Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Accelerated Aging and Evaluation of Hose-In-Hose Transfer Lines in the Hanford Waste Transfer System - 20312

Nonmetallic materials are used in the United States Department of Energy's Hanford Site Tank Farm waste transfer system. These materials include the inner primary hoses in the hose-in-hose transfer lines (HIHTLs), Garlock{sup R} gaskets, ethylene propylene diene monomer (EPDM) O-rings, and other nonmetallic materials. These nonmetallic materials are exposed to β and γ radiation, caustic solutions as well as high temperature and pressure stressors. How the nonmetallic components react to each of these stressors individually has been well established. However, simultaneous exposure of these stressors has not been evaluated and is of great concern to Hanford Site engineers. Florida International University's Applied Research Center engineers worked closely with key Hanford's Washington River Protection Solutions personnel to develop an experimental test plan that determines how these nonmetallic components react to various simultaneous stressor exposures. In this paper, research on the experimental testing of the hose-in-hose transfer lines used in the Hanford tank farm waste transfer system under simultaneous stressor exposures is presented. The stressor exposure experiments consisted of various combinations of simultaneous stressor exposure of caustic solution, high temperature and high pressure stressors. Research efforts focused on evaluating the aging behavior of EPDM by exposing samples of HIHTLs as well as EPDM dog bone shaped specimens to a 25% NaOH solution at (38 deg. C), operating (54 deg. C) and design temperatures (77 deg. C) for 6 months and 12 months. In addition, HIHTL and the EPDM dog-bone specimens were exposed to only hot water at 77 deg. C for a duration of one year. The mechanical and material properties of the samples were characterized and compared with those of the unexposed samples (baseline). Evaluations included burst pressure tests of the EPDM hose-in-hose transfer lines and material tensile strength test of EPDM dog-bone coupons. Both the tensile strength of the EPDM material dog bones and the burst pressure of the HIHTLs significantly decreased with the increasing temperature and increasing exposure time. When compared with the baseline samples, the burst pressure decreased by 28.75% for the sample aged at 77 deg. C after 12 months, in comparison to sample aged at 38 deg. C and 54 deg. C which had about 1.34% and 5.70% loss in burst pressures, respectively, after 12-month exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.

Non-NASA Center↗

Exercise thermoregulation with bed rest, confinement, and immersion deconditioning

Altered thermoregulation following exposure to prolonged (12-14 days) of bed rest and 6 hr of head-down thermoneutral water immersion in humans, and cage confinement (8 weeks) in male, mongrel dogs resulted in occasional increased core temperature (Tcore) at rest, but consistent "excessive" increase in Tcore during submaximal exercise. This excessive increase in Tcore in nonexercising and exercising subjects was independent of the mode (isometric or isotonic) of exercise training during bed rest, and was associated with the consistent hypovolemia in men but not in women taking estrogen supplementation (1.25 mg premarin/ day) which restored plasma volume during bed rest to ambulatory control levels. Post-bed rest exercise sweating (evaporative heat loss) was unchanged or higher than control levels; however, calculated tissue heat conductance was significantly lower in men, and forearm venoconstriction was greater (venous volume was reduced) in women during exercise after bed rest. Because sweating appeared proportional to the increased level of Tcore, these findings suggest that one major factor for the excessive hyperthermia is decreased core to periphery heat conduction. Exercising dogs respond like humans with excessive increase in both rectal (Tre) and exercising muscle temperatures (Tmu) after confinement and, after eight weeks of exercise training on a treadmill following confinement, they had an attenuated rate of increase of Tre even below ambulatory control levels. Intravenous infusion of glucose also attenuated not only the rise in Tre during exercise in normal dogs, but also the excessive rise in Tre and exercising Tmu after confinement. Oral glucose also appeared to reduce the rate of increase in excessive Tre in men after immersion deconditioning. There was a greater rate of rise in Tcore in two cosmonauts during supine submaximal exercise (65% VO2 max) on the fifth recovery day after the 115-day Mir 18 mission. Thus, the excessive rise in core temperature after deconditioning appears to be caused by decreased peripheral vasodilation in humans. Factors related to glucose metabolism may influence this mechanism.

