Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Computational Diagnostic Techniques for Electromagnetic Scattering: Analytical Imaging, Near Fields, and Surface Currents

This paper presents three techniques and the graphics implementations which can be used as diagnostic aides in the design and understanding of scattering structures: Imaging, near fields, and surface current displays. The imaging analysis is a new bistatic k space approach which has potential for much greater information than standard experimental approaches. The near field and current analysis are implementations of standard theory while the diagnostic graphics displays are implementations exploiting recent computer engineering work station graphics libraries.

Hom, Kam W.↗

Studying of multi-shell gas-puff Z-pinches using x-ray spectroscopy with spatial resolution

Dynamics and parameters of gas-puff Z-pinch plasmas at stagnation were studied using x-ray spectroscopic diagnostics. In experiments on a 1 MA pulsed power generator, multilayer coaxial loads were made using a triple-nozzle gas-puff valve. High-luminosity spectrographs with spherically bent crystals made it possible to record spectra with high spatial resolution along the pinch axis and to record two-dimensional plasma images in separate spectral lines. Using various combinations of gases in the nozzles and adding small amounts of a gas tracer, the final structure and composition of the compressed plasma were determined. Furthermore, plasma parameters were estimated by modeling the spectra using the PrismSPECT program, but with the limitation that the spectra were time-integrated, so that spectra from different gases and at different positions may have been emitted at different times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodality stereotactic brain tissue identification: the NASA smart probe project

Real-time tissue identification can benefit procedures such as stereotactic brain biopsy, functional neurosurgery and brain tumor excision. Optical scattering spectroscopy has been shown to be effective at discriminating cancer from noncancerous conditions in the colon, bladder and breast. The NASA Smart Probe extends the concept of 'optical biopsy' by using neural network techniques to combine the output from 3 microsensors contained within a cannula 2. 7 mm in diameter (i.e. the diameter of a stereotactic brain biopsy needle). Experimental data from 5 rats show the clear differentiation between tissues such as brain, nerve, fat, artery and muscle that can be achieved with optical scattering spectroscopy alone. These data and previous findings with other modalities such as (1) analysis of the image from a fiberoptic neuroendoscope and (2) the output from a microstrain gauge suggest the Smart Probe multiple microsensor technique shows promise for real-time tissue identification in neurosurgical procedures. Copyright 2000 S. Karger AG, Basel.

Non-programmatic↗

An ultra-fast method for generating synthetic down-scattered neutron data for inertial confinement fusion implosions

In inertial confinement fusion experiments at the National Ignition Facility, asymmetries are probed by a variety of neutron diagnostics, including neutron imaging systems, real-time neutron activation diagnostics (RTNADs), and neutron spectrometers. It is often useful to generate synthetic data based on these diagnostics to validate and tune models. However, current methods of doing so using Monte Carlo particle tracing are time-consuming. In this paper, an ultra-fast method is presented for generating synthetic neutron images, RTNAD data, and spectrometry data using line integrals and 3D convolutions. While it does not contain as much physics as particle tracing codes, it is thousands of times faster and produces nearly identical data. This enables analysis techniques that depend on generating large amounts of synthetic data, which will prove very useful for the study of asymmetries going forward.

Deuterium↗

MedNAS: Multiscale Training-Free Neural Architecture Search for Medical Image Analysis

Deep neural networks have demonstrated impressive results in medical image analysis, but designing suitable architectures for each specific task is expertise dependent and time consuming. Neural architecture search (NAS) offers an effective means of discovering architectures. It has been highly successful in numerous applications, particularly in natural image classification. Yet, medical images possess unique characteristics, such as small regions and a wide variety of lesion sizes, that differentiate them from natural images. Furthermore, most current NAS methods struggle with high computational costs, especially when dealing with high-resolution image datasets. In this article, we present a novel evolutionary NAS method called multiscale training-free neural architecture search (MSTF-NAS) to address these challenges. Specifically, to accommodate the broad range of lesion region sizes in disease diagnosis, we develop a new reduction cell search space that enables the search algorithm to explicitly identify the optimal scale combination for multiscale feature extraction. Further, to overcome the issue of high computational costs, we utilize training-free indicators as performance measures for candidate architectures, which allows us to search for the optimal architecture more efficiently. More specifically, by considering the capability and simplicity of various networks, we formulate a multiobjective optimization problem that involves two training-free indicators and model complexity for candidate architectures. Extensive experiments on a large medical image benchmark and a publicly available breast cancer detection dataset are conducted. The empirical results demonstrate that our MSTF-NAS outperforms both human-designed architectures and current state-of-the-art NAS algorithms on both datasets, indicating the effectiveness of our proposed method.

