Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenics Test Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Generating Cryogenic Lunar Simulants Within the Planetary Exploration & Astromaterials Research Laboratory

The Planetary Exploration & Astromaterials Research Laboratory (PEARL) aims to provides capabilities for the creation of—and research on—cryogenic lunar regolith simulants (CRS) containing surface volatile analytes. CRS represent regolith samples that might be collected from lunar Permanently Shadowed Regions (PSRs) during future missions. Handling CRS requires procedural and engineering development due to extremely cold (i.e. ≤ - 196°C) working temperatures. However, there is an imperative to understand the physical and chemical alteration of samples during collection, transport, and curation processes throughout the Artemis missions. The chemistries that will be encountered within the PSRs need to be understood based upon prior mission data analysis. The ability to utilize these techniques provides future tests that could be relevant to planetary protection applications regarding future robotic sample return.

Lunar↗

Use of Capillaries for Macromolecular Crystallization in a Cryogenic Dewar

The Enhanced Gaseous Nitrogen (EGN) Dewar is a cryogenic dry shipper with a sealed cylinder inserted inside along with a temperature-monitoring device, and is intended for macromolecular crystallization experiments on the International Space Station. Within the Dewar, each crystallization experiment is contained as a solution within a plastic capillary. The standard procedure for loading samples in these tubes has involved rapid freezing of the precipitant and biomolecule solution directly in liquid nitrogen; this method, however, often results in uncontrolled formation of air voids. These air pockets, or bubbles, then can lead to irreproducible crystallization results. A novel protocol has been developed to prevent formation of bubbles, and this has been tested in the laboratory as well as aboard the International Space Station during a 42-day long mission of July/August of 2001. Furthermore, gain or loss of mass from solutions within the capillaries revealed that mass transport amongst separated tubes occurred, and that this mass transport was determined by the hygroscopic character of a solution contained in any given tube. The sample volume and the surface area of the plastic capillary tube also related to the observed mass transport.

Ciszak, Ewa↗

Use of Capillaries for Macromolecular Crystallization in a Cryogenic Dewar

The enhanced gaseous nitrogen (EGN) dewar is a cryogenic dry shipper with a sealed cylinder inserted inside along with a temperature monitoring device, and is intended for macromolecular crystallization experiments on the International Space Station. Within the dewar, each crystallization experiment is contained as a solution within a plastic capillary tube. The standard procedure for loading samples in these tubes has involved rapid freezing of the precipitant and biomolecular solution, e.g., protein, directly in liquid nitrogen; this method, however, often resulted in uncontrolled formation of air voids, These air pockets, or bubbles, can lead to irreproducible crystallization results. A novel protocol has been developed to prevent formation of bubbles, and this has been tested in the laboratory as well as aboard the International Space Station during a 42-day long mission of July/August 2001. The gain or loss of mass from solutions within the plastic capillaries revealed that mass transport occurred among separated tubes, and that this mass transport was dependent upon the hygroscopic character of the solution contained in any given tube. The surface area of the plastic capillary tube also related to the observed mass transport. Furthermore, the decreased mass of solutions of-protein correlated to observed formation of protein crystals.

Ciszak, Ewa↗

Progress Made in Lunar In-Situ Resource Utilization Under NASA's Exploration Technology and Development Program

Incorporation of In-Situ Resource Utilization (ISRU) and the production of mission critical consumables for 9 propulsion, power, and life support into mission architectures can greatly reduce the mass, cost, and risk of missions 10 leading to a sustainable and affordable approach to human exploration beyond Earth. ISRU and its products can 11 also greatly affect how other exploration systems are developed, including determining which technologies are 12 important or enabling. While the concept of lunar ISRU has existed for over 40 years, the technologies and systems 13 had not progressed much past simple laboratory proof-of-concept tests. With the release of the Vision for Space 14 Exploration in 2004 with the goal of harnessing the Moon.s resources, NASA initiated the ISRU Project in the 15 Exploration Technology Development Program (ETDP) to develop the technologies and systems needed to meet 16 this goal. In the five years of work in the ISRU Project, significant advancements and accomplishments occurred in 17 several important areas of lunar ISRU. Also, two analog field tests held in Hawaii in 2008 and 2010 demonstrated 18 all the steps in ISRU capabilities required along with the integration of ISRU products and hardware with 19 propulsion, power, and cryogenic storage systems. This paper will review the scope of the ISRU Project in the 20 ETDP, ISRU incorporation and development strategies utilized by the ISRU Project, and ISRU development and 21 test accomplishments over the five years of funded project activity.