NASA Program Space Physiology and Countermeasures↗

Effect of body repositioning after venous air embolism. An echocardiographic study

BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

NASA Discipline Environmental Health↗

Quantifying the resistance to dislocation glide in single phase FeCrAl alloy

The resistance to dislocation glide associated with slip systems {110}<111> and {112}<111> in single phase FeCrAl alloy is measured via micromechanical testing in a scanning electronic microscopy at room temperature. Two important factors, the shape and orientation of a pillar, are discussed with respect to the glide resistance and stress-strain response. Maximizing Schmid factor of one specific slip system while minimizing others is recommended in order to diminish obvious dislocations-induced hardening during in-situ testing. Apparent Schmid factor analysis is conducted to select grains with preferred orientations. Two types of pillars with conventional cylindrical shape or dog-bone shape are tested under compression to estimate the resistance to dislocation glide and evaluate the effect of pillar shape on the compression stress-strain response. One dog-bone pillar is tested under tension to check the tension-compression isotropy of dislocation slip. We discover that the shape of a pillar to a smaller extent affects the measured resistance but strongly influences the stress strain response. Cylindrical pillars exhibit apparent hardening associated with early yielding due to stress or strain concentration at contact region, while dog-bone pillars show an obvious yielding and continuous shearing without hardening. The resistance is 220 MPa for slip system {110}<111> and 230 MPa for slip system {112}<111>. Finite element analysis is performed to account for the influence of pillar shape and contact condition on mechanical response.

36 MATERIALS SCIENCE↗

First report of Staphylococcus pseudintermedius ST71-SCCmec III and ST45-ΨSCCmec57395 from canine pyoderma in Argentina

Abstract Staphylococcus pseudintermedius is an opportunistic pathogen commonly associated with skin infections in dogs. Twenty-three methicillin-resistant S. pseudintermedius (MRSP) isolated in Argentina from dogs with pyoderma were analyzed using whole genome sequencing (WGS) and classified into sequence types (ST) by multilocus sequence typing (MLST) and staphylococcal chromosome cassette mec (SCC mec ) types. Based on the WGS analysis, MLST, and SCC mec type results, we report for the first time in Argentina two MRSP strains, one each, belonging to ST71-SCC mec III and ST45-ΨSCC mec 57395 from dogs with pyoderma. We also identified seven isolates with ST339, which had been previously reported in only two isolates in Argentina. Additionally, we identified ten MRSP isolates harboring variants of the SCC mec V found in S. aureus , seven SCC mec V (5C2&5) with two ccr C1 recombinases, and three SCC mec V (5C2) with one ccr C1 recombinase. Our findings provide important insights into the evolution and geographic spread of these hypervirulent dominant clones that threaten the health of our companion animals and represent a significant risk for zoonotic infections.

Srednik, Mariela E.↗

Continuous animal exposure to dichloromethane

Continuous exposures of dogs, monkeys, rats and mice to 5000 ppm and 1000 ppm of dichloromethane vapor (CH2Cl2) produced severe toxic effects on dogs, rats and mice. Dogs died after 3 weeks exposure to 1000 ppm and after 6 weeks exposure to 5000 ppm. Thirty percent of the mice also succumbed during four weeks exposure to 5000 ppm CH2Cl2. Although rats survived 14 weeks exposure to 5000 ppm, they experienced subnormal weight gains. Significant gross and histopathological hepatic lesions were noted in all 3 species at death or experimental termination in 14 weeks. In addition, rats showed abnormal kidney histopathology. Fat stains disclosed mild fatty increase in monkey livers after 14 weeks exposure to 1000 ppm CH2Cl2.

