Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Laboratory Demonstration of Phase Induced Amplitude Apodization (PIAA) Coronagraph with Better than 10(exp -9) Contrast

We present coronagraphic images from the Phase Induced Amplitude Apodization (PIAA) coronagraph on NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Lab, showing contrasts of 5x10(exp -1) averaged from 2-4 lambda/D, in monochromatic light at 808 nm. In parallel with the coronagraph and its deformable mirror and coronagraphic wavefront control, we also demonstrate a low-order wavefront control system, giving 100 x rms suppression of introduced tip/tilt disturbances down to residual levels of 10(exp -3) lambda/D. Current limitations, as well as broadband (10% fractional bandpass) preliminary results are discussed.

deformable mirror (DM)↗

The Potential of High-Contrast Coronagraphy

The direct detection of faint companions near much brighter stars requires the development of very high-contrast, small field-of-view detection techniques, and the past decade has seen remarkable conceptual and instrumental progress in this area. New coronagraphic techniques are being developed and deployed, as are extreme adaptive optics (ExAO) systems that will enable the advantageous exploitation of these new techniques. This paper provides a short overview of promising high contrast coronagraphic techniques, as well as recent examples of ExAO coronagraphy and transit measurements obtained with the ExAO-level "well-corrected subaperture" at Palomar.

Serabyn, E.↗

The CHARIS IFS for high contrast imaging at Subaru

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) being built for the Subaru telescope. CHARIS will take spectra of brown dwarfs and hot Jovian planets in the coronagraphic image provided by the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) and AO188 adaptive optics systems. The system is designed to detect objects five orders of magnitude dimmer than their parent star down to an 80 milliarcsecond inner working angle. For characterization, CHARIS has a high-resolution prism providing an average spectral resolution of R82, R69, and R82 in J, H, and K bands respectively. The so-called discovery mode uses a second low-resolution prism with an average spectral resolution of R19 spanning 1.15-2.37 microns (J+H+K bands). This is unique compared to other high contrast IFS designs. It augments low inner working angle performance by reducing the separation at which we can rely on spectral differential imaging. The principal challenge for a high-contrast IFS is quasi-static speckles, which cause undue levels of spectral crosstalk. CHARIS has addressed this through several key design aspects that should constrain crosstalk between adjacent spectral features to be below 1%. Sitting on the Nasmyth platform, the alignment between the lenslet array, prism, and detector will be highly stable, key for the performance of the data pipeline. Nearly every component has arrived and the project is entering its final build phase. Here we review the science case, the resulting design, status of final construction, and lessons learned that are directly applicable to future exoplanet instruments.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

Hi-5: A Potential High-Contrast Thermal Near-Infrared Imager for the VLTI

Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 μm) and advanced fringe tracking strategies. We also address the strong exoplanet science case (young exoplanets, planet formation, and exozodiacal disks) offered by this wavelength regime as well as other possible science cases such as stellar physics (fundamental parameters and multiplicity) and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.

exozodiacal dust↗

High-Contrast Polarimetry Observation of the T Tau Circumstellar Environment

We conducted high-contrast polarimetry observations of T Tau in the H-band, using the High Contrast Instrument for the Subaru Next Generation Adaptive Optics instrument mounted on the Subaru Telescope, revealing structures as near as 0farcs1 from the stars T Tau N and T Tau S. The whole T Tau system is found to be surrounded by nebula-like envelopes, and several outflow-related structures are detected in these envelopes. We analyzed the detailed polarization patterns of the circumstellar structures near each component of this triple young star system and determined constraints on the circumstellar disks and outflow structures. We suggest that the nearly face-on circumstellar disk of T Tau N is no larger than 0".8, or 117 au, in the northwest, based on the existence of a hole in this direction, and no larger than 0".27, or 40 au, in the south. A new structure, "N5," extends to about 0."42, or 59 au, southwest of the star, and is believed to be part of the disk. We suggest that T Tau S is surrounded by a highly inclined circumbinary disk with a radius of about 0."3, or 44 au, with a position angle of about 30°, that is misaligned with the orbit of the T Tau S binary. After analyzing the positions and polarization vector patterns of the outflow-related structures, we suggest that T Tau S should trigger the well-known E–W outflow, and is also likely to be responsible for a southwest precessing outflow "coil" and a possible south outflow.

