Search NASA⌕ Search

SEARCH · Search NASA

Results for “Degrader”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Statistical analysis and degradation pathway modeling of photovoltaic minimodules with varied packaging strategies

Degradation pathway models constructed using network structural equation modeling (netSEM) are used to study degradation modes and pathways active in photovoltaic (PV) system variants in exposure conditions of high humidity and temperature. This data-driven modeling technique enables the exploration of simultaneous pairwise and multiple regression relationships between variables in which several degradation modes are active in specific variants and exposure conditions. Durable and degrading variants are identified from the netSEM degradation mechanisms and pathways, along with potential ways to mitigate these pathways. A combination of domain knowledge and netSEM modeling shows that corrosion is the primary cause of the power loss in these glass/backsheet PV minimodules. We show successful implementation of netSEM to elucidate the relationships between variables in PV systems and predict a specific service lifetime. The results from pairwise relationships and multiple regression show consistency. This work presents a greater opportunity to be expanded to other materials systems.

electrical measurements↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells

Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm ) of aged MEAs based on synchrotron X-ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non-uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non-uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.

36 MATERIALS SCIENCE↗

UV-Induced Degradation and Associated Metastability in TOPCon Photovoltaic Modules: Understanding Kinetics and Cell Variance

Tunnel oxide passivated contact (TOPCon) silicon photovoltaic (PV) modules are dominating the PV market, but they may be susceptible to degradation under ultraviolet (UV)-containing light. Quantifying the impacts of UV-induced degradation (UVID) is complicated by an associated metastability causing further degradation under dark storage and rapid recovery under sunlight. Here, we study modules that have -2.3% to -3.2% nonrecoverable UVID loss after 60 kWh/m2 dose of 340 nm light and additional recoverable loss under dark storage. We use in situ electroluminescence (EL) imaging to characterize the post-UVID metastability at the module level. The cell-by-cell dark degradation and recovery kinetics span a wide range from +6% to -70% changes in EL intensity after 520 h of dark storage, which returns to +- 4% of the initial post-UVID EL intensity after illumination. The kinetics follow double exponential rates with dark storage degradation time constants of 345 and 45 h, and UV light recovery time constants of 5 min and 36 s. We propose that this is consistent with prior reports of kinetics for light-soaking metastability in Al2O3 passivation. Finally, we further show that cells having high UVID also have injection-dependent effective carrier lifetimes and significant intra-cell variance, suggesting possible origins of processing inconsistency.

14 SOLAR ENERGY↗

Degradation mechanism of lead-vanado-iodoapatite in NaCl solution

Degradation mechanism of lead-vanado-iodoapatite (IAPT) in NaCl solution at 90 °C was investigated through systematic characterization of surface morphology, microstructure and microchemistry evolution of the alteration layer. Nano-scale characterization indicated that IAPT crystals degraded from grain boundaries toward inner grains, forming ultrafine Cl-bearing crystallites. A coupled interface dissolution-reprecipitation replacement mechanism and the ion exchange between Cl - and I - across the degradation zone may together play roles in determining the nano-scale degradation behavior of IAPT. This work highlights the degradation through multiple reactions and elemental transport across the liquid-solid and solid-solid interfaces at length scales from sub-millimeter to nanoscale.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Forecasting battery capacity and power degradation with multi-task learning

Lithium-ion batteries degrade due to usage and exposure to environmental conditions, which affects their capability to store energy and supply power. Accurately predicting the capacity and power fade of lithium-ion battery cells is challenging due to intrinsic manufacturing variances and coupled nonlinear ageing mechanisms. In this paper, we propose a data-driven prognostics framework to predict both capacity and power fade simultaneously with multi-task learning. The model is able to predict the degradation trajectory of both capacity and internal resistance together with knee-points and end-of-life points accurately at early-life stage. The validation shows an average percentage error of 2.37% and 1.24% for the prediction of capacity fade and resistance rise, respectively. The model's ability to accurately predict the degradation, facing capacity and resistance estimation errors, further demonstrates the model's robustness and generalizability. Compared with single-task learning models for forecasting capacity and power degradation, the model shows a significant prediction accuracy improvement and computational cost reduction. This work presents the highlights of multi-task learning in the degradation prognostics for lithium-ion batteries.

