Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Closed time like curves enable perfect state distinguishability

The causal self-consistency condition for closed timelike curves can give rise to nonlinear interactions on chronology-respecting qubits. We demonstrate that particular unitary interactions between closed timelike curve qubits and chronology-respecting qubits allow perfect distinguishability of nonorthogonal states, and provide a constructive proof for an arbitrary number of nonorthogonal states. This has a number of highly significant consequences. For example, an adversary with access to closed timelike curves can break the B92, BB84, and SARG04 quantum key distribution protocols, or any prepare-and-measure quantum key distribution scheme. Our result also implies that a party with access to closed timelike curves can violate the Holevo bound by accessing more than log(N) bits of information from an N-dimensional quantum state. In principle, he can transmit an arbitrarily large amount of classical information with a quantum system of fixed size. We discuss the implications of this for quantum cloning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Phase II Trial of Transarterial Embolization Using an n-Butyl-2-Cyanoacrylate/Lipiodol Mixture (JIVROSG-0802)

Purpose: To evaluate the embolic effect and the safety of transarterial embolization (TAE) using n-butyl-2-cyanoacrylate (NBCA) in a prospective multicenter trial. Materials and Methods: This study was an open-label, multicenter, phase II trial. The inclusion criteria were (1) active bleeding or pseudoaneurysm, (2) true aneurysm, (3) arteriovenous malformation (except cerebral lesion), (4) arteriovenous fistula, or (5) need for arterial distribution before transarterial treatment. Selective TAE with NBCA diluted 2–10 times was performed. The primary endpoint was the success rate of embolization with a per-patient analysis based on the angiographic findings. Secondary endpoints were safety, evaluated based on Common Terminology Criteria for Adverse Events (CTCAE) version 4, and the success rate of embolization with a per-vessel calculation. Results: Sixty-five patients were initially enrolled, but due to protocol violation in two patients, efficacy was ultimately analyzed in 63 patients (103 vessels) and safety was analyzed in 64 patients. The success rate per patient was 98.4% (62/63; 95% confidence interval (CI), 91.5–100.00), and the success rate per vessel was 99.0% (102/103; 95% CI, 94.7–100.0). Adverse events of grade 3 or above based on CTCAE version 4 occurred in 22/64 patients (34.4%). Twelve intraoperative or postoperative adverse events grade 3 or above, which may have been related to embolization using NBCA, occurred in 11/64 patients (17.2%). Three patients died after embolization using NBCA, but their deaths were unrelated to TAE. Conclusion: In this prospective multicenter clinical trial, the efficacy of TAE using NBCA was 98.4% and adverse events were clinically acceptable. Level of Evidence: Level 3b.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

eCounter: Inline Per-IP Network Monitoring at Millisecond Resolution via eBPF

Scientific data acquisition (SciDAQ) systems are shifting from archive-based workflows to streaming paradigms, where real-time, fine-grained network monitoring becomes essential. While P4-enabled devices offer per-packet in-band observability, they require specialized switches and routers. Host-side tools like Prometheus exporters lack sufficient temporal granularity. To bridge this gap, we present eCounter, a lightweight, hardware-agnostic, inline telemetry agent built on extended Berkeley Packet Filter (eBPF). eCounter captures per-interface ingress and egress traffic, categorized by IP address and protocol, at millisecond to sub-millisecond resolution. In a 100 Gbps environment, it continuously exports up to 3,257 time-series bins per second with only 4% CPU utilization at a 35¿KiB/s data rate. We evaluate eCounter across diverse NIC MTU settings, hook types, CPU architectures and operating systems, and observed negligible impact on concurrent high-throughput streaming applications. Complexity analysis confirms that it can be readily scaled to distributed SciDAQ deployments.

Mei, Xinxin [Computational Sciences and Technology↗

Concept and architecture of the RHIC LLRF upgrade platform

The goal of the RHIC LLRF upgrade has been the development of a stand alone, generic, high performance, modular LLRF control platform, which can be configured to replace existing systems and serve as a common platform for all new RF systems. The platform is also designed to integrate seamlessly into a distributed network based controls infrastructure, be easy to deploy, and to be useful in a variety of digital signal processing and data acquisition roles. Reuse of hardware, software and firmware has been emphasized to minimize development effort and maximize commonality of system components. System interconnection, synchronization and scaling are facilitated by a deterministic, high speed serial timing and data link, while standard intra and inter chassis communications utilize high speed, non-deterministic protocol based serial links. System hardware configuration is modular and flexible, based on a combination of a main carrier board which can host up to six custom or commercial daughter modules as required to implement desired functionality. This paper will provide an overview of the platform concept, architecture, features and benefits. The RHIC LLRF Upgrade Platform has been developed with the goal of providing a flexible, modular and scalable architecture which will support our current applications and satisfy new ones for the foreseeable future. The platform has been recently commissioned at both RHIC and the RHIC EBIS injector. To date the platform has demonstrated its versatility and utility, meeting the design goals as originally defined.

