Search NASA⌕ Search

SEARCH · Search NASA

Results for “Density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

Acoustic measurements of gas density

Sound transmission through gases in an enclosure is considered. Analytical results are given in terms of geometrical parameters, wave numbers, and source type for simple model problems, and are compared with data obtained by Haran (1983). It is concluded that density measurements can be made in a gas contained in an enclosure by measuring the sound pressure level at a receiver located near a dipole source driven at a constant velocity amplitude at low frequencies.

Shakkottai, P.↗

BOREAS HYD-3 Tree Measurements

The BOREAS HYD-3 team collected several data sets related to the hydrology of forested areas. This data set contains measurements of canopy density (closure), stem density, and DBH from a variety of sites. Canopy density measurements were made during the FFC-W and FFC-T 1994 in both the SSA and the NSA. Stem density measurements were made during FFC-W 1996 in the SSA only. Canopy density measurements were made using a forest densiometer, while measurements of stem density and DBH were made using standard techniques. This study was undertaken to predict spatial distributions of energy transfer, snow properties important to the hydrology, remote sensing signatures, and transmissivity of gases through the snow and their relation to forests in boreal ecosystems. The data are available in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hardy, Janet P.↗

Three-dimensional wire-mesh capacitor system measures fluid density

Gaging system automatically measures the bulk density of a stored, electrically nonconductive fluid containing varying portions of liquid and vapor. The system employs a three-dimensional wire-mesh capacitor whose capacitance varies with the bulk density of the fluid dielectric medium between the capacitor plates.

Source record↗

Density fluctuations in solar wind flow types at 1 AU: Comparison to Doppler scintillation measurements

Density fluctuations with periods 10 minutes to 1 hour have been investigated in ISEE 3 plasma measurements of solar wind flows at l AU. Coronal hole, interstream, plasma sheet, coronal mass ejection, and interaction region flow types are considered. The ISEE 3 results support the interpretation of the large-scale variations in density fluctuations observed by Doppler scintillation measurement techniques inside 0.2 AU. The highest absolute and relative density fluctuations occur ahead of and within the plasma from coronal mass ejections, with the maximum values occurring between the associated interplanetary shocks and the driver gas. For the quasi-stationary solar wind, density and relative density fluctuations are highest around the heliospheric current sheet and lowest in the high-speed coronal flow. Superposed epoch analysis shows that the region of enhanced density fluctuations and its abrupt boundaries observed in the vicinity of the heliospheric current sheet near the Sun persists to l AU, providing further support for the filamentary nature of the extensions of coronal streamers. The results of this study confirm the advantages of using density fluctuations rather than density as a tracer of solar wind flows with differing origins at the Sun and as a detector of propagating interplanetary disturbances.

Huddleston, D. E.↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Electron and ion density depletions measured in the STS-3 orbiter wake

The third Space Shuttle flight on Columbia carried instrumentation to measure thermal plasma density and temperature. Two separate investigations, the Plasma Diagnostics Package (PDP) and the Vehicle Charging and Potential Experiment (VCAP), carried a Langmuir Probe, and the VCAP also included a Spherical Retarding Potential Analyzer (SRPA). Only those measurements made while the PDP is in the payload bay are discussed here since the VCAP instrumentation remains in the payload bay at all times and the two measurements are compared. The wake behind a large structure (in this case the Space Shuttle Orbiter) flying through the ionospheric plasma is discussed. Much theoretical work was done regarding plasma wakes. The instrumentation on this mission gives the first data taken with a large vehicle in the ionospheric laboratory. First, the PDP Langmuir Probe and its data set will be presented, then the VCAP Langmuir Probe and SRPA with associated data. The agreement between the two data sets is discussed and then followed by some other PDP data which infers an even lower wake density.

Murphy, G. B.↗

X-RAY DENSITOMETER FOR USE IN PLASMA STREAMS

Densitometer for the measurement of mass density of a gas in a localized volume element with application to density measurements in high temperature gas streams

X-RAY DENSITY MEASUREMENT↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗

An Experiment to Study Sporadic Sodium Layers in the Earth's Mesosphere and Lower Thermosphere

The Utah State University / Space Dynamics Lab was funded under a NASA Grant. This investigation has been part of Rockwell Universities Sudden Atom Layer Investigation (SAL). USU/SDL provided an electron density measurement instrument, the plasma frequency probe, which was launched on the vehicle 21.117 from Puerto-Rico in February of 1998. The instrument successfully measured electron density as designed and measurement techniques included in this version of the Plasma Frequency probe provided valuable insight into the electron density structures associated with sudden sodium layers in a collisional plasma. Electron density data was furnished to Rockwell University but no science meetings were held by Rockwell Data from the instrument was presented to the scientific community at the URSI General Session in 1999. A paper is in preparation for publication in Geophysical Research Letters. The following document provides a summary of the experiment and data obtained as a final report on this grant.

Swenson, Charles M.↗