Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MFANS 2024 - Dimensional Analysis Made Easy

There is a significant impact of dimensional errors in systems. Dimensional analysis is difficult due to the large size of systems. SA4U and Scalpel are practical programs which can have an impact beyond traditional software as they are able to perform precise dimensional analysis and repair C++ source code.

97 MATHEMATICS AND COMPUTING↗

Verification of the PERSENT Software

Ongoing commercial design activities require a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system and substantial work has been done to verify its accuracy on several identified commercial needs. This manuscript details the verification work done on PERSENT which relies upon the DIF3D code for its forward and adjoint flux solution. Previous work identified the PERSENT features required to be verified to support commercial design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying PERSENT’s ability to correctly calculate four key quantities: perturbation worth distributions, kinetics parameters, sensitivity coefficients, and cross section uncertainty quantification. This manuscript provides the verification tasks and their results with respect to these quantities needed for commercial design activities. For the perturbation worth distributions, hand calculations are deployed to verify the PERSENT calculated results. Similarly, hand calculation of the PERSENT computed kinetics parameters is also used to verify the PERSENT results. In both of these, the input to PERSENT is manipulated to ensure the hand calculation exactly matches the equations PERSENT is calculating. The sensitivity coefficients involve calculating the derivatives of a parameter (such as reactivity worth), with respect to the cross section data. Direct finite difference calculations with DIF3D are used to verify the PERSENT calculated results. For the uncertainty quantification, manufactured input to PERSENT is used to allow an exact hand calculation to reproduce the PERSENT calculated results. The work detailed in this report verified that significant issues were identified for earlier versions of PERSENT for sensitivity coefficients which were corrected in this work and thus version 12.1.0 of PERSENT must be used to reproduce all of the verified work in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal design of antireflection coating and experimental verification by plasma enhanced chemical vapor deposition in small displays

Conventional antireflection coating by thin films of quarter-wavelength thickness is limited by material selections and these films' refractive indices. The optimal design by non-quarter-wavelength thickness is presented in this study. A multilayer thin-film model is developed by the admittance loci to show that the two-layer thin film of SiN{sub x}/SiO{sub y} at 124/87 nm and three layer of SiN{sub x}/SiN{sub y}/SiO{sub z} at 58/84/83 nm can achieve average transmittances of 94.4% and 94.9%, respectively, on polymer, glass, and silicon substrates. The optimal design is validated by plasma enhanced chemical vapor deposition of N{sub 2}O/SiH{sub 4} and NH{sub 3}/SiH{sub 4} to achieve the desired optical constants. Application of the antireflection coating to a 4 in. liquid crystal display demonstrates that the transmittance is over 94%, the mean luminance can be increased by 25%, and the total reflection angle increased from 41 deg. to 58 deg.

