Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗

Polarization-dependent atomic dipole traps behind a circular aperture for neutral-atom quantum computing

The neutral-atom quantum computing community has successfully implemented almost all necessary steps for constructing a neutral-atom quantum computer. We present computational results of a study aimed at solving the remaining problem of creating a quantum memory with individually addressable sites for quantum computing. The basis of this quantum memory is the diffraction pattern formed by laser light incident on a circular aperture. Very close to the aperture, the diffraction pattern has localized bright and dark spots that can serve as red-detuned or blue-detuned atomic dipole traps. These traps are suitable for quantum computing even for moderate laser powers. In particular, for moderate laser intensities ({approx}100 W/cm{sup 2}) and comparatively small detunings ({approx}1000-10 000 linewidths), trap depths of {approx}1 mK and trap frequencies of several to tens of kilohertz are achieved. Our results indicate that these dipole traps can be moved by tilting the incident laser beams without significantly changing the trap properties. We also explored the polarization dependence of these dipole traps. We developed a code that calculates the trapping potential energy for any magnetic substate of any hyperfine ground state of any alkali-metal atom for any laser detuning much smaller than the fine-structure splitting for any given electric field distribution. We describe details of our calculations and include a summary of different notations and conventions for the reduced matrix element and how to convert it to SI units. We applied this code to these traps and found a method for bringing two traps together and apart controllably without expelling the atoms from the trap and without significant tunneling probability between the traps. This approach can be scaled up to a two-dimensional array of many pinholes, forming a quantum memory with single-site addressability, in which pairs of atoms can be brought together and apart for two-qubit gates for quantum computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field limitations of Fresnel-regime coherent diffraction imaging

Coherent diffraction imaging (CDI) is a rapidly developing form of imaging that offers the potential of wavelength-limited resolution without image-forming lenses. In CDI, the intensity of the diffraction pattern is measured directly by the detector, and various iterative phase retrieval algorithms are used to “invert” the diffraction pattern and reconstruct a high-resolution image of the sample. But, there are certain requirements in CDI that must be met to reconstruct the object. Although most experiments are conducted in the “far-field”—or Fraunhofer—regime where the requirements are not as stringent, some experiments must be conducted in the “near field” where Fresnel diffraction must be considered. According to the derivation of Fresnel diffraction, successful reconstructions can only be obtained when the small-angle number, a derived quantity, is much less than one. We show, however, that it is not actually necessary to fulfill the small-angle condition. The Fresnel kernel well approximates the exact kernel in regions where the phase oscillates slowly, and in regions of fast oscillations, indicated by large A n , the error between kernels should be negligible due to stationary-phase arguments. Finally we verify, by experiment, this conclusion with a helium neon laser setup and show that it should hold at x-ray wavelengths as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of ZnS thin films synthesized through a non-toxic precursors chemical bath

Highlights: • High quality ZnS thin films have been deposited by chemical bath deposition technique from a non-toxic precursor’s solution. • Nanocrystalline ZnS thin films with large band gap energy were synthesized without using ammonia. • Evidence that the growing of the thin films is carried out by means of hydroxide mechanism was found. • The properties of these ZnS thin films are similar and in some cases better than the corresponding ones produced using toxic precursors such as ammonia. - Abstract: In solar cells, ZnS window layer deposited by chemical bath technique can reach the highest conversion efficiency; however, precursors used in the process normally are materials highly volatile, toxic and harmful to the environment and health (typically ammonia and hydrazine). In this work the characterization of ZnS thin films deposited by chemical bath in a non-toxic alkaline solution is reported. The effect of deposition technique (growth in several times) on the properties of the ZnS thin film was studied. The films exhibited a high percentage of optical transmission (greater than 80%); as the deposition time increased a decreasing in the band gap values from 3.83 eV to 3.71 eV was observed. From chemical analysis, the presence of ZnS and Zn(OH){sub 2} was identified and X-ray diffraction patterns exhibited a clear peak corresponding to ZnS hexagonal phase (1 0 3) plane, which was confirmed by electron diffraction patterns. From morphological studies, compact samples with well-defined particles, low roughness, homogeneous and pinhole-free in the surface were observed. From obtained results, it is evident that deposits of ZnS–CBD using a non-toxic solution are suitable as window layer for TFSC.

