Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOUG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Changes in Global Function and Regional Ventilation and Perfusion on SPECT During the Course of Radiotherapy in Patients With Non-Small-Cell Lung Cancer

Purpose: This study aimed to (1) examine changes in dyspnea, global pulmonary function test (PFT) results, and functional activity on ventilation (V)/perfusion (Q) single-photon emission computerized tomography (SPECT) scans during the course of radiation (RT), and (2) factors associated with the changes in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: Fifty-six stage I to III NSCLC patients treated with definitive RT with or without chemotherapy were enrolled prospectively. Dyspnea was graded according to Common Terminology Criteria for Adverse Events version 3.0 prior to and weekly during RT. V/Q SPECT-computed tomography (CT) and PFTs were performed prior to and during RT at approximately 45 Gy. Functions of V and Q activities were assessed using a semiquantitative scoring of SPECT images. Results: Breathing improved significantly at the third week (mean dyspnea grade, 0.8 vs. 0.6; paired t-test p = 0.011) and worsened during the later course of RT (p > 0.05). Global PFT results did not change significantly, while regional lung function on V/Q SPECT improved significantly after {approx}45 Gy. The V defect score (DS) was 4.9 pre-RT versus 4.3 during RT (p = 0.01); Q DS was 4.3 pre-RT versus 4.0 during RT (p < 0.01). Improvements in V and Q functions were seen primarily in the ipsilateral lung (V DS, 1.9 pre-RT versus 1.4 during RT, p < 0.01; Q DS, 1.7 pre-RT versus 1.5 during RT, p < 0.01). Baseline primary tumor volume was significantly correlated with pre-RT V/Q DS (p < 0.01). Patients with central lung tumors had greater interval changes in V and Q than those with more peripheral tumors (p <0.05 for both V and Q DS). Conclusions: Regional ventilation and perfusion improved during RT at 45 Gy. This suggests that adaptive planning based on V/Q SPECT during RT may allow sparing of functionally recoverable lung tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Current Consensus Statement Recommendations for Accelerated Partial Breast Irradiation: A Pooled Analysis of William Beaumont Hospital and American Society of Breast Surgeon MammoSite Registry Trial Data

Purpose: To determine whether the American Society for Radiation Oncology (ASTRO) Consensus Statement (CS) recommendations for accelerated partial breast irradiation (APBI) are associated with significantly different outcomes in a pooled analysis from William Beaumont Hospital (WBH) and the American Society of Breast Surgeons (ASBrS) MammoSite® Registry Trial. Methods and Materials: APBI was used to treat 2127 cases of early-stage breast cancer (WBH, n=678; ASBrS, n=1449). Three forms of APBI were used at WBH (interstitial, n=221; balloon-based, n=255; or 3-dimensional conformal radiation therapy, n=206), whereas all Registry Trial patients received balloon-based brachytherapy. Patients were divided according to the ASTRO CS into suitable (n=661, 36.5%), cautionary (n=850, 46.9%), and unsuitable (n=302, 16.7%) categories. Tumor characteristics and clinical outcomes were analyzed according to CS group. Results: The median age was 65 years (range, 32-94 years), and the median tumor size was 10.0 mm (range, 0-45 mm). The median follow-up time was 60.6 months. The WBH cohort had more node-positive disease (6.9% vs 2.6%, P<.01) and cautionary patients (49.5% vs 41.8%, P=.06). The 5-year actuarial ipsilateral breast tumor recurrence (IBTR), regional nodal failure (RNF), and distant metastasis (DM) for the whole cohort were 2.8%, 0.6%, 1.6%. The rate of IBTR was not statistically higher between suitable (2.5%), cautionary (3.3%), or unsuitable (4.6%) patients (P=.20). The nonsignificant increase in IBTR for the cautionary and unsuitable categories was due to increased elsewhere failures and new primaries (P=.04), not tumor bed recurrence (P=.93). Conclusions: Excellent outcomes after breast-conserving surgery and APBI were seen in our pooled analysis. The current ASTRO CS guidelines did not adequately differentiate patients at an increased risk of IBTR or tumor bed failure in this large patient cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collision-Induced Dissociation (DCID) in a Quadrupole Ion Trap Using a Two-Frequency Excitation Waveform: II. Effects of Frequency Spacing and Scan Rate