Sanders, Gerald B.↗

A Flight Demonstration of Plasma Rocket Propulsion

The Advanced Space Propulsion Laboratory at the Johnson Space Center has been engaged in the development of a magneto-plasma rocket for several years. This type of rocket could be used in the future to propel interplanetary spacecraft. One advantageous feature of this rocket concept is the ability to vary its specific impulse so that it can be operated in a mode which maximizes propellant efficiency or a mode which maximizes thrust. This presentation will describe a proposed flight experiment in which a simple version of the rocket will be tested in space. In addition to the plasma rocket, the flight experiment will also demonstrate the use of a superconducting electromagnet, extensive use of heat pipes, and possibly the transfer of cryogenic propellant in space.

Petro, Andrew↗

Electrostatic Discharges from Conductive Thermal Coatings

Selecting the correct thermal control coating for a spacecraft can be a significant challenge. From the start, the process includes balancing conflicting needs. Thermal control paints must have the ability to either absorb or emit heat as desired and this property cannot change beyond a set point over the life of the mission. When the mission involves operating in a heavy charging environment, the control coating must be static dissipative enough to bleed away absorbed energetic electrons to minimize induced electric fields and the risk of electrostatic discharges. Finding the right balance of thermal performance and electrical performance can be difficult for spacecraft designers. In an effort to aid in spacecraft design, a number of white and black thermal control coatings were tested at the Jet Propulsion Laboratory using a two-part test campaign. These tests involved an initial screening test to determine the bulk resistivity of the material using a traditional parallel plate test, but placed in a vacuum chamber immersed in a bath of liquid nitrogen to obtain data over a range of temperatures. The most promising materials were then exposed to a stream of energetic electrons and monitored for the production of electrostatic discharges. Results from these tests indicated that only a few of the common thermal control coatings have a resistivity below 109 ohm-cm as suggested in NASA-HDBK-4002A. Of those that meet this criterion, most will still produce electrostatic discharges when exposed to electrons with energies from 20keV to 60keV while held at cryogenic temperatures. Additional testing is required to characterize additional coatings to create a database that designers may use when selecting an appropriate coating for their application.

Chinn, James↗

Update on Planetary, Lunar, & Asteroid Natural Environment Testbed (PLANET)

At ISMSE15, the Planetary, Lunar, & Asteroid Natural Environment Testbed (PLANET) was introduced as an upcoming high-fidelity, combined-effects planetary surface environment laboratory. This year, we will present an update on the facility status, describing the procurement, installation, commissioning of the chamber in Huntsville, Alabama (USA). With NASA’s push to return to the Moon through the Artemis program, there is a clear need for more high-fidelity test chambers that can replicate multiple aspects of the lunar surface, especially the fine, dusty lunar soil known as regolith. The PLANET chamber is designed to fill this gap, enabling research & development, qualification, and verification testing in a combined lunar surface environment, at an affordable price, for government, commercial/industry, and academic partners. Features include a large regolith simulant bed, low energy electron and ion sources to replicate the solar wind, full-spectrum UV and Solar simulation, and a liquid nitrogen cryogenic shroud, all in a high-vacuum environment (as low as 10^-7 mbar). PLANET’s initial focus will be on the lunar environment, but other surface environments (Martian, asteroid, etc.) are also possible to simulate. Besides the environmental instrumentation, PLANET will be equipped with specialized test systems that the Space Environmental Effects Team has developed over the past two years, including an in-situ tribometer and uniform dust distribution system. The chamber is currently being manufactured, with plans to install in May 2024. This will be followed by outfitting and commissioning. The challenges and accomplishments seen during this process will be detailed, and data from the first tests performed in PLANET will be shared with the community.

environmental testing↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

The Low Temperature Microgravity Physics Experiments Project

The Low Temperature Microgravity Physics Facility (LTMPF) is being developed by NASA to provide long duration low temperature and microgravity environment on the International Space Station (ISS) for performing fundamental physics investigations. Currently, six experiments have been selected for flight definition studies. More will be selected in a two-year cycle, through NASA Research Announcement. This program is managed under the Low Temperature Microgravity Physics Experiments Project Office at the Jet Propulsion Laboratory. The facility is being designed to launch and returned to earth on a variety of vehicles including the HII-A and the space shuttle. On orbit, the facility will be connected to the Exposed Facility on the Japanese Experiment Module, Kibo. Features of the facility include a cryostat capable of maintaining super-fluid helium at a temperature of 1.4 K for 5 months, resistance thermometer bridges, multi-stage thermal isolation system, thermometers capable of pico-Kelvin resolution, DC SQUID magnetometers, passive vibration isolation, and magnetic shields with a shielding factor of 80dB. The electronics and software architecture incorporates two VME buses run using the VxWorks operating system. Technically challenging areas in the design effort include the following: 1) A long cryogen life that survives several launch and test cycles without the need to replace support straps for the helium tank. 2) The minimization of heat generation in the sample stage caused by launch vibration 3) The design of compact and lightweight DC SQUID electronics. 4) The minimization of RF interference for the measurement of heat at pico-Watt level. 5) Light weighting of the magnetic shields. 6) Implementation of a modular and flexible electronics and software architecture. The first launch is scheduled for mid-2003, on an H-IIA Rocket Transfer Vehicle, out of the Tanegashima Space Center of Japan. Two identical facilities will be built. While one facility is onboard the ISS, the other is re-integrated on the ground with new experiments. When the cryogen of the facility in space are exhausted, it will be swapped with the other facility with the new experiment. A total of 20 science missions are envisioned over the next 20 years.