36 MATERIALS SCIENCE↗

Characterization of proteins by powder diffraction.

A simulation of a protein powder diffraction pattern was stunning in the apparent amount of information that was seen. A subsequent experiment on metmyoglobin gave a powder diffraction pattern that showed very little sample broadening; the peak widths were essentially limited by the instrument resolution. The challenge is to make use of this in protein structure analysis. This talk will recall some of those early experiments and data analyses as well as an overview of current progress and future possibilities.

59 BASIC BIOLOGICAL SCIENCES↗

Background optimization of powder electron diffraction for implementation of the e-PDF technique and study of the local structure of iron oxide nanocrystals

The local structural characterization of iron oxide nanoparticles is explored using a total scattering analysis method known as pair distribution function (PDF) (also known as reduced density function) analysis. The PDF profiles are derived from background-corrected powder electron diffraction patterns (the e-PDF technique). Due to the strong Coulombic interaction between the electron beam and the sample, electron diffraction generally leads to multiple scattering, causing redistribution of intensities towards higher scattering angles and an increased background in the diffraction profile. In addition to this, the electron–specimen interaction gives rise to an undesirable inelastic scattering signal that contributes primarily to the background. The present work demonstrates the efficacy of a pre-treatment of the underlying complex background function, which is a combination of both incoherent multiple and inelastic scatterings that cannot be identical for different electron beam energies. Therefore, two different background subtraction approaches are proposed for the electron diffraction patterns acquired at 80 kV and 300 kV beam energies. From the least-square refinement (small-box modelling), both approaches are found to be very promising, leading to a successful implementation of the e-PDF technique to study the local structure of the considered nanomaterial.

36 MATERIALS SCIENCE↗

Sensing the wavefront of x-ray free-electron lasers using aerosol spheres

Characterizing intense, focused x-ray free electron laser (FEL) pulses is crucial for their use in diffractive imaging. We describe how the distribution of average phase tilts and intensities on hard x-ray pulses with peak intensities of 10 21 W/m 2 can be retrieved from an ensemble of diffraction patterns produced by 70 nm-radius polystyrene spheres, in a manner that mimics wave-front sensors. Besides showing that an adaptive geometric correction may be necessary for diffraction data from randomly injected sample sources, the paper demonstrates the possibility of collecting statistics on structured pulses using only the diffraction patterns they generate and highlights the imperative to study its impact on single-particle diffractive imaging.

43 PARTICLE ACCELERATORS↗

Unsupervised Segmentation and Clustering Workflow for Efficient Processing of 4D-STEM and 5D-STEM Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) enables mapping of diffraction information with nanometer-scale spatial resolution, offering detailed insight into local structure, orientation, and strain. However, as data dimensionality and sampling density increase, particularly for in situ scanning diffraction experiments (5D-STEM), robust segmentation of structurally consistent behavior across sequential measurements becomes essential for efficient and physically meaningful analysis. Here, we introduce a clustering framework that identifies crystallographically distinct domains from 4D-STEM datasets. By using local diffraction-pattern similarity as a metric, the method extracts closed contours delineating spatially contiguous regions. This approach produces cluster-averaged diffraction patterns that improve signal quality while reducing data volume by orders of magnitude, enabling rapid and accurate orientation, phase, and strain mapping. We demonstrate the applicability of this approach to in situ liquid-cell 4D-STEM data of gold nanoparticle growth. Our method provides a scalable and generalizable route for spatially coherent segmentation, data compression, and quantitative structure–strain mapping across diverse 4D-STEM modalities. The full analysis code and example workflows are publicly available to support reproducibility and reuse.