Dynamic CID of selected precursor ions is achieved by the application of a two-frequency excitation waveform to the end-cap electrodes during the mass instability scan of a quadrupole ion trap mass spectrometer (QIT-MS). The time period normally allotted for resonance excitation and collisional cooling of the trapped ion are excluded and fragmentation instead takes place simultaneously with the mass acquisition scan. This new method permits a shorter scanning time when compared to conventional on-resonance CID. When the excitation waveform consists of two closely-spaced frequencies, the relative phase-relationship of the two frequencies plays a critical role in the fragmentation dynamics. However, at wider frequency spacings (>8 kHz) these phase effects are diminished, while maintaining the efficacy of closely-spaced excitation frequencies. The fragmentation efficiencies and energetics of n-butylbenzene and tetraalanine are studied under different experimental conditions and the results are compared at various scan rate parameters between 0.1 and 1.0 ms/Th. Although faster scan rates reduce the analysis time, the maximum observed fragmentation efficiencies rarely exceed 30%, compared to values in excess of 50% achieved at slower scan rates. The internal energies calculated from the simulations of n-butylbenzene at fast scan rates are ~4 eV for most experimental conditions, while at slow scan rates internal energies above 5.5 eV are observed for a wide range of conditions. Extensive ITSIM simulations support the observation that slowing the scan rate has a similar effect on fragmentation as widening the frequency spacing between the two excitation frequencies. Both approaches generally enhance CID efficiencies and make fragmentation less dependent upon the relative phase angle between the excitation waveform and the ion motion. This could be useful for optimizing the CID efficiencies for a wide range of precursor ion mass-to-charge ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling

Here, diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

54 ENVIRONMENTAL SCIENCES↗

Correlation between microstructure and residual stress formation in friction stir welded armor steels characterized by neutron diffraction

Friction stir welding (FSW) is a solid-state joining process that minimizes the heat-affected zone (HAZ) compared with fusion-based arc welding, making it well suited for joining martensitic armor steels where hardness and ballistic resistance are critical. This study investigates residual stress formation in three defect-free FSW butt-joint configurations relevant to armored-vehicle fabrication: similar rolled homogeneous armor (RHA–RHA, Case 1), similar high-hardness armor (HHA–HHA, Case 2), and dissimilar HHA–RHA (Case 3) joints produced under temperature-controlled conditions (770 °C). Neutron diffraction was employed to quantify the magnitude and spatial distribution of residual stresses in the longitudinal, transverse, and normal directions and to correlate them with weld microstructure and hardness. Tensile residual stresses were concentrated in the softened HAZ, reaching approximately 300 MPa for Case 2 and 400 MPa for Case 1 (≈50–70 % of the base-metal yield strength; ∼581 MPa for RHA and ∼566 MPa for HHA), while compressive residual stresses dominated the stir zone. The spatial extent of tensile stresses scaled with the width of the softened HAZ, which was largest in the dissimilar HHA–RHA joint and smallest in the HHA–HHA joint. Full-width-at-half-maximum (FWHM) analysis revealed low microstrain in overtempered HAZ regions and high microstrain in the stir zone associated with severe plastic deformation and fresh martensite formation. This work demonstrates that residual stress evolution in FSW of martensitic armor steels is governed not primarily by peak temperature or thermal contraction, as inferred from fusion-welding analogies, but by the competition between transformation-induced volumetric expansion and tempering-induced stress relaxation. The relative dominance of these mechanisms is shown to depend on alloy hardenability and local thermal history, leading to more extensive HAZ softening and broader tensile stress regions in the lower-hardenability RHA steel. These findings establish a transferable mechanistic framework for optimizing solid-state joining strategies in high-strength steels and other transformation-hardening alloys beyond armor applications.

Friction stir welding↗

Practical Aspects for Characterizing Air Oxidation of Graphite

The efforts for designing of a meaningful and acceptable standard test method for characterization of kinetic parameters of air oxidation of graphite helped identify several practical issues that must be considered for the development of such a test. Using standard size (and shape) specimens, large enough in size to accommodate the inherent local microstructure differences between graphite samples, resulted in non-uniform oxidation profiles and preferential binder oxidation; this was not expected based on the linearity of Arrhenius plots and the (large) values of activation energy. It was found that the transition between the regimes 1 and 2 of graphite oxidation occurs gradually, depending both on the oxidation temperature and rate of oxygen supply. Nevertheless, measuring oxidation rates obtained on standard size samples provides a basis for a meaningful comparison among materials, which may serve as much needed information for predictive models.