25 ENERGY STORAGE↗

A control oriented comprehensive degradation model for battery energy storage system life prediction

In order to ensure that stationary battery energy storage systems (BESSs) provide reliable energy buffering, both for power quality and economic purposes, the degradation must be considered. Cell degradation involves various side reactions and is highly dependent on its operating conditions. To accurately track cell degradation and predict its impact on battery behavior, a comprehensive physics-based degradation model based on an electrolyte phase-enhanced single particle (SP) model is developed. Key degradation physics, namely solid electrolyte interphase (SEI) layer formation and growth, Li plating on the graphite anode, and Mn dissolution on cathode of nickel-cobalt-manganese oxide (NMC622) are considered. The model is validated against experimental capacity data. The results reveal that the deposition rate of both SEI layer and Li metal increase as the charge voltage increases. At the cathode side, the solvent oxidation rate determines the Mn dissolution rate. As a result, the volume fraction of NMC622 in the cathode continually decreases at a gradually increasing rate.

25 ENERGY STORAGE↗

Degradation and fate of 2,4-dinitroanisole (DNAN) and its intermediates treated with Mg/Cu bimetal: Surface examination with XAS, DFT, and LDI-MS

In this article, a novel Mg-based bimetal reagent (Mg/Cu) was used as an enhanced reductive system to degrade insensitive munition 2,4-dinitroanisole (DNAN), a contaminant found in energetic-laden waste. Degradation of DNAN was significantly impacted by dissolved oxygen and studied in anoxic and oxic bimetal systems (i.e., purging with N 2 , air, or O 2 gas). Degradation occurred through sequential nitroreduction: first one nitro group was reduced (ortho or para) to form short-lived intermediates 2-amino-4-nitroanisole or 4-amino-2-nitroanisole (2-ANAN or 4-ANAN), and then subsequent reduction of the other nitro group formed 2,4-diaminoanisole (DAAN). The nitro-amino intermediates demonstrated regioselective reduction in the ortho position to 2-ANAN; Regioselectivity was also impacted by the anoxic/oxic environment. Under O 2 -purging DNAN degradation rate was slightly enhanced, but most notably O 2 significantly accelerated DAAN generation. DAAN also further degraded only in the oxygenated Mg/Cu system. Adsorption of DNAN byproducts to the reagent occurred regardless of anoxic/oxic condition, resulting in a partition of carbon mass between the adsorbed phase (27%-35%) and dissolved phase (59%-72%). Additional surface techniques were applied to investigate contaminant interaction with Cu. Density functional theory (DFT) calculations identified preferential adsorption structures for DNAN on Cu with binding through two O atoms of one or both nitro groups. X-ray absorption spectroscopy (XAS) measurements determined the oxidation state of catalytic metal Cu and formation of a Cu-O-N bond during treatment. Laser desorption ionization mass spectrometry (LDI-MS) measurements also identified intermediate 2-ANAN adsorbed to the bimetal surface.

54 ENVIRONMENTAL SCIENCES↗

Degradation and recovery of solid oxide fuel cell performance by control of cathode surface acidity: Case study – Impact of Cr followed by Ca infiltration

Solid oxide fuel cells (SOFC) have attracted attention as clean and efficient energy conversion devices with low emissions. However, several degradation mechanisms limit the electrochemical performance of current SOFCs, with cathode degradation due to Cr-poisoning from metal interconnects particularly problematic. The acidity/basicity of binary additives has been found to be a sensitive descriptor of the oxygen exchange kinetics, indicating that acidic Cr-species/basic Ca-species can be expected to deactivate/activate the cathode surface, respectively. Inspired by recent advances, the feasibility of relative acidity as a tool for reviving degraded SOFCs is demonstrated by neutralizing Cr-poisoned SOFCs by subsequent serial infiltration of Ca-species. Furthermore, a model mixed ionic and electronic conducting oxide, Pr 0.1 Ce 0.9 O 2-δ (PCO), is selected as the cathode material. Area-specific resistances (ASR) of symmetric cells obtained by electrochemical impedance spectroscopy show that Cr-infiltration results in a seven-fold increase in ASR, while subsequent infiltration of Ca-species leads to complete recovery. Performance degradation and recovery are attributed to depressed/enhanced redox properties at the PCO surface, as supported by XPS analysis. Experiments using anode-supported fuel cells show a reduction in peak power density by 26% upon Cr-infiltration, reversed following Ca-infiltration, after which no degradation is observed during subsequent operation for 100 h.