4D-STEM↗

Simulation and Emulation of X-Ray Diffraction from Dynamic Compression Experiments

Many important aspects of the dynamic thermo-mechanical response of materials occur at the mesoscale, i.e. a physical scale of interactions smaller than what can be adequately described by homogenous behaviors, yet larger than the scale of the atomic lattice. Concurrent advancements in computational power, continuum theory, and experimental diagnostics are enabling unprecedented understanding of such interactions. However, we cannot develop a sufficient level of confidence in such mesoscale capability until the constitutive description of the underlying constituents is reliably representative of their actual physical behavior. Therefore, there is a strong need to combine experimental, modeling, and data-science techniques to validate models of the thermomechanical response of individual single crystals. One experimental diagnostic with high potential impact to shock physics and materials science is in-situ x-ray diffraction. This paper is primarily focused on simulation of x-ray diffraction in shock physics, but with an aim toward quantifying parametric uncertainty of simulation models. Here, we develop and demonstrate a data-science and model-driven approach to constrain the parameterization of continuum models of crystal lattice deformation associated with the shock response of crystalline materials. The framework is built around the connection between continuum hydrodynamic simulations of lattice deformation and a new Bragg diffraction simulation code, BarberShop. The dynamic deformation of a crystal lattice is modeled using the DiscoFlux model within an arbitrary Lagrangian-Eulerian hydrodynamic code, FLAG. These detailed continuum simulations of lattice deformation can be computationally slow, thus a statistical model is used to emulate the evolution of lattice deformation fields in time and across the considered model parameter space. Emulated lattice deformation fields can then be generated rapidly for any combination of physics model parameters. In turn, these fields can be fed into BarberShop to realize a rapid prediction of Bragg diffraction patterns associated with particular values of physics model parameters. The framework enables parameterization of the single crystal model to obtain Bragg diffraction patterns that most closely resemble a corresponding measurement. Furthermore, the framework naturally provides sensitivities of the lattice deformation to the physics parameters. We highlight the utility of this framework through the application to a synthetic closed-loop inverse problem leading to the parameterization of a single crystal material model. As a model problem, we consider the dynamic response of the energetic molecular crystal, cyclotrimethylenetrinitramine (or RDX), under dynamic compression induced by simulated flyer plate impact experiments.

36 MATERIALS SCIENCE↗

K-space algorithmic reconstruction (KAREN): a robust statistical methodology to separate Bragg and diffuse scattering

Diffuse scattering occurring in the Bragg diffraction pattern of a long-range-ordered structure represents local deviation from the governing regular lattice. However, interpreting the real-space structure from the diffraction pattern presents a significant challenge because of the dramatic difference in intensity between the Bragg and diffuse components of the total scattering function. In contrast to the sharp Bragg diffraction, the diffuse signal has generally been considered to be a weak expansive or continuous background signal. In this paper, using 1D and 2D models, it is demonstrated that diffuse scattering in fact consists of a complex array of high-frequency features that must not be averaged into a low-frequency background signal. To evaluate the actual diffuse scattering effectively, an algorithm has been developed that uses robust statistics and traditional signal processing techniques to identify Bragg peaks as signal outliers which can be removed from the overall scattering data and then replaced by statistically valid fill values. This method, described as a 'K-space algorithmic reconstruction' (KAREN), can identify Bragg reflections independent of prior knowledge of a system's unit cell. KAREN does not alter any data other than that in the immediate vicinity of the Bragg reflections, and reconstructs the diffuse component surrounding the Bragg peaks without introducing discontinuities which induce Fourier ripples or artifacts from underfilling `punched' voids. The KAREN algorithm for reconstructing diffuse scattering provides demonstrably better resolution than can be obtained from previously described punch-and-fill methods. The superior structural resolution obtained using the KAREN method is demonstrated by evaluating the complex ordered diffuse scattering observed from the neutron diffraction of a single plastic crystal of CBr 4 using pair distribution function analysis.

36 MATERIALS SCIENCE↗

A compact electron gun for time-resolved electron diffraction

A novel compact time-resolved electron diffractometer has been built with the primary goal of studying the ultrafast molecular dynamics of photoexcited gas-phase molecules. Here, we discuss the design of the electron gun, which is triggered by a Ti:Sapphire laser, before detailing a series of calibration experiments relating to the electron-beam properties. As a further test of the apparatus, initial diffraction patterns have been collected for thin, polycrystalline platinum samples, which have been shown to match theoretical patterns. The data collected demonstrate the focusing effects of the magnetic lens on the electron beam, and how this relates to the spatial resolution of the diffraction pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Symmetry of reentrant tetragonal phase in Ba 1 - x Na x Fe 2 As 2 : Magnetic versus orbital ordering mechanism