36 MATERIALS SCIENCE↗

Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy

Purpose: Standard amorphous silicon electronic portal imaging devices (a-Si EPIDs) are x-ray imagers used frequently in radiotherapy that indirectly detect incident x-rays using a metal plate and phosphor screen. These detectors may also be used as two-dimensional dosimeters; however, they have a well-characterized nonwater-equivalent dosimetric response. Plastic scintillating (PS) fibers, on the other hand, have been shown to respond in a water-equivalent manner to x-rays in the energy range typically encountered during radiotherapy. In this study, the authors report on the first experimental measurements taken with a novel prototype PS a-Si EPID developed for the purpose of performing simultaneous imaging and dosimetry in radiotherapy. This prototype employs an array of PS fibers in place of the standard metal plate and phosphor screen. The imaging performance and dosimetric response of the prototype EPID were evaluated experimentally and compared to that of the standard EPID.Methods: Clinical 6 MV photon beams were used to first measure the detector sensitivity, linearity of dose response, and pixel noise characteristics of the prototype and standard EPIDs. Second, the dosimetric response of each EPID was evaluated relative to a reference water-equivalent dosimeter by measuring the off-axis and field size response in a nontransit configuration, along with the off-axis, field size, and transmission response in a transit configuration using solid water blocks. Finally, the imaging performance of the prototype and standard EPIDs was evaluated quantitatively by using an image quality phantom to measure the contrast to noise ratio (CNR) and spatial resolution of images acquired with each detector, and qualitatively by using an anthropomorphic phantom to acquire images representative of human anatomy.Results: The prototype EPID's sensitivity was 0.37 times that of the standard EPID. Both EPIDs exhibited responses that were linear with delivered dose over a range of 1–100 monitor units. Over this range, the prototype and standard EPID central axis responses agreed to within 1.6%. Images taken with the prototype EPID were noisier than those taken with the standard EPID, with fractional uncertainties of 0.2% and 0.05% within the central 1 cm{sup 2}, respectively. For all dosimetry measurements, the prototype EPID exhibited a near water-equivalent response whereas the standard EPID did not. The CNR and spatial resolution of images taken with the standard EPID were greater than those taken with the prototype EPID.Conclusions: A prototype EPID employing an array of PS fibers has been developed and the first experimental measurements are reported. The prototype EPID demonstrated a much morewater-equivalent dose response than the standard EPID. While the imaging performance of the standard EPID was superior to that of the prototype, the prototype EPID has many design characteristics that may be optimized to improve imaging performance. This investigation demonstrates the feasibility of a new detector design for simultaneous imaging and dosimetry treatment verification in radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk-Informed Monitoring, Verification and Accounting (RI-MVA): An NRAP White Paper Documenting Methods and a Demonstration Model for Risk-Informed MVA System Design and Operations in Geologic Carbon Sequestration

This white paper accompanies a demonstration model that implements methods for the risk-informed design of monitoring, verification and accounting (RI-MVA) systems in geologic carbon sequestration projects. The intent is that this model will ultimately be integrated with, or interfaced with, the National Risk Assessment Partnership (NRAP) integrated assessment model (IAM). The RI-MVA methods described here apply optimization techniques in the analytical environment of NRAP risk profiles to allow systematic identification and comparison of the risk and cost attributes of MVA design options.

carbon sequestration↗

Design, dynamic modeling and wave basin verification of a Hybrid Wave–Current Energy Converter

Massive and high-density Marine and Hydrokinetic (MHK) energy is contained in the ocean, including waves, tidal streams, and ocean currents. Traditional MHK energy converters harvest energy from only a single MHK energy source, which does not fully exploit the energy potential that co-exists in multiple forms of MHK energy in the ocean. This paper presents the design and dynamics of a Hybrid Wave–Current Energy Converter (HWCEC) that can simultaneously convert both wave and current energy to electricity with a single Power Take-off (PTO) through the engagement and disengagement of the three one-way clutches. The critical design parameters are analyzed through modeling and simulation, including the transmission ratios, the electrical impedance, and the turbine-heave plate distance. Water basin tests in a wave–current tank were conducted, which shows the prototyped HWCEC can improve the electric power output by 38%–71% for regular waves and 79% for irregular waves, while providing a 70% reduction of the Peak to Average Ratio (PAR) of power compared to the baseline Wave Energy Converter (WEC). Here we further analyze the occurring percentages of the instant power of both WEC and HWCEC in irregular wave tests, shedding new insight on how HWCEC reduces the PAR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗

Verification and Validation for Energy System Co-Design and Simulation

This project was only active for two months and was terminated due to a re-organization of the sponsoring initiative. The original purpose of the project was to develop and apply verification and validation (V&V) methodologies for the Energy System Co-Design with Multiple Objectives and Power Electronics (E-COMP) Initiative. This report summarizes the project and the work that was completed in the shortened time frame.

