Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Development of a water calorimetry-based standard for absorbed dose to water in HDR {sup 192}Ir brachytherapy

Purpose: The aim of this article is to develop and evaluate a primary standard for HDR {sup 192}Ir brachytherapy based on 4 deg. C stagnant water calorimetry. Methods: The absolute absorbed dose to water was directly measured for several different Nucletron microSelectron {sup 192}Ir sources of air kerma strength ranging between 21 000 and 38 000 U and for source-to-detector separations ranging between 25 and 70 mm. The COMSOL MULTIPHYSICS software was used to accurately calculate the heat transport in a detailed model geometry. Through a coupling of the ''conduction and convection'' module with the ''Navier-Stokes incompressible fluid'' module in the software, both the conductive and convective effects were modeled. Results: A detailed uncertainty analysis resulted in an overall uncertainty in the absorbed dose of 1.90%(1{sigma}). However, this includes a 1.5% uncertainty associated with a nonlinear predrift correction which can be substantially reduced if sufficient time is provided for the system to come to a new equilibrium in between successive calorimetric runs, an opportunity not available to the authors in their clinical setting due to time constraints on the machine. An average normalized dose rate of 361{+-}7 {mu}Gy/(h U) at a source-to-detector separation of 55 mm was measured for the microSelectron {sup 192}Ir source based on water calorimetry. The measured absorbed dose per air kerma strength agreed to better than 0.8%(1{sigma}) with independent ionization chamber and EBT-1 Gafchromic film reference dosimetry as well as with the currently accepted AAPM TG-43 protocol measurements. Conclusions: This work paves the way toward a primary absorbed dose to water standard in {sup 192}Ir brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code

Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the GEANT 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from GEANT 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LET{sub t} and dose-averaged LET, LET{sub d}) using GEANT 4 for different tracking step size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LET{sub t} and LET{sub d} of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LET{sub t} but significant for LET{sub d}. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in GEANT 4 can result in incorrect LET{sub d} calculation results in the dose plateau region for small step limits. The erroneous LET{sub d} results can be attributed to the algorithm to determine fluctuations in energy deposition along the tracking step in GEANT 4. The incorrect LET{sub d} values lead to substantial differences in the calculated RBE. Conclusions: When the GEANT 4 particle tracking method is used to calculate the average LET values within targets with a small step limit, such as smaller than 500 μm, the authors recommend the use of LET{sub t} in the dose plateau region and LET{sub d} around the Bragg peak. For a large step limit, i.e., 500 μm, LET{sub d} is recommended along the whole Bragg curve. The transition point depends on beam parameters and can be found by determining the location where the gradient of the ratio of LET{sub d} and LET{sub t} becomes positive.

60 APPLIED LIFE SCIENCES↗

SU-E-J-09: Image Quality Comparison and Dose Quantification for 2.5 MV

Purpose: To compare the image quality of the 2.5MV imaging beam (2.5X-IMB) to that of a 6MV beam and to quantify the imaging dose of a 2.5X-IMB for constancy as specified by AAPM TG-142 Methods: The image quality of the 2.5X-IMB was compared to the 6MV imaging beam using the SNC ImagePro MV-QA phantom and the Varian supplied Las Vegas phantom (LVP). High resolution (1280×1280×16, 2 frames at 1.5MU/frame) and low resolution (640×640×16, 2 frames at 0.75MU/frame) images were compared for each phantom. MV-QA phantom images were evaluated quantitatively, and the LVP images were evaluated qualitatively. The imaging dose for 2.5X-IMB was quantified using the procedure outlined in TG51. PTWCC13-31013 chambers were used to measure a percent depth dose (PDD) curve for the 2.5X-IMB. All the factors described in TG51 were calculated using the 2.5X-IMB and a PTW30013 farmer chamber. Results: A comparison between 2.5X-IMB and 6MV image quality was performed both visually and with DoseLab software. The optimal window and level were set for each image of the LVP by the user. Visual inspection showed greater contrast resolution with the 2.5MV beam, but no significant difference with the change in imaging resolution. DoseLab reported similar spatial resolutions between the two energies, but the contrast-to-noise ratio (CNR) was greater for 2.5MV. The PDDx(10cm) for a 10x10cm2 field was measured to be 51.5%. Although this PDD value is off the scale of Figure 4 in TG51, the trend of the curve corresponding to the PTW31003 (equivalent) chamber led to an approximate kQ value of 1.00. Conclusion: When compared to 6MV imaging, 2.5X-IMB results in a better CNR. At low resolution, the DoseLab results for the two energies are comparable, but visual analysis favors the 2.5X-IMB images. Imaging dose was quantified for the 2.5X-IMB after following the TG51 methodology with appropriate approximations.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-09: Performance of HDR Ring Surface Applicator Printed by 3D Printer