Magnetostructural phase transitions in Ba 1-x A x Fe 2 As 2 (A = K, Na) materials are discussed for both magnetically and orbitally driven mechanisms, using a symmetry analysis formulated within the Landau theory of phase transitions. Both mechanisms predict identical orthorhombic space-group symmetries for the nematic and magnetic phases observed over much of the phase diagram, but they predict different tetragonal space-group symmetries for the newly discovered reentrant tetragonal phase in Ba 1-x Na x Fe 2 As 2 (x similar to 0.24-0.28). In a magnetic scenario, magnetic order with moments along the c axis, as found experimentally, does not allow any type of orbital order, but in an orbital scenario, we have determined two possible orbital patterns, specified by P4/mnc1' and I4221' space groups, which do not require atomic displacements relative to the parent I4/mmm1' symmetry and, in consequence, are indistinguishable in conventional diffraction experiments. We demonstrate that the three possible space groups are, however, distinct in resonant x-ray Bragg diffraction patterns created by Templeton & Templeton scattering. This provides an experimental method of distinguishing between magnetic and orbital models.

Khalyavin, D. D.↗

Fundamental Mechanisms Driving the Amorphous to Crystalline Phase Transformation

Phase transformations are ubiquitous, fundamental phenomena that lie at the heart of many structural, optical and electronic properties in condensed matter physics and materials science. Many transformations, especially those occurring under extreme conditions such as rapid changes in the thermodynamic state, are controlled by poorly understood processes involving the nucleation and quenching of metastable phases. Typically these processes occur on time and length scales invisible to most experimental techniques ({micro}s and faster, nm and smaller), so our understanding of the dynamics tends to be very limited and indirect, often relying on simulations combined with experimental study of the ''time infinity'' end state. Experimental techniques that can directly probe phase transformations on their proper time and length scales are therefore key to providing fundamental insights into the whole area of transformation physics and materials science. LLNL possesses a unique dynamic transmission electron microscope (DTEM) capable of taking images and diffraction patterns of laser-driven material processes with resolution measured in nanometers and nanoseconds. The DTEM has previously used time-resolved diffraction patterns to quantitatively study phase transformations that are orders of magnitude too fast for conventional in situ TEM. More recently the microscope has demonstrated the ability to directly image a reaction front moving at {approx}13 nm/ns and the nucleation of a new phase behind that front. Certain compound semiconductor phase change materials, such as Ge{sub 2}Sb{sub 2}Te{sub 5} (GST), Sb{sub 2}Te and GeSb, exhibit a technologically important series of transformations on scales that fall neatly into the performance specifications of the DTEM. If a small portion of such material is heated above its melting point and then rapidly cooled, it quenches into an amorphous state. Heating again with a less intense pulse leads to recrystallization into a vacancy-stabilized metastable rock salt structure. Each transformation takes {approx}10-100 ns, and the cycle can be driven repeatedly a very large number of times with a nanosecond laser such as the DTEM's sample drive laser. These materials are widely used in optical storage devices such as rewritable CDs and DVDs, and they are also applied in a novel solid state memory technology - phase change memory (PCM). PCM has the potential to produce nonvolatile memory systems with high speed, extreme density, and very low power requirements. For PCM applications several materials properties are of great importance: the resistivities of both phases, the crystallization temperature, the melting point, the crystallization speed, reversibility (number of phase-transformation cycles without degradation) and stability against crystallization at elevated temperature. For a viable technology, all these properties need to have good scaling behavior, as dimensions of the memory cells will shrink with every generation. In this LDRD project, we used the unique single-shot nanosecond in situ experimentation capabilities of the DTEM to watch these transformations in GST on the time and length scales most relevant for device applications. Interpretation of the results was performed in conjunction with atomistic and finite-element computations. Samples were provided by collaborators at IBM and Stanford University. We observed, and measured the kinetics of, the amorphous-crystalline and melting-solidification transitions in uniform thin-film samples. Above a certain threshold, the crystal nucleation rate was found to be enormously high (with many nuclei appearing per cubic {micro}m even after nanosecond-scale incubation times), in agreement with atomistic simulation and consistent with an extremely low nucleation barrier. We developed data reduction techniques based on principal component analysis (PCA), revealing the complex, multi-dimensional evolution of the material while suppressing noise and irrelevant information. Using a novel specimen geometry, we also achieved repeated switching between the amorphous and crystalline phases enabling in situ study of structural change after phase cycling, which is relevant to device performance. We also observed the coupling between the phase transformations and the evolution of morphology on the nanometer scale, revealing the gradual development of striations in uniform films and preferential melting at sharp edges in laser-heated nanopatterned GST. This nonuniform melting, interpreted through simulation as being a direct result of geometrical laser absorption effects, appears to be responsible for a marked loss in morphological stability even at moderate laser intensities and may be an important factor in the longevity of nanostructured phase change materials in memory applications.