(Pr,Ce)O2-δ↗

Photovoltaic Cleaning Frequency Optimization Under Different Degradation Rate Patterns

Dust accumulation significantly affects the performance of photovoltaic modules and its impact can be mitigated by various cleaning methods. Optimizing the cleaning frequency is essential to minimize the soiling losses and, at the same time, the costs. However, the effectiveness of cleaning lowers with time because of the reduced energy yield due to degradation. Additionally, economic factors such as the escalation in electricity price and inflation can compound or counterbalance the effect of degradation on the soiling mitigation profits. The present study analyzes the impact of degradation, escalation in electricity price and inflation on the revenues and costs of cleanings and proposes a methodology to maximize the profits of soiling mitigation of any system. Here, the energy performance and soiling losses of a 1 MW system installed in southern Spain were analyzed and integrated with theoretical linear and nonlinear degradation rate patterns. The Levelized Cost of Energy and Net Present Value were used as criteria to identify the optimum cleaning strategies. The results showed that the two metrics convey distinct cleaning recommendations, as they are influenced by different factors. For the given site, despite the degradation effects, the optimum cleaning frequency is found to increase with time of operation.

14 SOLAR ENERGY↗

Forest structure and solar-induced fluorescence across intact and degraded forests in the Amazon

Tropical forest degradation (e.g., anthropogenic disturbances such as selective logging and fires) alters forest structure and function and influences the forest's carbon sink. In this study, we explored structure-function relationships across a variety of degradation levels in the southern Brazilian Amazon by 1) investigating how forest structural properties vary as a function of degradation history using airborne lidar data; 2) assessing the effects of degradation on solar-induced chlorophyll fluorescence (SIF) seasonality using TROPOMI data; and 3) quantifying the contribution of structural variables to SIF using multiple regression models with stepwise selection of lidar metrics. Forest degradation history was obtained through Landsat time-series classification. We found that fire, logging, and time since disturbance were major determinants of forest structure, and that forests affected by fires experienced larger variability in leaf area index (LAI), canopy height and vertical structure relative to logged and intact forests. Moreover, only recently burned forests showed significantly depressed SIF during the dry season compared to intact forests. Canopy height and the vertical distribution of foliage were the best predictors of SIF. Unexpectedly, we found that wet-season SIF was higher in active regenerating forests (~ 4 years after fires or logging) compared with intact forests, despite lower LAI. Furthermore, our findings help to elucidate the mechanisms of carbon accumulation in anthropogenically disturbed tropical forests and indicate that they can capture large amounts of carbon while recovering.

54 ENVIRONMENTAL SCIENCES↗

An efficient Chlorella sp.-Cupriavidus necator microcosm for phenol degradation and its cooperation mechanism.

In this work, a Chlorella sp.-Cupriavidus necator (C. necator) microcosm was artificially established for phenol degradation. Additionally, the cooperation relationship between Chlorella sp. and C. necator was initially demonstrated, and then the effects of Chlorella sp./C. necator inoculation ratio, light intensity, temperature and pH on the performance of this microcosm were systematically evaluated and optimized. The optimal conditions for phenol degradation were as follows: a Chlorella sp./C. necator inoculation ratio of 1:1, a light intensity of 110 μmol m -2 s -1 , a temperature in the range of 25-32 °C and a pH in the range of 5.5-7.5. Under optimal conditions, this microcosm could degrade phenol with a maximum concentration of 1200 mg L -1 within 60 h. It was found that only when the phenol concentration was reduced to the tolerance concentration of microalgae, that is, the last stage of phenol degradation, the cooperation effect could be generated, indicating that the tolerance of microalgae to phenol may be more important than its degradation performance. Comparative transcriptomic analysis was conducted to discuss the cooperation mechanism of this microcosm subject to high phenol concentrations. The up-regulation of genes involved in photosynthesis and carbon fixation of Chlorella sp. demonstrated the CO 2 and O 2 exchange between Chlorella sp. and C. necator and their cooperation relationship. This study suggests that this microcosm has great potential for the bioremediation of phenol contaminants.