Macewen, J. D.↗

Role of distal reabsorption and peritubular environment in glomerulotubular balance.

Total kidney glomerulotubular balance was examined during aortic constriction and release in saline-loaded dogs and in dogs undergoing water diuresis. Aortic constriction lowered the glomerular filtration rate by 45% in both groups, and glomerulotubular balance, as judged by changes in absolute sodium reabsorption, was also comparable. During water diuresis, a linear relationship was observed between free water clearance and urine flow during all maneuvers, suggesting that distal sodium reabsorption is related primarily to distal delivery. The results suggest that if alterations in the peritubular environment are responsible for the changes in tubular sodium reabsorption during aortic constriction in the saline- or water-loaded dog, then a change in renal plasma flow, and presumably delivery rate of oncotic force, may be the most likely mediator.

Schrier, R. W.↗

Vascular pressures and passage of gas emboli through the pulmonary circulation

Doppler technique was used to measure the pulmonary vascular pressure gradients in dogs that received venous air emboli (VAE) at the rate of 0.35 ml/kg per min, at which the spillover of bubbles into the systemic arteries occur. It was found that, in 60 percent of dogs, venous bubbles spilled over into the arterial circulation at the pulmonary vascular pressure gradient of about 34.7 mm Hg. When the pulmonary vascular pressure gradient was raised to about 52 mm Hg, the spillover of venous bubbles occurred 100 percent of time. It is concluded that venous bubbles can cross the lungs of anesthetized dogs when the driving pressures are sufficient to overcome the normal filtering function.

Butler, B. D.↗

Abnormal Canine Bone Development Associated with Hypergravity Exposure

Chronic centrifugation of 85- to 92-day-old Beagles at 2.0 x g and 2.6 x g for 26 weeks during the time of active skeletal growth caused skeletal abnormalities in the radius and the ulna of ten of 11 dogs. The pattern of change mimicked that found in naturally occurring and experimentally induced premature distal ulnar physeal closure or delayed growth at this physis. Minimal changes in bone density were detected by sensitive photon absorptiometric techniques. Skeletal abnormalities also were found in five of the six cage-control dogs, although the run-control dogs were radiographically normal.

Morgan, J. P.↗

Arthromitus (Bacillus cereus) symbionts in the cockroach Blaberus giganteus: dietary influences on bacterial development and population density

The filamentous spore-forming bacterium Arthromitus, discovered in termites, millipedes, sow bugs and other soil-dwelling arthropods by Leidy (1850), is the intestinal stage of Bacillus cereus. We extend the range of Arthromitus habitats to include the hindgut of Blaberus giganteus, the large tropical American cockroach. The occurrence and morphology of the intestinal form of the bacillus were compared in individual cockroaches (n=24) placed on four different diet regimes: diurnally maintained insects fed (1) dog food, (2) soy protein only, (3)purified cellulose only, and (4) a dog food-fed group maintained in continuous darkness. Food quality exerted strong influence on population densities and developmental stages of the filamentous bacterium and on fecal pellet composition. The most dramatic rise in Arthromitus populations, defined as the spore-forming filament intestinal stage, occurred in adult cockroaches kept in the dark on a dog food diet. Limited intake of cellulose or protein alone reduced both the frequency of Arthromitus filaments and the rate of weight gain of the insects. Spores isolated from termites, sow bugs, cockroaches and moths, grown on various hard surfaces display a branching mobility and resistance to antibiotics characteristic to group I Bacilli whose members include B. cereus, B. circulans, B. alvei and B. macerans. DNA isolated from pure cultures of these bacilli taken from the guts of Blaberus giganteus (cockroach), Junonia coenia (moth), Porcellio scaber (sow bug) and Cryptotermes brevis (termite) and subjected to Southern hybridization with a 23S-5S B. subtilis ribosomal sequence probe verified that they are indistinguishable from laboratory strains of Bacillus cereus.

