Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contamination Control Process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Update on N2O4 Molecular Sieving with 3A Material at NASA/KSC

During its operational life, the Shuttle Program has experienced numerous failures in the Nitrogen Tetroxide (N2O4) portion of Reaction Control System (RCS), many of which were attributed to iron-nitrate contamination. Since the mid-1980's, N2O4 has been processed through a molecular sieve at the N2O4 manufacturer's facility which results in an iron content typically less than 0.5 parts-per-million-by-weight (ppmw). In February 1995, a Tiger Team was formed to attempt to resolve the iron nitrate problem. Eighteen specific actions were recommended as possibly reducing system failures. Those recommended actions include additional N2O4 molecular sieving at the Shuttle launch site. Testing at NASA White Sands Test Facility (WSTF) determined an alternative molecular sieve material could also reduce the water-equivalent content (free water and HNO3) and thereby further reduce the natural production of iron nitrate in N2O4 while stored in iron-alloy storage tanks. Since April '96, NASA Kennedy Space Center (KSC) has been processing N2O4 through the alternative molecular sieve material prior to delivery to Shuttle launch pad N2O4 storage tanks. A new, much larger capacity molecular sieve unit has also been used. This paper will evaluate the effectiveness of N2O4 molecular sieving on a large-scale basis and attempt to determine if the resultant lower-iron and lower-water content N2O4 maintains this new purity level in pad storage tanks and shuttle flight systems.

Davis, Chuck↗

Trace Contaminant Control Test Bed for Evaluation of TCC Prototypes with Vacuum Regenerable and Non-Regenerable Sorbents

A new Space Suit Exploration Portable Life Support System (xPLSS) is being designed, built, integrated, and tested into the Extra-Vehicular Mobility Unit (xEMU). The Trace Contaminant Control (TCC) system is a component in the oxygen ventilation loop of xPLSS that removes contaminants generated by the crewmembers’ metabolic processes. The primary trace contaminants that must be removed include ammonia (NH3), carbon monoxide (CO), formaldehyde (CH2O), and methyl mercaptan (CH3SH). The current state-of-the-art TCC sorbent is non-regenerable activated carbon. As a non-regenerable sorbent, its use negatively impacts the logistics for future missions. Thus, an ideal solution can be a vacuum-regenerable sorbent integrated with the xPLSS CO2/H2O removal system. To test new designs and sorbents, XploSafe has constructed a recirculating test bed that mimics the environment within the xPLSS by providing concentrations of the trace contaminant analytes generated at the operating temperature, humidity, pressure, and flow rates of the xPLSS. This system can perform regeneration or desorption by exposing the sorbent to a pressure swing from 4.3 psia to <1 torr over approximately 2 minutes. Using this test system, XploSafe evaluated various TCC prototypes constructed using rapid prototyping techniques and identified a process that allows vacuum regenerative TCC designs to be quickly examined for flow, pressure drop, and performance. By using toluene as a segregate for volatile organics, this test system was evaluated using both vacuum regenerable and non-regenerable sorbents to demonstrate the operational effectiveness of these sorbents in maintaining the concentrations of the trace contaminant analytes below the 7-day Spacecraft Maximum Allowable Concentrations.

Nicholas Materer↗

A Review of International Space Station Habitable Element Equipment Offgassing Characteristics

Crewed spacecraft trace contaminant control employs both passive and active methods to achieve acceptable cabin atmospheric quality. Passive methods include carefully selecting materials of construction, employing clean manufacturing practices, and minimizing systems and payload operational impacts to the cabin environment. Materials selection and manufacturing processes constitute the first level of equipment offgassing control. An element-level equipment offgassing test provides preflight verification that passive controls have been successful. Offgassing test results from multiple International Space Station (ISS) habitable elements and cargo vehicles are summarized and implications for active contamination control equipment design are discussed