36 MATERIALS SCIENCE↗

Selection and properties of alternative forming fluids for TRISO fuel kernel production

Current Very High Temperature Reactor (VHTR) designs incorporate TRi-structural ISOtropic (TRISO) fuel, which consists of a spherical fissile fuel kernel surrounded by layers of pyrolytic carbon and silicon carbide. An internal sol-gel process forms the fuel kernel using wet chemistry to produce uranium oxyhydroxide gel spheres by dropping a cold precursor solution into a hot column of trichloroethylene (TCE). Over time, gelation byproducts inhibit complete gelation, and the TCE must be purified or discarded. The resulting TCE waste stream contains both radioactive and hazardous materials and is thus considered a mixed hazardous waste. Changing the forming fluid to a non-hazardous alternative could greatly improve the economics of TRISO fuel kernel production. Selection criteria for a replacement forming fluid narrowed a list of ~10,800 chemicals to yield ten potential replacement forming fluids: 1-bromododecane, 1- bromotetradecane, 1-bromoundecane, 1-chlorooctadecane, 1-chlorotetradecane, 1-iododecane, 1-iodododecane, 1-iodohexadecane, 1-iodooctadecane, and squalane. The density, viscosity, and surface tension for each potential replacement forming fluid were measured as a function of temperature between 25 °C and 80 °C. Calculated settling velocities and heat transfer rates give an overall column height approximation. 1-bromotetradecane, 1-chlorooctadecane, and 1-iodododecane show the greatest promise as replacements, and future tests will verify their ability to form satisfactory fuel kernels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detailed measurements of local thickness changes for U-7Mo dispersion fuel plates with Al-3.5Si matrix after irradiation at different powers in the RERTR-9B experiment

The Materials Management and Minimization program is developing fuel designs to replace highly enriched fuel with fuels of low enrichment. Swelling is an important irradiation behavior that needs to be well understood. Data from high resolution thickness measurements performed on U-7Mo dispersion fuel plates with Al-Si alloy matrices that were irradiated at high power is sparse. This paper reports the results of detailed thickness measurements performed on two dispersion fuel plates that were irradiated at relatively high power to high fission densities in the Advanced Test Reactor in the same RERTR-9B experiment. Both plates were irradiated to similar fission densities, but one was irradiated at a higher power than the other. The goal of this work is to identify any differences in the swelling behavior when fuel plates are irradiated at different powers to the same fission densities. Based on the results of detailed thickness measurments, more swelling occurs when a U-7Mo dispersion fuel with Al-3.5Si matrix is irradiated to a high fission density at high power compared to one irradiated at a lower power to high fission density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modern nanostructured ferritic alloys: A compelling and viable choice for sodium fast reactor fuel cladding applications

Sodium fast reactor cores present a truly challenging environment for the fuel cladding and core structural materials that limit achievable fuel burnup in these systems. Modern nanostructured ferritic alloys have the potential to deliver the desired high performance characteristics where historic austenitic and ferritic/martensitic alloys fall short. Herein, a new nanostructured ferritic alloy, OFRAC ( O ak Ridge F ast R eactor A dvanced Fuel C ladding), is developed and demonstrated in cladding geometry with a length > 1 m. The alloy composition and microstructure are tailored to deliver dramatically improved strength and creep resistance. At 600 °C the ultimate tensile strength is ~600 MPa and the stress to induce a steady state strain rate of 10 -6 s -1 is 500 MPa vs. 200 MPa for traditional ferritic/martensitic alloys. A very high defect sink density was engineered in these alloys that is expected to further enhance the traditional good swelling and irradiation creep resistance of ferritic/martensitic steels. These significant improvements along with the demonstrated viability for seamless cladding production indicate that this alloy is a compelling and viable choice for sodium fast reactor fuel cladding applications.

36 MATERIALS SCIENCE↗

Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors

There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5 Gy (0.7 to 9.6 Gy) at FB, 1.2 Gy (0.6 to 3.8 Gy, p < 0.001) at 75% inspiration, 1.1 Gy (0.6 to 3.1 Gy, p = 0.004) at 90% inspiration, 1.0 Gy (0.6 to 3.0 Gy) at 100% inspiration or DIBH, and 1.0 Gy (0.6 to 2.8 Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9 Gy (2.4 to 46.4 Gy), 8.6 Gy (2.0 to 43.8 Gy, p < 0.001), 7.2 Gy (1.9 to 40.1 Gy, p = 0.035), 6.5 Gy (1.8 to 34.7 Gy), and 5.3 Gy (1.5 to 31.5 Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of porous materials using combined small-angle X-ray and neutron scattering techniques

