Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Progress of Coating Stress Compensation of Silicon Mirrors for Lynx X-ray Telescope Mission Concept Using Thermal Oxide Patterning Method

A thermal oxide patterning method has proven to be effective for correcting coating-stress-induced distortion on flat silicon wafers. We report progress on developing this method for correcting curved silicon mirrors distorted by front-side iridium coatings. Owing to the difference in geometry, a finite element model has been established to calculate the appropriate duty cycle maps in thermal oxide hexagon patterns used for compensation. In addition, a photolithographic process, along with three-dimensional printed equipment, has been developed for creating patterns precisely on the back side of curved mirrors. The developed method has been used to recover the original surface shape of two silicon mirrors which are 100-mm long, 0.5-mm thick, having 312-mm radius of curvature, and 30 deg in azimuthal span (Wolter-I geometry). These mirrors’ front sides are sputter-coated by 20-nm iridium layers with ∼-70 N∕m integrated stress. Measurement results show that the developed method can mitigate coating-induced distortion by a factor of ∼5 in RMS height and ∼4 in RMS slope error, corresponding to ∼0.5 arc sec RMS slope error. Residual errors after correction are dominated by midfrequency ripples created during the annealing process, which will be resolved in the future. The presented method is precise and inexpensive and a potential candidate for resolving the coating stress issue for Lynx optics in the future.

x-ray↗

Estimation of the sub-criticality of the sodium-cooled fast reactor Monju using the modified neutron source multiplication method

The Modified Neutron Source Method (MNSM) is applied to the Monju reactor. This static method to estimate sub-criticality has already given good results on commercial Pressurized Water Reactors. The MNSM consists both in the extraction of the fundamental mode seen by a detector to avoid the effect of higher modes near sources, and the correction of flux distortion effects due to control rod movement. Among Monju's particularities that have a big influence on MNSM factors are: the presence of two californium sources and the position of the detector which is located far from the core outside of the reactor vessel. The importance of spontaneous fission and ({alpha}, n) reactions which have increased during the shutdown period of 15 years will also be discussed. The relative position of detectors and sources deeply affect the correction factors in some regions. In order to evaluate the detector count rate, an analytical propagation has been conducted from the reactor vessel. For two subcritical states, an estimation of the reactivity has been made and compared to experimental data obtained in the restart experiments at Monju (2010). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Broadband distortion modeling in Lyman-α forest BAO fitting

Recently, the Lyman-α absorption observed in the spectra of high-redshift quasars has been used as a tracer of large-scale structure by means of the three-dimensional Lyman-α forest auto-correlation function at redshift z≃ 2.3, but the need to fit the quasar continuum in every absorption spectrum introduces a broadband distortion that is difficult to correct and causes a systematic error for measuring any broadband properties. Here, we describe a k-space model for this broadband distortion based on a multiplicative correction to the power spectrum of the transmitted flux fraction that suppresses power on scales corresponding to the typical length of a Lyman-α forest spectrum. In implementing the distortion model in fits for the baryon acoustic oscillation (BAO) peak position in the Lyman-α forest auto-correlation, we find that the fitting method recovers the input values of the linear bias parameter b F and the redshift-space distortion parameter β F for mock data sets with a systematic error of less than 0.5%. Applied to the auto-correlation measured for BOSS Data Release 11, our method improves on the previous treatment of broadband distortions in BAO fitting by providing a better fit to the data using fewer parameters and reducing the statistical errors on βF and the combination b F (1+β F ) by more than a factor of seven. The measured values at redshift z=2.3 are βF=1.39 +0.11 +0.24 +0.38 -0.10 -0.19 -0.28 and bF(1+βF)=-0.374 +0.007 +0.013 +0.020 -0.007 -0.014 -0.022 (1σ, 2σ and 3σ statistical errors). Our fitting software and the input files needed to reproduce our main results are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-FG-201-04: Computer Vision in Autonomous Quality Assurance of Linear Accelerators

Purpose: Routine quality assurance (QA) of linear accelerators represents a critical and costly element of a radiation oncology center. Recently, a system was developed to autonomously perform routine quality assurance on linear accelerators. The purpose of this work is to extend this system and contribute computer vision techniques for obtaining quantitative measurements for a monthly multi-leaf collimator (MLC) QA test specified by TG-142, namely leaf position accuracy, and demonstrate extensibility for additional routines. Methods: Grayscale images of a picket fence delivery on a radioluminescent phosphor coated phantom are captured using a CMOS camera. Collected images are processed to correct for camera distortions, rotation and alignment, reduce noise, and enhance contrast. The location of each MLC leaf is determined through logistic fitting and a priori modeling based on knowledge of the delivered beams. Using the data collected and the criteria from TG-142, a decision is made on whether or not the leaf position accuracy of the MLC passes or fails. Results: The locations of all MLC leaf edges are found for three different picket fence images in a picket fence routine to 0.1mm/1pixel precision. The program to correct for image alignment and determination of leaf positions requires a runtime of 21– 25 seconds for a single picket, and 44 – 46 seconds for a group of three pickets on a standard workstation CPU, 2.2 GHz Intel Core i7. Conclusion: MLC leaf edges were successfully found using techniques in computer vision. With the addition of computer vision techniques to the previously described autonomous QA system, the system is able to quickly perform complete QA routines with minimal human contribution.