Yang, Yi↗

Characterization of Low Mass Deformable Mirrors and ASIC Driver for High-Contrast Imaging

The development of compact, high performance Deformable Mirrors (DMs) is one of the most important techno-logical challenges for high-contrast imaging on space missions. Microscale Inc. has fabricated and characterized piezoelectric stack actuator deformable mirrors (PZT-DMs) and Application-Speci c Integrated Circuit (ASIC) drivers for direct integration. The DM-ASIC system is designed to eliminate almost all cables, enabling a very compact optical system with low mass and low power consumption. We report on the optical tests used to evaluate the performance of the DM and ASIC units. We also compare the results to the requirements for space-based high-contrast imaging of exoplanets. .

Prada, Camilo Mejia↗

Evaluation of Tablet-Based Methods for Assessment of Contrast Sensitivity

Some astronauts have suffered degradation of vision during long-duration space flight, suffering from a condition that has come to be known as Spaceflight Associated Neuro-ocular Syndrome (SANS). While related morphological changes can be observed with imaging technologies such as optical coherence tomography (OCT), it may be useful to have a rapid method for functional vision assessment. In this paper, we compare three tablet-based methods for rapid assessment of contrast sensitivity. First, a relatively novel method developed expressly for touch screens, in which the subject ”swipes” a frequency/contrast sweep grating to indicate the boundary between visible and invisible patterns; second, a method-of-adjustment task in which the subject adjusts the contrast of a grating patch up and down to bracket the visual threshold; and third, a traditional temporal two-alternative forced choice (2AFC) task, in which the subject is presented with a near-threshold stimulus in one of two intervals, and must report the interval containing the stimulus. The swipe method shows variability comparable to the 2AFC method, and shows good agreement in estimates of the spatial frequency of peak sensitivity. The absolute sensitivity estimated with the swipe method is higher than that of the other methods, perhaps because subjects are biased to trace outside of the visible pattern region, or perhaps due to stimulus differences.

Mulligan, Jeffrey B.↗

Keck/OSIRIS Paβ High-contrast Imaging and Updated Constraints on PDS 70b

We present a high-contrast imaging search for Paβ line emission from protoplanets in the PDS 70 system with Keck/OSIRIS integral field spectroscopy. We applied the high-resolution spectral differential imaging technique to the OSIRIS J-band data but did not detect the Paβ line at the level predicted using the parameters of Hashimoto et al. (2020). This lack of Paβ emission suggests the MUSE-based study may have overestimated the line width of Hα. We compared our Paβ detection limits with the previous Hα flux and Hβ limits and estimated AV to be ∼0.9 and 2.0 for PDS 70 b and c, respectively. In particular, PDS 70 b’s AV is much smaller than implied by high-contrast near-infrared studies, which suggests the infrared-continuum photosphere and the hydrogen-emitting regions exist at different heights above the forming planet.

Taichi Uyama↗

Enabling High-Contrast Imaging of Binary Stars With the Roman Space Telescope Coronagraph Instrument

