Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminant Diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Inversion layer solar cell fabrication and evaluation

Silicon solar cells operating with induced junctions rather than diffused junctions have been fabricated and tested. Induced junctions were created by forming an inversion layer near the surface of the silicon by supplying a sheet of positive charge above the surface. This charged layer was supplied through three mechanisms: (1) applying a positive potential to a transparent electrode separated from the silicon surface by a dielectric, (2) contaminating the oxide layer with positive ions, and (3) forming donor surface states that leave a positive charge on the surface. A movable semi-infinite shadow delineated the extent of sensitivity of the cell due to the inversion region. Measurements of the response of the inversion layer cell to light of different wavelengths indicated it to be more sensitive to the shorter wavelengths of the sun's spectrum than conventional cells. The greater sensitivity occurs because of the shallow junction and the strong electric field at the surface.

Call, R. L.↗

Interaction of an oscillating vortex with a turbulent boundary layer

An oscillating vortex embedded within a turbulent boundary layer was generated experimentally by forcing a periodic lateral translation of a half-delta wing vortex generator. The objective of the experiment was to investigate the possibility that a natural oscillation, or meander, might be responsible for flattened vortex cores observed in previous work, which could also have contaminated previous turbulence measurements. The effect of this forced oscillation was characterized by comparison of measurements of the mean velocities and Reynolds stresses at two streamwise stations, for cases with and without forcing. The Reynolds stresses were affected significantly by the forced oscillation, mainly through contributions from the individual production terms, provided that the vortex was not too diffuse.

Westphal, R. V.↗

Investigation of titanium-nitride layers for solar-cell contacts

Reactively sputtered titanium-nitride layers have been incorporated as diffusion barriers in a titanium-silver metallization scheme on silicon. Backscattering analysis (2-MeV He/+/, RBS) indicates that the integrity of the system is basically preserved during annealing at 600 C for 10 min. Electrical properties were determined for titanium-nitride layers prepared under different deposition conditions. Resistivity and Hall mobility appear to depend on the oxygen contamination of the deposited material. For the lowest oxygen concentration (less than 5 at %) a resistivity of 170 microohms/cm has been found.

Von Seefeld, H.↗

Magnetically Diffused Radial Electric-Arc Air Heater Employing Water-Cooled Copper Electrodes

A magnetically rotated electric-arc air heater has been developed that is novel in that an intense magnetic field of the order of 10,000 to 25,000 gauss is employed. This field is supplied by a coil that is connected in series with the arc. Experimentation with this heater has shown that the presence of an intense magnetic field transverse to the arc results in diffusion of the arc and that the arc has a positive effective resistance. With the field coil in series with the arc, highly stable arc operation is obtained from a battery power supply. External ballast is not required to stabilize the arc when it is operating at maximum power level. The electrode erosion rate is so low that the airstream contamination is no more than 0.07 percent and may be substantially less.

COPPER↗

Degradation of optical components in space

This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.

Blue, M. D.↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

Simplified Vicarious Radiometric Calibration

A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform ground target areas having different reflectance values. The target areas can be natural or artificial and must be large enough to minimize adjacent-pixel contamination effects. The radiative coupling between the atmosphere and the terrain needs to be approximately the same for the two targets. This condition can be met for relatively uniform backgrounds when the distance between the targets is within a few hundred meters. For each target area, the radiance leaving the ground in the direction of the satellite is measured with a radiometrically calibrated spectroradiometer. Using the radiance measurements from the two targets, atmospheric adjacency and atmospheric scattering effects can be subtracted, thereby eliminating many assumptions about the atmosphere and the radiative interaction between the atmosphere and the terrain. In addition, the radiometrically calibrated spectroradiometer can be used with a known reflectance target to estimate atmospheric transmission and diffuse- to-global ratios without the need for ancillary sun photometers. Several comparisons between the simplified method and traditional techniques were found to agree within a few percent. Hence, the simplified method reduces the overall complexity of performing vicarious calibrations and can serve as a method for validating traditional radiative transfer models

Stanley, Thomas↗

Ultrasonic Inspection During Autoclave Cure of Reflowable-Interface Composite Joints

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making the interface susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures due to uncertainty in bond performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process that can eliminate the material discontinuity at the interface. Implementing in-situ process monitoring enables assessing the bond quality during processing rather than waiting for post-fabrication mechanical testing to be completed. In this paper, an in-situ ultrasonic inspection system is used to monitor the joining of three composite laminates assembled using the AERoBOND technique. For each panel, the amplitude of the wave reflection at the joint was measured throughout the cure cycle. The results indicate the timing and extent of reflow and cure of the epoxy resin at the joint. Factors indicating end of cure were ascertained and a metric was developed to qualitatively predict acceptable mode-II fracture toughness based on the ultrasonic amplitude at the joint line during cure. In addition, since the inspection system scans an area of the joint, high-resolution localized results can be obtained across the joint.