NASA Discipline Exobiology↗

Test Results From a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit

The Brayton Power Conversion Unit (BPCU) located at NASA Glenn Research Center (GRC) in Cleveland, OH is a closed cycle system incorporating a turboaltemator, recuperator, and gas cooler connected by gas ducts to an external gas heater. For this series of tests, the BPCU was modified by replacing the gas heater with the Direct Drive Gas heater or DOG. The DOG uses electric resistance heaters to simulate a fast spectrum nuclear reactor similar to those proposed for space power applications. The combined system thermal transient behavior was the focus of these tests. The BPCU was operated at various steady state points. At each point it was subjected to transient changes involving shaft rotational speed or DOG electrical input. This paper outlines the changes made to the test unit and describes the testing that took place along with the test results.

Hervol, David S.↗

An Active Subspace Method for Accelerating Convergence in Delaunay-Based Optimization via Dimension Reduction

Delaunay-based derivative-free optimization, ∆DOGS, is an efficient and provably-convergent global optimization method for the problems which has computationally expensive objection function and the analytical expression for the objective function is not available. ∆-DOGS is a novel optimization scheme in the family of response surface methods (RSMs); however, it suffers from the curse of dimensionality since the computational cost increases dramatically as the number of design parameters increases. As a result, the number of design parameters in ∆-DOGS algorithm is relatively low (n.10). To avoid such problems, this paper proposes a combination of derivative-free optimization, seeking the global minimizer of an expensive and nonconvex objective function f(x) and active subspace method, detecting the directions of the most variability using evaluations of the gradient. The contribution of other directions to the objective function is bounded by a sufficiently small constant. This new algorithm iteratively applied Delaunay-based derivative-free optimization to seek the minimizer on the d-dimensional active subspace that has most function variation. Inverse mapping is needed to project data from active subspace to full-model for evaluating function values. This task is overcome by solving an inequality constrained problem that curves the response surface of the objective function. The test results show that this strategy is effective on a handful of optimization problems.

Bewley, Thomas R.↗

Mechanisms of cardiac hypertrophy in canine volume overload

This study tested whether the modest hypertrophy that develops in dogs in response to mitral regurgitation is due to a relatively small change in the rate of protein synthesis or, alternatively, is due to a decreased rate of protein degradation. After 3 mo of severe experimental mitral regurgitation, the left ventricular (LV) mass-to-body weight ratio increased by 23% compared with baseline values. This increase in LV mass occurred with a small, but not statistically significant, increase in the fractional rate of myosin heavy chain (MHC) synthesis (Ks), as measured using continuous infusion with [3H]leucine in dogs at 2 wk, 4 wk, and 3 mo after creation of severe mitral regurgitation. Translational efficiency was unaffected by mitral regurgitation as measured by the distribution of MHC mRNA in polysome gradients. Furthermore, there was no detectable increase in translational capacity as measured by either total RNA content or the rate of ribosome formation. These data indicate that translational mechanisms that accelerate the rate of cardiac protein synthesis are not responsive to the stimulus of mitral regurgitation. Most of the growth after mitral regurgitation was accounted for by a decrease in the fractional rate of protein degradation, calculated by subtracting fractional rates of protein accumulation at each time point from the corresponding Ks values. We conclude that 1) volume overload produced by severe mitral regurgitation does not trigger substantial increases in the rate of protein synthesis and 2) the modest increase in LV mass results primarily from a decrease in the rate of protein degradation.