43 PARTICLE ACCELERATORS↗

Dosimetric properties of a proton beamline dedicated to the treatment of ocular disease

Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systems and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

We report that type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index. Delay differential equations (DDEs) have been frequently used to study complex dynamics observed in nature. More recently, they are used to understand intriguing physiological phenomena such as those expressed by glucose and insulin interaction. We propose a simple set of delay differential equations to model an intravenous glucose tolerance test. This model uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Lastly and most importantly, our model may remove the defect in the well known Minimal Model (MM) which often overestimates the glucose effectiveness (GE) index.

59 BASIC BIOLOGICAL SCIENCES↗

A protocol and analysis of year-long simulations of global storm-resolving models and beyond

We propose a protocol to evaluate and analyze year-long simulations of global storm-resolving models (GSRMs). The proposed protocol complements an earlier 40-day simulation protocol under the DYAMOND (DYnamics of the Atmospheric general circulation Modeled On Non-hydrostatic Domains) project to allow the analysis of the seasonal cycle and associated climatic relevant phenomena. This intercomparison aims to reveal how GSRMs, which can simulate mesoscale convective systems (MCSs) in the global domain, reproduce atmospheric large-scale structures related to convection beyond month-long simulations. The intercomparison for one-year simulations is conducted by either atmosphere-only models or atmosphere–ocean coupled models with atmospheric horizontal mesh sizes less than 5 km. We recommend the continuous four seasons from March 2020 to February 2021 as a target period for the intercomparison but with options for many groups to join more flexibly. The output variables are collected at 0.25° resolution, and archives of a small set of native grid variables are encouraged to analyze tropical cyclones and MCSs. Through the proposed global storm-resolving simulation, we will evaluate the climatological distributions of the atmospheric large-scale circulations, such as the Intertropical Convergence Zone (ITCZ), monsoon, midlatitude jets, their time evolution, and the upscale impacts on them. We present sample analyses from a one-year simulation using the 3.5 km mesh Nonhydrostatic Icosahedral Atmospheric Model (NICAM), revealing the realistic zonal contrast of tropical precipitation, no double ITCZ structure, the reasonable midlatitude jet position and intensity but a weak bias of storm track activities, and a warm bias over the Eurasia during boreal winter. We also clarify the cross-scale interaction, such as the effects of cold pools on mean precipitation over the Maritime Continent through the precipitation diurnal cycle and the effects of resolved gravity waves on midlatitude mean flows. The proposed one-year simulation protocol is referred to as the “Sendai Protocol.” This protocol is not unique or definite for evaluating GSRMs; we prospect a hierarchical set of experiments from short-term to multi-year simulations as GSRM intercomparisons.

54 ENVIRONMENTAL SCIENCES↗

Coherent control of atomic transport in spinor optical lattices

Coherent transport of atoms trapped in an optical lattice can be controlled by microwave-induced spin flips that correlate with site-to-site hopping. We study the controllability of homogeneous one-dimensional systems of noninteracting atoms in the absence of site addressability. Given these restrictions, we construct a deterministic protocol to map an initially localized Wannier state to a wave packet that is coherently distributed over n sites. As an example, we consider a one dimensional quantum walk in the presence of both realistic photon scattering and inhomogeneous broadening of the microwave transition due to the optical lattice. Using composite pulses to suppress errors, fidelities of over 95% can be achieved for a 25-step walk. We extend the protocol for state preparation to analytic solutions for arbitrary unitary maps given homogeneous systems and in the presence of time-dependent uniform forces. Such control is important for applications in quantum information processing, such as quantum computing and quantum simulations of condensed matter phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry S. Wah Leung Endowment Fund.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Agent-based microgrid architecture for generation following protocols