Perry, Jay L.↗

Microtextured metals for stray-light suppression in the Clementine startracker

Anodized blacks for suppressing stray light in optical systems can now be replaced by microscopically textured metal surfaces. An application of these black surfaces to the Clementine star-tracker navigational system, which will be launched in early 1994 to examine the Moon, en route to intercept an asteroid, is detailed. Rugged black surfaces with Lambertian BRDF less than 10(exp -2) srad(sup -1) are critical for suppressing stray light in the star-tracker optical train. Previously available materials spall under launch vibrations to contaminate mirrors and lenses. Microtextured aluminum is nearly as dark, but much less fragile. It is made by differential ion beam sputtering, which generates light-trapping pores and cones slightly smaller than the wavelength to be absorbed. This leaves a sturdy but light-absorbing surface that can survive challenging conditions without generating debris or contaminants. Both seeded ion beams and plasma immersion (from ECR plasmas) extraction can produce these microscopic textures without fragile interfaces. Process parameters control feature size, spacing, and optical effects (THR, BRDF). Both broad and narrow absorption bands can be engineered with tuning for specific wavelengths and applications. Examples are presented characterized by FTIR in reflection librators (0.95 normal emissivity), heat rejection, and enhanced nucleate boiling.

Johnson, E. A.↗

Integrated System Design for Air Revitalization in Next Generation Crewed Spacecraft

The capabilities of NASA's existing environmental control and life support (ECLS) system designs are inadequate for future human space initiatives that involve long-duration space voyages and interplanetary missions. This paper discusses the concept of an integrated system of CO2 removal and trace contaminant control units that utilizes novel gas separation and purification techniques and optimized thermal and mechanical design, for future spacecraft. The integration process will enhance the overall life and economics of the existing systems by eliminating multiple mechanical devices with moving parts.

Mulloth, Lila↗

Heating and Thermal Control of Brazing Technique to Break Contamination Path for Potential Mars Sample Return

The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth’s environment. In order to ensure the isolation of Mars microbes from Earth’s Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-the-chain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

Bao, Xiaoqi↗

Making AlN(x) Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam

A technique based on accelerating positive nitrogen ions onto an aluminum layer has been demonstrated to be effective in forming thin (<2 nm thick) layers of aluminum nitride (AlN(x)) for use as tunnel barriers in Nb/Al-AlN(x)/Nb superconductor/insulator/ superconductor (SIS) Josephson junctions. AlN(x) is the present material of choice for tunnel barriers because, to a degree greater than that of any other suitable material, it offers the required combination of low leakage current at high current density and greater thermal stability. While ultra-thin AlN films with good thickness and stoichiometry control are easily formed using techniques such as reactive molecular beam epitaxy and chemical vapor deposition, growth temperatures of 900 C are necessary for the dissociative adsorption of nitrogen from either nitrogen (N2) or ammonia (NH3). These growth temperatures are prohibitively high for the formation of tunnel barriers on Nb films because interfacial reactions at temperatures as low as 200 to 300 C degrade device properties. Heretofore, deposition by reactive sputtering and nitridation of thin Al layers with DC and RF nitrogen plasmas have been successfully used to form AlN barriers in SIS junctions. However, precise control over critical current density Jc has proven to be a challenge, as is attaining adequate process reproducibility from system to system. The present ion-beam technique is an alternative to the plasma or reactive sputtering techniques as it provides a highly controlled arrival of reactive species, independent of the electrical conditions of the substrate or vacuum chamber. Independent and accurate control of parameters such as ion energy, flux, species, and direction promises more precise control of film characteristics such as stoichiometry and thickness than is the case with typical plasma processes. In particular, the background pressure during ion-beam nitride growth is 2 or 3 orders of magnitude lower, minimizing the formation of compounds with contaminants, which is critical in devices the performance of which is dictated by interfacial characteristics. In addition, the flux of incoming species can be measured in situ using ion probes so that the dose can be controlled accurately. The apparatus used in the present ion-beam technique includes a vacuum chamber containing a commercial collimated- ion-beam source, a supply of nitrogen and argon, and an ion probe for measuring the ion dose. Either argon or nitrogen can be used as the feed gases for the ion source, depending on whether cleaning of the substrate or growth of the nitride, respectively, is desired. Once the Nb base electrode and Al proximity layer have been deposited, the N2 gas line to the ion beam is vented and purged, and the ion-source is turned on until a stable discharge is obtained. The substrate is moved over the ion-beam source to expose the Al surface layer to the ion beam (see figure) for a specified duration for the formation of the nitride tunnel barrier. Next, the Nb counter-electrode layer is deposited on the nitride surface layer. The Nb/Al- AlN(x)/Nb-trilayer-covered substrate is then patterned into individual devices by use of conventional integrated-circuit processing techniques.

