Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Dynamic Networks Experiments: Virtual Experiments to Quantify Gains in Nuclear Explosion Monitoring

We describe an ongoing series of virtual experiments conducted collaboratively by four United States National Laboratories: Sandia National Laboratories, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Pacific Northwest National Laboratory. These Dynamic Network Experiments (DNEs) provide an experimental framework to evaluate the potential impact of new research tools on nuclear explosion monitoring. The second DNE (DNE2), completed in 2024, exploited waveform data (seismic, infrasound, and electromagnetic) that was recorded by multi-modal sensors within and near the Nevada National Security Site and synthetic radionuclide signatures over multiple time periods. During the execution of DNE2, we processed and analyzed data through a multi-stage event processing pipeline that ingested raw data, performed quality control, detected signals, built events from these signals, located these events, and characterized the events’ source types and sizes. For each stage and over the entire event processing pipeline, we evaluated performance changes by comparing the performance of new data processing methods, models, and algorithms against a baseline. We also performed an additional execution phase to assess event processing pipeline function, speed, and efficiency against that of an expert analyst, including computational and manual efforts. Finally, we assessed the impact and effort of modern computing infrastructure on the monitoring pipeline. This paper describes key elements of the DNEs, from formulation through execution, as demonstrated in DNE2. The DNEs introduce several novel concepts to quantitatively measure the potential impact of new methods on explosion monitoring, including the collaborative design of multi-modal datasets, performance and logistical metrics, and integrated analyses.

42 ENGINEERING↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Unraveling the depth-dependent causal dynamics of methanogenesis and methanotrophy in a high-latitude fen peatland

The dynamics of methane (CH 4 ) cycling in high-latitude peatlands through different pathways of methanogenesis and methanotrophy are still poorly understood due to the spatiotemporal complexity of microbial activities and biogeochemical processes. Additionally, long-term in situ measurements within soil columns are limited and associated with large uncertainties in microbial substrates (e.g. dissolved organic carbon, acetate, hydrogen). To better understand CH 4 cycling dynamics, we first applied an advanced biogeochemical model, ecosys , to explicitly simulate methanogenesis, methanotrophy, and CH 4 transport in a high-latitude fen (within the Stordalen Mire, northern Sweden). Next, to explore the vertical heterogeneity in CH 4 cycling, we applied the PCMCI/PCMCI+ causal detection framework with a bootstrap aggregation method to the modeling results, characterizing causal relationships among regulating factors (e.g. temperature, microbial biomass, soil substrate concentrations) through acetoclastic methanogenesis, hydrogenotrophic methanogenesis, and methanotrophy, across three depth intervals (0–10 cm, 10–20 cm, 20–30 cm). Our results indicate that temperature, microbial biomass, and methanogenesis and methanotrophy substrates exhibit significant vertical variations within the soil column. Soil temperature demonstrates strong causal relationships with both biomass and substrate concentrations at the shallower depth (0–10 cm), while these causal relationships decrease significantly at the deeper depth within the two methanogenesis pathways. In contrast, soil substrate concentrations show significantly greater causal relationships with depth, suggesting the substantial influence of substrates on CH 4 cycling. CH 4 production is found to peak in August, while CH 4 oxidation peaks predominantly in October, showing a lag response between production and oxidation. Overall, this research provides important insights into the causal mechanisms modulating CH 4 cycling across different depths, which will improve carbon cycling predictions, and guide the future field measurement strategies.

54 ENVIRONMENTAL SCIENCES↗

A new metrics framework for quantifying and intercomparing atmospheric rivers in observations, reanalyses, and climate models