A combination of ultra small angle X-ray scattering (USAXS) and ultra small angle neutron scattering (USANS) is used to characterize porous materials. The analysis methods yield quantitative information, including the mean skeletal chord length, mean pore chord length, skeletal density, and composition. A mixed cellulose ester (MCE) membrane with a manufacturer-labeled pore size of 0.1 {mu}m was used as a model to elucidate the specifics of the method. Four approaches describing four specific scenarios (different known parameters and form of the scattering data) are compared. Pore chords determined using all four approaches are in good agreement with the scanning electron microscopy estimates but are larger than the manufacturer's nominal pore size. Our approach also gives the average chord of the skeletal solid (struts) of the membrane, which is also consistent for all four approaches. Combined data from USAXS and USANS gives the skeletal density and the strut composition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Room temperature sodium diffusion in sodium iron phosphate investigated with neutron scattering

Sodium iron phosphate, Na x FePO 4 , is currently one of the most promising cathode materials for sodium ion batteries. Here we employ a systematic approach using three neutron scattering techniques to investigate temperature dependent properties with a focus on the charge transfer processes. Two distinct Na + diffusive motions are observed with quasielastic neutron scattering, including room temperature motion. These processes correspond to rapid double jumps through extrinsic vacancy sites of ∼6 Å along with the more fundamental nearest neighbor jumps of 3.1 Å. Experimental observations of room temperature ionic diffusion are highly desirable, as the diffusion pathways are naturally well suited for efficient transport. Inelastic neutron scattering was used to probe the vibrational density of states that assist in the ionic and electronic (polaronic) transport processes, which are further supported with density functional theory. Neutron diffraction examines the disordering of the sodium sublattice upon transition to the solid-solution phase, which is believed to enhance the overall kinetics during sodium insertion/extraction. Finally, 57 Fe Mössbauer spectroscopy measurements probes polaron hopping and the local structural evolution that modifies the electron density surrounding the redox active iron sites. This study sheds light on the temperature induced atomic scale dynamics that occur in olivine Na x FePO 4 .

Novak, Eric [Swarthmore College, Swarthmore, PA (U↗

Neuroanatomical and cognitive correlates of visual hallucinations in Parkinson’s disease and dementia with Lewy bodies: Voxel-based morphometry and neuropsychological meta-analysis

Visual hallucinations (VH) are common in Parkinson's disease and dementia with Lewy bodies, two forms of Lewy body disease (LBD), but the neural substrates and mechanisms involved are still unclear. We conducted meta-analyses of voxel-based morphometry (VBM) and neuropsychological studies investigating the neuroanatomical and cognitive correlates of VH in LBD. For VBM (12 studies), we used Seed-based d Mapping with Permutation of Subject Images (SDM-PSI), including statistical parametric maps for 50% of the studies. For neuropsychology (35 studies), we used MetaNSUE to consider non-statistically significant unreported effects. VH were associated with smaller grey matter volume in occipital, frontal, occipitotemporal, and parietal areas (peak Hedges' g -0.34 to -0.49). In patients with Parkinson's disease without dementia, VH were associated with lower verbal immediate memory performance (Hedges' g -0.52). Both results survived correction for multiple comparisons. Here, abnormalities in these brain regions might reflect dysfunctions in brain networks sustaining visuoperceptive, attention, and executive abilities, with the latter also being at the basis of poor immediate memory performance.

60 APPLIED LIFE SCIENCES↗

High gradient tests of metallic mm-wave accelerating structures

This study explores the physics of vacuum rf breakdowns in high gradient mm-wave accelerating structures. We performed a series of experiments with 100 GHz and 200 GHz metallic accelerating structures, at the Facility for Advanced Accelerator Experimental Tests (FACET) at the SLAC National Accelerator Laboratory. This paper presents the experimental results of rf tests of 100 GHz travelling-wave accelerating structures, made of hard copper-silver alloy. The results are compared with pure hard copper structures. The rf fields were excited by the FACET ultra-relativistic electron beam. The accelerating structures have open geometries, 10 cm long, composed of two halves separated by a variable gap. The rf frequency of the fundamental accelerating mode depends on the gap size and can be changed from 90 GHz to 140 GHz. The measured frequency and pulse length are consistent with our simulations. When the beam travels off-axis, a deflecting field is induced in addition to the decelerating longitudinal field. We measured the deflecting forces by observing the displacement of the electron bunch and used this measurement to verify the expected accelerating gradient. We present the first quantitative measurement of rf breakdown rates in 100 GHz copper-silver accelerating structure, which was 10 –3 per pulse, with peak electric field of 0.42 GV/m, an accelerating gradient of 127 MV/m, at a pulse length of 2.3 ns. The goal of our studies is to understand the physics of gradient limitations in order to increase the energy reach of future accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of polymeric films subjected to lithium ion beam irradiation

