Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Minority Report Submitted as an Addendum to the Report of the Mars 2020 Organic Contamination Panel

This Minority Report (MR) presents seven findings in addition to or contrary to the main OCP report: 1. Contamination control for the Mars 2020 cache must be strict. Mars’ surface is known to be organics-poor from laboratory studies, Mars meteorite analyses, and from four previous NASA missions. It is imperative that contamination control measures are enacted that enable reliable and robust detection of potential biomarker compounds at the ppb level. 2. Since Mars 2020 is a sample return mission and analyses of samples in the returnable cache are expected to occur after return to Earth, positive controls are not recommended for flight on Mars 2020 unless a compelling case can be made for their use. 3. The findings of previous panels dedicated to organic compound analysis in Martian samples (OCSSG, ND-SAG, SDT) recommend TOC limits between 10-40 ppb. The MR finds that the lower limit of 10 ppb is recommended and that insufficient justification is given by the OCP Panel Report (PR) to raise the TOC limit to 40 ppb. 4. Analytical capability is sufficiently advanced that analytical capability is an irrelevant consideration with respect to differentiating between 10 and 40 ppb TOC. 5. Perceived contamination control challenges are an irrelevant consideration for raising the TOC contamination limit from 10 to 40 ppb since those challenges, and the procedures to ameliorate them, will exist regardless of whether the limit is 10 or 40 ppb. 6. The “dilution cleaning” method has not been adequately proven for utilization on the Mars 2020 mission. Shortcomings have been identified in terms of peer review, method verification, analytical and testing approach, application to space flight hardware, and performance under Martian conditions. The method should be revisited and independently tested using statistically and analytically robust methods, and scrutinized in a rigorous peer review process. 7. The Mars 2020 mission claims considerable heritage from the Mars Science Laboratory (MSL) mission, but MSL contamination control efforts contain significant errors and implementation discrepancies that would imperil the Mars 2020 caching mission were they repeated. A standing contamination control panel should be formed to provide independent oversight for the Mars 2020 mission.

Mars Sample Return↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

Water reactive polyurethane grouting for deep vadose zone contaminant immobilization

Contaminants in the deep vadose zone (DVZ) pose a long-term threat to groundwater, human health, and the environment. Polyurethane grouting is a type of chemical grouting that is potentially advantageous in immobilizing contaminants in DVZs. Polyurethane resin has low viscosity that makes it feasible to penetrate and fill the pore space between fine particles. Here, in this study a series of laboratory pressure grouting and leaching tests were conducted to simulate and assess the effectiveness of polyurethane grouting for immobilizing contaminants in DVZs. Soil with fine particles was prepared with 127 I (as iodide) that served as a non-radioactive surrogate for radioactive 129 I. After grouting and curing, leaching tests were used to measure and compare contaminant diffusivity and leachability index values. Additionally, changes in porosity and saturated hydraulic conductivity of grouted soil were measured. X-Ray Computer Tomography (XCT) results showed that the cured polyurethane was distributed nearly homogeneously and approximately half of the voids were filled with cured polyurethane. Grouting reduced the saturated hydraulic conductivity of soil by 37 %. The effective diffusivity decreased by more than 80 % as compared with the ungrouted soil. The leachability index of the grouted soil was 6.5; meeting the criteria established by the U.S. Nuclear Regulatory Commission (NRC) standard. The results obtained in this study provide a valuable assessment of polyurethane grouting for iodide immobilization in the DVZ and indicate this approach may be a viable method for contaminant remediation in DVZ soils.

Contaminant Diffusion↗

International Space Station Bipropellant Plume Contamination Model Update for Short Thruster Pulse Widths

The International Space Station (ISS) Bipropellant Plume Contamination Model has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS but was not intended to be used for very short thruster pulse widths. This paper presents an updated model that ensures full start-up and shut-down phases are modeled for each thruster firing, when the majority of liquid phase contaminant mass is released. The updated ISS Bipropellant Plume Contamination Model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations and provides a way to take advantage of thruster start-up and shut-down data performance data gathered during thruster test programs, if available.

bipropellant↗

International Space Station Bipropellant Plume Contamination Model update for short thruster pulse widths

The International Space Station (ISS) Bipropellant Plume Contamination Model has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS but was not intended to be used for very short thruster pulse widths. This paper presents an updated model that ensures full start-up and shut-down phases are modeled for each thruster firing, when the majority of liquid phase contaminant mass is released. The updated ISS Bipropellant Plume Contamination Model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations and provides a way to take advantage of thruster start-up and shut-down performance data gathered during thruster test programs, if available.

thruster plumes↗

Using radioactive material to evaluate decontamination of contaminated electronics

