Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Thermal performance of a five year lifetime superfluid helium dewar for SIRTF

The Space Infrared Telescope Facility (SIRTF) is a 1 m class cryogenically cooled observatory for infrared astronomy. The SIRTF cryogenic system has to satisfy the five year mission lifetime requirement as well as to provide sufficient cooling for the science instruments and optical system. A 4000 cu dm superfluid helium dewar has been selected for the current baseline cryogenic system which represents the largest superfluid helium dewar proposed to date for a long lifetime space-borne application. This paper discusses the design and predicted performance of the current cryogenic system, as well as its comparison with IRAS and other space-borne superfluid helium dewars currently under development.

Lee, J. H.↗

A Study of the Individual Contributions of Heat Generated by a XRISM/Resolve ADR Stage Magnet and Its Magnetic Shielding

A typical Adiabatic Demagnetization Refrigerator (ADR) has modest cooling power, on the order of a few microwatts. Thus, understanding heat loads going into and generated within the ADR is vital to its efficiency as well as the efficiency of the total cryogenic system of a spacecraft. One of the many sources of heat that effects the total cryogenic system is the parasitic heat due to AC loss in the ADR magnet and hysteretic loss in its magnetic shielding during a ramp. Although the sum of the heat from both of these sources can be measured during the operation of the ADR, the individual contributions are not easily obtainable in situ. Therefore, a study is being conducted to experimentally measure the contributions of the parasitic heat produced during ramping from the magnet only and from the magnet-shield combo. This study will give better inputs to the heat load model of the total cryogenic system being built for the X-Ray Imaging and Spectroscopy Mission (XRISM) slated to launch in 2022.

AC Loss↗

Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

Hastings, L. J.↗

Shuttle cryogenics supply system. Optimization study. Volume 5 B-2, part 1: Appendix programmers manual for math model

An appendix to the programmers manual for the mathematical model pertaining to the design of cryogenic supply systems for spacecraft is presented. The program listing was produced using the EXEC-8 LISTALL processor which lists a file in alphabetical order. Since the processor does not differentiate between subroutines, functions, and procedure definition processors, each subprogram has been relabeled to clearly identify the type of symbolic listing.

Source record↗

Numerical Modeling of Thermofluid Transients During Chilldown of Cryogenic Transfer Lines

The chilldown of fluid transfer lines is an important part of using cryogenic systems such as those found in both ground and space based applications. The chilldown process is a complex combination of both thermal and fluid transient phenomena. A cryogenic liquid flows through a transfer line that is initially at a much higher temperature than the cryogen. Transient heat transfer processes between the liquid and transfer line cause vaporization of the liquid, and this phase change can cause transient pressure and flow surges in the liquid. As the transfer line is cooled, these effects diminish until the liquid reaches a steady flow condition in the chilled transfer line. If these transient phenomena are not properly accounted for in the design process of a cryogenic system, it can lead to damage or failure of system components during operation. For such cases, analytical modeling is desirable for ensuring that a cryogenic system transfer line design is adequate for handling the effects of a chilldown process. The purpose of this paper is to present the results of a numerical model developed using Generalized Fluid System Simulation Program (GFSSP)'s new fluid transient capability in combination with its previously developed thermal transient capability to predict pressure and flow surge in cryogenic transfer lines during a chilldown process. An experiment performed by the National Bureau of Standards (NBS) in 1966 has been chosen as the baseline comparison case for this work. NBS s experimental set-up consisted of a 10.59 cubic foot supply dewar, an inlet valve, and a 200 foot long, in Outside Diameter (OD) vacuum jacketed copper transfer line that exhausted to atmosphere. Three different inlet valves, an in-port ball valve, a 1-in-port globe valve and a 1-in-port gate valve, were used in NBS's experiments. Experiments were performed using both liquid hydrogen and liquid nitrogen as the fluids. The proposed paper will include detailed comparisons of GFSSP's predictions with NBS's experimental results.

Majumdar, Alok↗

Environmental testing of high Tc superconductive thermal isolators for space-borne cryogenic detector systems

Thick films of superconductive material on low thermal conductivity substrates (e.g., yttria-stabilized zirconia and fused silica) are considered as a replacement for the existing electrical connections between the detector array and data acquisition and storage electronics in the cryogenic detector systems being developed by NASA. The paper describes some of the design constraints on the superconducting device and presents results of a preliminary analysis of the effects of vibration, gamma irradiation, and long-term exposure to high vacuum and liquid nitrogen encountered in operating such a device in space.

