Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Parallel Grid-Forming Inverter-Driven Black Start: Power-Hardware-in-the-Loop Validation: Preprint

With power systems encountering increasing deployment levels of inverter-based resources (IBRs), system restoration using grid-forming (GFM) IBRs has gained attention. Engineered to establish grid voltages in the absence of a stiff grid, black-start-capable GFM IBRs are expected to enhance power system resilience by playing a critical role in bottom-up system restoration. This paper experimentally studies the feasibility of the novel approach through power-hardware-in-the-loop (PHIL) testing and validation with a commercial GFM inverter. The PHIL test setup demonstrates an inverter-driven black start of a 5-MW unbalanced distribution feeder where two GFM inverters collectively black start the feeder: one is a commercial hardware GFM inverter interacting through the PHIL interface, and the other is a software GFM emulated by a real-time simulation with full electromagnetic transient (EMT) models. Both GFM inverters are equipped with negative-sequence voltage control to suppress the voltage imbalance resulting from the unbalanced loading, allowing us to study the dynamic interactions between the GFMs with their control parameters unknown. To evaluate the dynamic behavior of the GFM inverters under the entire black-start process, the EMT model of the distribution system details the transformer and motor dynamics to emulate their inrush and startup behaviors. It abstracts conventional grid-connected inverter dynamics, i.e., grid-following inverters. Oscilloscope measurements of the hardware GFM inverter are also presented for critical steps. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Savannah River Site H-Canyon Process Exhaust Tunnel Inspection Crawler Development - 20036

This paper covers development of a remote crawler used to inspect a subterranean radiochemical process ventilation tunnel located at the Savannah River Site near Aiken, SC. The purpose of the inspection was to ascertain the apparent structural condition of the tunnel with video footage. Manned entry is prohibited due to the hazardous environment requiring a fully-remote approach. The inspection system used high-definition cameras to archive over 1000 linear feet in the tunnel. While previous inspections had been undertaken, this crawler was developed to overcome obstacles that had put tunnel regions out of reach of prior inspection platforms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reactive Power Control Methods for Islanded Operation

As feeder-level microgrid controls begin to incorporate multiple GFM DER and voltage regulation equipment, island reactive power dispatch strategies can be improved. Although Volt-Var Optimization (VVO) control is typical in an Advanced Distribution Management System (ADMS), most microgrid controllers do not apply VVO during island operations. This report investigates reactive power control strategies for feeder-level microgrid operations. It also proposes evaluation metrics that can be applied to analyze the performance improvements of the new microgrid control strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earthquake response of head-mounted equipment in advanced nuclear reactors

The seismic response of safety-related equipment mounted on the head of an advanced reactor, including pumps, control rod drive mechanisms, and reactor monitoring devices, will affect the design and layout of many advanced reactors. High earthquake-induced accelerations in such equipment may challenge their seismic qualification and trigger the need for additional support framing on the reactor head. Base isolation is a design solution that can drastically reduce seismic demands on equipment. This article describes a set of earthquake-simulator experiments conducted on a scale-model of a base-isolated reactor vessel including four representations of head-mounted equipment, with frequencies spanning from 4.5 to 27 Hz. Dynamic responses of the head-mounted equipment, including displacements, accelerations, and strains, were measured in the experiments for three support conditions: conventional, and seismically isolated using single concave Friction Pendulum (SFP) bearings and triple Friction Pendulum (TFP) bearings. Seismic isolation was effective at reducing equipment responses (accelerations, displacements, and strains) with respect to those in the conventionally supported vessel across a range of seismic inputs. Companion numerical studies highlight the accuracy to be expected in the calculation of different response quantities for lightly damped equipment. The importance of characterizing damping in head-mounted, safety-related equipment through physical experiments to support design and risk assessment is made clear through the numerical simulations.

Engineering↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MODELING, IMPLEMENTATION AND CONTROL OF A CVT BASED PTO FOR A SMALL SCALE MHK-TURBINE IN LOW FLOW SPEED OPERATION

Modeling, implementation, field testing and control of a power takeoff (PTO) device equipped with a ball-type continuously variable transmission (B-CVT) for a small marine hydrokinetic (MHK) turbine deployed from a floating unmanned autonomous mobile catamaran platform is described. The turbine is a partially submerged multi-blade undershot waterwheel (USWW). A validated numerical torque model for the MHK turbine has been derived and a speed controller has been developed, implemented and tested in the field. The dependance of the power generated as a function of number and submergence level of turbine blades has been investigated and the number of blades that maximizes power production is determined. Bench and field testing in support of characterizing the power conversion capabilities of MHK turbine and PTO are described. Detailed results of the final torque and power coefficient models, the controls architecture, and the MHK turbine performance with varying numbers of blades are provided.

