Transformation of two and three-dimensional regions by elliptic systems

Several reports are attached to this document which contain the results of our research at the end of this contract period. Three of the reports deal with our work on generating surface grids. One is a preprint of a paper which will appear in the journal Applied Mathematics and Computation. Another is the abstract from a dissertation which has been prepared by Ahmed Khamayseh, a graduate student who has been supported by this grant for the last two years. The last report on surface grids is the extended abstract of a paper to be presented at the 14th IMACS World Congress in July. This report contains results on conformal mappings of surfaces, which are closely related to elliptic methods for surface grid generation. A preliminary report is included on new methods for dealing with block interfaces in multiblock grid systems. The development work is complete and the methods will eventually be incorporated into the National Grid Project (NGP) grid generation code. Thus, the attached report contains only a simple grid system which was used to test the algorithms to prove that the concepts are sound. These developments will greatly aid grid control when using elliptic systems and prevent unwanted grid movement. The last report is a brief summary of some timings that were obtained when the multiblock grid generation code was run on the Intel IPSC/860 hypercube. Since most of the data in a grid code is local to a particular block, only a small fraction of the total data must be passed between processors. The data is also distributed among the processors so that the total size of the grid can be increase along with the number of processors. This work is only in a preliminary stage. However, one of the ERC graduate students has taken an interest in the project and is presently extending these results as a part of his master's thesis.

Mastin, C. Wayne↗

Energy Services Interface: Requirements Document

This energy services interface (ESI) requirements document represents a process step in the path for creating an ESI specification, which will describe the technical characteristics of an ESI. This document outlines the concepts that need to be covered in the ESI specification, such as principal functions of the ESI, grid services communicated through the ESI, and the ESI lifecycle. It provides context for the Department of Energy’s (DOE’s) Grid Modernization Laboratory Consortium (GMLC) to engage industry participants in the development of the ESI specification. To do this, it describes the desired contents of the ESI specification and provides examples of the type of material that needs to be included in it. The purpose of the ESI specification is to define the requirements that are to be addressed in information and communications technology (ICT) interface standards for enabling the integration of a facility containing responsive distributed energy resources (DER facility) to an electric system consistent with the fundamental ESI principles. In this context, a DER facility may consist of a single DER with a communicating controller or may be as complex as a microgrid campus with several buildings and many DERs. The ESI specification is not a technical interface standard, but the requirements in the specification can be used to check that existing, augmented, or new interface standards meet the interoperability requirements of the ESI concept, which is explained further in this document. In this way, the ESI specification can be used to guide standards advancement work in multiple standards development organizations. To explain the scope of the ESI specification, this ESI requirements document provides examples of situations (or illustrative applications) for using an ESI to coordinate DER flexibility for grid operations. These examples originate from foundational work for describing common grid-DER service agreements that are anticipated to be supported using this interface.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Device-Centric Ransomware Detection using Machine Learning-Based Memory Forensics for Smart Inverters

Ransomware attacks are the fastest-growing form of cyberattacks worldwide. Recently, ransomware attacks have targeted industrial control systems (ICSs), including power grids. Lessons learned from recent incidents in ICSs show that ransomware groups can deliver ransomware into not only the organization’s control servers, but also the operational technology (OT) devices such as smart inverters and smart grid devices. This paper proposes a machine learning (ML)- based memory forensics method enabling the detection of ransomware binaries stored in the memory of a commercial smart inverter. Device firmware binary files are extracted from a Serial Peripheral Interface (SPI) flash memory, and samples of both benign and ransomware binaries are generated by a binary manipulation method and a real-world ransomware encryption, separately. A deep transfer learning (DTL) method is used to retrain a convolutional neural network (CNN)-based ransomware detection algorithm using the generated samples. The experimental result validates that the proposed ML-based memory forensics method can accurately detect ransomware files.

97 MATHEMATICS AND COMPUTING↗

Integrating System to Edge-of-Network Architecture and Management for SHINES (SEAMS) Technologies of High Penetration Grids

Consistent with the U.S. DOE’s EERE SHINES FOA objectives, the goal of this project was to enable integration from EMS to variable DER in a way that delivered visibility and opportunities for managing and controlling distributed resources using SEAMS technologies. This project implemented several SHINES technologies, which included: (1) three Stem battery systems; (2) six ConnectDER PV collars; (3) two E-Gear PV/Battery storage interfaces; and (4) eight Kitu smart inverter emulators. A Siemens Energy IP DEMS was deployed in a development environment and integrated with the SHINES technologies via OpenADR and IEEE 2030.5 protocols with documented architecture. In the case of IEEE 2030.5, a suite of technologies including a gateway, an API, software and a server from Kitu Systems (the Citadel, Convoy, Kitu Crosslink API, and Kitu Spark) were used to demonstrate that the utility could achieve visibility of distributed energy resources (DER) and control of single and multiple DER systems with a single command. The project also included a LCOE analysis of SHINES technologies compared to traditional system and circuit mitigation measures.