60 APPLIED LIFE SCIENCES↗

Re-Evaluation of Active Interlock Envelopes Considering Insertion Device Correction Coils

The Active Interlock (AI) is a system that ensures that the beam position and angle through the NSLS-II storage ring is located so that the machine apertures that may be struck by synchrotron radiation are not exposed to high power beam which may compromise them. Of particular importance in the NSLS-II is to maintain the beam position and angle within the insertion device (ID) straights where insertions devices make high power x-ray beams for users which may compromise the storage ring vacuum chamber. The beam position and angle in the center of the insertion device is calculated using a pair of beam position monitors (BPMs) on either side of the device. The safe area of positions and angles within the insertion device is called the AI envelope. If there is a magnetic element between the BPMs, it needs to be accounted for in the calculation of the beam position and angle. In addition to the permanent magnet arrays that comprise the insertion device itself, there are correction coils that are used to correct any orbit distortions that are generated by imperfections in the device. It has recently come to our attention that these coils are not considered in the AI calculations, nor are the currents in these coils read by the AI. As it may be possible in theory for these coils to produce angles large enough that the synchrotron radiation beam may damage components, we analyzed the possibility for all ID types and configurations. In this report we show what changes are necessary for the AI envelope, and limits placed upon the correction coils to maintain operation of the storage ring without compromising protection.

36 MATERIALS SCIENCE↗

Application of the modified neutron source multiplication method to the prototype FBR Monju

The Modified Neutron Source Method (MNSM) is applied to the Monju reactor. This static method to estimate sub-criticality has already given good results on commercial Pressurized Water Reactors. The MNSM consists both in the extraction of the fundamental mode seen by a detector to avoid the effect of higher modes near sources, and the correction of flux distortion effects due to control rod movement. Among Monju's particularities that have a big influence on MNSM factors are: the presence of two californium sources and the position of the detector, which is located far from the core outside of the reactor vessel. The importance of spontaneous fission and ({alpha},n) reactions, which have increased during the shutdown period of 15 years, will also be discussed. In order to evaluate the detector count rate, an analytical propagation has been conducted from the reactor vessel. For two subcritical states, an estimation of the reactivity has been made and compared to experimental data obtained in the restart experiments at Monju (2010). Results indicate a good agreement between the MNSM reactivity and the reactivity measured with other methods. The reactivity dependence of the correction to apply to point kinetic equation is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Alcock Paczy'nski test with Baryon Acoustic Oscillations: systematic effects for future surveys

We investigate the Alcock Paczy'nski (AP) test applied to the Baryon Acoustic Oscillation (BAO) feature in the galaxy correlation function. By using a general formalism that includes relativistic effects, we quantify the importance of the linear redshift space distortions and gravitational lensing corrections to the galaxy number density fluctuation. We show that redshift space distortions significantly affect the shape of the correlation function, both in radial and transverse directions, causing different values of galaxy bias to induce offsets up to 1% in the AP test. On the other hand, we find that the lensing correction around the BAO scale modifies the amplitude but not the shape of the correlation function and therefore does not introduce any systematic effect. Furthermore, we investigate in details how the AP test is sensitive to redshift binning: a window function in transverse direction suppresses correlations and shifts the peak position toward smaller angular scales. We determine the correction that should be applied in order to account for this effect, when performing the test with data from three future planned galaxy redshift surveys: Euclid, the Dark Energy Spectroscopic Instrument (DESI) and the Square Kilometer Array (SKA).

79 ASTRONOMY AND ASTROPHYSICS↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Online Image-Guided Anatomical Interventions for Postprostatectomy Cancer Patients

Purpose: To assess daily variations in delivered doses in postprostatectomy patients, using kilovoltage cone-beam CT (CBCT) datasets acquired before and after interventions to correct for observed distortions in volume/shape of rectum and bladder. Methods and Materials: Seventeen consecutive patients treated with intensity-modulated radiotherapy to the prostate bed were studied. For patients with large anatomical variations, quantified by either a rectal wall displacement of >5 mm or bladder volume change of >50% on the CBCT compared with the planning CT, an intervention was performed to adjust the rectum and/or bladder filling. Cumulative doses over the pre- and post-intervention fractions were calculated by tracking the position of the planning CT voxels on different CBCTs using a deformable surface-mapping algorithm. Dose and displacements vectors were projected on two-dimensional maps, the minimal dose received by the highest 95% of the planing target volume (PTV D95) and the highest 10% of the rectum volume (D10) as well as the bladder volume receiving >2 Gy (V2) were evaluated. Results: Of 544 fractions, 96 required intervention. Median (range) number of interventions per patient was 5 (2-12). Compared with the planning values, the mean (SD) pre- vs. postintervention value for PTV D95 was -2% (2%) vs. -1% (2%) (p < 0.12), for rectum D10 was -1% (4%) vs. +1% (4%) (p < 0.24), and for bladder V2 was +6% vs. +20% (p < 0.84). Conclusions: Interventions to reduce treatment volume deformations due to bladder and rectum fillings are not necessary when patients receive daily accurate CBCT localization, and the frequency of those potential interventions is low. However, for hypofractionated treatments, the relative frequency can significantly increase, and interventions can become more dosimetrically beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Neural posterior unfolding