Tyler B Hudson↗

Impurity effects in silicon for high efficiency solar cells

Model analyses indicate that sophisticated solar cell designs including, e.g., back surface fields, optical reflectors, surface passivation, and double layer antireflective coatings can produce devices with conversion efficiencies above 20 percent (AM1). To realize this potential, the quality of the silicon from which the cells are made must be improved; and these excellent electrical properties must be maintained during device processing. As the cell efficiency rises, the sensitivity to trace contaminants also increases. For example, the threshold Ti impurity concentration at which cell performance degrades is more than an order of magnitude lower for an 18-percent cell. Similar behavior occurs for numerous other metal species which introduce deep level traps that stimulate the recombination of photogenerated carriers in silicon. Purification via crystal growth in conjunction with gettering steps to preserve the large diffusion length of the as-grown material can lead to the production of devices with efficiencies aboved 18 percent, as has been verified experimentally.

Hopkins, R. H.↗

Chemical and Thermodynamic Constraints on the Thermal Evolution of Eucrites

Vesta is the only differentiated asteroid with a nearly intact crust, making it the candidate for studying early planetary differentiation. It is commonly thought that the howardite, eucrite, and diogenite (HED) clan of meteorites derive from Vesta, and thus the study of HEDs is important for understanding the evolution of primitive bodies in the early solar system [1]. Of particular interest are the unusual trace element abundances in Stannern group eucrites, which have been interpreted as partial melting and melt contamination events that occurred on the parent body during thermal metamorphism[2]. However, some samples that contain evidence of high temperature metamorphism, such as Elephant Moraine (EET) 90020, have anomalous REE patterns that have been interpret-ed multiple ways. For example [3] concluded that the loss of small degrees of partial melt depleted the sample in LREEs while [4] concluded that subsolidus diffusion better explained why depletion of only some highly incompatible elements is observed. The heterogeneous nature of this sample makes reconstructing its petrologic history challenging. Here, we conduct further petrographic and chemical studies on polished thin sections of EET 90020 and compare results to previous studies [3-5]. Additionally, we combine chemical analyses with thermodynamic models in order to refine the constraints on the post-crystallization thermal history of EET 90020. We additionally include studies of Graves Nunataks (GRA) 98098, which also contains evidence of high temperature metamorphism and anomalous geochemical signatures, as well as evidence of solid state diffusion at lower temperatures [6].

Gorce, Jennifer S.↗

Monolithic short wave infrared (SWIR) detector array

A monolithic self-scanned linear detector array was developed for remote sensing in the 1.1- 2.4-micron spectral region. A high-density IRCCD test chip was fabricated to verify new design approaches required for the detector array. The driving factors in the Schottky barrier IRCCD (Pdsub2Si) process development are the attainment of detector yield, uniformity, adequate quantum efficiency, and lowest possible dark current consistent with radiometric accuracy. A dual-band module was designed that consists of two linear detector arrays. The sensor architecture places the floating diffusion output structure in the middle of the chip, away from the butt edges. A focal plane package was conceptualized and includes a polycrystalline silicon substrate carrying a two-layer, thick-film interconnecting conductor pattern and five epoxy-mounted modules. A polycrystalline silicon cover encloses the modules and bond wires, and serves as a radiation and EMI shield, thermal conductor, and contamination seal.