Purpose: The commercially available Leipzig-style Cone for High Dose Rate (HDR) Brachytherapy has a steep depth dose curve and a non-uniform dose distribution. This work shows the performance of a Ring Surface Applicator created using a 3D printer that can generate a better dose distribution. Calculated doses were verified with film measurement. Methods: The water equivalent red-ABS plastic was used to print the Ring Surface Applicator which hosts three catheters: a center piece with a straight catheter and two concentric rings with diameters of 3.5 and 5.5 cm. Gafchromic EBT2 film, Epson Expression 10000 flatbed scanner, and the online software at radiochromic.com were used to analyze the measured data. 10cm×10cm piece of film was sandwiched between two 15×10×5cm3 polystyrene phantoms. The applicator was positioned directly on top of the phantom. Measurement was done using dwell time and positions calculated by Eclipse BrachyVision treatment planning system (RTP). Results: Depth dose curve was generated from the plan and measurement. The results show that the measured and calculated depth dose were in agreement (<3%) from surface to 4mm depth. A discrepancy of 6% was observed at 5 mm depth, where the dose is typically prescribed to. For depths deeper than 5 mm, the measured doses were lower than those calculated by Eclipse BrachyVision. This can be attributed to a combination of simple calculation algorithm using TG-43 and the lack of inhomogeneity correction. Dose profiles at 5 mm depth were also generated from TPS calculation and measured with film. The measured and calculated profiles are similar. Consistent with the depth dose curve, the measured dose is lower than the calculated. Conclusion: Our results showed that the Ring Surface Applicator, printed using 3D printer, can generate more uniform dose distribution within the target volume and can be safely used in the clinic.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-201-05: Evaluation of a Windowless Extrapolation Chamber Design and Monte Carlo Based Corrections for the Calibration of Ophthalmic Applicators

Purpose: To test the validity of a windowless extrapolation chamber used to measure surface dose rate from planar ophthalmic applicators and to compare different Monte Carlo based codes for deriving correction factors. Methods: Dose rate measurements were performed using a windowless, planar extrapolation chamber with a {sup 90}Sr/{sup 90}Y Tracerlab RA-1 ophthalmic applicator previously calibrated at the National Institute of Standards and Technology (NIST). Capacitance measurements were performed to estimate the initial air gap width between the source face and collecting electrode. Current was measured as a function of air gap, and Bragg-Gray cavity theory was used to calculate the absorbed dose rate to water. To determine correction factors for backscatter, divergence, and attenuation from the Mylar entrance window found in the NIST extrapolation chamber, both EGSnrc Monte Carlo user code and Monte Carlo N-Particle Transport Code (MCNP) were utilized. Simulation results were compared with experimental current readings from the windowless extrapolation chamber as a function of air gap. Additionally, measured dose rate values were compared with the expected result from the NIST source calibration to test the validity of the windowless chamber design. Results: Better agreement was seen between EGSnrc simulated dose results and experimental current readings at very small air gaps (<100 µm) for the windowless extrapolation chamber, while MCNP results demonstrated divergence at these small gap widths. Three separate dose rate measurements were performed with the RA-1 applicator. The average observed difference from the expected result based on the NIST calibration was −1.88% with a statistical standard deviation of 0.39% (k=1). Conclusion: EGSnrc user code will be used during future work to derive correction factors for extrapolation chamber measurements. Additionally, experiment results suggest that an entrance window is not needed in order for an extrapolation chamber to provide accurate dose rate measurements for a planar ophthalmic applicator.

07 ISOTOPE AND RADIATION SOURCES↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-FG-202-12: Investigation of Longitudinal Salivary Gland DCE-MRI Changes

Purpose: To determine the correlation between dose and changes through treatment in dynamic contrast enhanced (DCE) MRI voxel parameters (Ktrans, kep, Ve, and Vp) within salivary glands of head and neck oropharyngeal squamous cell carcinoma (HNSCC) patients. Methods: 17 HNSCC patients treated with definitive radiation therapy completed DCE-MRI scans on a 3T scanner at pre-treatment, mid-treatment, and post-treatment time points. Mid-treatment and post-treatment DCE images were deformably registered to pre-treatment DCE images (Velocity software package). Pharmacokinetic analysis of the DCE images used a modified Tofts model to produce parameter maps with an arterial input function selected from each patient’s perivertebral space on the image (NordicICE software package). In-house software was developed for voxel-by-voxel longitudinal analysis of the salivary glands within the registered images. The planning CT was rigidly registered to the pre-treatment DCE image to obtain dose values in each voxel. Voxels within the lower and upper dose quartiles for each gland were averaged for each patient, then an average of the patients’ means for the two quartiles were compared. Dose-relationships were also assessed by Spearman correlations between dose and voxel parameter changes for each patient’s gland. Results: Changes in parameters’ means between time points were observed, but inter-patient variability was high. Ve of the parotid was the only parameter that had a consistently significant longitudinal difference between dose quartiles. The highest Spearman correlation was Vp of the sublingual gland for the change in the pre-treatment to mid-treatment values with only a ρ=0.29. Conclusion: In this preliminary study, there was large inter-patient variability in the changes of DCE voxel parameters with no clear relationship with dose. Additional patients may reduce the uncertainties and allow for the determination of the existence of parameter and dose relationships.