Non-NASA Center↗

Effect of temperature and aging duration on ethylene propylene diene monomer (EPDM) nonmetallic components used in caustic liquid waste transfer lines

Nonmetallic materials are used in waste transfer lines at the United States Department of Energy’s Hanford Site Tank Farm in Benton County, Washington, USA. During use, the ethylene propylene diene monomer (EPDM) inner hose of the hose-in-hose transfer lines (HIHTLs) are exposed to β and γ radiation, caustic solutions as well as high temperatures and high pressures. Aging behavior of specimens of EPDM HIHTLs and dog-bone shaped specimens were evaluated by exposing to a solution of 25% sodium hydroxide (NaOH) at 38 °C, 54 °C and 77 °C for 6 and 12-months as well as water only at 77 °C for 12-months. Tensile strength and burst pressure of the specimens were characterized and compared with the unexposed (baseline) specimens. Both the tensile strength of the EPDM material and the burst pressure of the HIHTLs significantly decreased with the higher temperatures and longer exposure times. Analyses using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) of the HIHTLs and the dog-bone specimens were conducted. Our results show that the surface degradation increased with increasing exposure temperature. Penetration of NaOH into the EPDM material also increased with increasing temperature and exposure duration.

36 MATERIALS SCIENCE↗

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

304L stainless steel↗

Predicting Volume of Distribution in Humans: Performance of In Silico Methods for a Large Set of Structurally Diverse Clinical Compounds

Volume of distribution at steady state (V D,ss ) is one of the key pharmacokinetic parameters estimated during the drug discovery process. Despite considerable efforts to predict V D,ss , accuracy and choice of prediction methods remain a challenge, with evaluations constrained to a small set (<150) of compounds. To address these issues, a series of in silico methods for predicting human V D,ss directly from structure were evaluated using a large set of clinical compounds. Machine learning (ML) models were built to predict V D,ss directly and to predict input parameters required for mechanistic and empirical V D,ss predictions. In addition, log D, fraction unbound in plasma (fup), and blood-to-plasma partition ratio (BPR) were measured on 254 compounds to estimate the impact of measured data on predictive performance of mechanistic models. Furthermore, the impact of novel methodologies such as measuring partition (Kp) in adipocytes and myocytes (n = 189) on V D,ss predictions was also investigated. In predicting V D,ss directly from chemical structures, both mechanistic and empirical scaling using a combination of predicted rat and dog V D,ss demonstrated comparable performance (62%–71% within 3-fold). The direct ML model outperformed other in silico methods (75% within 3-fold, r 2 = 0.5, AAFE = 2.2) when built from a larger data set. Scaling to human from predicted V D,ss of either rat or dog yielded poor results (<47% within 3-fold). Measured fup and BPR improved performance of mechanistic V D,ss predictions significantly (81% within 3-fold, r 2 = 0.6, AAFE = 2.0). Adipocyte intracellular Kp showed good correlation to the V D,ss but was limited in estimating the compounds with low V D,ss .

59 BASIC BIOLOGICAL SCIENCES↗

A Comparative Study on Representativeness and Stochastic Efficacy of Miniature Tensile Specimen Testing

Here, in this article, a miniature dog bone tensile coupon design was tested against the existing ASTM standard specimen design. Specimens were prepared from commercially sourced austenitic stainless steel 304 alloy, and a defect-ridden additively manufactured 304L alloy was studied. By utilizing a tensile specimen design that is 1/230th volume of the smallest ASTM E8-04(2016), Standard Test Methods for Tension Testing of Metallic Materials, dog bone specimen, coupled to a digital image correlation (DIC) setup, case studies were performed to compare tensile property measurements and strain field evolution. Whereas yield strength measurements were observed to be similar, post-yield, the ultimate strength measurements and ductility measurements from the miniature specimens were observed to be higher than the ASTM specimen design. Although the strength measurements were comparable, the strain evolution was found to differ in the miniature specimens. Studies to assess effects of varying thickness and defect population were also pursued on the miniature tensile specimen. From the DIC strain field estimations, the peak local strain values at ultimate tensile strength were observed to be increasing with reducing specimen thickness. Testing of defect ridden stainless steel revealed the sensitivity to failure through strain localization and the influence of defect size was captured in the strength measurements.

36 MATERIALS SCIENCE↗