Refrigeration for Cryogenic Sensors

Research in cryogenically cooled refrigerators is discussed. Low-power Stirling cryocoolers; spacecraft-borne long-life units; heat exchangers; performance tests; split-stirling, linear-resonant, cryogenic refrigerators; and computer models are among the topics discussed.

Gasser, M. G.↗

Status of local oscillators for operating ultra-high resolution frequency discriminators as frequency standards

The operation of new improved frequency standards based on new ultra-high-resolution frequency discriminators requires high stability local, or 'flywheel' oscillators. We review the spectral density of phase fluctuations of existing flywheel oscillators and the related time domain frequency stability of new and proposed cryogenically cooled oscillators suitable for this application. Presently used devices include the quartz crystal oscillator, the room-temperature actively oscillating atomic hydrogen (H) maser, and the superconducting maser oscillator. Future devices include the cryogenic H-maser and other cryogenic devices using resonators of superconducting metal or solid crystalline sapphire. The relation of the phase spectral density of these devices to the characteristics of present and proposed frequency discriminators based on trapped cooled ions and cold atoms is discussed in terms of their operation as frequency standards.

Vessot, R. F. C.↗

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

A progress report on using bolometers cooled by adiabatic demagnetization refrigeration

For sensitive detection of astronomical continuum radiation in the 200 micron to 3 mm wavelength range, bolometers are presently the detectors of choice. In order to approach the limits imposed by photon noise in a cryogenically cooled telescope in space, bolometers must be operated at temperatures near 0.1 K. Researchers report progress in building and using bolometers that operate at these temperatures. The most sensitive bolometer had an estimated noise equivalent power (NEP) of 7 x 10(exp 017) W Hz(exp -1/2). Researchers also briefly discuss the durability of paramagnetic salts used to cool the bolometers.

Lesyna, L.↗

Design of a precision etalon position control system for a cryogenic spectrometer

The Upper Atmosphere Research Satellite (UARS) will be launched in 1988 to study the distribution of a series of trace elements in the upper atmosphere and to study atmospheric dynamics. The UARS carries on board a cryogenically cooled infrared spectrometer to measure the concentration of a series of chemical species that are important for understanding the ozone layer in the stratosphere. This device, known as the Cryogenic Limb Array Etalon Spectrometer (CLAES), uses a multiposition filter wheel combined with tilt-scanned Fabry Perot etalons to obtain the high resolution required for these experiments. The CLAES optical system is sealed in a dewar where it is maintained at cryogenic temperatures by a supply of solid hydrogen. Operating temperatures for CLAES range from 130 K at the entrance aperture to 13 K at the focal plane. The design and test of a special control system using a unique actuator concept to provide position and can control for the CLAES etalon are described. Results of performance tests at cryogenic temperatures simulating the CLAES on-orbit environment are discussed.

Aubrun, J. N.↗

Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Method and apparatus for generating microshells of refractory materials

A system is described for forming accurately spherical and centered fluid-filled shells, especially of high melting temperature material. Material which is to form the shells is placed in a solid form in a container, and the material is rapidly heated to a molten temperature to avoid recrystallization and the possible generation of unwanted microbubbles in the melt. Immediately after the molten shells are formed, they drop through a drop tower whose upper end is heated along a distance of at least one foot to provide time for dissipation of surface waves on the shells while they cool to a highly viscous, or just above melting temperature so that the bubble within the shell will not rise and become off centered. The rest of the tower is cryogenically cooled to cool the shell to a solid state.

Lee, Mark C.↗

(abstract) Simple Spreadsheet Thermal Models for Cryogenic Applications

Self consistent circuit analog thermal models, that can be run in commercial spreadsheet programs on personal computers, have been created to calculate the cooldown and steady state performance of cryogen cooled Dewars. The models include temperature dependent conduction and radiation effects. The outputs of the models provide temperature distribution and Dewar performance information. These models have been used to analyze the Cryogenic Telescope Test Facility (CTTF). The facility will be on line in early 1995 for its first user, the Infrared Telescope Technology Testbed (ITTT), for the Space Infrared Telescope Facility (SIRTF) at JPL. The model algorithm as well as a comparison of the model predictions and actual performance of this facility will be presented.

cryogenic thermal model cryostat SIRTF↗

Assessment of Alphamagnetic Spectrometer (AMS) Upper Experiment Structural Configuration Shielding Effectiveness Associated with Change from Cryo-Cooled Magnet to Permanent Magnet

In the spring of 2010, the Alpha Magnetic Spectrometer 2 (AMS-02) underwent a series of system level electromagnetic interference control measurements, followed by thermal vacuum testing. Shortly after completion of the thermal vacuum testing, the project decided to remove the cryogenically cooled superconducting magnet, and replace it with the original permanent magnet design employed in the earlier AMS- 01 assembly. Doing so necessitated several structural changes, as well as removal or modification of numerous electronic and thermal control devices and systems. At this stage, the project was rapidly approaching key milestone dates for hardware completion and delivery for launch, and had little time for additional testing or assessment of any impact to the electromagnetic signature of the AMS-02. Therefore, an analytical assessment of the radiated emissions behavioural changes associated with the system changes was requested.

Scully, Robert↗

Noise parameters and light sensitivity of low-noise high-electron-mobility transistors at 300 and 12.5 K

The four noise parameters of cryogenically cooled HEMTs have been investigated. Two different HEMT structures, with and without a spacer layer, were tested. The noise parameters of both structures were similar at room temperature, while they were dramatically different at cryogenic temperatures. The minimum noise temperatures measured at 8.4 GHz were 75 + or 5 K at room temperature and 8.5 + or - 1.5 K at the temperature of 12.5 K. The cryogenic performance is the best ever observed for field-effect transistors.