60 APPLIED LIFE SCIENCES↗

Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For lower energy radionuclides like {sup 169}Yb, bolus may be needed; and (iii) for the interstitial case, at least a 0.1 cm bolus is advised for {sup 60}Co to avoid underdosing superficial target layers. For {sup 192}Ir and {sup 169}Yb, no bolus is needed. For those cases where no bolus is needed, its use might be detrimental as the lack of radiation scatter may be beneficial to the patient, although the 2% tolerance for dose calculation accuracy recommended in the AAPM TG-56 report is not fulfilled.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗

Radionuclide Air Emission Report for 2009

Berkeley Lab operates facilities where radionuclides are handled and stored. These facilities are subject to the EPA radioactive air emission regulations in 40CFR61, Subpart H (EPA 1989). Radionuclides may be emitted from stacks or vents on buildings where radionuclide production or use is authorized or they may be emitted as diffuse sources. In 2009, all Berkeley Lab sources were minor sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]). These minor sources included more than 100 stack sources and one source of diffuse emissions. There were no unplanned emissions from the Berkeley Lab site. Emissions from minor sources (stacks and diffuse emissions) either were measured by sampling or monitoring or were calculated based on quantities used, received for use, or produced during the year. Using measured and calculated emissions, and building-specific and common parameters, Laboratory personnel applied the EPA-approved computer code, CAP88-PC, to calculate the effective dose equivalent to the maximally exposed individual (MEI). The effective dose equivalent from all sources at Berkeley Lab in 2009 is 7.0 x 10{sup -3} mrem/yr (7.0 x 10{sup -5} mSv/yr) to the MEI, well below the 10 mrem/yr (0.1 mSv/yr) dose standard. The location of the MEI is at the University of California (UC) Lawrence Hall of Science, a public science museum about 1500 ft (460 m) east of Berkeley Lab's Building 56. The estimated collective effective dose equivalent to persons living within 50 mi (80 km) of Berkeley Lab is 1.5 x 10{sup -1} person-rem (1.5 x 10{sup -3} person-Sv) attributable to the Lab's airborne emissions in 2009.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

60 APPLIED LIFE SCIENCES↗

SU-E-T-180: Fano Cavity Test of Proton Transport in Monte Carlo Codes Running On GPU and Xeon Phi

Purpose: In proton dose calculation, clinically compatible speeds are now achieved with Monte Carlo codes (MC) that combine 1) adequate simplifications in the physics of transport and 2) the use of hardware architectures enabling massive parallel computing (like GPUs). However, the uncertainties related to the transport algorithms used in these codes must be kept minimal. Such algorithms can be checked with the so-called “Fano cavity test”. We implemented the test in two codes that run on specific hardware: gPMC on an nVidia GPU and MCsquare on an Intel Xeon Phi (60 cores). Methods: gPMC and MCsquare are designed for transporting protons in CT geometries. Both codes use the method of fictitious interaction to sample the step-length for each transport step. The considered geometry is a water cavity (2×2×0.2 cm{sup 3}, 0.001 g/cm{sup 3}) in a 10×10×50 cm{sup 3} water phantom (1 g/cm{sup 3}). CPE in the cavity is established by generating protons over the phantom volume with a uniform momentum (energy E) and a uniform intensity per unit mass I. Assuming no nuclear reactions and no generation of other secondaries, the computed cavity dose should equal IE, according to Fano's theorem. Both codes were tested for initial proton energies of 50, 100, and 200 MeV. Results: For all energies, gPMC and MCsquare are within 0.3 and 0.2 % of the theoretical value IE, respectively (0.1% standard deviation). Single-precision computations (instead of double) increased the error by about 0.1% in MCsquare. Conclusion: Despite the simplifications in the physics of transport, both gPMC and MCsquare successfully pass the Fano test. This ensures optimal accuracy of the codes for clinical applications within the uncertainties on the underlying physical models. It also opens the path to other applications of these codes, like the simulation of ion chamber response.

