Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Radiation calculations and comparisons with data

In conjunction with the analysis of data from the Long Duration Exposure Facility (LDEF) ionizing radiation dosimetry, a calculation program was established to aid in data interpretation and to assess the accuracy of current radiation environments and effects models for future mission applications. Initial estimates of LDEF exposure to trapped, galactic, and atmospheric (albedo) radiation sources were made, and the radiation environment (primary and secondary particle spectra) and several radiation effects (induced radioactivity and dose) for varying amounts of LDEF shielding were calculated for a simplified LDEF mass model. Preliminary comparisons of the calculated results were made with the induced radioactivity measurements for several LDEF parts and with preliminary dose data from several experiments (P0004, P0006, and M0004). Predictions were compared with the radioactivity induced in the aluminum clamps holding the experiment trays and in the stainless steel trunnions to test a recently developed theory of trapped proton anisotropy.

Armstrong, T. W.↗

Survival of epiphytic bacteria from seed stored on the Long Duration Exposure Facility (LDEF)

This study was designed to determine the survival of microorganisms exposed to the relatively harsh conditions found in low Earth orbit (LEO). Seed of corn, sunflower, canteloupe, zucchini, bean, pea, and pumpkin cultivars were packaged in two 18 x 2.5 cm aluminum tubes; wall thickness for each tube was 1.33 mm. One seed tube was attacked to payload M0006, tray C-2; a second tube was stored at room temperature in a lab on Earth. Five lithium fluoride thermoluminescent dosimetry wafers (TLD-100 wafers) were placed in each aluminum tube. The total mean dosages for flight and ground-control TLD wafers were 210.0 and 0.9 rads, respectively. Seeds were washed for 2 hrs in a phosphate buffered saline solution. Bacteria were isolated by plating samples of the seed-washings onto dilute tryptic soy agar. Pure isolates of morphologically distinct bacteria were obtained by standard microbiological procedures. Bacteria were grouped according to colony-type and preliminary identification was completed using a fatty-acid analysis system. Bacillus spp. were the primary microoganisms that survived on seed during the experiment. Bacterial diversity and relative abundance were similar for the ground flight seed. Bacillus subtilus, B. pumilus, B. licheniformis, B. polymyxa, B. megaterium, and B. pabuli were isolated most frequently. Members of the genera Kurthia, Listeria, Micrococcus, and Arthrobacter were also isolated from flight and ground control seed. Results support the hypothesis that terrestrial microorganisms can survive long periods of time in the relatively harsh LEO environment.

Schuerger, Andrew C.↗

1990 IEEE Annual Conference on Nuclear and Space Radiation Effects, 27th, Reno, NV, July 16-20, 1990, Proceedings

Various papers on nuclear and space radiation effects are presented. The general topics addressed include: basic mechanisms of radiation effects, dosimetry and energy-dependent effects, hardness assurance and testing techniques, single-event upset and latchup, isolation technologies, device and integrated circuit effects and hardening, spacecraft charging and electromagnetic effects.

Fleetwood, Daniel M.↗

Ionizing radiation calculations and comparisons with LDEF data

In conjunction with the analysis of LDEF ionizing radiation dosimetry data, a calculational program is in progress to aid in data interpretation and to assess the accuracy of current radiation models for future mission applications. To estimate the ionizing radiation environment at the LDEF dosimeter locations, scoping calculations for a simplified (one dimensional) LDEF mass model were made of the primary and secondary radiations produced as a function of shielding thickness due to trapped proton, galactic proton, and atmospheric (neutron and proton cosmic ray albedo) exposures. Preliminary comparisons of predictions with LDEF induced radioactivity and dose measurements were made to test a recently developed model of trapped proton anisotropy.

Armstrong, T. W.↗

LDEF geometry/mass model for radiation analyses

A three-dimensional geometry/mass model of LDEF is under development for ionizing radiation analyses. This model, together with ray tracing algorithms, is being programmed for use both as a stand alone code in determining three-dimensional shielding distributions at dosimetry locations and as a geometry module that can be interfaced with radiation transport codes.