Electronic materials are used everywhere and can get easily contaminated by their use in the field/laboratory. The goal of this project was to use radioactive material to track the effectiveness of a cleaning procedure using an off-the-shelf cleaning gel. Radioactive potassium bromide (KBr) was used as a model contaminant in four contamination scenarios to gauge the effectiveness of a cleaning gel in the decontamination of contaminated raspberry pi’s. Finally, the investigated decontamination technique was found to be 75–97% effective in removing contamination from the tested electronic devices. 95% of the contaminated electronic devices retained their functionality post-decontamination.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Environmental fate of radiocesium in biota inhabiting a contaminated ecosystem on the U.S. Department of Energy's Savannah River Site

Although biomagnification of radiocesium ( 137 Cs) has been reported in food webs, most previous research has been limited to select trophic linkages. Few studies have included a comprehensive survey of fauna associated with aquatic, semi-aquatic, and terrestrial habitats within a single study framework. The objectives of this study were to advance our understanding of the dynamics of 137 Cs accumulation within food webs by quantifying 137 Cs activity across a wide range of biota found within a contaminated canal, as well as test the hypothesis that life-stage and body size influence 137 Cs bioaccumulation in select herpetofauna. With extensive sampling across multiple taxa collected from a contaminated canal system and associated floodplain on the Savannah River Site, we assessed 137 Cs activity and stable nitrogen isotopes for both aquatic organisms that were restricted to the contaminated effluent canal, and semi-aquatic organisms able to move freely between the contaminated canal and the adjacent uncontaminated terrestrial habitat. We found 137 Cs activity to be highly variable among species, with evidence for and against biomagnification in semi-aquatic and aquatic organisms, respectively. Furthermore, 137 Cs activity decreased with life stage and body size in bullfrogs (Lithobates catesbeianus), despite post-metamorphic bullfrogs having a more carnivorous diet compared to tadpoles, while cottonmouths (Agkistrodon piscivorus) retained similar 137 Cs activity regardless of their age and size. While evidence of biomagnification has been observed in some contaminated systems, results of our study suggest the extent to which 137 Cs biomagnifies within food webs is context-dependent and likely influenced by a suite of biotic and abiotic factors. Further, our data indicate sampling of a broad suite of species and environmental attributes are needed to elucidate the fate and dynamics of anthropogenic pollutants within contaminated ecosystems.

54 ENVIRONMENTAL SCIENCES↗

ContScout: sensitive detection and removal of contamination from annotated genomes

Contamination of genomes is an increasingly recognized problem affecting several downstream applications, from comparative evolutionary genomics to metagenomics. Here we introduce ContScout, a precise tool for eliminating foreign sequences from annotated genomes. It achieves high specificity and sensitivity on synthetic benchmark data even when the contaminant is a closely related species, outperforms competing tools, and can distinguish horizontal gene transfer from contamination. A screen of 844 eukaryotic genomes for contamination identified bacteria as the most common source, followed by fungi and plants. Furthermore, we show that contaminants in ancestral genome reconstructions lead to erroneous early origins of genes and inflate gene loss rates, leading to a false notion of complex ancestral genomes. Taken together, we offer here a tool for sensitive removal of foreign proteins, identify and remove contaminants from diverse eukaryotic genomes and evaluate their impact on phylogenomic analyses.

59 BASIC BIOLOGICAL SCIENCES↗

Modeled sensitivity of multi-MA accelerator performance to electrode contaminant inventory

Significant particle-in-cell code development has enabled simulations of power flow in multi-MA accelerators to include the desorption of surface contaminants, their ionization into surface plasmas, and the impact of these plasmas on efficiency. The simulations base desorption on an Arrhenius equation, whose most significant unknown is the surface contaminant inventory. The sensitivity of power-flow simulations to this inventory is studied here using Sandia National Laboratories' Z accelerator with a 7-nH MagLIF load [Phys. Plasmas 17, 056303 (2010)]. Simulations are conducted in 3D cylindrical coordinates for the current-adder, or “convolute,” region of Z and in 2D for the final feed only. Simulated contaminant inventories are varied from 1 to 32 monolayers (MLs) in 2D, and 2 to 4 ML in 3D. The results reveal sensitivities to the local ratio of E/B⁠. The high B-field, low E-field region near the short-circuit load is insensitive to the contaminant inventory, where assumed values of 4–32 ML change the load current by ≤ 2%, and agree with experiment to within 2% at peak current. A 1-ML value is the outlier, increasing the load current by 5%, but still within measurement uncertainty. In contrast, the relatively higher E-field, lower B-field convolute region has slower contaminant desorption and higher-magnitude E-field penetration of the surface plasmas. The current loss in the convolute region does increase with contaminant inventory. The loss assuming 4 ML is 12% larger than for 2 ML, with 4 ML being the better match to experiment.

Arrhenius equation↗

Measurable radiation levels around individuals externally contaminated by nuclear fallout

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger–Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235 U-fueled device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Apollo experience reports: Window contamination

The problem of window contamination in the Apollo command module is reviewed. All five command module windows were contaminated while in earth orbit on the first three manned Apollo flights. The contamination sources were identified and eliminated. Preflight testing of lunar module windows showed that no serious contamination should occur, and this conclusion was verified in subsequent manned flights. The command module window designs and materials are described, the window contamination sources are identified, and the inflight and chemical analyses of the contamination are outlined. The corrective actions that were taken are reviewed. For the lunar module, the window design and materials and the preflight and fight evaluations are described. Window design recommendations are made.