We present a new atmospheric river (AR) analysis and benchmarking tool, namely Atmospheric River Metrics Package (ARMP). It includes a suite of new AR metrics that are designed for quick analysis of AR characteristics via statistics in gridded climate datasets such as model output and reanalysis. This package can be used for climate model evaluation in comparison with reanalysis and observational products. Integrated metrics such as mean bias and spatial pattern correlation are efficient for diagnosing systematic AR biases in climate models. For example, the package identifies the fact that, in CMIP5 and CMIP6 (Coupled Model Intercomparison Project Phases 5 and 6) models, AR tracks in the South Atlantic are positioned farther poleward compared to ERA5 reanalysis, while in the South Pacific, tracks are generally biased towards the Equator. For the landfalling AR peak season, we find that most climate models simulate a completely opposite seasonal cycle over western Africa. This tool can also be used for identifying and characterizing structural differences among different AR detectors (ARDTs). For example, ARs detected with the Mundhenk algorithm exhibit systematically larger size, width, and length compared to the TempestExtremes (TE) method. The AR metrics developed from this work can be routinely applied for model benchmarking and during the development cycle to trace performance evolution across model versions or generations and set objective targets for the improvement of models. They can also be used by operational centers to perform near-real-time climate and extreme event impact assessments as part of their forecast cycle.

58 GEOSCIENCES↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical Review of LPBF Metal Print Defects Detection: Roles of Selective Sensing Technology

The integrative potential of LPBF-printed parts for various innovative applications depends upon the robustness and infallibility of the part quality. Eliminating or sufficiently reducing factors contributing to the formation of defects is an integral step to achieving satisfiable part quality. Significant research efforts have been conducted to understand and quantify the triggers and origins of LPBF defects by investigating the material properties and process parameters for LPBF-printed geometries using various sensing technologies and techniques. Frequently, combinations of sensing techniques are applied to deepen the understanding of the investigated phenomena. The main objectives of this review are to cover the roles of selective sensing technologies by (1) providing a summary of LPBF metal print defects and their corresponding causes, (2) informing readers of the vast number and types of technologies and methodologies available to detect defects in LPBF-printed parts, and (3) equipping readers with publications geared towards defect detection using combinations of sensing technologies. Due to the large pool of developed sensing technology in the last few years for LPBF-printed parts that may be designed for targeting a specific defect in metal alloys, the article herein focuses on sensing technology that is common and applicable to most common defects and has been utilized in characterization for an extended period with proven efficiency and applicability to LPBF metal parts defect detection.

36 MATERIALS SCIENCE↗

Rapid Screening of Single-Atom Catalyst Synthesis Conditions Using ToF-SIMS and Facet-Dependent Single-Crystal Substrates

Single-atom catalysts (SACs) offer superior catalytic performance compared to traditional nanoparticle catalysts but are challenging to develop because of the need for extensive optimization and specialized characterization techniques. Here, this study presents a rapid and versatile method for detecting synthesis conditions and elucidating deposition mechanisms of SACs on various substrates. By depositing active elements (Au, Cu, Ni and Rh) on facet-specific single-crystalline substrates (CeO 2 , TiO 2 , MgO and Al 2 O 3 ) and employing time-of-flight secondary ion mass spectroscopy (ToF-SIMS), we assessed facet-dependent deposition behaviors and identified optimal conditions for solution-based SAC synthesis. On CeO 2 and TiO 2 , we confirmed facet-dependent deposition, primarily influenced by oxygen vacancy density and photocatalytic activity, respectively. MgO exhibited the formation of metal oxide/hydroxide clusters for all active elements, and the degree of clustering for Cu and Ni was correlated with the facet hydrolysis susceptibility. Notably, Au and Rh deposition on MgO was facet-independent, attributed to the formation of hydroxide species in solution. Al 2 O 3 , due to its chemical stability and lack of surface defects, did not show active element deposition. This study not only provides a time and cost-efficient method for prescreening SAC synthesis conditions, but it also provides valuable insights into the various deposition mechanisms governing SAC formation on different substrates, paving the way for the rational design of tailored SACs for various catalytic applications.

ToF-SIMS↗

Rapid High-Resolution Analysis of Polysaccharide-Lignin Interactions in Secondary Plant Cell Walls Using Proton-Detected Solid-State NMR