Colborn, B. L.↗

Status of LDEF ionizing radiation measurements and analysis

The LDEF-1 results from the particle astrophysics, radiation environments, and dosimetry measurements on LDEF-1 are summarized, including highlights from presentations at the 2nd symposium. Progress in using LDEF data to improve radiation environment models and calculation methods is reviewed. Radiation effects, or the lack thereof are discussed. Future plans of the LDEF Ionizing Radiation Special Investigation Group are presented.

Parnell, T. A.↗

Radiation model predictions and validation using LDEF data

Radiation dosimetry aboard LDEF, as well as post-flight measurements of the radioactivity induced in numerous LDEF spacecraft components, provide unique data for evaluating the accuracy of current models for predicting both the space radiation environments (trapped proton intensity, spectra, and directionality; cosmic ray fluence) and the radiation environments induced in spacecraft components (fluence, energy spectra, secondary particle, linear energy transfer, etc.). By determining the accuracy of such models using LDEF data, and with model updates where required, improved radiation environment predictions can be made for future missions, which in turn allows improved predictions for specific radiation effects for future spacecraft components (single event upsets of microelectronics, radiation damage to focal plane arrays, noise in sensitive instrumentation, etc.). Herein, the status and results from radiation model predictions and comparisons with LDEF data is given. The calculations are made using radiation transport codes coupled with a 3-D geometry/mass model of LDEF, together with current models of the space radiation environment.

Armstrong, T. W.↗

Future directions for LDEF ionizing radiation modeling and assessments

Data from the ionizing radiation dosimetry aboard LDEF provide a unique opportunity for assessing the accuracy of current space radiation models and in identifying needed improvements for future mission applications. Details are given of the LDEF data available for radiation model evaluations. The status is given of model comparisons with LDEF data, along with future directions of planned modeling efforts and data comparison assessments. The methodology is outlined which is related to modeling being used to help insure that the LDEF ionizing radiation results can be used to address ionizing radiation issues for future missions. In general, the LDEF radiation modeling has emphasized quick-look predictions using simplified methods to make comparisons with absorbed dose measurements and induced radioactivity measurements of emissions. Modeling and LDEF data comparisons related to linear energy transfer spectra are of importance for several reasons which are outlined. The planned modeling and LDEF data comparisons for LET spectra is discussed, including components of the LET spectra due to different environment sources, contribution from different production mechanisms, and spectra in plastic detectors vs silicon.

Armstrong, T. W.↗

Description, analysis and impact of major solar activity during recent U.S. Shuttle missions

Since STS-26, three large solar events have occurred during Shuttle missions: a geomagnetic storm during STS-29 and solar particle events (SPEs) during STS-28 and -34. The maximum dose to a crew attributed to an SPE was estimated to be 30 micro-Gy. Time-resolved dosimetry measurements of the SPE dose during STS-28 were made using the USAF Radiation Monitoring Equipment. Comparison of calculated and measured dose demonstrated a discrepancy, possibly a result of deficiencies in the geomagnetic cutoff model used. This experience demonstrates that dose from an SPE is strongly dependent on numerous factors such as orbit inclination, SPE start time, spectral parameters and geomagnetic field conditions; the exact combination of these factors is fortuitous. New sources of data and procedures are being investigated, including real-time tracking of auroral oval positions or determination of particle cutoff latitudes, for incorporation into operational Shuttle radiation support practices.

Golightly, M. J.↗

1991 IEEE Annual Conference on Nuclear and Space Radiation Effects, 28th, San Diego, CA, July 15-19, 1991, Proceedings

Various papers on nuclear science are presented. The general topics addressed are: basic mechanisms of radiation effects, dosimetry and energy-dependent effects, isolation technologies, device radiation response and hardening, microcircuit radiation response and hardening, single-event phenomena, hardness assurance and testing techniques, spacecraft charging, space environments and effects.

Millward, Douglas G.↗

Active dosimetric measurements on Shuttle flights

A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of LET and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 deg x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.