Source record↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures to alleviate the inability to certify bonded performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This paper describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection method with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

PACE OCI Straylight and Crosstalk Evaluation using Moon

The Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has performed three monthly lunar calibrations. The moon is an extended source over a large dark background, making it an ideal target for evaluating OCI’s straylight and crosstalk performance. The lunar data analysis showed the straylight and crosstalk to be lower than the prelaunch measurements, especially in the along-track direction, where very little straylight is detected. Based on lunar data, the prelaunch measured crosstalk coefficients were reduced, and a crosstalk correction was tested on both lunar and solar calibration data. Applying the revised crosstalk correction, the crosstalk contaminations are significantly reduced to under 0.1% at 2-3 pixels away from the lunar boundary for bands above 350 nm. Below 350 nm, the crosstalk correction residuals gradually increase due to a lack of high-quality prelaunch measurements. Lastly, applying the crosstalk correction changes the calibrated radiance for all science data. This is due to the different spectral shapes between the solar diffuser and the observed scenes. For the moon, the crosstalk correction has an impact of ~0.4% on the overall calibrated radiance for the 400 – 600 nm bands and up to 20% impact on the UV bands.

Shihyan Lee↗

Effects of impurities on silicon solar-cell performance

Model analyses indicate that sophisticated solar cell designs (back surface fields, optical reflectors, surface passivation, and double layer antireflective coatings) can produce devices with conversion efficiencies above 20%. To realize this potential, the quality of the silicon from which the cells are made must be improved; and these excellent electrical properties must be maintained during device processing. As the cell efficiency rises, the sensitivity to trace contaminants also increases. For example, the threshold Ti impurity concentraion at which cell performance degrades is more than an order of magnitude lower for an 18% cell than for a 16% cell. Similar behavior occurs for numerous other metal species which introduce deep level traps that stimulate the recombination of photogenerated carriers in silicon. Purification via crystal growth in conjunction with gettering steps to preserve the large diffusion length of the as grown material can lead to the production of devices with efficiencies above 18%, as verified experimentally.

Hopkins, R. H.↗

Fabry-Perot ground-based observations of comets and the Jupiter plasma torus

The Wisconsin 150 mm dual etalon Fabry-Perot spectrometer is a powerful instrument for the study of diffuse emission sources such as cometary atmospheres, the Jupiter plasma torus, and various emission nebulae. Since 1985, researchers have concentrated their efforts on extensive observations of Comet Halley and the analysis of the data. Images of Comet Halley in (OI)6300 Angstrom emission were analyzed to obtain the spatial distribution of O(1D) in the cometary atmosphere. The narrow spectral bandpass of the Fabry-Perot (0.2 Angstrom) eliminated contamination from terrestrial airglow (OI)6300 and cometary NH2 lines in the nearby spectrum. The results were modelled to provide photodestruction lifetimes of cometary Water abd OH, the predominant parents of O(1D). The Fabry-Perot was also used in the scanning mode to obtain measurements of (OI)6300 and Balmer alpha emissions which were used to determine the H, O(1D) and water production rates as a function of heliocentric distance, both pre-perihelion and post-perihelion. Researchers also analyzed high resolution spectra of the NH2 (0,8,0) band in the 6300 Angstrom region to obtain preliminary values of the NH2 production rate. Assuming NH3 is the major parent of NH2, researchers found that the abundance ratio NH3/water is about (0.12 plus or minus 0.04 percent), assuming thermal equilibrium for the level populations of NH2.

Scherb, Frank↗

Recent results from the InP homojunction cell module on the LIPS III spacecraft

The flight performance of the NASA Lewis Research Center's indium phosphide homojunction cell module on the LIPs III spacecraft is presented. Four n+-p diffused junction cells, an early product of an InP development program, were flown. The voltage range of the data prohibits determination of the open-circuit voltage or the maximum power point. However, analysis of the 32 months of short-circuit current data reveals a slight increase, not the 4 percent decrease expected from radiation tolerance studies. This increase may be due to continual cleaning of possible prelaunch dust contamination or changes in data acquisition system calibration. For all cells, the average short-circuit current remains below prelaunch values.

Brinker, David J.↗

Analysis prcedures for ROSAT XRT/PSPC observations of extended objects and the diffuse background

Proper reduction of ROSAT observations of extended sources or the diffuse background requires techniques that are quite different from the standard point-source analysis. We describe in detail an appropriate set of procedures for this purpose for the X-ray Telescope (XRT), Position Sensitive Proportional Counter (PSPC). We define a standard set of pulse-height bands recommended for analyzing extended structure and describe the use of detector efficiency maps for proper flat-fielding of images. Sources of noncosmic background contamination and their modeling and subtraction are discussed and demonstrated. IDL routines for implementing these data reduction procedures are being made available to the community through the ROSAT IDL library maintained at Goddard Space Flight Center (GSFC).

Snowden, S. L.↗