36 MATERIALS SCIENCE↗

High resolution coherent diffractive imaging with a table-top extreme ultraviolet source

We demonstrate a resolution of 45 nm with a sample size down to 3 μm × 3 μm is achieved in a short exposure time of 2 s, from the diffraction pattern generated by a table-top high harmonic source at around 30 nm. By using a narrow-bandwidth focusing mirror, the diffraction pattern's quality is improved and the required exposure time is significantly reduced. In order to obtain a high quality of the reconstructed image, the ratio of the beam size to the sample size and the curvature of the focused beam need to be considered in the reconstruction process. This new experimental scheme is very promising for imaging sub-10 nm scale objects with a table-top source based on a small inexpensive femtosecond laser system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-differential and integral cross sections for electron-impact ionization for the damage of carbon clusters irradiated with x-ray free-electron lasers

Single-differential and integral cross sections for electron-impact ionization of the C atom and its ions were calculated with the binary-encounter-dipole model [Y.-K. Kim and M. E. Rudd, Phys. Rev. A 50, 3954 (1994)] to study the distribution of free-electron energies in carbon clusters after being irradiated with an x-ray free-electron laser (XFEL). The averaged energies of the secondary electrons for the C atom, and C{sup 1+}, C{sup 2+}, and C{sup 3+} ions were about 20, 70, 160, and 200 eV, respectively, when incident electron energy was about 20 keV, while those energies were in the order of tens of electronvolts when the incident electron energy was about 250 eV. The damage to carbon clusters irradiated with the XFEL was also investigated with time-dependent rate equations, considering photoionization, Compton scattering, Auger decay, and electron-impact ionization of the C atom and its ions. The results show that the electron-impact ionization becomes a more important process as the x-ray flux decreases, while the effect of Auger decay gradually appears as the x-ray flux increases. The energy dependence of the incident x ray was also investigated to evaluate the resolution of the diffraction pattern. These results indicate that we should make the XFEL pulse a few fs and about 16 keV to suppress damage and obtain desired resolution of the diffraction pattern.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simulations of X-ray diffraction of shock-compressed single-crystal tantalum with synchrotron undulator sources

Polychromatic synchrotron undulator X-ray sources are useful for ultrafast single-crystal diffraction under shock compression. Here, simulations of X-ray diffraction of shock-compressed single-crystal tantalum with realistic undulator sources are reported, based on large-scale molecular dynamics simulations. Purely elastic deformation, elastic–plastic two-wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission-mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X-ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of the diffraction patterns is discussed.

Tang, M. X.↗

Single-frame far-field diffractive imaging with randomized illumination

Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

BESSY II↗

In-line holographic imaging and electron density extraction of ultrafast ionized air filaments

In-line spatial holographic methods are used to image the optical diffraction patterns of ultrafast laser produced plasma filaments in air. Using femtosecond laser pump-probe methods the plasma filament is produced and subsequently probed by a time-delayed probe beam traversing the filament at a right angle. The resulting probe beam image is recorded as a holographic diffraction pattern on a charge coupled device camera as the probe beam is diffracted due to the optical index change caused by the plasma filament. Extraction of the electron density in the filament down to 10{sup 16} cm{sup -3} is obtained by using the Helmholtz wave equation beam propagation model to simulate the data. By varying the pump-probe optical time delay, a plasma electron recombination time of approximately 250 ps is measured and agrees with our rate equation population kinetics model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