A system for predicting power and loads over a single, relatively short time horizon. More specifically, a system comprising a Storage Agent (S-agent) Cohort within a grid control society, wherein the system expands G and L intra-cohort protocols to allow the S-cohort to participate in power management of the grid by scheduling storage components in source or load roles as determined by the time-varying state of the power imbalance and by the risk-adjusting capacity margin relationship between the G and L cohorts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clock Synchronization in High-end Computing Environments: A Strategy for Minimizing Clock Variance at Runtime

We present a new software-based clock synchronization scheme that provides high precision time agreement among distributed memory nodes. The technique is designed to minimize variance from a reference chimer during runtime and with minimal time-request latency. Our scheme permits initial unbounded variations in time and corrects both slow and fast chimers (clock skew). An implementation developed within the context of the MPI message passing interface is described, and time coordination measurements are presented. Among our results, the mean time variance for a set of nodes improved from 20.0 milliseconds under standard Network Time Protocol (NTP) down to 2.29 secs under our scheme.

clock synchronization↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 AND MCU-11-319

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 are reported. The results show that the solvent at MCU does not require an Isopar{reg_sign} L addition, but it will require addition of trioctylamine. Cesium mass transfer testing with the solvent matches expected extraction behavior but shows a slightly lower stripping efficiency than seen in the original process demonstration for Macrobatch 3. The entrained aqueous solution indicates the scrub wash is significantly out of specification. As a result, the facility replaced the scrub wash. Unlike the previous solvent sample results, these analyses indicate that the solvent does not require minor Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended. The {sup 137}Cs mass transfer results from the solvent sample testing show possible evidence of slightly reduced stripping efficiency. An evaluation (using a model) of expected system performance for MCU using the measured distribution values predicts an {approx}50% decline in DFs given the ESS test results. The customer should consider pulling a SHT sample for reanalysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Clock Synchronization Strategy for Minimizing Clock Variance at Runtime in High-end Computing Environments

We present a new software-based clock synchronization scheme designed to provide high precision time agreement among distributed memory nodes. The technique is designed to minimize variance from a reference chimer during runtime and with minimal time-request latency. Our scheme permits initial unbounded variations in time and corrects both slow and fast chimers (clock skew). An implementation developed within the context of the MPI message passing interface is described and time coordination measurements are presented. Among our results, the mean time variance among a set of nodes improved from 20.0 milliseconds under standard Network Time Protocol (NTP) to 2.29 secs under our scheme.

clock synchronization↗

Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas

Purpose: To establish accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Methods: Protocol patients with advanced extremity sarcomas were treated with external beam radiation therapy and hyperthermia. Invasive temperature measures were compared to noninvasive magnetic resonance thermal imaging (MRTI) at 1.5 T performed during hyperthermia. Volumetric temperature rise images were obtained using the proton resonance frequency shift (PRFS) technique during heating in a 140 MHz miniannular phased array applicator. MRTI temperature changes were compared to invasive measurements of temperature with a multisensor fiber optic probe inside a no. 15 g catheter in the tumor. Since the PRFS technique is sensitive to drifts in the primary imaging magnetic field, temperature change distributions were corrected automatically during treatment using temperature-stable reference materials to characterize field changes in 3D. The authors analyzed MRT images and compared, in evaluable treatments, MR-derived temperatures to invasive temperatures measured in extremity sarcomas. Small regions of interest (ROIs) were specified near each invasive sensor identified on MR images. Temperature changes in the interstitial sensors were compared to the corresponding ROI PRFS-based temperature changes over the entire treatment and over the steady-state period. Nonevaluable treatments (motion/imaging artifacts, noncorrectable drifts) were not included in the analysis. Results: The mean difference between MRTI and interstitial probe measurements was 0.91 deg. C for the entire heating time and 0.85 deg. C for the time at steady state. These values were obtained from both tumor and normal tissue ROIs. When the analysis is done on just the tumor ROIs, the mean difference for the whole power on time was 0.74 deg. C and during the period of steady state was 0.62 deg. C. Conclusions: The data show that for evaluable treatments, excellent correlation ({Delta}T<1 deg. C) of MRTI-ROI and invasive measurements can be achieved, but that motion and other artifacts are still serious challenges that must be overcome in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gate oxide process control optimization by x-ray photoelectron spectroscopy in a semiconductor fabrication line

