Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A low noise infrared spot scanner for testing detector arrays

A low noise spot scanner has been built for use in testing the performance of infrared detector arrays for NASA's IR detector technology development program and the University of California's MICRO program. The scanner provides a convenient low noise detector test environment and a wide range of test conditions including versatile temperature control of the detector, ambient background, and blackbody source temperature and control of spot size, color, and brightness.

Puetter, R. C.↗

An intensified photodiode array detector for space applications

The Hopkins Ultraviolet Telescope (HUT) is a general purpose moderate resolution spectrograph which is now being constructed for launch on the Space Shuttle. The instrument contains a Rowland spectrograph, which is located at the prime focus of a 0.9-m f/2 parabola. A description is given of the progress which has been made in the development of a flight detector for HUT. The detector developed is an intensified photodiode array. The image intensifier part of the detector contains two 25-mm 80:1, 12-micron pore microchannel plates (PCPs). A thin layer of CsI deposited on the front surface of the first microchannel plate has the objective to increase the quantum efficiency of the detector below 1850 A. The detector system utilizes a spectrometer processor (SP) which is based upon a bit-sliced microprocessor. The current status of the HUT detector system is discussed, and aspects of performance are evaluated. It is felt that the developed system will meet or exceed the design requirements.

Long, K. S.↗

Quantum Well and Quantum Dot Modeling for Advanced Infrared Detectors and Focal Plane Arrays

This viewgraph presentation reviews the modeling of Quantum Well Infrared Detectors (QWIP) and Quantum Dot Infrared Detectors (QDIP) in the development of Focal Plane Arrays (FPA). The QWIP Detector being developed is a dual band detector. It is capable of running on two bands Long-Wave Infrared (LWIR) and Medium Wavelength Infrared (MWIR). The same large-format dual-band FPA technology can be applied to Quantum Dot Infrared Photodetector (QDIP) with no modification, once QDIP exceeds QWIP in single device performance. Details of the devices are reviewed.

quantum well↗

Sensor failure and multivariable control for airbreathing propulsion systems

A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

Behbehani, K.↗

Information extraction and transmission techniques for spaceborne synthetic aperture radar images

Information extraction and transmission techniques for synthetic aperture radar (SAR) imagery were investigated. Four interrelated problems were addressed. An optimal tonal SAR image classification algorithm was developed and evaluated. A data compression technique was developed for SAR imagery which is simple and provides a 5:1 compression with acceptable image quality. An optimal textural edge detector was developed. Several SAR image enhancement algorithms have been proposed. The effectiveness of each algorithm was compared quantitatively.

Frost, V. S.↗

A new-speckle interferometry system for the MAMA detector

We have developed a new system for making speckle observations with the multianode microchannel array (MAMA) detector. This system is a true photon-counting imaging device which records the arrival time of every detected photon and allows for reconstruction of image features near the diffraction limit of the telescope. We present a description of the system and summary of observational results obtained at the Lick Observatory 1-m reflector in 1991 September. The diffraction limit of the 1-m telescope at 5029 A is about 0.125 arcsec and we have successfully resolved the catalogued interferometric binary HD 202582 with a separation of 0.157 +/- 0.031 arcsec. A pair of stars in the open cluster Chi Persei separated by 2.65 +/- 0.22 arcsec with approximate V magnitudes 8.6 and 11.5 has also been successfully analyzed with the speckle technique.

Horch, E.↗

Infrared Detectors Containing Stacked Si(1-x)Ge(x)/Si Layers

Long-wavelength-infrared detectors containing multiple layers of high-quality crystalline p(+) Si(1-x)Ge(x) alternating with layers of Si undergoing development. Each detector comprises stack of Si(1-x)Ge(x)/Si heterojunction internal photoemission (HIP) photodetectors. In comparison with older HIP detectors containing single Si(1-x)Ge(x)/Si heterojunctions, developmental detectors feature greater quantum efficiencies and stronger photoresponses.

Park, Jin S.↗

HgCdTe photodiodes for CO2 laser systems

A recently developed long-wave infrared detector, the photovoltaic HgCdTe, has many advantages which may solve some of the system problems that have impeded the development of carbon dioxide systems. The detectors are available for operation in the temperature range from 77 K to 146 K. Noise problems inherent in a number of conventional detection techniques can be overcome by a suitably implemented optical heterodyne method. Aspects of heterodyne detector development are discussed along with questions concerning the HgCdTe photodiodes which are available.

Koehler, T.↗

Three-function signal generator

Variable-frequency circuit develops sine square and triangular waveforms. Three-function generator used variable-rate integrator to generate triangular wave and zero-crossing detector to develop square wave. Sine wave generator uses diode matrix to operate on triangular wave, thus with design harmonic distortion in output is less then one percent. By changing values of outboard resistors and capacitors, same design can be used at higher frequencies.

Kopp, G. F.↗

Silicon Detector System for Cross Section Measurements

In order to estimate the radiation shielding effectiveness of materials it is necessary to know cosmic ray particles are broken up as they pass though these materials. The breakup of cosmic ray particles is characterized by the nuclear fragmentation cross sections, i.e. an effective geometrical cross section assigned to each target nucleus that represents its apparent size for fragmenting the incident particle. The values of these cross sections depend on the details of nuclear physics and cannot be calculated from first principles owing to the many-body nature of the interactions. The only way to determine them is to measure them. Once a sufficient number of cross sections have been measured, the systematic nature of the interactions allows other cross-sections to be estimated. The number of cross sections that contribute to the estimation of shielding effectiveness is very large 10,000. Fortunately most make minor contributions. These can be estimated from nuclear systematics. Only those who's uncertainties make significant contributions to the error in the shielding effectiveness estimations need to be measured. In the past it has proven difficult to measure light fragment production cross sections from the interactions of heavy cosmic rays owing to the size of the detectors used. We have developed a highly pixilated silicon (Si) detector system that can individually identify these light fragments while making efficient use of costly accelerator time. This system is an outgrowth of detector technology developed under a CDDF and a Code S sponsored cosmic ray experiment.