A large fraction of Sun-like stars is contained in binary systems, in fact within 10 pc there are 67 FGK stars, out of which 42 belong to a multi-star system, and 28 have companion leak that is greater than 1e-9 contrast, assuming typical Hubble-quality space optics. Currently, those binary stars are not included in the Roman Space Telescope Coronagraph Instrument target list, but they could be observed if high-contrast imaging around binary star systems using Roman was possible. The Multi-Star Wavefront Control (MSWC) algorithm can be used to suppress companion star leakage. If the targets have angular separations larger than the Nyquist controllable region of the Deformable Mirror, MSWC must operate in its Super-Nyquist (SN) mode. This mode requires a target star replica within the SN region in order to provide the ability to null speckles at SN angular separations. For the case of Roman, more than half of the targets that can be observed using MSWC, including Alpha Centauri, have angular separations larger than the Nyquist controllable region of the 48x48 actuator Deformable Mirror (DM) to be used. In this paper, we describe how super-Nyquist MSWC can be implemented in Roman CGI adding a mild grating on a replica of the Wide-field Shaped Pupil mask, which would use a spare space in the Shaped Pupil Active Mechanism. We present the feasibility analysis, simulation results, and discuss the latest results on MSWC experiment from three different laboratories at NASA Ames, the Jet Propulsion Laboratory, and the Subaru telescope.

Prada, Camilo Mejia↗

LUVOIR-ECLIPS Closed-Loop Adaptive Optics Performance and Contrast Predictions

One of the primary science goals of the Large UV/Optical/Infrared Surveyor (LUVOIR) mission concept is to detect and characterize Earth-like exoplanets orbiting nearby stars with direct imaging. The success of its coronagraph instrument ECLIPS (Extreme Coronagraph for Living Planetary Systems) depends on the ability to stabilize the wavefront from a large segmented mirror such that optical path differences are limited to tens of picometers RMS during an exposure time of a few hours. In order to relax the constraints on the mechanical stability, ECLIPS will be equipped with a wavefront sensing and control (WS\&C) architecture to correct wavefront errors up to temporal frequencies $\gtrsim$1 Hz. These errors may be dominated by spacecraft structural dynamics exciting vibrations at the segmented primary mirror. In this work, we present detailed simulations of the WS\&C system within the ECLIPS instrument and the resulting contrast performance. This study assumes wavefront aberrations based on a finite element model of a simulated telescope with spacecraft structural dynamics. Wavefront residuals are then computed according to a model of the adaptive optics system that includes numerical propagation to simulate a realistic wavefront sensor and an analytical model of the temporal performance. An end-to-end numerical propagation model of ECLIPS is then used to estimate the residual starlight intensity distribution at the science detector. We show that the contrast performance depends strongly on the target star magnitude and the spatio-temporal distribution of wavefront errors from the telescope. In cases with significant vibration, we advocate for the use of laser metrology to mitigate high temporal frequency wavefront errors and increase the mission yield.

Sirbu, Dan↗

Wetting mechanism and alteration of nano-sized shale pores: Insights from contrast variation small angle neutron scattering

Wettability of tight shale is crucial for fluid flow and mass transport process in energy geosciences. However, understanding the interfacial chemistry and wetting mechanisms at sub-nano-pore scales remains a formidable challenge. Here, in this study, the Contrast Variation technique of Small Angle Neutron Scattering (CV-SANS) is employed to investigate shale’s interfacial chemistry using reagents that possess a range of different polarities, including water, n-decane, toluene, and dimethyl methanamide. Through five different experimental strategies, we have demonstrated a successful modification of shale wettability, ranging from enhancement, weakening, to reversal. Delving into the mechanisms, we illustrated the crucial role of pre-existing liquid films in these changes, where the uniquely co-existing polar and non-polar functional groups in dimethyl methanamide acted as a conduit for interfacial chemistry adjustments. Furthermore, a solvent immersion led to matrix dilation as well as liberation of residual oil-occupied pores, resulting in altered pore size distributions, with hydrogen bonding playing a significant role in the polar groups. Interestingly, despite shale exhibiting a stronger affinity for oil over water, hydrophilic solvents induced more substantial dilation than lipophilic ones. Collectively, this work elucidates the dynamic change of interfacial chemistry via the configuration of polarity using chemical reagents, and the CV-SANS technique underscores its invaluable utilities in decoding the interfacial wettability traits in nanopore space of shale.

58 GEOSCIENCES↗

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