Pospieszalski, Marian W.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The past 6 years of operation with the NASA Langley 0.3 m transonic cryogenic tunnel (TCT) show that there are no insurmountable problems associated with cryogenic testing with gaseous nitrogen at transonic Mach numbers. The fundamentals of the concept were validated both analytically and experimentally and the 0.3 m TCT, with its unique Reynolds number capability, was used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects were developed and cryogenic tunnel conditions can be set and maintained accurately. Cryogenic cooling by injecting liquid nitrogen directly into the tunnel circuit imposes no problems with temperature distribution or dynamic response characteristics. Experience with the 0.3 m TCT, indicates that there is a significant learning process associated with cryogenic, high Reynolds number testing. Many of the questions have already been answered; however, factors such as tunnel control, run logic, economics, instrumentation, and model technology present many new and challenging problems.

Ray, E. J.↗

Thermal design of a Shuttle infrared telescope facility /SIRTF/

A thermal design concept has been developed for a cryogenically-cooled infrared telescope facility which will be carried aboard the Space Shuttle for missions of 14 to 30 days. Supercitical helium at 6 K is the principal coolant. Auxiliary tanks of superfluid helium at 2 K are utilized to provide additional low-temperature cooling requirements of specific instruments. The preliminary thermal design described enables SIRTF to provide the low-temperature environment for the telescope and instruments, while maintaining thermally-induced optical degradations within acceptable limits with a cryogen utilization rate compatible with weight and volumetric constraints.

Stoll, R.↗

Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation

HEMT-based receiver arrays with excellent noise and scalability are already starting to be manufactured at 100 GHz, but the advances in technology should make it possible to develop receiver modules with even greater operation frequency up to 200 GHz. A prototype heterodyne amplifier module has been developed for operation from 140 to 170 GHz using monolithic millimeter-wave integrated circuit (MMIC) low-noise InP high electron mobility transistor (HEMT) amplifiers. The compact, scalable module is centered on the 150-GHz atmospheric window using components known to operate well at these frequencies. Arrays equipped with hundreds of these modules can be optimized for many different astrophysical measurement techniques, including spectroscopy and interferometry. This module is a heterodyne receiver module that is extremely compact, and makes use of 35-nm InP HEMT technology, and which has been shown to have excellent noise temperatures when cooled cryogenically to 30 K. This reduction in system noise over prior art has been demonstrated in commercial mixers (uncooled) at frequencies of 160-180 GHz. The module is expected to achieve a system noise temperature of 60 K when cooled. An MMIC amplifier module has been designed to demonstrate the feasibility of expanding heterodyne amplifier technology to the 140 to 170-GHz frequency range for astronomical observations. The miniaturization of many standard components and the refinement of RF interconnect technology have cleared the way to mass-production of heterodyne amplifier receivers, making it a feasible technology for many large-population arrays. This work furthers the recent research efforts in compact coherent receiver modules, including the development of the Q/U Imaging ExperimenT (QUIET) modules centered at 40 and 90 GHz, and the production of heterodyne module prototypes at 90 GHz.

Kangaslahti, Pekka P.↗

Cryogenic and thermal design for the Space Infrared Telescope Facility (SIRTF)

The 1-meter class cryogenically cooled Space Infrared Telescope Facility (SIRTF) planned by NASA, is scheduled for a 1992 launch. SIRTF would be deployed from the Shuttle, and placed into a sun synchronous polar orbit of 700 km. The facility has been defined for a mission with a minimum initial lifetime of one year in orbit with mission extension that could be made possible through in-orbit servicing of the superfluid helium cryogenic system, and use of a thermal control system. The superfluid dewar would use an orbital disconnect system for the tank supports, and vapor cooling of the barrel baffle. The transient analysis of the design shows that the superfluid helium tank with no active feedback comes within temperature requirements for the nominal orbital aperture heat load, quiescent instrument, and chopper conditions.

Lee, J. H.↗

Automated Cryocooler Monitor and Control System Software

This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

Britchcliffe, Michael J.↗

Record High Ramping Rates in HTS Based Superconducting Accelerator Magnet

Here we report results of experimental test of the High Temperature Superconductor (HTS) based fast-cycling prototype accelerator magnet capable to operate up to about 300 T/s field ramping rate with some 0.5 T B-field in the magnet gap. The measured upper limit for the cryogenic cooling power required to support magnet conductor operation at high ramping rates indicates great potential for such type of magnets in rapid cycling synchrotrons for neutrino research or acceleration of very short-lived muons. The test magnet design, construction and supporting cryogenic and power systems are briefly described. The magnet's power test results are discussed in terms of a possible upgrade of this magnet design to 2 T B-field, a maximum feasible with super-ferric magnet.

43 PARTICLE ACCELERATORS↗

Cosmological investigations from SIRTF

An overview is presented of the Space Infrared Telescope Facility (SIRTF), a one-meter-class cryogenically-cooled observatory for IR astronomy from space that will be the IR component of NASA's family of Great Observatories. SIRTF will operate at an altitude of 100,000 km and achieve its five year lifetime without the complication of on-orbit cryogenic replenishment and have twice the on-target efficiency that could be realized in LEO. The observations will permit the development of a direct empirical picture of the time evolution of cosmic phenomena, such as evolution of the chemical and stellar content of galaxies and the growth and decay of the quasar population.

Werner, M.↗