Holmes, Warren↗

Investigation of Vapor Cooling Enhancements for Applications on Large Cryogenic Systems

The need to demonstrate and evaluate the effectiveness of heat interception methods for use on a relevant cryogenic propulsion stage at a system level has been identified. Evolvable Cryogenics (eCryo) Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) will be designed with vehicle specific geometries (SLS Exploration Upper Stage (EUS) as guidance) and will be subjected to simulated space environments. One method of reducing structure-born heat leak being investigated utilizes vapor-based heat interception. Vapor-based heat interception could potentially reduce heat leak into liquid hydrogen propulsion tanks, increasing potential mission length or payload capability. Due to the high number of unknowns associated with the heat transfer mechanism and integration of vapor-based heat interception on a realistic large-scale skirt design, a sub-scale investigation was developed. The sub-project effort is known as the Small-scale Laboratory Investigation of Cooling Enhancements (SLICE). The SLICE aims to study, design, and test sub-scale multiple attachments and flow configuration concepts for vapor-based heat interception of structural skirts. SLICE will focus on understanding the efficiency of the heat transfer mechanism to the boil-off hydrogen vapor by varying the fluid network designs and configurations. Various analyses were completed in MATLAB, Excel VBA, and COMSOL Multiphysics to understand the optimum flow pattern for heat transfer and fluid dynamics. Results from these analyses were used to design and fabricate test article subsections of a large forward skirt with vapor cooling applied. The SLICE testing is currently being performed to collect thermal mechanical performance data on multiple skirt heat removal designs while varying inlet vapor conditions necessary to intercept a specified amount of heat for a given system. Initial results suggest that applying vapor-cooling provides a 50 heat reduction in conductive heat transmission along the skirt to the tank. The information obtained by SLICE will be used by the SHIIVER engineering team to design and implement vapor-based heat removal technology into the SHIIVER forward skirt hardware design.

small scale testing↗

A preliminary study of a cryogenic equivalence principle experiment on Shuttle

The Weak Equivalence Principle is the hypothesis that all test bodies fall with the same acceleration in the same gravitational field. The current limit on violations of the Weak Equivalence Principle, measured by the ratio of the difference in acceleration of two test masses to their average acceleration, is about 3 parts in one-hundred billion. It is anticipated that this can be improved in a shuttle experiment to a part in one quadrillion. Topics covered include: (1) studies of the shuttle environment, including interference with the experiment, interfacing to the experiment, and possible alternatives; (2) numerical simulations of the proposed experiment, including analytic solutions for special cases of the mass motion and preliminary estimates of sensitivity and time required; (3) error analysis of several noise sources such as thermal distortion, gas and radiation pressure effects, and mechanical distortion; and (4) development and performance tests of a laboratory version of the instrument.

Everitt, C. W. F.↗

Real Time Nitrogen Monitoring and Quality Control System for NASA Astromaterials Collection

The Nitrogen system is a vital utility supporting the curation office within NASA's Astromaterials Re-search and Exploration Science (ARES) Division at the Johnson Space center (JSC). Since the Apollo samples were returned in 1969. It has played an essential role in preserving NASA’s astromaterial collections (now nine collections) by maintaining contamination-free, controlled environments required for long term curation and advanced scientific research. To meet the stringent purity requirements for contamination control, high purity modified Grade C Liquid Nitrogen (LN2) is delivered weekly by an industrial gas vendor to a 15,000-gallon tank located outside at NASA JSC near the ARES facility. This nitrogen is vital for creating an inert atmosphere to store the collection in, ensuring they are continuously shielded from contaminants and alterations through a constant N2purge. For most of the past 65 years deliveries of LN2 have required a CoA (Certificate of Analysis) prior to delivery. If those were not available, then LN2 deliver were sent to third-party laboratories for verification, creating an operational bottleneck and quality gap. To address this challenge and maintain rigorous quality control, NASA JSC Infrastructure and Astromaterials Acquisition & Curation Office initiated the development of an on-site Analytical Gas Sampling (AGS) Laboratory. Designed to streamline quality verification if a CoA unavailable, the AGS lab was constructed by a subcontractor in Newton, NJ. After a successful factory acceptance test conducted by the NASA ARES Infrastructure team, the lab was trans-ported to NASA JSC, where it was anchored and integrated into the site’s nitrogen pressure system using stainless steel, oxygen-cleaned tubing. The ARES nitrogen system was modified to provide parallel flows to the AGS lab for quality control and to the astromaterials collection labs for maintaining an inert environment. The AGS lab features two operational modes: (1)Primary: Gaseous Nitrogen (GN2) Quality Monitoring –The AGS system continuously samples the site’s GN2 supply every 15 minutes to ensure compliance with required purity levels. (2) Secondary: LN2 Quality Verification when a comprehensive CoA is not available, a cryogenic vaporizer converts LN2 to GN2, which is then analyzed for impurities: H₂, Ar, O₂, CO, CO₂, H₂O, and total hydrocarbons (THC). By significantly enhancing on-site analytical capabilities, the AGS lab eliminates reliance on external testing, ensures uninterrupted quality monitoring of the nitrogen pressure system, and reinforces NASA’s commitment to preserving pristine astromaterials under the highest standards of curation and research integrity.