Pimentel, Hugo↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Mitigation of Molten Salt Corrosion

The desire to increase the peak operational temperature of Concentrated Solar Power (CSP) plants to lower the levelized cost of CSP-derived electricity, has led to consideration of an earth-abundant, low-cost, thermally-stable, molten MgCl 2 -KCl-NaCl (40-40-20 mole%) salt for high-temperature thermal energy storage and heat transfer. The reliable, long-term containment of such a molten salt is challenging, however, due to the corrosion of cost-effective, high-temperature structural metal alloys in this salt (particularly if this salt is contaminated with oxygen-bearing species). This project has been focused on: i) development of equipment for evaluating corrosion kinetics in molten chlorides under well-controlled thermal, fluid dynamic, and atmospheric conditions at CSP-relevant temperatures, ii) use of such equipment to evaluate the influence of forced convection on corrosion kinetics (to determine the role of liquid phase diffusion on such corrosion), and iii) identifying a corrosion-mitigation strategy that can be industrially applied to achieve a projected annual corrosion ≤30 μm at CSP-relevant temperatures. The overall goals of this project have been: i) to understand the rate-limiting step(s) and associated kinetic laws governing corrosion in molten chlorides at 750°C, ii) to determine key operational parameters affecting the corrosion kinetics in molten salts, and iii) to demonstrate the tailoring of such parameters to appreciably reduce such corrosion.

14 SOLAR ENERGY↗

Discrete-event Simulation Process Model for the Pyrochemical Processing of Plutonium at Los Alamos National Laboratory

The pyrochemical metal production operations that occur in the Plutonium Facility at Los Alamos National Laboratory perform plutonium purification with the aim to provide plutonium metal for a variety of defense- and non-defense missions within the National Nuclear Security Administration. The demands and constraints associated with the pyrochemical processing of plutonium are complex, making decision analyses challenging for program managers who require plutonium production for their mission applications. The construction of a discrete-event simulation process model is proposed to measure and report the process capacity, material throughput, equipment requirements, and dose accumulation for operators of the pyrochemical metal production operations. The process model, constructed in the ExtendSim™ software, will represent the cause-and-effect relationships between the pyrochemical processing environment and the process constraints, including criticality limitations, material control and accountability measures, chemical analysis requirements, and equipment availability. An accurate representation of the pyrochemical metal production process capacity through simulation modeling will be helpful to program managers in their efforts to forecast plutonium availability for mission applications. Furthermore, the proposed process model will be vital for future analyses that will measure the interactions between the pyrochemical metal production operations and the aqueous reprocessing operations and their ability to minimize transuranic waste disposal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning in Buildings: Implicit Assumptions and their Impact

As deep reinforcement learning (DRL) continues to gain interest in the smart building research community, there is a transition from simulation-based evaluations to deploying DRL control strategies in actual buildings. While the efficacy of a solution could depend on a particular implementation, there are common obstacles that developers have to overcome to deliver an effective controller. Additionally, a deployment in a physical building can invalidate some of the assumptions made during the controller development. Assumptions on the sensor placement or on the equipment behavior can quickly come undone. This paper presents some of the significant assumptions made during the development of DRL based controllers that could affect their operations in a physical building. Furthermore, a preliminary evaluation revealed that controllers developed with some of these assumptions can incur twice the expected costs when they are deployed in a building.

Prakash, Anand Krishnan↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Lessons Learned—Fluoride Exposure and Response

Laboratory research can expose workers to a wide variety of chemical hazards. Researchers must not only take personal responsibility for their safety but also inevitably rely on coworkers to also work safely. The foundations for protocols, requirements, and behaviors come from our history and lessons learned from others. For that reason, here, a recent incident is examined in which a researcher suffered hydrofluoric acid (HF) burns while working with an inorganic digestion mixture of aqueous HF (8%) and nitric acid (HNO 3 , 58%). HF education is critical for workers because delays in treatment, improper treatment, and delay of symptoms are all factors in unfavorable outcomes in case reports. Furthermore, while the potential severity of the incident was elevated due to bypassed engineered controls and lack of proper personal protective equipment, only minor injuries were sustained. We discuss the results of a causal analysis of the incident that revealed areas of improvement in protocols, personal protective equipment, and emergency response that could help prevent similar accidents from occurring. We also present simple improvements that anyone can implement to reduce the potential consequences of an accident, based upon our lessons learned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fidelity Analysis of Complex Large-Scale Simulation Models of PEs (MARS) in Future Power Grids

With the proliferation of power electronic (PE)-based resources in the electric grid, there have been numerous different kinds of simulation models developed and studied to understand their dynamic behavior. Study of PE-based resources using each simulation model has its own distinct advantages and disadvantages. Therefore it is very important to carefully select the appropriate model for the evaluation of the PE-based resources. In this paper, one such effort is made to analyze the different types of models in the case of a multi-port autonomous reconfigurable solar power plant (MARS). The MARS integrates a hybrid photovoltaic (PV)-energy storage system (ESS) plant to high-voltage direct current (HVdc) system and transmission alternating current (ac) grid. The dynamic models are evaluated under different test cases varying the short-circuit ratio (SCR) and control algorithms. Recommendations are provided on the equipment study needs based on the analysis completed.

Marthi, Phani Ratna Vanamali↗