Badhwar, Gautam D.↗

Determination of atomic oxygen fluence using spectrophotometric analysis of infrared transparent witness coupons for long duration exposure tests

Atomic oxygen degradation is one of several major threats to the durability of spaceborne systems in low Earth orbit. Ground-based simulations are conducted to learn how to minimize the adverse effects of atomic oxygen exposure. Assessing the fluence of atomic oxygen in test chambers such as a plasma asher over long periods of time is necessary for accurate determination of atomic oxygen exposure. Currently, an atomic oxygen susceptible organic material such as Kapton is placed next to samples as a witness coupon and its mass loss is monitored and used to determine the effective atomic oxygen fluence. However, degradation of the Kapton witness coupons occurs so rapidly in plasma ashers that for any long term test many witness coupons must be used sequentially in order to keep track of the fluence. This necessitates opening vacuum to substitute fresh coupons. A passive dosimetry technique was sought to monitor atomic oxygen exposure over longer periods without the need to open the plasma asher to the atmosphere. This paper investigates the use of spectrophotometric analysis of durable IR transparent witness coupons to measure atomic oxygen exposure for longer duration testing. The method considered would be conductive to making in situ measurements of atomic oxygen fluence.

Podojil, Gregg M.↗

The emulsion chamber technology experiment

Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

Gregory, John C.↗

Future directions for LDEF ionizing radiation modeling and assessments

A calculational program utilizing data from radiation dosimetry measurements aboard the Long Duration Exposure Facility (LDEF) satellite to reduce the uncertainties in current models defining the ionizing radiation environment is in progress. Most of the effort to date has been on using LDEF radiation dose measurements to evaluate models defining the geomagnetically trapped radiation, which has provided results applicable to radiation design assessments being performed for Space Station Freedom. Plans for future data comparisons, model evaluations, and assessments using additional LDEF data sets (LET spectra, induced radioactivity, and particle spectra) are discussed.

Armstrong, T. W.↗

1992 IEEE Annual Conference on Nuclear and Space Radiation Effects, 29th, New Orleans, LA, July 13-17, 1992, Proceedings

The papers presented in this volume provide an overview of recent theoretical and experimental research related to nuclear and space radiation effects. Topics dicussed include single event phenomena, radiation effects in particle detectors and associated electronics for accelerators, spacecraft charging, and space environments and effects. The discussion also covers hardness assurance and testing techniques, electromagnetic effects, radiation effects in devices and integrated circuits, dosimetry and radiation facilities, isolation techniques, and basic mechanisms.

Van Vonno, Nick W.↗

Life Sciences and Space Research 25 (2) Radiation Biology: Topical Meeting of the COSPAR Interdisciplinary Scientific Commission F of the COSPAR 29th Plenary Meeting, Washington, DC, Aug. 28-Sep. 5, 1992

Papers presented on long-term exposure to ionizing radiation, obtained from the Long Duration Exposure Facility, included radiation monitoring, radiation effects, and dosimetry. Mechanisms of biological systems, especially cells, under ionizing radiation and relative biological effectiveness were compared. The role of HZE particles as agents of mutation were reported from plant, animal, and in vitro models. Data on known and predicted effects of cosmic rays and other solar radiation on biological systems included differences related to Linear Energy Transfer and heavy ion particles.

Horneck, G.↗

Results of time-resolved radiation exposure measurements made during U.S. shuttle missions with a tissue equivalent proportional counter

Time resolved exposure measurements inside the crew compartment have been made during recent shuttle missions with the USAF Radiation Monitoring Equipment-III (RME-III), a portable four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. The missions had orbital inclinations ranging from 28 degrees to 57 degrees, and altitudes from 200-600km. Dose equivalent rates ranged from 40-5300 micro Sv/dy. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicle. Measurements indicate that medium- and high- Linear Energy Transfer (LET) particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isa-dose rate contours have been developed from measurements made during the ST-28 mission. The drift rate of the South Atlantic Anomaly (SAA) is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and Galactic Cosmic Radiation (GCR) dose for the STS-28 mission were significantly lower than the measured values.

Golightly, M. J.↗

Status of LDEF radiation modeling

The current status of model prediction and comparison with LDEF radiation dosimetry measurements is summarized with emphasis on major results obtained in evaluating the uncertainties of present radiation environment model. The consistency of results and conclusions obtained from model comparison with different sets of LDEF radiation data (dose, activation, fluence, LET spectra) is discussed. Examples where LDEF radiation data and modeling results can be utilized to provide improved radiation assessments for planned LEO missions (e.g., Space Station) are given.

Watts, John W.↗