The plant secondary cell wall, a complex matrix composed of cellulose, hemicellulose, and lignin, is crucial for the mechanical strength and water-proofing properties of plant tissues, and serves as a primary source of biomass for biorenewable energy and biomaterials. Structural analysis of these polymers and their interactions within the secondary cell wall has been heavily relying on 13 C-based solid-state NMR techniques. In this study, we explore the application of 1 H-detected solid-state NMR techniques for rapid, high-resolution structural characterization of polysaccharides and lignin, demonstrated on the stems of hardwood eucalyptus. We explored the use of synthesized 2D spectra to resolve central 1 H resonances and the combined application of 3D hCCH and hCHH experiments for complete resonance assignment and unambiguous identification of lignin-carbohydrate interactions. Our findings emphasize the central role of acetylated three-fold xylan conformers, rather than two-fold, in stabilizing the carbohydrate-lignin interface, with glucuronic acid sidechains in eucalyptus glucuronoxylan colocalizing with lignin, revised cellulose-lignin interactions involving uncoated microfibril surfaces, and pectin-lignin interactions indicative of early-stage lignification. These results present a novel approach for rapid structural analysis of lignocellulosic biomaterials without the need for solubilization or extraction.

09 BIOMASS FUELS↗

Structural constraint integration in a generative model for the discovery of quantum materials

Billions of organic molecules have been computationally generated, yet functional inorganic materials remain scarce due to limited data and structural complexity. Here, in this work, we introduce Structural Constraint Integration in a GENerative model (SCIGEN), a framework that enforces geometric constraints, such as honeycomb and kagome lattices, within diffusion-based generative models to discover stable quantum materials candidates. SCIGEN enables conditional sampling from the original distribution, preserving output validity while guiding structural motifs. This approach generates ten million inorganic compounds with Archimedean and Lieb lattices, over 10% of which pass multistage stability screening. High-throughput density functional theory calculations on 26,000 candidates shows over 95% convergence and 53% structural stability. A graph neural network classifier detects magnetic ordering in 41% of relaxed structures. Furthermore, we synthesize and characterize two predicted materials, TiPd 0.22 Bi 0.88 and Ti 0.5 Pd 1.5 Sb, which display paramagnetic and diamagnetic behaviour, respectively. Our results indicate that SCIGEN provides a scalable path for generating quantum materials guided by lattice geometry.

36 MATERIALS SCIENCE↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Structural characterization of highly alloyed (Al,Gd)N thin films

Highly alloyed (Al,Gd)N is of potential interest in a variety of applications, including neutron detection and in devices such as non-volatile memory. Gd has been shown to have very low equilibrium solubility in AlN at room temperature; however, non-equilibrium deposition techniques such as sputtering are able to deposit thin films, which incorporate large amounts of Gd. Here, we characterize a highly-alloyed (Al,Gd)N combinatorial thin film grown by RF sputtering on a GaN substrate, looking for any evidence of chemical or phase segregation or structural disorder in the films. Compositions with between 13% and 32% Gd (on a cation basis) were studied. No evidence was found for chemical or phase segregation in any studied composition. Higher degrees of Gd incorporation led to greater structural disorder in the film and a tendency toward amorphization; however, electron diffraction shows that the film does not become fully amorphous at any of the studied compositions, instead retaining textured local order even at 32% Gd. Electron energy loss spectra suggest that the material retains a locally wurtzite-like tetrahedral bonding environment at all studied compositions.

36 MATERIALS SCIENCE↗

Proton Conducting Neuromorphic Materials and Devices

Neuromorphic computing and artificial intelligence hardware generally aims to emulate features found in biological neural circuit components and to enable the development of energy-efficient machines. In the biological brain, ionic currents and temporal concentration gradients control information flow and storage. It is therefore of interest to examine materials and devices for neuromorphic computing wherein ionic and electronic currents can propagate. Protons being mobile under an external electric field offers a compelling avenue for facilitating biological functionalities in artificial synapses and neurons. In this review, we first highlight the interesting biological analog of protons as neurotransmitters in various animals. We then discuss the experimental approaches and mechanisms of proton doping in various classes of inorganic and organic proton-conducting materials for the advancement of neuromorphic architectures. Since hydrogen is among the lightest of elements, characterization in a solid matrix requires advanced techniques. We review powerful synchrotron-based spectroscopic techniques for characterizing hydrogen doping in various materials as well as complementary scattering techniques to detect hydrogen. First-principles calculations are then discussed as they help provide an understanding of proton migration and electronic structure modification. Outstanding scientific challenges to further our understanding of proton doping and its use in emerging neuromorphic electronics are pointed out.

36 MATERIALS SCIENCE↗