X-ray photoelectron spectroscopy is a metrology technique that is used for in-line control of decoupled plasma nitridation processes in the fabrication of logic devices. This article shows XPS results of thickness and composition obtained on two types of gate oxide nitrided by a decoupled plasma nitridation process. Measurements are performed in specific test structures with an x-ray spot which can be focused down to 35 {mu}m, enabling process control directly on products. First, XPS is used to characterize and quantify the chemical composition of a SiON layer. The Results show that the nitrogen composition in a SiON layer decreases at a fast rate during the initial days after nitridation processing and stabilizes with time. Second, measurements are performed on products with the objective of transferring process control from monitor to product wafers. In this regard, comparison of nitrogen dose and thickness uniformity on monitor and pattern wafers show similar trends, indicating that measurements of nitrogen dose and thickness on monitor and product wafers give the same information. Third, different mapping protocols are studied on products to identify the best compromise between throughput and an optimized mapping representative of the process distribution. An optimized process control strategy of gate oxides with results is discussed in this article.

36 MATERIALS SCIENCE↗

Dark Energy Survey Year 3 results: A 2.7% measurement of baryon acoustic oscillation distance scale at redshift 0.835

We present angular diameter measurements obtained by measuring the position of baryon acoustic oscillations (BAO) in an optimized sample of galaxies from the first three years of Dark Energy Survey data (DES Y3). The sample consists of 7 million galaxies distributed over a footprint of 4100 deg 2 with 0.6 < z photo < 1.1 and a typical redshift uncertainty of 0.03 ( 1 + z ) . The sample selection is the same as in the BAO measurement with the first year of DES data, but the analysis presented here uses three times the area, extends to higher redshift, and makes a number of improvements, including a fully analytical BAO template, the use of covariances from both theory and simulations, and an extensive preunblinding protocol. We used two different statistics; angular correlation function and power spectrum, and validate our pipeline with an ensemble of over 1500 realistic simulations. Both statistics yield compatible results. We combine the likelihoods derived from angular correlations and spherical harmonics to constrain the ratio of comoving angular diameter distance D M at the effective redshift of our sample to the sound horizon scale at the drag epoch. We obtain D M ( z eff = 0.835 ) / r d = 18.92 ± 0.51 , which is consistent with, but smaller than, the Planck prediction assuming flat Λ CDM , at the level of 2.3 σ . The analysis was performed blind and is robust to changes in a number of analysis choices. It represents the most precise BAO distance measurement from imaging data to date, and is competitive with the latest transverse ones from spectroscopic samples at z > 0.75 . When combined with DES 3 x 2 pt + SNIa , they lead to improvements in H 0 and Ω m constraints by ∼ 20 % .

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental-based mechanistic study and optimization of hydrothermal liquefaction of anaerobic digestates

Valorization of agricultural and food waste digestates is crucial for sustainable waste management to reduce environmental impacts and improve the economics of commercial farms. Hydrothermal liquefaction (HTL) of anaerobic digestates was evaluated to recover resources by converting them into carbon-dense biocrude oil and a nutrient-rich HTL aqueous phase (HTL-AP) coproduct. The effects of HTL temperature (280–360 °C), reaction time (10–50 min), feedstock pH (2.5–8.5), digestate salt content (1–5 wt%), and digestate cellulose-to-lignin ratio (0.2–1.8) on energy and nutrient recovery were systematically investigated in a set of well-designed experiments following a half-fractional central composite protocol. Response surface analysis combined with HTL product characterization and comparative literature study produced a comprehensive reaction pathway for HTL of anaerobic digestates. Moreover, this analysis revealed the importance of acidic feedstocks (pH 3.00–5.53), high reaction temperatures (337–360 °C), and reaction times <45 or 45–50 min for digestates with Cel/Lig >1 or <1, for maximizing the energy recovered in biocrude (high carbon yield and low heteroatom content) and the amounts of P, NH 3 –N, and Mg distributed in the HTL-AP. Acidic conditions catalyzed biocrude production, inhibited the Maillard reaction (lowering the nitrogen content in biocrude), and partitioned nutrients into the HTL-AP. Higher reaction temperatures coupled with longer reaction times activated hydro-denitrogenation and deoxygenation reactions to improve biocrude quality. Finally, this work provides not only validated methods to achieve targeted resource recovery for specific feedstock compositions using HTL, but also a comprehensive mechanistic understanding of the HTL of biomass waste for controlling target product characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