Source record↗

Multilayered (Hg,Cd)Te infrared detector

Multilayered mercury-cadmium telluride photoconductive detectors were developed which are capable of providing individual coverage of three separate spectral wavelength bands without the use of beam splitters. The multilayered "three-color" detector on a single dewar takes the place of three separate detector/filter/dewar units and enables simpler and more reliable mechanical and optical designs for multispectral scanners and radiometers. Wavelength channel design goals (in micrometers) were: 10.1 to 11.0, 11.0 to 12.0, and 13.0. Detectivity for all channels was 1 x 10 to the 10th power cm-Hz 1/2/Watt. A problem occurred in finding an epoxy layer which had good infrared transmission properties and which also was chemically and mechanically compatible with HgCdTe processing techniques. Data on 6 candidate bonding materials are surveyed and discussed.

Rae, W. G.↗

Uncooled Doped-Si Thermopiles for Thermal Land Imaging Applications

Sustained and enhanced land imaging is crucial for providing high-quality science data on change in land use, forest health, environment, and climate. Future thermal land imaging instruments operating in the 10-12 micron band will provide essential information for furthering our hydrologic understanding at scales of human influence, and producing field-scale moisture information through accurate retrievals of evapotranspiration (ET). To address the need for cost-effective future thermal land imaging missions we are developing novel uncooled doped-silicon thermopile detectors, an extension of a detector design concept originally developed at NASA-Goddard for planetary science applications. These doped-Si thermopile detectors have the potential to offer superior performance in terms of sensitivity, speed, and customization, when compared to current commercial-off-the-shelf uncooled detector technologies. Because cryocooler technology does not need to be fielded on the instrument, these and other uncooled detectors offer the benefit of greatly reduced instrument cost, mass, and power at the expense of some acceptable loss in detector sensitivity. We present the motivation for an uncooled thermal imaging instrument, our doped-Si thermopile detector concept, and performance expectations and comparisons. We also provide an update on the current status of this detector technology development.

Thermopiles↗

Smaller, Lower-Power Fast-Neutron Scintillation Detectors

Scintillation-based fast-neutron detectors that are smaller and less power-hungry than mainstream scintillation-based fast-neutron detectors are undergoing development. There are numerous applications for such detectors in monitoring fast-neutron fluxes from nuclear reactors, nuclear materials, and natural sources, both on Earth and in outer space. A particularly important terrestrial application for small, low-power, portable fast-neutron detectors lies in the requirement to scan for nuclear materials in cargo and baggage arriving at international transportation facilities. The present development of miniature, low-power scintillation-based fast-neutron detectors exploits recent advances in the fabrication of avalanche photodiodes (APDs). Basically, such a detector includes a plastic scintillator, typically between 300 and 400 m thick with very thin silver mirror coating on all its faces except the one bonded to an APD. All photons generated from scintillation are thus internally reflected and eventually directed to the APD. This design affords not only compactness but also tight optical coupling for utilization of a relatively large proportion of the scintillation light. The combination of this tight coupling and the avalanche-multiplication gain (typically between 750 and 1,000) of the APD is expected to have enough sensitivity to enable monitoring of a fast-neutron flux as small as 1,000 cm(exp -2)s(exp -1). Moreover, pulse-height analysis can be expected to provide information on the kinetic energies of incident neutrons. It has been estimated that a complete, fully developed fast-neutron detector of this type, would be characterized by linear dimensions of the order of 10 cm or less, a mass of no more than about 0.5 kg, and a power demand of no more than a few watts.

Patel, Jagdish↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Shortwave infrared 512 x 2 line sensor for earth resources applications

As part of the NASA remote-sensing Multispectral Linear Array Program, an edge-buttable 512 x 2 IRCCD line image sensor with 30-micron Pd2Si Schottky-barrier detectors is developed for operation with passive cooling at 120 K in the 1.1-2.5 micron short infrared band. On-chip CCD multiplexers provide one video output for each 512 detector band. The monolithic silicon line imager performance at a 4-ms optical integration time includes a signal-to-noise ratio of 241 for irradiance of 7.2 microwatts/sq cm at 1.65 microns wavelength, a 5000 dynamic range, a modulation transfer function, greater than 60 percent at the Nyquist frequency, and an 18-milliwatt imager chip total power dissipation. Blemish-free images with three percent nonuniformity under illumination and nonlinearity of 1.25 percent are obtained. A five SWIR imager hybrid focal plane was constructed, demonstrating the feasibility of arrays with only a two-detector loss at each joint.

Tower, J. R.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Proportional counter for X-ray analysis of lunar and planetary surfaces

A position sensitive proportional scintillation detector was developed and evaluated for use in applications involving X-ray imaging as well as spectroscopy. Topics covered include limitations of the proportional scintillation counter for use in space; purification of the xenon gas in the detector, and the operation of the detector system. Results show that the light signal in a proportional scintillation detector remains well localized. With modest electric fields in xenon, the primary electrons from a photoelectric absorption of an X-ray can be brought a distance of a few millimeters to a higher field region without spreading more than a millimeter or so. Therefore, it is possible to make a proportional scintillation detector with good position sensitivity that could be used to calibrate out the difference in light collection over its sensitive volume.

Source record↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