42 ENGINEERING↗

Verification of a rapid mooring and foundation design tool

Marine renewable energy devices require mooring and foundation systems that suitable in terms of device operation and are also robust and cost effective. In the initial stages of mooring and foundation development a large number of possible configuration permutations exist. Filtering of unsuitable designs is possible using information specific to the deployment site (i.e. bathymetry, environmental conditions) and device (i.e. mooring and/or foundation system role and cable connection requirements). The identification of a final solution requires detailed analysis, which includes load cases based on extreme environmental statistics following certification guidance processes. Static and/or quasi-static modelling of the mooring and/or foundation system serves as an intermediate design filtering stage enabling dynamic time-domain analysis to be focused on a small number of potential configurations. Mooring and foundation design is therefore reliant on logical decision making throughout this stage-gate process. The open-source DTOcean (Optimal Design Tools for Ocean Energy Arrays) Tool includes a mooring and foundation module, which automates the configuration selection process for fixed and floating wave and tidal energy devices. As far as the authors are aware, this is one of the first tools to be developed for the purpose of identifying potential solutions during the initial stages of marine renewable energy design. While the mooring and foundation module does not replace a full design assessment, it provides in addition to suitable configuration solutions, assessments in terms of reliability, economics and environmental impact. This article provides insight into the solution identification approach used by the module and features the verification of both the mooring system calculations and the foundation design using commercial software. Several case studies are investigated: a floating wave energy converter and several anchoring systems. It is demonstrated that the mooring and foundation module is able to provide device and/or site developers with rapid mooring and foundation design solutions to appropriate design criteria.

42 ENGINEERING↗

Verification of the REBUS Software

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. REBUS is central to this system. The driver for this effort requires the Triangular-Z and hexagonal-Z core geometry options of REBUS to be verified. Previous work identified the REBUS features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying REBUS’s ability to correctly intepret the user input model, verifying that the features identified yield the intended results, and verifying the correctness of the REBUS output tables. The REBUS software verification relies heavily upon the accuracy of the embedded DIF3D software, the verification of which was completed and documented elsewhere. Given that DIF3D produces an accurate solution, the primary focus of the verification in the REBUS software is to ensure that it properly uses the DIF3D solution and that the depletion system (Bateman equations) are correctly implemented. This manuscript reiterates the verification tasks and displays results with respect to the features needed for current design activities. Analytic solutions of the Batemen equations are displayed and the results calculated with REBUS are displayed demonstrating the accuracy. Since coupled Bateman and neutron diffusion/transport solutions are extremely difficult to obtain, much of the focus is placed on how REBUS uses a given DIF3D solution assuming the accuracy of the DIF3D solution. The verification effort identified no issues that are debilitating or otherwise impactful to the design usage of REBUS, and thus REBUS version 11.0, release 3012 is considered verified. It is important to note that several outputs of REBUS are identified to be inaccurate, such as burnup in MWD/MT. Most of the relevant ones for VTR are generally accurate with 10-20% errors which is not impactful as all regular REBUS users are aware of this issue and know how to hand calculate the results. The REBUS manual further makes it clear that these values are consistent with the methodology being used by REBUS and thus the “errors” are more of an inconsistent definition with respect to what a user would expect given a definition in literature. Other issues that were identified included unclear documentation and software bugs all of which were inconsequential to the final results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of the PERSENT Software

Ongoing commercial design activities require a thorough verification of the Argonne Reactor Computation codes to be performed. DIF3D is central to this system and substantial work has been done to verify its accuracy on several identified commercial needs. This manuscript details the verification work done on PERSENT which relies upon the DIF3D for its forward and adjoint flux solution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The human factors verification at plant startup for the AP1000 Plant - 173

The Human Factors (HF) verification at plant startup is the final HF assessment for the AP1000{sup R} HF program and is performed using the as-built plant design. This HF verification has been implemented for the China AP1000 Standard Plant. The scope and objectives of the HF verification at plant startup met the requirements for Verification and Validation (V and V) as described in NUREG-0711, 'Human Factors Engineering Program Review Model'. The majority of the verifications have been completed. Overall, the results confirmed the adequacy of the China AP1000 Standard Plant operating procedures and operator training. A number of design issues were identified and were categorized as safety issues, operability and maintainability issues or minor issues. These issues are being addressed and tracked as site test deficiencies. Based on the current results, it can be concluded that the China AP1000 Standard Plant is safe, operable and maintainable, pending completion of the outstanding verifications and resolution of the identified issues. This paper will describe the overall strategy and discuss the lessons learned in respect to providing HF support to the startup activities for the AP1000 plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NSTX-U In-Vessel Control Coils’ Design Concept