Leger, L. J.↗

Organic contamination problems in the Viking molecular analysis experiment

A principal problem in interpreting the results of an organic analysis of an extraterrestrial sample is that of distinguishing contaminating material from indigenous material when unknown types and amounts of contaminants make their way into the sample being analyzed. An approach to control of sample integrity in the Viking molecular analysis experiment has been devised which it is believed, will eliminate such problems. Basically this involves (1) placing an upper limit on the amount of terrestrial contamination that can be tolerated and still allow scientifically meaningful analysis, (2) identifying the potential sources of contamination and analyzing their relative significance, (3) establishing methods to control these sources, and (4) obtaining complete information on the chemical composition of potential contaminants. Previous experience in the Apollo mission has been of great value in developing the Viking program, perhaps the most important carryover being the recognition of the importance of establishing a comprehensive contamination control program in the early stages of mission planning and hardware design.

Flory, D. A.↗

Preliminary results Skylab experiment TO27 optical contamination in space

Current results from the TO27 experiment which was performed on the first two Skylab missions are presented. The purpose of the experiment was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly and to measure the sky brightness background caused by solar illumination of particulate contaminants. The sample array system containing 248 optical surfaces and exposed outside the orbital workshop did not collect any significant contaminants. Only trace amounts of surface deposited contaminants have been seen, in all cases the measurement was near the limiting sensitivity of the instrument. Unfortunate performance compromises and the relative cleanliness of the assembly on the anti-solar side appeared to place the amount of available surface contaminants near the limiting sensitivity of the sample array. Mass spectroscopy on the trace contaminants show the presence of high molecular weight species, up to 773 amu. The data suggests the presence of condensed aromatics.

Muscari, J. A.↗

Correlation of an optical system degradation with contamination on a critical surface

The loss of sensitivity of a radiantly cooled radiometer during space operation was investigated. A quartz crystal microbalance (QCM), mounted in the proximity of the instrument filter lens and held at its temperature, measured the contaminant at the location during a vacuum test. The temperature cycling of the lens and the QCM verified the contamination of the lens as the cause of the deterioration. Data on the instrument performance in space and in the chamber allowed estimation of the rate of contaminant accretion on the lens in space service. That rate was used to estimate the contaminant partial pressure. The nature of material was inferred by comparison of the partial pressures and the saturated vapor pressures of materials at the temperature of the contaminated surface. These data, in conjunction with data on fields of view of the lens, are used to identify the sources of contamination.

Scialdone, J. J.↗

Preliminary evaluation of the contaminant induced environment for the space shuttle orbiter

A preliminary evaluation of the on-orbit induced environment from identified major sources of contamination for the STS shuttle orbiter is presented. A contamination computer mathematical model is discussed that was used to develop the description and predictions of the induced environment along with the extent and physical makeup of the molecular induced environment from these sources. The predicted induced molecular environment from each source is evaluated against current Space Shuttle Program on-orbit contamination control criteria. The flash evaporator vents and the VCS 25-lb thrust engines are shown to significantly exceed applicable contamination control criteria and were the subject of extensive evaluation. Preliminary conclusions concerning the contaminant potential of these sources along with recommendations for various measures of contamination control regarding the shuttle orbiter design and operational activities are made.

Bareiss, L. E.↗

Payload/orbiter contamination control requirement study

The Spacelab carrier induced contaminant environment and Spacelab's ability to meet established contamination control criteria for the shuttle program are determined. The primary areas of on-going activity include updating, refining, and improving the Spacelab Contamination Computer Model and contamination analysis methodology; establishing the resulting adjusted induced environment predictions for comparison with the applicable criteria; determining Spacelab design and operational requirements necessary to meet the criteria; conducting mission feasibility analyses of the combined Spacelab/orbiter contaminant environment for specific proposed missions and payload mixes; and establishing a preliminary Spacelab mission support plan and model interface requirements. A summary is given of these activities conducted to date including any modifications in approach or methodology utilized in the contamination assessment of the Spacelab vehicle. The emphasis is placed on the Spacelab modeling efforts.

Bareiss, L. E.↗

Organizational strategies for protection against back contamination

The organizational issues pertaining to the prevention of inbound contamination associated with possible Viking missions to Mars are considered. The completed Apollo missions, which returned samples from the moon, provide a convenient base for analysis of inbound contamination issues. Despite concern over the threat of inbound contamination from the moon and efforts to prevent back contamination, the back contamination efforts in the Apollo missions were considered ineffective had these missions encountered living organisms. Several alternatives for consideration in the design of future programs dealing with back contamination are examined and proposed for special consideration.

Mahoney, T. A.↗