glove box↗

SSME Propellant Path Leak Detection

The complicated high-pressure cycle of the space shuttle main engine (SSME) propellant path provides many opportunities for external propellant path leaks while the engine is running. This mode of engine failure may be detected and analyzed with sufficient speed to save critical engine test hardware from destruction. The leaks indicate hardware failures which will damage or destroy an engine if undetected; therefore, detection of both cryogenic and hot gas leaks is the objective of this investigation. The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-the-art technology infrared (IR) thermal imaging systems combined with computer, digital image processing, and expert systems for the engine protection. The feasibility of IR leak plume detection is evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application.

Roger Crawford↗

Applications of Advanced, Waveform Based AE Techniques for Testing Composite Materials

Advanced, waveform based acoustic emission (AE) techniques have been previously used to evaluate damage progression in laboratory tests of composite coupons. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite structures, the effects of wave propagation over larger distances and through structural complexities must be well characterized and understood. In this research, measurements were made of the attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels. As these materials have applications in a cryogenic environment, the effects of cryogenic insulation on the attenuation of plate mode AE signals were also documented.

Prosser, William H.↗

Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft

Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.

Apel, Eric C.↗

Development of a quiet supersonic wind tunnel with a cryogenic adaptive nozzle

Low-disturbance or 'quiet' wind tunnels are now considered an essential part of meaningful boundary layer transition research. Advances in Supersonic Laminar Flow Control (SLFC) technology for swept wings depends on a better understanding of the receptivity of the transition phenomena to attachment-line contamination and cross-flows. This need has provided the impetus for building the Laminar Flow Supersonic Wind Tunnel (LFSWT) at NASA-Ames, as part of the NASA High Speed Research Program (HSRP). The LFSWT was designed to provide NASA with an unequaled capability for transition research at low supersonic Mach numbers (<2.5). The following are the objectives in support of the new Fluid Mechanic Laboratory (FML) quiet supersonic wind tunnel: (I) Develop a unique injector drive system using the existing FML indraft compressor; (2) Develop an FML instrumentation capability for quiet supersonic wind tunnel evaluation and transition studies at NASA-Ames; (3) Determine the State of the Art in quiet supersonic wind tunnel design; (4) Build and commission the LFSWT; (5) Make detailed flow quality measurements in the LFSWT; (6) Perform tests of swept wing models in the LFSWT in support of the NASA HSR program; and (7) Provide documentation of research progress.

Wolf, Stephen W. D.↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

High-Lift Flight Tunnel - Phase II Report

The High-Lift Flight Tunnel (HiLiFT) concept is a revolutionary approach to aerodynamic ground testing. This concept utilizes magnetic levitation and linear motors to propel an aerodynamic model through a tube containing a quiescent test medium. This medium (nitrogen) is cryogenic and pressurized to achieve full flight Reynolds numbers higher than any existing ground test facility world-wide for the range of 0.05 to 0.50 Mach. The results of the Phase II study provide excellent assurance that the HiLiFT concept will provide a valuable low-speed, high Reynolds number ground test facility. The design studies concluded that the HiLiFT facility is feasible to build and operate and the analytical studies revealed no insurmountable difficulties to realizing a practical high Reynolds number ground test facility. It was determined that a national HiLiFT facility, including development, would cost approximately $400M and could be operational by 2013 if fully funded. Study participants included National Aeronautics and Space Administration Langley Research Center as the Program Manager and MSE Technology Applications, Inc., (MSE) of Butte, Montana as the prime contractor and study integrator. MSE#s subcontractors included the University of Texas at Arlington for aerodynamic analyses and the Argonne National Laboratory for magnetic levitation and linear motor technology support.

Lofftus, David↗