Kaul, Anupama↗

Arc spray fabrication of metal matrix composite monotape

Arc metal spraying is used to spray liquid metal onto an array of high strength fibers that were previously wound onto a large drum contained inside a controlled atmosphere chamber. This chamber is first evacuated to remove gaseous contaminants and then backfilled with a neutral gas up to atmospheric pressure. This process is used to produce a large size metal matrix composite monotape.

Westfall, L. J.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples

Gaier, James R.↗

The Spacecraft Mass Balance as a Diagnostic Tool for Cabin Air Quality

The spacecraft-level mass balance is a powerful tool for diagnosing and decoupling factors influencing cabin air quality, especially with respect to trace contaminant propagation. Successful implementation of this approach relies upon accurate and temporally relevant air quality measurements, which are often challenging to attain for emerging trace contaminants. In addition to the proper interpretation of air quality data trends, a thorough understanding of subsystem-level mass transfer is required to characterize process performance. For many Environmental Control and Life Support System processes, subsystem mass transfer may be predicted based on physicochemical properties and classic unit operation design approaches. Gaps in understanding of process performance should be supplemented with thorough ground testing. A high confidence in the fidelity of one of these two aspects, air quality data or process performance, may help offset uncertainties in the other. At minimum, thresholding assumptions and numerical methods can be imposed to constrain unknown parameters within the physical envelope of the situation at hand. Finally, the complexity of cabin-wide integrated mass balances may be reduced by implementing a phenomenological approach towards subsystem discretization.

Cabin Air-quality↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Improved head-controlled TV system produces high-quality remote image

Manipulator operator uses an improved resolution tv camera/monitor positioning system to view the remote handling and processing of reactive, flammable, explosive, or contaminated materials. The pan and tilt motions of the camera and monitor are slaved to follow the corresponding motions of the operators head.

Goertz, R.↗

Contamination analyses of technology mirror assembly optical surfaces

Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.

Germani, Mark S.↗

Regenerative life support technology challenges for the Space Exploration Initiative

Regenerative life support systems have been identified as one of the critical enabling technologies for future human exploration of space. This discipline encompasses processes and subsystems which regenerate the air, water, solid waste, and food streams typical of human habitation so as to minimize the mass and volume of stored consumables which must accompany the humans on a mission. A number of key technology challenges within this broad discipline are described, ranging from the development of new physical, chemical, and biological processes for regenerating the air, water, solid waste, and food streams to the development of improved techniques for monitoring and controlling microbial and trace constituent contamination. A continuing challenge overarching the development of these new technologies is the need to minimize the mass, volume, and electrical power consumption of the flight hardware. More important for long duration exploration missions, however, is the development of highly reliable, long-lived, self- sufficient systems which absolutely minimize the logistics resupply and operational maintenance requirements of the life support system and which ensure human safety through their robust, reliable operating characteristics.

Bilardo, Vincent J., Jr.↗

Phase Diagram, Melt Growth and Characterization of Cd0.8Zn0.2Te Crystals for X-Ray Detector

In this study, the solidus curve of the Cd0.8Zn0.2Te homogeneity range was constructed from the partial pressure measurements by optical absorption technique which provided the information of the melt growth parameters to process crystals with the required electrical resistivity. The melt growth of Cd0.8Zn0.2Te crystals were then processed by directional solidification under controlled Cd overpressure. During the growth experiments, several procedures have been developed to improve the crystalline quality: (1) minimizing the contamination of impurities (2) improving the structural defects and (3) minimizing the Te-precipitates within the grown crystals to enhance charge transport properties. Additionally, the thermal conductivity, electrical conductivity, and Seebeck coefficient of a vapor-grown CdTe and two melt-grown Cd0.8Zn0.2Te crystals were measured between 190oC and 780oC to provide an in-depth understanding of the thermal and electrical conduction mechanisms of the crystals as well as the prospect of its thermoelectric applications.