14 SOLAR ENERGY↗

Parallel Grid-Forming Inverter-Driven Black Start: Power-Hardware-in-the-Loop Validation: Preprint

With power systems encountering increasing deployment levels of inverter-based resources (IBRs), system restoration using grid-forming (GFM) IBRs has gained attention. Engineered to establish grid voltages in the absence of a stiff grid, black-start-capable GFM IBRs are expected to enhance power system resilience by playing a critical role in bottom-up system restoration. This paper experimentally studies the feasibility of the novel approach through power-hardware-in-the-loop (PHIL) testing and validation with a commercial GFM inverter. The PHIL test setup demonstrates an inverter-driven black start of a 5-MW unbalanced distribution feeder where two GFM inverters collectively black start the feeder: one is a commercial hardware GFM inverter interacting through the PHIL interface, and the other is a software GFM emulated by a real-time simulation with full electromagnetic transient (EMT) models. Both GFM inverters are equipped with negative-sequence voltage control to suppress the voltage imbalance resulting from the unbalanced loading, allowing us to study the dynamic interactions between the GFMs with their control parameters unknown. To evaluate the dynamic behavior of the GFM inverters under the entire black-start process, the EMT model of the distribution system details the transformer and motor dynamics to emulate their inrush and startup behaviors. It abstracts conventional grid-connected inverter dynamics, i.e., grid-following inverters. Oscilloscope measurements of the hardware GFM inverter are also presented for critical steps. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

NEFTSec: Networked federation testbed for cyber-physical security of smart grid: Architecture, applications, and evaluation

As today's power grid is evolving into a densely interconnected cyber-physical system (CPS), a high fidelity and multifaceted testbed environment is needed to perform cybersecurity experiments in a realistic grid environment. Traditional standalone CPS testbeds lack the ability to emulate complex cyber-physical interdependencies between multiple smart grid domains in a real-time environment. Therefore, there are ongoing research and development (R&D) efforts to develop an interconnected CPS testbed by sharing geographically dispersed testbed resources to perform distributed simulation while analysing simulation fidelity. This paper presents a networked federation testbed for cybersecurity evaluation of today's and emerging smart grid environments. Specifically, it presents two novel testbed architectures, including cyber federation and cyber-physical federation, identifies R&D applications, and also describes testbed building blocks with experimental case studies. It also presents a novel co-simulation interface algorithm to facilitate distributed simulation within cyber-physical federation. The resources available at the PowerCyber CPS security testbed at Iowa State University (ISU) and the US Army Research Laboratory are utilised to develop this platform for performing multiple experimental case studies pertaining to wide-area protection and control applications in power system. Finally, experimental results are presented to analyse the simulation fidelity and real-time performance of the testbed federation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Multi-Scale State Estimation Framework for the Next Generation of Power Grid EMS

Accurate system state information under various operation conditions is a prerequisite for power grid monitoring and efficient control. To achieve that goal, a new multi-scale state estimation framework is proposed, paving the way for the development of next generation of energy management system (EMS). The developed framework consists of three key components, namely the static state estimation (SSE) module, the dynamic state estimation (DSE) module, the interfaces and switching logics between the two modules. Specifically, the singular spectrum analysis (SSA)-based change point detection approach is developed to monitor the system continuously. If no event is detected by the SSA, the robust SSE using both SCADA and PMU measurements is executed. Otherwise, the event is declared and the results from SSE are used to derive the initial condition for DSE. During the transient process, only PMU-based DSE is executed for system monitoring and it will be terminated when SSA does not detect any change point of the system. After that, the DSE results are forwarded for SSE initialization and bus voltage magnitude and angle estimations. Simulation results carried out on the IEEE 39-bus system demonstrate the effectiveness and benefits of the proposed framework.