Wise, Stephanie A.↗

Evaluation of Power Electronic Components and Systems at Cryogenic Temperatures For Space Missions

Power electronic circuits and systems designed for deep space applications and outer planetary exploration are required to operate reliably and efficiently under extreme temperature conditions. This requirement is dictated by the fact that the operational environments associated with some of the space missions would encompass temperatures as low as -183 C. The development and utilization of electronics capable of low temperature operation would not only fulfill the advanced technology requirements, but also would contribute to improving circuit performance, increasing system efficiency, and reducing development and launch costs. These benefits are generally achieved by the improved intrinsic properties of some of the electronic materials at low temperature, reduced device losses, and the elimination of heating elements used in conventional systems at low temperatures. Power electronic circuits are widely used in space power systems in the areas of power management, conditioning, and control. In this work, the performance of certain power electronic components and systems was investigated under low temperature. These include inductors, capacitors, pulse-width-modulation (PWM) controllers, and advanced commercial DC/DC converter modules. Different properties were determined as a function of temperature in the range of 20 C to -140 C, at various current and voltages levels. The experimental procedures along with the experimental data obtained are presented and discussed in this paper.

Elbuluk, Malik E.↗

Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems

To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.

Morehead, Robert L.↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Thermal Performance Testing of Cryogenic Insulation Systems

Efficient methods for characterizing thermal performance of materials under cryogenic and vacuum conditions have been developed. These methods provide thermal conductivity data on materials under actual-use conditions and are complementary to established methods. The actual-use environment of full temperature difference in combination with vacuum-pressure is essential for understanding insulation system performance. Test articles include solids, foams, powders, layered blankets, composite panels, and other materials. Test methodology and apparatus design for several insulation test cryostats are discussed. The measurement principle is liquid nitrogen boil-off calorimetry. Heat flux capability ranges from approximately 0.5 to 500 watts per square meter; corresponding apparent thermal conductivity values range from below 0.01 up to about 60 mW/m- K. Example data for different insulation materials are also presented. Upon further standardization work, these patented insulation test cryostats can be available to industry for a wide range of practical applications.

Fesmire, James E.↗

Integrated System for Health Management and Autonomous Control (ISHM-AC): Development and Application

Autonomous control systems represent a technological barrier from manual and automated operated control systems in an industry wide application. An increase in energy-efficient storage, transfer and use of cryogens and cryogenic propellants on Earth and in space has been observed in space related industries between NASA, government and commercial programs. An increase in efficiency of cryogenic systems demands an increase in the capabilities of the control and monitoring system that manages them. As new technologies are developed for cryogenic systems, complexity and capability increases. The increase in complexities are a natural drive to develop better and more capable health monitoring and control system management. Current research and development efforts lead the Cryogenics Test Laboratory at the Kennedy Space Center to improve its automated control and health monitoring system from a Programmable Logic Control (PLC) based-only system to a fully Integrated System for Health Management (ISHM) - Autonomous Control (AC) capable of performing autonomous operations on a cryogenic propellant transfer system. This ISHM-AC system has been developed and tested by controlling a complete simulated propellant transfer operation. The capabilities and test results of this fully integrated autonomous system for cryogenics propellant transfer operation will be presented in this paper.

Toro, Jaime A.↗

Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system

A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

Cady, E. C.↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Design of a one-year lifetime, spaceborne superfluid helium dewar

The Infrared Astronomical Satellite is an Explorer Mission and a joint venture of the Netherlands, the United Kingdom, and the United States scheduled for launch into earth orbit in 1981. The cryogenic system is a major part of the satellite; it incorporated many unique and state-of-the-art design features to satisfy the requirements of a one-year orbital lifetime, a focal plane temperature less than 4K, minimal launch weight, and zero-gravity operation. The 60-centimeter diameter telescope is contained within a superfluid helium dewar having a capacity of 540 liters. The telescope aperture cover employs an independent cryogenic system containing a 54-liter supercritical helium tank. The aperture cover, which is ejected two weeks after launch, protects the telescope from contamination and provides the low-temperature background needed to perform focal plane health checks. Design and predicted performance of the cryogenic systems are discussed in detail.

Hopkins, R. A.↗