59 BASIC BIOLOGICAL SCIENCES↗

Potential induced degradation in c-Si glass-glass modules after extended damp heat stress

Traditional Glass-Backsheet (GB) photovoltaic (PV) modules have been the industry standard for a long time, but the Glass-Glass (GG) modules are quickly rising in popularity. PV modules installed in hot-humid climates with high string voltages can undergo potential induced degradation (PID). So far, to the best of our knowledge, only fresh modules with strong interfacial adhesion have been investigated for PID. However, in reality, the PV modules have weak interfacial adhesion after a few years of field exposure. Therefore, it is essential to evaluate PV modules with weakened interfaces. In this study, we investigated the PID susceptibility of PV modules with weakened interfaces after subjecting them to 2000 hours of damp heat (DH2000) at 85°C/85% relative humidity (RH) in an accelerated environmental chamber. Fresh GG modules were also stressed for PID to compare with PID degradation of DH-stressed modules. Pre- and post-characterization tests were done before, between, and after each stress method to determine the changes in electrical performance, cell metallization properties, and hotspot properties. It is observed that fresh GG modules showed little/no degradation (less than 1%) in maximum power (Pmax), whereas the GG modules that underwent sequential DH and PID degraded by 11% to 12%. Potential mechanisms for these degradations are also presented. Furthermore, the results presented in this study are critical for the industry, considering that the bifacial modules with GG construction will be dominant in the next 10 years.

14 SOLAR ENERGY↗

Understanding interfacial chemistry of positive bias high-voltage degradation in photovoltaic modules

Photovoltaic module degradation from a high system voltage is a prevalent degradation mode in the field, where the enabling degradation mechanisms are inherently dependent on the voltage bias polarity of the installed system. In this study, the effects of positive bias on module performance are confirmed and the underlying chemical degradation processes are more thoroughly investigated to reveal different degradation pathways from those previously reported in negative bias studies. When cells are under +1000 V stress, crystalline silicon mini-modules with poly(ethylene-co-vinyl acetate) (EVA) encapsulant demonstrated a significant photocurrent loss due to EVA discoloration and delamination from increased chemical reactivity at the front-side EVA/cell metallization interface. Brown discoloration of the EVA encapsulant near the cell gridlines is linked to an electrochemical reaction at the Ag gridlines under hot and humid conditions (85 °C, 85% relative humidity). Chemical compositional analysis using X-ray photoelectron spectroscopy (XPS) confirmed that the discoloration is attributed to the formation of silver sulfide (Ag 2 S) and/or silver oxide (Ag 2 O) species at the EVA/Ag gridline interface. The subsequent migration of Ag ions from the cell gridlines into the bulk of the EVA was evident from XPS depth profiling and optical microscopy. However, the Ag signal was not detected at the EVA/glass interface, inferring limited ionic transport through the nominally 0.45 mm thick encapsulant. For the samples studied herein, the sulfur is believed by the process of elimination to come from the ambient air, diffusing into the module through the permeable polymer backsheet.