Power system state estimation, energy management s↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

Development of an Atomization Methodology for Spray Combustion

In liquid rocket propulsion, the knowledge and the understanding of liquid-gas interfacial phenomena are very important. This is important for predicting the onset of cavitation occurring in swirl injection elements used in STME, as well as atomization processes in shear-induced injectors (co-axial) and impinging injector elements. From the fact that all the physical processes including droplet size distribution, droplet dispersion, mixing and combustion are controlled by atomization processes, it is expected that the successful incorporation of the volume of fraction (VOF) will greatly enhance the analytical capability of predicting spray combustion processes in liquid-fueled engines. In this paper, a methodology is developed to define and track interfaces between two fluids in non-orthogonal, body-fitted grids using a single fractional volume of fluid (VOF) variable to describe the distribution of the liquid phase in a gas-liquid flow field. This method was implemented in a mature CFD code MAST (Multiphase All-Speed Transient) utilizing the general PISO-C algorithm. For the preliminary study on the analysis of spray combustion and tracking of the interface between two phases, we will report on the progress of the simulation of the instability on the liquid column; the surface wave instability and the droplet breakup from the liquid surface.

Seung, S. P.↗

FUN3D and USM3D Analysis of the Propulsion Aerodynamic Workshop 2018 S-Duct Test Case

This work presents the results of Fun3D and USM3D analyses that were performed for the 4th AIAA Propulsion Aerodynamics Workshop (PAW). The PAW workshop is separated into three sections that focus on internal duct flows, nozzle flows and a special topic. This paper focuses on the internal duct flow section of PAW04 while an accompanying paper discusses the analyses performed for the nozzle portion. For the internal duct flow section, the PAW04 participants were provided with the two configurations consisting of an S-duct with and without aerodynamic interface plane (AIP) rake legs modeled. The participants were asked to perform a grid refinement study as well as a turbulence model study for the configuration with the rake legs. The analyses discussed here were performed on custom grids developed under the guidelines of the workshop. Additionally, the paper discusses the development and use of flow controllers for matching the desired flow characteristics. The results show that both solvers do well for predicting internal flow characteristics of the S-duct based on direct comparison with the experimental data. However, the CFD-to-CFD comparison proved to be more challenging due to the localized occurrence of supersonic flow near the rake legs when using the mass flow controller. A turbulence model study was performed to compare the two-equation SST model to the SA-QCR model. The results show that although the turbulence model does affect the solution, it makes a minimal impact on pressure recovery and inlet distortion intensity for this case. Suggestions for future workshops include gridding guidelines similar to those employed for the Drag Prediction Workshop series for the grid refinement study and a time accuracy study.

Carter, Melissa B.↗

An unwanted guest in the electrochemical oxidation of high-voltage Li-ion battery electrolytes: the life of highly reactive protons

Lithium-ion batteries (LIBs) are central to the urgent societal need to decarbonize both transportation and energy storage on the grid. Unfortunately, despite their attractive energy/power density, as well as high coulombic and energy efficiencies, further improvement of this technology – especially their durability – is desperately needed. To support these efforts, our study focuses on fundamental understanding of the decomposition pathways for LIB electrolytes at the cathode–electrolyte interface (CEI), as the nature of these reactions directly controls the extent to which cell capacity and voltage decays in these systems. In this study, we employ electrochemical methods, coupled with product analysis using NMR spectroscopy and mass spectrometry, to determine the decomposition mechanisms in both model and technologically relevant electrolytes. Remarkably, we discovered the electrochemical formation of protons with high chemical activity, comparable to known superacids, at potentials relevant to practical Li-ion batteries. Their reactivity toward every individual component of the CEI provides a unified thermochemical origin for a myriad of side reactions that are commonly associated with the electrochemical reaction. In particular, electrochemically generated protons react with intact EC molecules to form CO 2 and other short and long chain ethers. They also undergo an acid–base reaction with LiPF 6 , to form the weaker acid HF, and with the cathode active material, leaching transition metals into the electrolyte. Collectively, the results of this study all point to the urgent need to either mitigate this proton formation or introduce benign harvesting additives via new electrolyte design strategies.

Ilic, Stefan [Argonne National Laboratory (ANL), A↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Computation of solid/liquid phase change including free convection - Comparison with data

A computational model is presented for solid/liquid phase-change energy transport including free convection fluid flow in the liquid phase. The computational model considers the velocity components of all nonliquid control volumes to be zero but fully solves the coupled mass-momentum problem within the liquid. The thermal energy model includes the entire domain and employs an enthalpy-like model and a recently developed method for handling the phase-change interface nonlinearity. Convergence studies are performed and comparisons made with experimental data for two different problems. Grid independence is achieved, and the comparison with experimental data indicates excellent quantitative prediction of the melt fraction evolution. Qualitative data are also provided as velocity vector and isotherm plots. The computational costs incurred are quite low by comparison with other models.

Schneider, G. E.↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