Two different polymeric materials that are candidate materials for use as binders for mixed uranium–plutonium oxide nuclear fuel pellets were subjected to Li ion beam irradiation, in order to simulate intense alpha irradiation. The materials (a polyethylene glycol 8000 and a microcrystalline wax) were then analyzed using a combination of mass spectrometry (MS) approaches and X-ray photoelectron spectroscopy (XPS). Samples of the irradiated PEG materials were dissolved in H2O and then analyzed using electrospray ionization-MS, which showed the formation of a series of small oligomers in addition to intact large PEG oligomers. The small oligomers were likely formed by radiation-induced homolytic scissions of the C–O and C–C bonds, which furnish radical intermediates that react by radical recombination with Hradical dot and OHradical dot. Surface analysis using SIMS revealed a heterogeneous surface that contained not only PEG-derived polymers, but also hydrocarbon-based entities that are likely surface contaminants. XPS of the irradiated PEG samples indicated the emergence of different carbon species, with peak shifts suggesting the presence of sp2 carbon atoms. Analysis of the paraffinic film using XPS showed the emergence of oxygen on the surface of the sample, and also a broadening and shifting of the C1s peak, demonstrating a change in the chemistry on the surface. The paraffinic film did not dissolve in either H2O or a H2O–methanol solution, and hence the bulk of the material could not be analyzed using electrospray. However a series of oligomers was leached from the bulk material that produced ion series in the ESI-MS analyses that were identified octylphenyl ethoxylate oligomers. Upon Li ion bombardment, these shifted to a lower average molecular weight, but more importantly showed the emergence of three new ion series that are being formed as a result of radiation damage. Surface analysis of the paraffinic polymers using SIMS produced spectra that were wholly dominated by hydrocarbon ion series, and no difference was observed between unirradiated and irradiated samples. The studies demonstrate that for the PEG-based polymers, direct evidence for radiolytic scission can be observed using ESI-MS, and suggests that both radiolytic pathways and efficiencies as a function of dose should be measurable by calibrating instrument response to the small oligomeric degradation products.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) nanocomposites with optimal mechanical properties

With the ultimate goal to design renewable polymer nanocomposites with optimal mechanical properties, this study reports an investigation of structure-property relationships for a model system - silica/poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHx) nanocomposites. Two molecular weights of PHBHx (M{sub w} = 903,000 g/mol and M{sub w} = 633,000 g/mol) and two types of silica nanoparticles (nominally spheres and fibers according to the manufacturer) were used to prepare the nanocomposites. Small-angle X-ray scattering shows that the sphere and fiber nanoparticles had similar surface areas and primary particle size, but differed in degree of aggregation of the primary particles. The thermal stability of the PHBHx matrix was slightly improved by the addition of nanofillers. Simultaneous improvement of both stiffness and toughness was observed at 1-wt% loading for the higher molecular weight matrix. The more highly aggregated SiO{sub 2} fibers had a greater toughening effect than the SiO{sub 2} spheres. Compared to the unfilled polymer matrix, a 30% increase in Young's modulus and 34% increase in toughness were obtained for the 1-wt% SiO{sub 2} fiber/PHBHx072 nanocomposite. The addition of SiO{sub 2} spheres to PHBHx072 resulted in the same increase in Young's modulus (30%) but a smaller increase (11%) in toughness. The dramatic increases in modulus for PHBHx072 cannot be explained on the basis of two-component micromechanical models. Apparently the filler alters the character of the semicrystalline matrix. When the loading was 3 wt% and above, Young's modulus continued to increase, but the strain at break and toughness decreased. The ultimate strength did not change compared with the unfilled polymer. In order to understand the mechanical properties observed, the thermal behavior, spherulitic morphology and the deformation mechanisms of the nanocomposites and the dispersion state of the nanofillers were studied. We found that a high molecular weight of the polymer matrix, weak interfacial adhesion and a good dispersion of the nanofillers are necessary to improve toughness and stiffness simultaneously.

36 MATERIALS SCIENCE↗