eddy simulation (LES) and particle image velocimetry (PIV). The main purpose of the study is to advance the current understanding of the flow field near the blade tip in an axial transonic compressor rotor near the stall and peak-efficiency conditions. Flow interaction between the tip leakage vortex and the passage shock is inherently unsteady in a transonic compressor. Casing-mounted unsteady pressure transducers have been widely applied to investigate steady and unsteady flow behavior near the casing. Although many aspects of flow have been revealed, flow structures below the casing cannot be studied with casing-mounted pressure transducers. In the present study, unsteady velocity fields are measured with a PIV system and the measured unsteady flow fields are compared with LES simulations. The currently applied PIV measurements indicate that the flow near the tip region is not steady even at the design condition. This self-induced unsteadiness increases significantly as the compressor rotor operates near the stall condition. Measured data from PIV show that the tip clearance vortex oscillates substantially near stall. The calculated unsteady characteristics of the flow from LES agree well with the PIV measurements. Calculated unsteady flow fields show that the formation of the tip clearance vortex is intermittent and the concept of vortex breakdown from steady flow analysis does not seem to apply in the current flow field. Fluid with low momentum near the pressure side of the blade close to the leading edge periodically spills over into the adjacent blade passage. The present study indicates that stall inception is heavily dependent on unsteady behavior of the flow field near the leading edge of the blade tip section for the present transonic compressor rotor.

Hah, Chunill↗

Axial flow positive displacement worm compressor

An axial flow positive displacement compressor has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first and second sections of a compressor assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first and second twist slopes in the first and second sections respectively. The first twist slopes are less than the second twist slopes. An engine including the compressor has in downstream serial flow relationship from the compressor a combustor and a high pressure turbine drivingly connected to the compressor by a high pressure shaft.

Murrow, Kurt David↗

Analyses of the Integration of Carbon Dioxide Removal Assembly, Compressor, Accumulator and Sabatier Carbon Dioxide Reduction Assembly

A tool has been developed by the Sabatier Team for analyzing/optimizing CO2 removal assembly, CO2 compressor size, its operation logic, water generation from Sabatier, utilization of CO2 from crew metabolic output, and Hz from oxygen generation assembly. Tests had been conducted using CDRA/Simulation compressor set-up at MSFC in 2003. Analysis of test data has validated CO2 desorption rate profile, CO2 compressor performance, CO2 recovery and CO2 vacuum vent in CDRA desorption. Optimizing the compressor size and compressor operation logic for an integrated closed air revitalization system Is being conducted by the Sabatier Team.

Jeng, Frank F.↗

Toward Optimum Configuration of Circumferential Groove Casing Treatment in Transonic Compressor Rotors

The current paper first reviews experimental and numerical investigations to understand flow physics and to develop optimum configurations of circumferential grooves in compressor rotors. Circumferential grooves are used mainly to increase stall margin in axial compressors with small decrease in aerodynamic efficiency. Although circumferential groove casing treatment has been used widely, flow mechanisms of the circumferential grooves at near stall conditions are not well understood yet. Detailed time-dependent flow measurement inside tip gap in a high speed compressor is still a big challenge even though significant advance has been made in non-intrusive flow measurement technique. Therefore numerical approaches have been used to study relevant flow physics. However, optimum design of circumferential grooves to a given compressor with the computational tools is not practical yet. In the present paper, various investigations to study flow physics of circumferential groove casing treatment in axial compressor are reviewed first. Possible missing flow physics are identified and future research efforts for the optimum design are discussed.

Hah, Chunill↗

Study of Convective Flow Effects in Endwall Casing Treatments in Transonic Compressor Rotors

The unsteady convective flow effects in a transonic compressor rotor with a circumferential-groove casing treatment are investigated in this paper. Experimental results show that the circumferential-groove casing treatment increases the compressor stall margin by almost 50% for the current transonic compressor rotor. Steady flow simulation of the current casing treatment, however, yields only a 15% gain in stall margin. The flow field at near-stall operation is highly unsteady due to several self-induced flow phenomena. These include shock oscillation, vortex shedding at the trailing edge, and interaction between the passage shock and the tip clearance vortex. The primary focus of the current investigation is to assess the effects of flow unsteadiness and unsteady flow convection on the circumferential-groove casing treatment. Unsteady Reynolds-averaged Navier-Stokes (URANS) and Large Eddy Simulation (LES) techniques were applied in addition to steady Reynolds-averaged Navier-Stokes (RANS) to simulate the flow field at near-stall operation and to determine changes in stall margin. The current investigation reveals that unsteady flow effects are as important as steady flow effects on the performance of the circumferential grooves casing treatment in extending the stall margin of the current transonic compressor rotor. The primary unsteady flow mechanism is unsteady flow injection from the grooves into the main flow near the casing. Flows moving into and out of the grooves are caused due to local pressure difference near the grooves. As the pressure field becomes transient due to self-induced flow oscillation, flow injection from the grooves also becomes unsteady. The unsteady flow simulation shows that this unsteady flow injection from the grooves is substantial and contributes significantly to extending the compressor stall margin. Unsteady flows into and out of the grooves have as large a role as steady flows in the circumferential grooves. While the circumferential-groove casing treatment seems to be a steady flow device, unsteady flow effects should be included to accurately assess its performance as the flow is transient at near-stall operation.

Hah, Chunill↗

Establishing a Ballistic Test Methodology for Documenting the Containment Capability of Small Gas Turbine Engine Compressors

A test methodology currently employed for large engines was extended to quantify the ballistic containment capability of a small turboshaft engine compressor case. The approach involved impacting the inside of a compressor case with a compressor blade. A gas gun propelled the blade into the case at energy levels representative of failed compressor blades. The test target was a full compressor case. The aft flange was rigidly attached to a test stand and the forward flange was attached to a main frame to provide accurate boundary conditions. A window machined in the case allowed the projectile to pass through and impact the case wall from the inside with the orientation, direction and speed that would occur in a blade-out event. High-peed, digital-video cameras provided accurate velocity and orientation data. Calibrated cameras and digital image correlation software generated full field displacement and strain information at the back side of the impact point.

Heady, Joel↗