60 APPLIED LIFE SCIENCES↗

Characterization of Filters Loaded With Reactor Strontium Carbonate - 13203

A collection of three highly radioactive filters containing reactor strontium carbonate were being prepared for disposal. All three filters were approximately characterized at the time of manufacture by gravimetric methods. The first filter had been partially emptied, and the quantity of residual activity was uncertain. Dose rate to activity modeling using the Monte-Carlo N Particle (MCNP) code was selected to confirm the gravimetric characterization of the full filters, and to fully characterize the partially emptied filter. Although dose rate to activity modeling using MCNP is a common technique, it is not often used for Bremsstrahlung-dominant materials such as reactor strontium. As a result, different MCNP modeling options were compared to determine the optimum approach. This comparison indicated that the accuracy of the results were heavily dependent on the MCNP modeling details and the location of the dose rate measurement point. The optimum model utilized a photon spectrum generated by the Oak Ridge Isotope Generation and Depletion (ORIGEN) code and dose rates measured at 30 cm. Results from the optimum model agreed with the gravimetric estimates within 15%. It was demonstrated that dose rate to activity modeling can be successful for Bremsstrahlung-dominant radioactive materials. However, the degree of success is heavily dependent on the choice of modeling techniques. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Coefficient Calculation for Use in Dosimetry Assessment of a Fission-Based Weapon

In the event of a fission-based weapon or improvised nuclear device (IND) detonation, dose coefficients can be harnessed to provide dose assessments for defense, emergency preparedness, and consequence management, as well as to prospectively inform the assessment of radiation biomarkers and development of medical prophylaxis countermeasures for defense and homeland security stakeholders and decision-makers. Although dose coefficients have previously been calculated for this group, they would apply specifically to the studied population, the 1945 Japanese cohort, after which their anthropomorphic computational phantoms were modeled. For this reason, applications to other populations may be limited, and instead, an assessment of a more standardized population is desired. We employed a series of computational human phantoms representing international reference individuals: UF/NCI voxel phantom series containing newborn, 1-, 5-, 10-, 15-, and 35-year-old males and females. Irradiation of the phantoms was simulated using the Monte Carlo N-Particle transport code to determine organ dose coefficients under four idealized irradiation geometries at three distances from the detonation hypocenter at Hiroshima and Nagasaki using DS02 free-in-air prompt neutron and photon fluence spectra. Through these simulations, age-specific dose coefficients were determined for individual organs. Various articulated PIMAL stylized phantoms were simulated as well to estimate the effect of body posture on dose coefficients and determine the effect of posture on dosimetric estimation and reconstruction. Results additionally demonstrate that 137 Cs and the Watt fission spectra are not ideal general surrogate sources for fission weapons, which may be considered for experimental testing of medical countermeasures. Supplementary data provided tabulates the compilation of organ dose-rate coefficients in this study.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-F-T-22: Clinical Implications When Using TG-186 (ACE) Heterogeneity Software

Purpose: The purpose of this study is to compare dosimetric calculations using traditional TG-43 formalism and Oncentra Brachy Advanced Collapsed cone Engine (ACE) TG-186 calculation algorithm in clinical setting. Methods: We analyzed dosimetry of four patients treated with accelerated partial breast irradiation using a multi-channel intracavitary device (SAVI). All patients were treated to 34 Gy in 10 fractions using a high-dose-rate (192) Ir source. The plans were designed and treated using the TG-43 model. ACE was used to assess the effect heterogeneity correction on various dosimetric parameters. Mass density was estimated using Hounsfield units. Results: Compared to TG-43 formalism, ACE estimated lower doses to targets and organs at risk. The mean difference was 19.8% (range 15.3–24.1%) for PTV-eval V200, 12.0% (range 9.7–17.7%) for PTV-eval V150, 4.3% (range 3.3–6.5%) for PTV-eval D95, 3.3% (range 1.4–5.4%) for PTV-eval D90, 5.4% (range 2.9–9.9%) for maximum rib dose, and 5.7% (2.4–7.4%) for maximum skin dose. There was no correlation between the magnitude of the difference and the PTV-eval volume, air volume, or tissue-applicator conformance. Conclusion: Based on our preliminary study, the TG-43 algorithm appears to overestimate the dose to targets and organs at risk when compared to the ACE TG-186 software. We hypothesize that air adjacent to the SAVI struts contributes to lack of scatter thereby contributing a significant difference in dose calculation when using ACE. We believe that ACE calculation provides a more realistic isodose distribution than TG-43. We plan to further investigate the impact of heterogeneity correction on brachytherapy planning for a wide variety of clinical scenarios, include skin, cervix/uterus, prostate, and lung.

60 APPLIED LIFE SCIENCES↗