x-ray detector↗

NASA Advanced Explorations Systems: Advancements in Life Support Systems

The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide environmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions assessed by NASA's Habitability Architecture Team (HAT). The LSS project is focused on four areas: architecture and systems engineering for life support systems, environmental monitoring, air revitalization, and wastewater processing and water management. Starting with the international space station (ISS) LSS systems as a point of departure (where applicable), the mission of the LSS project is three-fold: 1. Address discrete LSS technology gaps 2. Improve the reliability of LSS systems 3. Advance LSS systems towards integrated testing on the ISS. This paper summarized the work being done in the four areas listed above to meet these objectives. Details will be given on the following focus areas: Systems Engineering and Architecture- With so many complex systems comprising life support in space, it is important to understand the overall system requirements to define life support system architectures for different space mission classes, ensure that all the components integrate well together and verify that testing is as representative of destination environments as possible. Environmental Monitoring- In an enclosed spacecraft that is constantly operating complex machinery for its own basic functionality as well as science experiments and technology demonstrations, it's possible for the environment to become compromised. While current environmental monitors aboard the ISS will alert crew members and mission control if there is an emergency, long-duration environmental monitoring cannot be done in-orbit as current methodologies rely largely on sending environmental samples back to Earth. The LSS project is developing onboard analysis capabilities that will replace the need to return air and water samples from space for ground analysis. Air Revitalization- The air revitalization task is comprised of work in carbon dioxide removal, oxygen generation and recovery and trace contamination and particulate control. The CO2 Removal and associated air drying development efforts under the LSS project are focused both on improving the current SOA technology on the ISS and assessing and examining the viability of other sorbents and technologies available in academia and industry. The Oxygen Generation and Recovery technology development area encompasses several sub-tasks in an effort to supply O2 to the crew at the required conditions, to recover O2 from metabolic CO2, and to recycle recovered O2 back to the cabin environment. Current state-of-the-art oxygen generation systems aboard space station are capable of generating or recovering approximately 40% of required oxygen; for exploration missions this percentage needs to be greatly increased. A spacecraft cabin trace contaminant and particulate control system serves to keep the environment below the spacecraft maximum allowable concentration (SMAC) for chemicals and particulates. Both passive (filters) and active (scrubbers) methods contribute to the overall TC & PC design. Work in the area of trace contamination and particulate control under the LSS project is focused on making improvements to the SOA TC & PC systems on ISS to improve performance and reduce consumables. Wastewater Processing and Water Management- A major goal of the LSS project is the development of water recovery systems to support long duration human exploration beyond LEO. Current space station wastewater processing and water management systems distill urine and wastewater to recover water from urine and humidity condensate in the spacecraft at a approximately 74% recovery rate. For longer, farther missions into deep space, that recovery rate must be greatly increased so that astronauts can journey for months without resupply cargo ships from Earth.

Shull, Sarah A.↗

Discovery: Under the Microscope at Kennedy Space Center

The National Aeronautics & Space Administration (NASA) is known for discovery, exploration, and advancement of knowledge. Since the days of Leeuwenhoek, microscopy has been at the forefront of discovery and knowledge. No truer is that statement than today at Kennedy Space Center (KSC), where microscopy plays a major role in contamination identification and is an integral part of failure analysis. Space exploration involves flight hardware undergoing rigorous "visually clean" inspections at every step of processing. The unknown contaminants that are discovered on these inspections can directly impact the mission by decreasing performance of sensors and scientific detectors on spacecraft and satellites, acting as micrometeorites, damaging critical sealing surfaces, and causing hazards to the crew of manned missions. This talk will discuss how microscopy has played a major role in all aspects of space port operations at KSC. Case studies will highlight years of analysis at the Materials Science Division including facility and payload contamination for the Navigation Signal Timing and Ranging Global Positioning Satellites (NA VST AR GPS) missions, quality control monitoring of monomethyl hydrazine fuel procurement for launch vehicle operations, Shuttle Solids Rocket Booster (SRB) foam processing failure analysis, and Space Shuttle Main Engine Cut-off (ECO) flight sensor anomaly analysis. What I hope to share with my fellow microscopists is some of the excitement of microscopy and how its discoveries has led to hardware processing, that has helped enable the successful launch of vehicles and space flight missions here at Kennedy Space Center.

Howard, Philip M.↗