Differential cross section measurements are the currency of scientific exchange in particle and nuclear physics. A key challenge for these analyses is the correction for detector distortions, known as deconvolution or unfolding. Binned unfolding of cross section measurements traditionally rely on the regularized inversion of the response matrix that represents the detector response, mapping pre-detector (`particle level') observables to post-detector (`detector level') observables. In this paper we introduce Neural Posterior Unfolding, a modern, Bayesian approach that leverages normalizing flows for unfolding. By using normalizing flows for neural posterior estimation, NPU offers several key advantages including implicit regularization through the neural network architecture, fast amortized inference that eliminates the need for repeated retraining, and direct access to the full uncertainty in the unfolded result. In addition to introducing NPU, we implement a classical Bayesian unfolding method called Fully Bayesian Unfolding (FBU) in modern Python so it can also be studied. These tools are validated on simple Gaussian examples and then tested on simulated jet substructure examples from the Large Hadron Collider (LHC). We find that the Bayesian methods are effective and worth additional development to be analysis ready for cross section measurements at the LHC and beyond.

Analysis and statistical methods↗

Energy distribution of ternary {alpha} particles in spontaneous fission of {sup 252}Cf

The energy distribution of the ternary {alpha} particles in spontaneous fission of {sup 252}Cf was measured. For the first time an energy threshold as low as 1 MeV was reached. The experiment used an array of unshielded silicon detectors measuring energy and time-of-flight (TOF) of ternary particles in coincidence with fission fragments. The TOF resolution of the system was sufficient for clear separation of {sup 6}He and tritons from {sup 4}He. The statistics were adequate to extract the {sup 6}He/{sup 4}He yield ratio. For both {sup 4}He and {sup 6}He, an excess in the yield (as compared to a Gaussian shape) was observed at energies below 9 MeV. The measured ternary {alpha} spectrum was corrected for the distortion induced by the detection geometry covering equatorial particle emission only. The emission angle was found to affect mainly the width of the energy distribution by up to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for digital image registration using a mathematical programming technique

A new algorithm based on a nonlinear programming technique to correct the geometrical distortions of one digital image with respect to another is discussed. This algorithm promises to be superior to existing ones in that it is capable of treating localized differential scaling, translational and rotational errors over the whole image plane. A series of piece-wise 'rubber-sheet' approximations are used, constrained in such a manner that a smooth approximation over the entire image can be obtained. The theoretical derivation is included. The result of using the algorithm to register four channel S065 Apollo IX digitized photography over Imperial Valley, California, is discussed in detail.

Yao, S. S.↗

A brief review of digital image processing

The review is presented with particular reference to Skylab S-192 and Landsat MSS imagery. Attention is given to rectification (calibration) processing with emphasis on geometric correction of image distortions. Image enhancement techniques (e.g., the use of high pass digital filters to eliminate gross shading to allow emphasis of the fine detail) are described along with data analysis and system considerations (software philosophy).

Billingsley, F. C.↗

The imaging photopolarimeter - The first extraterrestrial spin-scan imager

The paper describes the imaging photopolarimeter used to take close-ups of Jupiter from Pioneers 10 and 11. The instrument operates in a steerable spin-scan mode of operation, contains a 1 in. diameter, f/3.4 Maksutov telescope with a focal plane aperture whose size is selectable. The paper examines those aspects of the design that are substantially influenced by the unusual design constraints, such as choice of detector and method of steering the telescope, and demonstrates the image processing and display techniques used to create the images from the telemetry and correct them for distortion and other defects.

Swindell, W.↗

No new limit on size distribution of gamma-ray bursts

It is argued that the results of Carter et al. (1976), who derived an upper limit to the balloon intensity of small gamma-ray bursts at about 100 below the extrapolated known size spectrum and therefore concluded that the gamma-ray bursts are of galactic origin, are entirely consistent with the -1.5 index power-law extrapolation, so that no conclusion regarding the origin of gamma-ray bursts can be drawn. A reply of Carter et al. is published. Points at issue include: (1) whether a selection criterion of three successive 0.6-sec increases in the gamma-ray count rate ignores a significant or only a small number of events, (2) whether the spectra of all bursts extend below 100 keV, the satellite energy threshold, and (3) the required correction for the distortion of a horizontal, flat detector.

Cline, T. L.↗