In this paper, a successful conceptual design was completed to develop in-vessel control coils [non-axisymmetric control coils (NCCs)]. The NCCs are a series of saddle coils that are intended to satisfy a number of physics criteria including magnetic breaking, error field control, fast resistive wall mode (RWM) control, and edge-localized-mode stabilization. Customized mineral-insulated cable (MIC) was selected for the conductor material. The MIC was made from oxygen-free copper conductor, high purity magnesium oxide powder insulation, and 304 stainless steel sleeve cover. Sample MIC was purchased from an outside supplier, and various tests were conducted for design and performance verification including high-voltage testing, which necessitated the development of special test terminations. A concept design was also developed for terminating the MIC ends using the nonconductive and vacuum-sealed technique. Two alternative designs were proposed for joints inside the vacuum vessel (VV). The NCCs are designed to be mounted in front of the primary passive plates and underneath the plasma-facing component (PFC) tiles. The passive plates will be modified to accommodate the coils. A new PFC tile design concept was developed using high-Z materials. New designs for the penetrations through the VV wall were developed. One port per coil was planned. Finally, a new power patch panel will be required to provide the ability for various combinations of connections between the NCC, the existing RWM coils, and the existing switching power amplifier power suppliers.

42 ENGINEERING↗

Acceptance Testing of the Scorpius Sweep Magnet

A beam-dump magnet for Scorpius has been defined by LANL and designed and built by Radiabeam Technologies. Initial verification of the Radiabeam design used a magnetic field model provided by Radiabeam and analyzed by LANL tools during September 2021. Simulations indicated that the design was sufficient to meet deflection requirements to protect sensitive equipment in the case of a failed target. In January 2022, the magnet was fabricated and Radiabeam conducted measurements of the magnetic field as a function of position. The measurements deviate somewhat from the simulation. In particular, the peak magnetic field is 10-15% smaller in magnitude than expected from simulation. This note compares the magnetic field measurements to simulation and to measurements of the existing DARHT magnet, which was designed for the same purpose. We show a comparison of the measured beam deflection performance between Scorpius and DARHT and show updated results of LANL’s electron beam tracking code using the Scorpius measurements. Using field measurements we find that the DARHT magnet will deflect a 19.6 MeV electron beam by 46.6° and the Scorpius magnet will deflect by 44.6°. These results show that the as-built Scorpius magnet has met design requirements for beam deflection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Worldwide Radioxenon Backgrounds - The "EU" Project

Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), radioactive xenon (radioxenon) measurements are one of the principle techniques used to detect nuclear underground nuclear explosions, and specifically, the presence of one or more radioxenon isotopes allows one to determine whether a suspected event was a nuclear explosion or originated from an innocent source. During the design of the International Monitoring System (IMS), which was designed as the verification mechanism for the Treaty, it was determined that radioxenon measurements should be performed at 40 or more stations worldwide. At the time of the design of the IMS, however, very few details about the background of the xenon isotopes was known and it is now recognized that the backgrounds were probably evolving anyhow. This paper lays out the beginning of a study of the worldwide concentrations of xenon isotopes that can be used to detect nuclear explosions and several sources that also release radioxenons, and will have to be accounted for during analysis of atmospheric levels. Although the global concentrations of the xenon isotopes are the scope of a much larger activity that could span over several years, this study measures radioxenon concentrations in locations where there was either very little information or there was a unique opportunity to learn more about emissions from known sources. The locations where radioxenon levels were measured and reported are included.

background measurements↗