60 APPLIED LIFE SCIENCES↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Freestanding high-aspect-ratio gold masks for low-energy, phase-based x-ray microscopy

High-resolution, x-ray phase contrast microscopy, a key technique with promising potential in biomedical imaging and diagnostics, is based on narrow-slit high-aspect-ratio gold gratings. Here we present the development, fabrication details, and experimental testing of the freestanding 10 μm thick gold membrane masks with an array of 0.9–1.5 μm void slit apertures for a novel low-energy x-ray microscope. The overall mask size is 4 mm × 4 mm, with a grating pitch of 7.5 μm, 6.0–6.6 μm wide gold bars are supported by 3 μm wide crosslinks at 400 μm intervals. The fabrication process is based on gold electroplating into a silicon mold coated with various thin films to form a voltage barrier, plating base, and sacrificial layer, followed by the mold removal to obtain the freestanding gold membrane with void slit apertures. We discuss key aspects for the materials and processes, including gold structures homogeneity, residual stresses, and prevention of collapsing of the grid elements. We further demonstrate the possibility to obtain high-resolution, high contrast 2D images of biological samples using an incoherent, rotating anode x-ray tube.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.

Hamilton, Douglas↗

Earth benefits from space life sciences

Contributions of space exploration which are widely recognized are those dealing with the impact of space technology on public health and medical services in both urban and remote rural areas. Telecommunications, image enhancement, 3-dimensional image reconstructions, miniaturization, automation, and data analysis, have transformed the delivery of medical care and have brought about a new impetus to the field of biomedicine. Many areas of medical care and biological research have been affected. These include technological breakthroughs in such areas as: (1) diagnosis, treatment, and prevention of cardiovascular diseases, (2) new approaches to the understanding of osteoporosis, (3) early detection of genetic birth defects, (4) emergency medical care, and (5) treatment of chronic metabolic disorders. These are but a few examples where technology originally developed to support space medicine or space research has been applied to solving medical and health care delivery problems on Earth.

NASA Center HQS↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular Origins of Near-Infrared Luminescence in Molybdenum and Tungsten Oxyhalide Perovskites

Materials with near-infrared (near-IR) luminescence are desirable for applications in communications and sensing, as well as biomedical diagnostics and imaging. The most used inorganic near-IR emitters rely on precise doping of host crystal structures with select rare-earth or transition metal ions. Recently, another class of materials with intrinsic near-IR emission has been reported. The compositions of these materials were initially described as vacancy-ordered halide double perovskites Cs 2 MoCl 6 and Cs 2 WCl 6 , but further investigation by some of us on the compound reported as Cs2WCl6 revealed an oxyhalide instead, with a composition Cs 2 WO x Cl 6–x , where 1 < x < 2. Here we demonstrate that the Mo compounds similarly possess the composition Cs 2 MoO x Cl 6–x or Cs 2 MoO x Br 6–x where 1 < x < 2. Preparing the pure halide appears harder for Mo than for W, and we have not succeeded in doing so. The distinctly different composition requires the coordination environment and oxidation state for the Mo and W centers to be reconsidered from what was assumed for the pure halides. In this work, we examine the mechanism for near-IR emission in these materials given their true structures and compositions. We demonstrate that the luminescence is due to the specific d-orbital splitting caused by the presence of oxygen in the distorted [MOX 5 ] 2– octahedra (X is Cl or Br). The fine structure in the emission spectra at low temperatures has been resolved and is attributed to vibronic coupling to the Mo–O and W–O bond stretches. Understanding the true structure and composition of these interesting materials, besides explaining the near-IR luminescence, suggests how this desirable emission can be realized and manipulated.

36 MATERIALS SCIENCE↗

Predicting Bond Dissociation Energies and Bond Lengths of Coordinatively Unsaturated Vanadium–Ligand Bonds

Understanding the electronic structure of coordinatively unsaturated transition-metal compounds and predicting their physical properties are of great importance for catalyst design. Bond dissociation energy D e and bond length r e are two of the fundamental quantities for which good predictions are important for a successful design strategy. In the present work, recent experimentally measured bond energies and bond lengths of VX diatomic molecules (X = C, N, S) are used as a gauge to consider the utility of a number of electronic structure methods. Single-reference methods are one focus because of their efficiency and utility in practical calculations, and multireference configuration interaction (MRCISD) methods and a composite coupled cluster (CCC) method are a second focus because of their potential high accuracy. The comparison is especially challenging because of the large multireference M diagnostics of these molecules, in the range 0.15–0.19. For the single-reference methods, Kohn–Sham density functional theory (KS-DFT) has been tested with a variety of approximate exchange-correlation functionals. Of these, MOHLYP provides the bond dissociation energies in best agreement with experiments, and BLYP provides the bond lengths that are in best agreement with experiments; but by requiring good performance for both the D e and r e of the vanadium compounds, MOHLYP, MN12-L, MGGA_MS1, MGGA_MS0, O3LYP, and M06-L are the most highly recommended functionals. The CCC calculations include up to connected pentuple excitations for the valence electrons and up to connected quadruple excitations for the core–valence terms; this results in highly accurate dissociation energies and good bond lengths. In conclusion, averaged over the three molecules, the mean unsigned deviation of CCC bond energies from experimental ones is only 0.4 kcal/mol, demonstrating excellent convergence of theory and experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