Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

Reduction of Systematic Errors in Diagnostic Receivers Through the Use of Balanced Dicke-Switching and Y-Factor Noise Calibrations

Receivers designed for diagnostic applications range from those having moderate sensitivity to those possessing large dynamic range. Digital receivers have a dynamic range which are a function of the number of bits represented by the ADC and subsequent processing. If some of this range is sacrificed for extreme sensitivity, noise power can then be used to perform two-point load calibrations. Since load temperatures can be precisely determined, the receiver can be quickly and accurately characterized; minute changes in system gain can then be detected, and systematic errors corrected. In addition, using receiver pairs in a balanced approach to measuring X+, X-, Y+, Y-, reduces systematic offset errors from non-identical system gains, and changes in system performance. This paper describes and demonstrates a balanced BPM-style diagnostic receiver, employing Dicke-switching to establish and maintain real-time system calibration. Benefits of such a receiver include wide bandwidth, solid absolute accuracy, improved position accuracy, and phase-sensitive measurements. System description, static and dynamic modelling, and measurement data are presented.

99 GENERAL AND MISCELLANEOUS↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Photometric calibrations for 21st century science

The answers to fundamental science questions in astrophysics, ranging from the history of the expansion of the universe to the sizes of nearby stars, hinge on our ability to make precise measurements of diverse astronomical objects. As our knowledge of the underlying physics of objects improves along with advances in detectors and instrumentation, the limits on our capability to extract science from measurements is set, not by our lack of understanding of the nature of these objects, but rather by the most mundane of all issues: the precision with which we can calibrate observations in physical units. In principle, photometric calibration is a solved problem - laboratory reference standards such as blackbody furnaces achieve precisions well in excess of those needed for astrophysics. In practice, however, transferring the calibration from these laboratory standards to astronomical objects of interest is far from trivial - the transfer must reach outside the atmosphere, extend over 4{pi} steradians of sky, cover a wide range of wavelengths, and span an enormous dynamic range in intensity. Virtually all spectrophotometric observations today are calibrated against one or more stellar reference sources, such as Vega, which are themselves tied back to laboratory standards in a variety of ways. This system's accuracy is not uniform. Selected regions of the electromagnetic spectrum are calibrated extremely well, but discontinuities of a few percent still exist, e.g., between the optical and infrared. Independently, model stellar atmospheres are used to calibrate the spectra of selected white dwarf stars, e.g. the HST system, but the ultimate accuracy of this system should be verified against laboratory sources. Our traditional standard star systems, while sufficient until now, need to be improved and extended in order to serve future astrophysics experiments. This white paper calls for a program to improve upon and expand the current networks of spectrophotometrically calibrated stars to provide precise calibration with an accuracy of equal to and better than 1% in the ultraviolet, visible and near-infrared portions of the spectrum, with excellent sky coverage and large dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast perturbation of magnetic domains by optical pumping in a ferromagnetic multilayer

Ultrafast optical pumping of spatially nonuniform magnetic textures is known to induce far-from-equilibrium spin transport effects. Here, we use ultrafast x-ray diffraction with unprecedented dynamic range to study the laser-induced dynamics of labyrinth domain networks in ferromagnetic CoFe/Ni multilayers. We detected azimuthally isotropic, odd order, magnetic diffraction rings up to fifth order. The amplitudes of all three diffraction rings quench to different degrees within 1.6 ps. In addition, all three of the detected diffraction rings both broaden by 15% and radially contract by 6% during the quench process. We are able to rigorously quantify a 31% ultrafast broadening of the domain walls via Fourier analysis of the order-dependent quenching of the three detected diffraction rings. Here, the broadening of the diffraction rings is interpreted as a reduction in the domain coherence length, but the shift in the ring radius, while unambiguous in its occurrence, remains unexplained. In particular, we demonstrate that a radial shift explained by domain-wall broadening can be ruled out. With the unprecedented dynamic range of our data, our results provide convincing evidence that labyrinth domain structures are spatially perturbed at ultrafast speeds under far-from-equilibrium conditions, albeit the mechanism inducing the perturbations remains yet to be clarified.

36 MATERIALS SCIENCE↗

Point spread function deconvolution using a convolutional autoencoder

A major issue in optical astronomical image analysis is the combined effect of the instrument’s point spread function (PSF) and the atmospheric seeing that blurs images and changes their shape in a way that is band and time-of-observation dependent. In this work we present a very simple neural network based approach to nonblind image deconvolution that relies on feeding a convolutional autoencoder (CAE) input images that have been preprocessed by convolution with the corresponding PSF and its regularized inverse, a method which is both conceptually simple and computationally less intensive. We also present here, a new approach for dealing with limited input dynamic range of neural networks compared to the dynamic range present in astronomical images.

79 ASTRONOMY AND ASTROPHYSICS↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗

Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Edot X System

The capability of EdotX would be improved by increasing the instrument's dynamic range to expand the range of signals measurable by the device. The heart of the EdotX system is a two channel analog to digital (A/D) conversion card with two analog to digital converters tightly coupled to a field programmable gate array (FPGA). Signals are continually digitized by the A/D and processed by the FPGA. When the FPGA detects a trigger condition, the data are transferred using direct memory access to the host computer memory, which in turn saves the data to disk. The original design utilizes a single A/D channel for data acquisition. The task was to increase the dynamic range of the system by enabling the second A/D channel, allowing the simultaneous acquisition of the original A/D channel and the additional second A/D channel. The input signal would be fed to the original channel and to the second channel with the second channel input being attenuated. When a signal hits the maximum range of the first channel, the data from the second channel, which is attenuated, are then used. Because both A/D's acquire data simultaneously, they may be used as a single expanded dynamic range channel.

99 GENERAL AND MISCELLANEOUS↗

FY21 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g., height, color and grayscale values; all as functions of a location in a plane projection). A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data, flag significant features, execute Machine Learning (ML) algorithms, output parameters for trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Features can be called out by user-specified thresholds, manual labeling or machine learning algorithms when they have been completed. The ability to rapidly label data is important because of the volume of data required for training machine learning algorithms. The GUI has the flexibility to allow addition of improved ML algorithms, methods for data visualization, and statistical computations. Statistical analyses via the GUI include areas of pits within a defined range of pit depths, correlations between Red-Green-Blue (RGB) or grayscale intensity and relative surface height, covariances between values associated with features, and feature histograms. The development of supervised machine learning algorithms, however, has been hindered by a lack of training data. The machine learning algorithms for crack identification are being refined but require improvements to the true positive rate for crack detection. This shortcoming is an artifact of the limited training data currently available, perhaps more so than the structure of the neural networks. At present, the best results are had from a consensus over an ensemble of randomly generated Deep Neural Network (DNN) or Convolutional Neural Network (CNN) algorithms. Although the consensus accuracy method has yielded optimum true positive and true negative rates in excess of 80%, additional validation testing is necessary. In addition to the suite of LCM data that was initially used, and which represents the majority of the work presented in this report, WAMS image data was also reviewed at a preliminary level. The review included a comparison between image resolution and dynamic range for each method. WAMS (ZON file) image data was found to have a pixel pitch of 3.69μm compared to 1 μm for the LCM (vk4 file) data, which implies a lower resolution for the WAMS images. Conversely, the ratio of dynamic range of the WAMS data to the LCM data was approximately 41:20 for height data, suggesting that information from WAMS should more accurately determine the depth of pits. At present, the significance of the greater dynamic range of the WAMS data relative to the LCM data has not yet been evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