14 SOLAR ENERGY↗

Degradation of Adsorbed Bisphenol A by Soluble Mn(III)

Bisphenol A (BPA), a high production volume chemical and potential endocrine disruptor, is found to be associated with sediments and soils due to its hydrophobicity (log K OW of 3.42). Here, we used superfine powdered activated carbon (SPAC) with a particle size of 1.38 ± 0.03 μm as a BPA sorbent and assessed degradation of BPA by oxidized manganese (Mn) species. SPAC strongly sorbed BPA, and desorption required organic solvents. No degradation of adsorbed BPA (278.7 ± 0.6 mg BPA g –1 SPAC) was observed with synthetic, solid α-MnO 2 with a particle size of 15.41 ± 1.35 μm; however, 89% mass reduction occurred following the addition of 0.5 mM soluble Mn(III). Small-angle neutron scattering data suggested that both adsorption and degradation of BPA occurred in SPAC pores. The findings demonstrate that Mn(III) mediates oxidative transformation of dissolved and adsorbed BPA, the latter observation challenging the paradigm that contaminant desorption and diffusion out of pore structures are required steps for degradation. Soluble Mn(III) is abundant near oxic-anoxic interfaces, and the observation that adsorbed BPA is susceptible to degradation has implications for predicting, and possibly managing, the fate and longevity of BPA in environmental systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Codeposition on Methylammonium Iodide Degradation during Vapor Transport Deposition

Vapor transport deposition (VTD) is one manufacturing-compatible technique for large-scale deposition of perovskite films. However, to date, little understanding has been given to degradation products formed by perovskites grown under vacuum. Here, we use methylammonium iodide (MAI) as an example organic precursor to identify degradation patterns through both the sublimation process and transport through a zone with temperatures much higher than MAI can thermodynamically survive. We show that degradation due to sublimation effects MAI powders and subsequent integration into methylammonium lead iodide (MAPbI3) films differently than degradation solely due to material transport through a very high-temperature zone. Additionally, we categorize common post-deposition treatments by their influence on the degradation products seen in MAPbI3 films. Furthermore, with these results we give recommendations for VTD reactor design and the feasibility of co-deposition as a film growth technique.

14 SOLAR ENERGY↗

System-level performance and degradation of 21 GWDC of utility-scale PV plants in the United States

We assess the performance of a fleet of 411 utility-scale (i.e., >5 MWAC and ground-mounted) photovoltaic (PV) projects totaling 21.1 GWDC (16.3 GWAC) of capacity, which achieved commercial operations in the United States from 2007 to 2016. This fleet of projects contributed more than 50% of all solar electricity generated in the United States in 2017. Using detailed information on individual project characteristics, in conjunction with modeled irradiance data, we assess the extent to which actual first-year performance has lived up to both modeled and stated expectations. We then analyze system-level performance degradation in subsequent years by employing a “fixed effects” regression model to statistically isolate the impact of age on system performance. We find that this fleet of utility-scale PV projects has generally lived up to ex ante expectations for first-year performance but that subsequent system-level degradation—found to be −1.3%/year (±0.2%)—has, on average, been worse than both ex ante expectations (commonly −0.5%/year) and results from past studies (ranging from −0.8%/year to −1.0%/year). We emphasize that −1.3%/year is a system-level estimate that captures more than just module degradation (e.g., including soiling, balance of plant degradation, and downtime for maintenance and/or other events). A side analysis of a variety of project characteristics suggests that system-level degradation rates tend to be of lower magnitude among newer projects and larger projects and at sites with lower long-term average temperatures.

14 SOLAR ENERGY↗

An Investigation of Heuristic Control Strategies for Multi-Electrolyzer Wind-Hydrogen Systems Considering Degradation

With the growing demand for renewable-energy-powered hydrogen generation and the corresponding increase in plant capacity, individually controlling many electrolyzer stacks will be critical for increasing the plant's lifetime and efficiency. This paper introduces a rule-based controller framework targeting electrolyzer degradation to explore the opportunity space in multi-stack hydrogen plant control. A novel control-oriented degradation model is also presented in this work, which quantifies the impact of steady power input, fluctuating power input, and the number of startup/shutdown cycles on electrolyzer degradation. Using a wind power input signal, 13 controller configurations are tested on 5 MW hydrogen plants consisting of 2, 5, 10, and 25 stacks. These configurations are evaluated on their capability to mitigate electrolyzer degradation and efficiently produce hydrogen from the time-varying input power. The results show that multi-stack control for degradation can extend the plant's lifetime by more than a factor of 3 with minimal impact on instantaneous hydrogen production.

control↗